You are on page 1of 1

GENERAL NOTES:

A. ALL PLUMBING WORKS INDICATED HEREIN SHALL MEET THE PROVISION OF


THE PLUMBING CODE OF THE PHILIPPINES, THE NATION PLUMBING CODE,
4000
LOCAL CITY ORDINANCE RULES AND REGULATIONS
B. PLUMBING CONTRACTOR TO COORDINATE WITH OTHER RELATED DRAWINGS
O.C. BOTHWAYS AND SPECIFICATIONS AND NOTIFY THE CONSULTING ENGINEER OF ANY
DISCREPANCY FOUND THEREIN.
C. ALL PIPES SHALL BE INSTALLED AS INDICATED ON PLANS, ANY RELOCATION
EFFLUENT PIPE
REQUIRED FOR PROPER EXECUTION OF OTHER TRADE SHALL BE WITH PRIOR
APPROVAL OF THE ARCHITECT OR ENGINEER..
1600

D. PROPOSED SANITARY ULITIES SHALL CONFORM TO THE ACTUAL SITE CONDITION.


DEPTH AND INVERT ELEVATION OF ALL EXISTING PIPES AND STRUCTURES AS
VERIFIED BY THE CONTRACTOR..
HANDLE
E. ALL SLOPES FOR HORIZONTAL DRAINAGE SHALL MAINTAIN 1% UNLESS OTHERWISE
SPECIFIED.
4" THICK
EFFLUENT PIPE F. SIZE OF WATER SUPPLY PIPES TO FIXTURES SHALL BE IN ACCORDANCE WITH THE
CONCRETE SLAB
MANUFACTURER'S INTRUCTIONS.
PLAN G. THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES AT SITE, TAPPING POINT
AND WATER LINE SERVICE CONNECTING POINT UNLESS OTHERWISE SPECIFIED.
H. ALL FIXTURES SHALL BE INDIVIDUALLY VENTED.
I. ALL PIPE SIZE AND DIMENSION ARE IN MILLIMETERS UNLESS OTHERWISE SPECIFIED.
4000
SECTION
2000 1000 1000

MATERIAL SPECIFICATIONS:
COLD SHALL BE POLYPROPYLENE (PPR) PIPES, PN-20
EFFLUENT PIPE
WATERLINE CONFORMING TO DIN STANDARDS ESSENPLAST
LEACHING LEACHING BRAND OR APPROVED EQUAL
1600

DIGESTIVE CHAMBER
CHAMBER CHAMBER
VENT SHALL BE POLYVINYL CHLORIDE (PVC) PIPE
PIPES SERIES 1000 "CROWN PIPES" OR "EMERALD" BRAND
OR APPROVED EQUAL FITTINGS SHALL BE PVC WITH
SOLVENT CEMENT JOINT TO ASTM DI784
4" THICK
EFFLUENT PIPE CONCRETE SLAB SEWER SHALL BE POLYVINYL CHLORIDE (PVC) PIPE
PARTITIONS PIPES SERIES 1000 "CROWN PIPES" OR "EMERALD" BRAND
OR APPROVED EQUAL FITTINGS SHALL BE PVC WITH
SOLVENT CEMENT JOINT TO ASTM D1784.

GATE "KITZ", "CRANE" BRAND OR APPROVED EQUAL


VALVES
FLOOR SHALL BE CAST IRON BODY W/ BRONZE OR STAINLESS
DRAIN COVER STRAINER "JPI" MODEL JPI-100-13. JPI-100-1
OR APPROVED EQUAL.

FLOOR SHALL BE BRONZE OR STAINLESS COVER "JPI" BRAND


CLEAN BRAND OR APPROVED EQUAL MODEL JPI-135
OUT
WATER LINE SHALL BE BRONZE OR STAINLESS COVER "JPI" BRAND
WATER WATER METER SHALL BE "BADGER", "ARAD", ASAHI
4" CHB WALL METER BRAND OR APPROVED EQUAL
BARS @ 0.20M O.C. EFFLUENT PIPE
BOTHWAYS
LEACHING LEACHING
CHAMBER CHAMBER 4"O DOWNSPOUT
DIGESTIVE CHAMBER
0.10 THK. CHB WALL

150mm0 SOIL PIPE

METAL PLATE COVER

150mm SOIL PIPE


PLASTERED FINISH

SECTION SECTION 10mm0 FOOTING BARS

PLAN SECTION

1 3 4
P-3 P-3 P-3
N T S N T S N T S

PLUMBING ENGINEER / MASTER PLUMBER: PROJECT NAME & LOCATION: SHEET CONTENT: REVISIONS: APPROVED BY: SHEET NO.:
SEPTIC TANK DETAILS
DETAIL OF HOSEBIB
DETAIL OF WATERMETRE
PLUMBING NOTES
P-3
Block 4 Lot 49, Sierra Vista Subd. Brgy. Nagkaisang Nayon,
PRC NO.: PTR NO.:
Novaliches Quezon City 11 11
T I N: ISSUED:

You might also like