You are on page 1of 3

Baker Oil Tools Unit No.

10357 Date: July 1, 2004


Rev. New Page: 1 of 3
GAS LIFT Tubing Retrievable Equipment
TECHNICAL UNIT

BTR-1.0IM Internal Mount Conventional Mandrel


Product Family No. H86932

Description
The BTR-1.0IM Internal Mount Conventional
Mandrel can be made up as an integral part of the
production tubing (threaded tubing or attached to
coil tubing), be utilized between two wireline re-
trievable packoff assemblies or be installed in the
packing bore of sliding sleeves when preparing a
well for gas lift, chemical injection or other special
applications. This mandrel utilizes 1.0" flow control
devices. If the mandrel is used in gas lift opera-
tions, it can be used with injection pressure operat-
ed valves, production pressure operated valves or
reverse flow check valves. The valves are mount-
ed internally inside the mandrel which allows the
mandrel to be installed inside tubing or casing
where clearance is a problem.
The BTR-1.0IM is constructed of 4130 grade
material. Other materials are available to suit indi-
vidual well conditions

Features/Benefits
• Same mandrel can be used for either tubing or
casing flow
• BTR-1.0IM Internal Mount mandrels accept the
more reliable 1.0" tubing retrievable gas lift and
orifice valves
• Available in a wide range of sizes and threads
• Short length and large by-pass flow area result
in minimal pressure loss, even at high flow
rates
• Mandrel OD is collar OD or less
• Ideal for multiple string completions where
round exterior make them easy to rotate in
difficult situations
• Designed to hold up to 5,000 psi differential
pressure

Drawing No. 999-719

This document is and contains unpublished, copyrighted and confidential information of Baker Hughes, and is revealed for limited purposes only. This document
is the property of Baker Hughes and is to be returned to Baker Hughes on request and may not be reproduced, used or disclosed to persons not having a need to
know consistent with the purpose of the document, without the written consent of Baker Hughes. This document is not rented, loaned or sold, either alone or in
conjunction with equipment or product. © 7/1/04 Baker Hughes Incorporated.
Unit No. 10357 7-1-04 BTR-1.0IM Internal Mount Conventional Mandrel
Rev. New Page 2 of 3

sembly. The inside mounting of the valve prevents


WARNING passage of wireline tools through the mandrel.
Use of Baker equipment contrary to
manufacturer’s specification may result in In tubing flow applications, flow enters through
property damage, serious injury or fatality. the outside flow port of the in the nipple of the
mandrel, through the mounting lug and then up
Mandrel Application through the reverse flow check valve, through the
And Operation flow control device and into the tubing. In casing
flow applications, the flow is in the opposite direc-
The flow control device is installed into the 1/2" tion.
NPT mounting lug located in the pin by pin nipple
of the BTR-1.0IM mandrel. The nipple can now be
made up into the valve cover completing the as-
BTR-1.0IM Internal Mount Conventional Mandrel Unit No. 10357 7-1-04
Rev. New Page 3 of 3

BTR-1.0IM Internal Mount Conventional Mandrels

Assembly Drawing No. 999-720

Engineering Data For BTR-1.0IM Internal Mount Conventional Mandrels


Flow Area
Tubing Size Max OD Length
Square
And Joint (in.) (in.)
(in.)
1-1/4" NUE 10 rd 1.850 0.710 28.250
1-1/2" NUE 10 rd 2.200 1.250 28.250
2-3/8" NUE 10 rd 2.700 2.340 28.250

You might also like