LR81741C
F8
The futuristic-looking new YS100. Innoative man-machine interface, user-friendly design. Enhanced control,
communication, and I/O functions plus the latest controller functions. YS100, the next-generation standard.
Rack-Mount Instruments
sed e
C-ba ing! ce th ase
l e P s Redu ber of Increlability!
Enab proces
■Signal Converters
t a num ments! cont
rol
a u
d i str
n
YS80 YS100
Series Series Series
SDBT SDBS SDBU STED SISD
Distributor Distributor Distributor EMF- and RTD- Isolator
to-Voltage Converter YEWSERIES 80 Rack-Mount Instruments
100 Line YS80 YS100
Series Series Series
■Alarm Set Units ■Computing Units ■Safety
YS80 YS100
Barrier EK Series Series Series
PV trends
indication
Loop 1 digital reading
Process alarm
Indicates in reverse video
the loop that can be manipulated.
System alarm
Loop 2 digital reading The s
Trend-recording
Self-tuning time span either
Loop 1 bar-graph PV indication
alarm In ad
Loop 2 bar-graph PV indication Func
Clear key be us
Acknowledges ing o
alarms
Trend Panel opera
for Windows
You can control two loops at a time with This control mode allows you to preset The YS170 controller is programmed
just one YS170 controller. This control eight sets of PID parameters. using a PC. You can combine some
mode includes cascade control, auto- This feature is useful when, for ex- simple instructions that contain com-
selector control and dual-loop indepen- ample, in a heat treatment process you putational functions to program a vari-
dent control. want to set an optimum set of PID pa- ety of control capabilities, from simple
rameters for each different reaction to advanced control.
temperature.
PID1 ; PB =100、TI=20、TD=0
PID2 ; PB = 80、TI=15、TD=1
The six status I/O terminals are used PID3 ; PB = 60、TI=10、TD=2
⋮ ⋮ ⋮
either as an input or an output. ⋮
⋮
⋮
⋮
⋮
⋮
PID8 ; PB =200、TI=40、TD=0
In addition, the PF (Programmable M
Input port
1 1
2 2
PV computation
SV computation
3
4
3
4
■ Automatic combustion control of boiler with YS170 controller
Bias set unit with Oxygen concentration Main steam
Sequence logic computation
Variable SV filter
PV
computation
Control
Self-tuning
SV
Air flow Fuel flow controller
397 controller SV
398
399
400
Output PV PV
computation FT
YS170 YS170
Atmosphere SH-STEAM
Output port
Fuel
IDF AH
Single-Loop Multi-Function Controller
This mode of the controller controls one This mode has two PID-computation Based on an auto-selector, this control
loop only: basic PID control, nonlinear channels. You can simultaneously view mode has two PID-computation chan-
PID control, PID control with reset bias and monitor the panels of both primary nels. You can simultaneously view and
or PD control with manual reset. and secondary loops. monitor the panels of two control loops.
A C
A C
A C A C
Setting Setting
Setting Setting
Self-tuning Control
O C
A TRK Setting
Auto-selector
Manual operation
A M
Self-tuning Control 2
Self-tuning
0 1 2
Manual operation
A M Manual operation
A M
When a YS150 or YS170 controller undergoes online main- The YS131 meter has two inputs and can display the statuses of
tenance, the YS110 set unit replaces the controller to output a two loops at a time. It has high-limit, low-limit, high-high-limit and
4-20 mA signal to a given final control element. Simply swing up low-low-limit alarms.
the front panel of the controller, connect this unit to the controller,
and replace the internal assembly while keeping the existing
manipulated output active.
The YS135 set unit allows you to manually output a setpoint signal The YS136 loader allows you to manually output a manipulation
to a given controller. The unit is equipped with an operation mode signal to a given final control element. The unit is equipped with
selector switch, and a status input can be used to select between an operation mode selector switch, and a status input can be used
the operation modes. to select between the operation modes.
I/O signal: Input: 1 to 5 V DC (2 channels, with one for direct input) I/O signal: Input: 1 to 5 V DC (2 channels, with one for direct input)
Output: 1 to 5 V DC (1 channel) Output: 4 to 20 mA (1 channel) and 1 to 5 V DC (1 channel)
Status signal: One input, three outputs and one FAIL contact Status signal: One input, three outputs and one FAIL contact
Alarm functions: High/low limits Alarm functions: High/low limits
Input computation: Square-root with low signal cut off Input computation: Square-root with low signal cut off
Trend-recording time span (recording interval): Trend-recording time span (recording interval):
1.5 min (1 sec), 7.5 min (5 sec), 15 min (10 sec), 45 min (30 sec), 1.5 min (1 sec), 7.5 min (5 sec), 15 min (10 sec), 45 min (30 sec),
1.5 hr (1 min), 7.5 hr (5 min), 15 hr (10 min), and 45 hr (30 min) 1.5 hr (1 min), 7.5 hr (5 min), 15 hr (10 min), and 45 hr (30 min)
Amount of data for showing trends: 90 items Amount of data for showing trends: 90 items
Communication: YS-net, RS-485 and DCS-LCS Communication: YS-net, RS-485 and DCS-LCS
High-Speed Controller-to-PC Communication and
Easy Peer to Peer Communication
The YS-net is a high-speed communication network developed specifically
for the YS100 series. It can handle communication of as fast as approximately
78 kbps. Data are transmitted in approximately one second when 16 control-
lers in the YS100 Series are connected to a PC.
You can exchange data between YS170 controllers or between a YS100 and a
PC, without having to make complex settings. What's more, you can easily
add or change the controllers connected to the network.
Peer to Peer
Communication
Data transmitting/receiving Data receiving
This communication mode allows YS170
controllers to communicate with each other
via the YS-net. This is useful for complex YS-net
control computation that requires a greater
number of I/O signals.
High-Speed Communication
with a PC
Using Windows-based spreadsheet soft-
ware, database software or a SCADA op-
eration and monitoring software package,
as well as a simple procedure (setup of a
DDE data exchange interface), you can
achieve high-speed communication, which
is particularly useful for:
・Daily/monthly reporting using
spreadsheet software
・PC-based computing system using an YS-net
operation and monitoring software package P C
Furthermore, you can carry out communi-
cation between YS170 controllers while the YS100 series
controllers are concurrently communicating controllers up to 16
1 2 3
(or 63) units
with a PC.
Applicable models:YS131/135/136/150/170
Total number of connectable controllers:
16 (up to 63 using optional tools)
■ Communication with a DCS
Periodic communication:16 loops/sec; 16
types of main YS100 series data items
A more advanced, secure control system can be
Message communication:Approximately 400
configured by integrating YS100 series controllers
types of main YS100 series data items
Requirements for PC: with a DCS.
IBM PC/AT or compatible model DSL-LCS
Microsoft Windows communication
*1
YS-net communication board
*1
YS-net DDE server
Software with DDE communication
function(Microsoft Excel, SCADA software
products, and so on)YSS50 Parameter
Definition File
SV/PV
SV/PV
SV/PV
burden of startup tuning work. 60 60 60
YS131/135/136/150/170 controllers
PV:
75.0
SV:
75.0
MV:
75.1
Pulse
This feature reduces instrumentation costs.
The YS100 series of controllers has been Two-wire
transmitter
designed to directly accept signals from field
sensors . This design strategy not only reduces
wiring costs but downsizes the instrumentation YS100
panel.
CPU 2 100.0
Reliable Design
PV:
75.0
SV:
YS131/135/136/150/170 controllers
CPU 1
for control
The dual-CPU architecture ensures
uninterrupted display of PV values by the
Hardware for
display CPU, and the controller can still be manual operation
operated manually even if the main CPU fails.