| Main control valve The main control valve proportionally controls the Boom elevation, telescope and rotation functions Rated pressure 210 kg/em? (2,990 PSI Solenoid [Rated voltage | DC24 volts Rated flow 100 liters/min (26.4 GPM) Rated current | 800 mA Relief valve [P& | 210 kg/cm’ (2,990 PSD) Coil resistance_| 15.6 ohms (at 20°C) preset pressure [P6 | 90 kg/cm (1,280 PSI) P7_| 150 kw/em? (2,130 PSI) Elevation Rotation Up cw a hi me thet FF a Telescope ou Por relief valve (PO) ‘ 1) q VC t a aap aap oo Main relief valve (P4) a ks Pot ei ae Telescope Elevation Rotation In Down = CCW © Rotation cw a Manual over-ride screw , *s, \ ation CW Port relief valve (P7) 302-00103-008 Operate the boom function manually as follows in case of emergency. 1, Loosen the lock nut. 2. Screw in the manual over-ride screw until the boom begins to move slowly. 3, Screw out the manual over -ride screw to stop the movement of the boom, 4, Set the screw length to 18 mm (0.71 in) after using the manual over-ride screw. 5, Tighten the lock nut. 18mm (0.71 iny Manual over-ride serew Lock nut Telescope Elevation —_—Rotation Out In Up Down CW CCW eva) (ev) (va) At Bt __ 82 368 8 wat v (era) L (iz) Pp i) 6 way 3-9