[STANDARD OPERATING PROCEDURE | Tort |
LIET PIT WATERPROOFING METHOD STATEMENT
1. Treatment for LIFT PIT (INSIDE)
* Surface cleaning by wire brush, removing loose mortar, dirt, grime etc followed by water cleaning using
cleaning agent.
+ Coving the stab and wall joint using polymer modified mortar.
* Sealing of cracks, voids, floor wall junctions, etc., with Protekta Sealant 500 modified mortar:
Porosity Reduction
* Spraying of Protekta Base which fills the fine pores with crystalline silicate growth,
‘Surface Preparation;
+ Brush application of Protekta Special Slurry which has a very special chemical, which impregnates
through pores and capillaries,
+ 1 coat of primes MYK Indufloor EPW 44
+ Bitumen Free P.U. (polyurethane) elastomeric waterproofing membrane system MYK COAT WPU
1K(E)on the concrete surface To be applied in as a coating to built a thickness of 1.2mm on surface
Prepared, fair faced concrete surface, later to be protected as per manufacturers specifications.
* Plastering the walls with rich mortar admixed with special admixture Protekta KR2 Emulsion,
* Providing a final coat of MYK COAT WPU 4K(E)taken over the coving