Professional Documents
Culture Documents
The CSI 9420 delivers complete vibration information, including high resolution spectra and waveform, over a
self-organizing wireless network for use by operations and maintenance personnel.
www.assetweb.com
August 2010
Product Data Sheet
Machinery Health Management ™
Page 2
August 2010
Product Data Sheet
Machinery Health Management ™
Page 3
August 2010
Product Data Sheet
Machinery Health Management ™
The AMS Wireless SNAP-ON application graphically displays your wireless network.
Page 4
August 2010
Product Data Sheet
Machinery Health Management ™
At the heart of Emerson’s Smart Wireless solution is the self-organizing network, featuring tight
security, infinite configurability, and data reliability that rivals wired systems.
Page 5
August 2010
Product Data Sheet
Machinery Health Management ™
Thumbnail Spectrum
The thumbnail spectrum is derived from the same
waveform data. It contains the same frequency
and amplitude information as the high resolution
The acceleration waveform contains raw vibration data
Page 6
August 2010
Product Data Sheet
Machinery Health Management ™
Energy Bands The figure below illustrates how vibration data can
As a final data compression technique, the be used to detect and diagnose a developing fault.
CSI 9420 divides the spectrum into three Based on the increase in overall vibration (black
predetermined energy bands (as shown below). line), an alert would flag the machine as having a
It then calculates the vibration energy within each potential fault – but with no indication at all about
energy band and passes these values to AMS the nature or severity of the fault.
Machinery Manager for trending and alerts. The trend of the three energy bands shows that
the readings for rotor vibration (green) and rotor
harmonics (blue) are stable, while the readings
Band Fault Types Range for high frequency vibration (red) have increased
Rotor Vibration: sharply. This would trigger a special alert for the
1 2–65 Hz rotating equipment specialist in AMS Machinery
Manager.
Imbalance, misalignment
(also defects on belt
Rotor Harmonics
2 65–300 Hz above the trend) confirms that the fault is high
frequency in nature. On-demand acquisition of the
Looseness, electrical
faults, blade and vane
1. Ambient temperature
2. Supply voltage - Paint — Polyurethane
3. Sensor bias voltage - Cover O-ring — Buna-N
Advanced Diagnostics (optional) ■ Terminal Block and Battery Pack
- PBT
■
1. Energy bands
- Rotor vibration (2 - 65 Hz) Antenna
- Rotor harmonics (65 - 300 Hz)
■
- PBT/PC integrated omni-directional antenna
- High Frequency (300 - 1,000 Hz)
2. Thumbnail Spectrum
Mounting
- Fmax: 150, 300, 600, or 1,000 Hz ■ Vibration sensor must be mounted directly on asset being
monitored
3. High Resolution Vibration Spectrum
- Fmax: 1,000 Hz ■ Transmitter may be mounted up to 100’ (30.5 m) away from
- Resolution: 800 or 1,600 lines sensor
- Snapshot or Averaged (4 readings) Weight
4. High Resolution Waveform ■ 4.6 lbs. (2 kg) without LCD
- All measurements based on high resolution waveform
with 4,096 points
■ 4.7 lbs. (2.1 kg) with LCD
Enclosure Ratings
NEMA 4X/IP66
Units
■ English, metric or SI ■
Page 8
August 2010
Product Data Sheet
Machinery Health Management ™
Page 9
August 2010
Product Data Sheet
Machinery Health Management ™
IC ID: 2731A-RM2510 Temperature Code T4 (-40°C < Ta < 85°C), (-20°C < Ta < 80°C
with LCD)
Non-incendive for Class I, Division 2, Groups A, B, C, and D.
Emerson Process Management complies with the ATEX Battery-powered version for use with Rosemount Power
ATEX Directive (94/9/EC)
Temperature Code T4 (-40°C < Ta < 85°C), (-20°C < Ta < 80°C
Certificate Number: 2008943 with LCD)
Canadian Standards Association (CSA)
General Safety Standard Certification conforming to the Battery-powered version for use with Rosemount Power
following standards: Module P/N 00753-9220-XXXX (P/N MHM 89002) only
CSA Std. C22.;2 No. 61010-1-4 Safety Requirements for DC line-powered version for use with 10-28 VDC power supply
Electrical Equipment for Measurement, (class 2)
Control and Laboratory Use, Part I : General Requirements Enclosure Type 4X / IP66
( Second Edition) Conforming to the following standards: CSA Std. C22.2
ISA S82.02.01 2nd (IEC 61010-1 Mod) Safety Standards for No. 0-M91, CSA Std. C22.2 No. 142-M1987, CSA Std. C22.2
Electrical and Electronic Test, No. 213-M1987
Measuring, Controlling and Related Equipment – General
Requirements
ANSI/UL Sta. 61010-1 Electrical Equipment for Measurement, ATEX, Zone 2
Control and Laboratory Use: Part 1
Certificate Number: Baseefa09/ATEX0060X
2.4 GHz
General Requirements (Second Edition)
II 3G Ex ic IIC T4 (-40°C < 85°C), (-20°C < Ta < 80°C with
LCD)
Battery-powered version for use with Rosemount Power
Module P/N 753-9220-XXXX (P/N MHM 89002) only
Enclosure Type IP66
Page 10
August 2010
Product Data Sheet
Machinery Health Management
™
Page 11
August 2010
Product Data Sheet
Machinery Health Management ™
Are You
Wireless?
As any plant manager will tell you, you can’t improve
something if you can’t measure it. Improved access
to information provides the opportunity to reduce
operating costs while improving quality, throughput,
and availability. Add to that the expanding requirement
to certify compliance with new environmental and
safety standards. This all points to the need for
increased monitoring, yet many managers still
believe that the costs outweigh the benefits.
www.assetweb.com