You are on page 1of 7

A.

Before configure, what you must to confirm and prepare :


1 .Control card: GIS

2. Resource card: MPRB

3. Backplane: MICS or another, you must to check from equipment site.

4. DIP switch 1£º2£º3£º4

OFF: OFF: OFF: OFF (1111) -----main shelf

OFF: OFF: OFF: ON (1110) -----slave shelf

5. MPRB: When in 1000M working mode, it can work with GIS.

X16 pin switch: Pin 1 and 2 are connected; it is in 1000M mode

6. Select Version Packets File:

Main shelf
 icsFpga.bin, icsSlav.bin, icsSlav1.bin, icsver.z, bootSlav.bin, bootIcs.bin

MP_CONFIG_FILE

 agcmd.cfg, ntimer.cfg,license.dat

ICS_sf (Slave shelf)


 icsfpga_sf.bin ,icsSlav.bin,icsSlav1.bin,icsver_sf.z , bootSlav.bin,bootics_sf.bin

CNIC
 bootcnic.bin, pp5.img

MPRB
 pp53.img, bootMPRB.bin

MPRB firewall
 pp53fw1.img,pp53fw2.img,pp53fw3.img,pp53fw4.img,pp53fw5.img,pp53fw6.img

GADLC

 bootGadl.bin,gilcaVer.z
7. Set ftp server username/password: su3/su3.

8. MG ip address, nexthop and vlan of VoIP, TID and RTP name; in-band ip, vlan, nexthop

9. Configure VOIP IP on SS ip address

B. Download the version


 Put one GIS only in the control shelf slot.
 Using RS-232 cable connect to PC and equipment console port. With’s’ into BOOT status.

P //show out-band ip, and ftp server ip

C //modify ip and username, password

 inet on ethernet(e) : 168.10.1.1/// 9 SLOT GIS OUT-BAND IP &


 inet on ethernet(e) : 168.10.1.2///10 SLOT GIS OUT-BAND IP
 host inet(h) : 168.10.1.100 /// PC IP

Username/password su3/su3

M, q //modify MAC, you can check from GIS card

[ICS Boot]: D //show the disk

[ICS Boot]: E C: //format the disk C

[ICS Boot]: E D: //format the disk D

[ICS Boot]: E E: //format the disk E

[ICS Boot]: U //update boot version

[ICS Boot]: T icsVer.z

[ICS Boot]: T icsFpga.bin

[ICS Boot]: T icsSlav.bin

[ICS Boot]: T icsSlav1.bin

Restart GIS. //CTRL+X

slave shelves only download icsver_sf.z, icsfpga_sf.bin, icsslav.bin, icsslav1.bin


 After three minutes

With PC IP 168.10.0.100

Telnet 168.10.0.1 8888

Password: zxmg

Set ftp server username/password: zte/zte

r07_pc2mp 168.10.0.100 ntimer.cfg

r07_pc2mp 168.10.0.100 agcmd.cfg

r07_pc2mp 168.10.0.100 license.dat

r07_pc2mp 168.10.0.100 pp5.img

r07_pc2mp 168.10.0.100 pp53.img

r07_pc2mp 168.10.0.100 pp53fw1.img

r07_pc2mp 168.10.0.100 pp53fw2.img

r07_pc2mp 168.10.0.100 pp53fw3.img

r07_pc2mp 168.10.0.100 pp53fw4.img

r07_pc2mp 168.10.0.100 pp53fw5.img

r07_pc2mp 168.10.0.100 pp53fw6.img

r07_pc2mp 168.10.0.100 gilcaVer.z

r07_pc2mp 168.10.0.100 epidll.bin

r07_pc2mp 168.10.0.100 epifirm.bin

r07_pc2mp 168.10.0.100 epifpga.bin

r07_pc2mp 168.10.0.100 epiver.z

 After download the version finished, power off equipment (each shelf) and restart with
msagreset.
C. Configure the data
Telnet 168.10.0.1 1123

MSAG#config

MSAG (config) #hostname ETC-BOLE-MSAG-TEST //hostname is equipment address name

ETC-BOLE-MSAG-TEST (config) #ag

ETC-BOLE-MSAG-TEST (config-ag) # add-rack rack 1 type 1 //you must select the right rack type

1 - STANDARD

2 - STANDARD_EX

3 - ONU100

5 - OUT50C

6 - OUT50D

7 - 23INCH_EX

ETC-BOLE-MSAG-TEST (config-ag) #add-shelf rack 1 physhf 0 type 6 //shelf type must be checked from
equipment site

5 - MICS_EX

6 - MICS_CTL

8 - ONU100

9 - OUT50C

10 - OUT50D

11 - MBSL_CTL

12 - MBSL_EX

13 - TPU_EX

14 - PP_EX

15 - DOUBLEPP_EX 15
16. - DOUBLEPP_EX

ETC-BOLE-MSAG-TEST (config-ag)# add-shelf rack 1 physhf 1 type 5

ETC-BOLE-MSAG-TEST (config-ag)# add-shelf rack 1 physhf 2 type 5

ETC-BOLE-MSAG-TEST (config-ag)# add-shelf rack 1 physhf 3 type 5

ETC-BOLE-MSAG-TEST (config-ag)# add-shelf rack 1 physhf 4 type 5

Add GIS card:

ETC-BOLE-MSAG-TEST (config-ag)# add-board-mics slot 9 type 3

ETC-BOLE-MSAG-TEST (config-ag)# add-board-sics rack 1 shelf 1 slot 9 type 2 hw1 8

ETC-BOLE-MSAG-TEST (config-ag)# add-board-sics rack 1 shelf 2 slot 9 type 2 hw1 9

ETC-BOLE-MSAG-TEST (config-ag)# add-board-sics rack 1 shelf 3 slot 9 type 2 hw1 10

ETC-BOLE-MSAG-TEST (config-ag)# add-board-sics rack 1 shelf 4 slot 9 type 2 hw1 11

Config MGC:
ETC-BOLE-MSAG-TEST (config-ag)#add-mgc mgcid 1 mgctype 1 mgcip 10.208.0.4 mgcport 2944

ETC-BOLE-MSAG-TEST (config-ag)#add-mgc mgcid 2 mgctype 1 mgcip 10.209.0.4 mgcport 2944

Config VoIP and manage ip:


 In-band management:

ETC-BOLE-MSAG-TEST (config)#vlan add 2300 //VOIP vlan

ETC-BOLE-MSAG-TEST (config)#vlan add-port 2300 port 0/9/2 untagged

ETC-BOLE-MSAG-TEST (config)#vlan add 2301// uplink port vlan

ETC-BOLE-MSAG-TEST (config)# vlan add-port 2301 port 0/9/2 tagged // 0/9/0 is uplink port, tagged or
untagged must be confirm.

ETC-BOLE-MSAG-TEST (config)#route interface ipaddress 168.10.19.13(NMS IP ADDRESS) mask


255.255.255.128 vid 2301

ETC-BOLE-MSAG-TEST (config)#route static ipaddress 10.0.0.0 mask 255.0.0.0 nexthop 7.7.7.99


VoIP:

ETC-BOLE-MSAG-TEST (config-ag)#add-mg protype 1 mgport 2944 mgcid1 1 mgcid2 2

ETC-BOLE-MSAG-TEST (config-ag)#add-VoIP-interface type 1 ipaddr 10.208.2.26 submask


255.255.252.240

ETC-BOLE-MSAG-TEST (config-ag)#add-VoIP-route nexthop 10.208.2.17

ETC-BOLE-MSAG-TEST (config)#vlan add 2102

ETC-BOLE-MSAG-TEST (config)#vlan add-port 2102 port 0/9/0 untagged //0/9/0 is uplink port, tagged
or untagged must be confirm.

ETC-BOLE-MSAG-TEST (config)#vlan voipmed add 2300

ETC-BOLE-MSAG-TEST (config-ag)#add-board-slc slot 3 type 26 //add alc board

ETC-BOLE-MSAG-TEST (config-ag)#add-board-slc slot 4 type 47 //add GILCA board

ETC-BOLE-MSAG-TEST (config-ag)#add-board-tslc rack 1 shelf 0 slot 17 //add TSLC board

ETC-BOLE-MSAG-TEST(config-ag)#add-slctermid rack 1 shelf 0 beginslot 3 beginindex 0 num 32 tmidfix


USER type 1

ETC-BOLE-MSAG-TEST (config-ag)#add-board-mprb slot 11

ETC-BOLE-MSAG-TEST (config-ag)#add-board-mprb slot 12

ETC-BOLE-MSAG-TEST (config-ag)#add-ipstermid slot 11 subcard 1 tmidfix RTP

ETC-BOLE-MSAG-TEST (config-ag)#add-ipstermid slot 12 subcard 1 tmidfix RTP

ETC-BOLE-MSAG-TEST(config-ag)#add-mednat slot 11 subcard 1 nicslot 9 inphyport 5 exphyport 5


exipaddr 10.208.2.26 udpport 8000

ETC-BOLE-MSAG-TEST(config-ag)#add-mednat slot 12 subcard 1 nicslot 9 inphyport 5 exphyport 5


exipaddr 10.208.2.26 udpport 10000

ETC-BOLE-MSAG-TEST (config)#eth-switch backup-type unit 0 type GEI

ETC-BOLE-MSAG-TEST (config)#port enable 0/9/2 // 0/9/0 is uplink port

ETC-BOLE-MSAG-TEST (config)#save
Restart equipment.msagreset

Telnet 10.208.2.26 8888

 H248s to check VoIP link.

If h248s is ok, get data to pc, and download standby GIS version, download the data to standby GIS.

Telnet 168.10.1.1 8888 and also use the wftp server.

 Read data£º

r06_mp2pc 168.10.1.100 E:/DATA/V0100/*.ZDB E:/V0100

r06_mp2pc 168.10.1.100 E:/DATA/V0101/*.ZDB E:/V0101

r06_mp2pc 168.10.1.100 D:/persist E:/persist

r06_mp2pc 168.10.1.100 D:/durable E:/durable ////168.10.1.100 is the IP of PC

 Write data£º

r06_pc2mp 168.10.1.100 data/*

 Delete data£º

r06_attr E:/DATA/V0100/*.* -R

r06_attr E:/DATA/V0101/*.* -R

r06_del E:/DATA/V0100/*.*

r06_del E:/DATA/V0101/*.*

r06_del D:/persist

r06_del D:/durable

You might also like