Typical applications:

1. AT command mode (A5 = OFF), in this mode can be through the serial HyperTerminal (serial assistant) enter
a simple AT command control relay. AT command mode time up to 9999 seconds

2. MODBUS command mode (A5 = ON), you can control a variety of ways: Serial Hyper Terminal Control
(need to manually add the CRC), Modbus Poll software control (software automatically add the CRC), PLC or
MCU process control
Wiring Diagram:

1. DC 12V control circuit, Wiring diagram below. "LOAD" may be camera, LED lights, fans, motors and other
DC 12V equipment.
2. DC 1-100V OR AC 85-265V control circuit, Wiring diagram below (Note: If not DC 12V load, need another
DC 12V power supply). "LOAD" may be LED lights, fans, motors Lights, fluorescent lights, solar water heaters
and other DC AC equipment.
3. DC 1-100V OR AC 85-265V control circuit, Wiring diagram below (Note: If not DC 12V load, need another
DC 12V power supply). "LOAD" may be Machine tool ,CNC,3D Printer, LED lights, fans, motors and other
DC AC equipment
Comandos AT:

En el modo de comandos AT el Slave ID es inválido

Deben ser en mayúsculas

Estatus del DIP Switch: A5 debe estar en OFF, los demás en cualquier estado.

9600 Baud, 8 data bits, None parity, 1 stop bit.

Read status:

Canal 1: AT+R1
Canal 2: AT+R2
Canal 3: AT+R3
Canal 4: AT+R4

Open:

Canal 1: AT+O1
Canal 2: AT+O2
Canal 3: AT+O3
Canal 4: AT+O4

Close:

Canal 1: AT+C1
Canal 2: AT+C2
Canal 3: AT+C3
Canal 4: AT+C4

Toggle (Self-Locking):

Canal 1: AT+T1
Canal 2: AT+T2
Canal 3: AT+T3
Canal 4: AT+T4

Latch (Inter-Locking):

Canal 1: AT+L1
Canal 2: AT+L2
Canal 3: AT+L3
Canal 4: AT+L4

Momentary (Non-Locking):

Canal 1: AT+M1
Canal 2: AT+M2
Canal 3: AT+M3
Canal 4: AT+M4

Delay:

Canal 1: AT+D1=XXXX
Canal 2: AT+D2=XXXX
Canal 3: AT+D3=XXXX
Canal 4: AT+D4=XXXX

Donde XXXX hace referencia al tiempo en segundos desde 0000 hasta 9999