You are on page 1of 2

MULTICHANNEL FLAW DETECTOR MODEL PI - D 08

Special Features:
8 individually programmable channels Two gates per channel Frequency Range 0.515 MHz by wide band amplifier Large CRT with bright display 4 digit 7 segment LED display to indicate Gain, gate, Range, Memory, etc. Free from distortion & parallax error. Selectable PRF 9 sets of Calibration memory Output for recorder available

TECHNICAL SPECIFICATIONS
Channels Frequency range Test range Linearity Sensitivity Suppression 8 channels multiplexed with all available parameters, can be freely programmed for individual channels. 0.5 to 15 MHz by wide band amplifier. 0-10 mm min., 0-5 M max. 4 step coarse selection and continuous variable fine selection. : Horizontal --- 1% Vertical --- 5% Maximum 140 dB, Variable in 1 dB step from 0 to 100 dB. Normal mode: Linear type. Continuous variable between 0 to 100 % full screen height. Gated mode: Linear type. Suppress unwanted echoes in gated area. Continuous variable between 0-100 % full screen height. Either or both can be activated. 2 gates per channel. Positive / negative logic selectable & display ON / OFF selectable. Gate start, gate width controllable between 1 div. To full screen width & gate threshold variable between 10 to 100 % full screen height. Audio & Visual alarm, Gate search & OFF selection. Audio Alarm mute available. 100 X 80 mm screen with internal graticule. Bright display, free from distortion & parallax error. 10 X 10 main divisions each with small sub divisions. 4 digit 7 segment LED display to indicate 1. Threshold, Rejection in % of full screen, 0-99 in9 step (10, 20, , 90). 2. Gain in dB, in 1 dB step. 3. Memory set no. 1 to 9. 4. Coarse range 1/5/25/100 cm. Range dependant, min. 200 mm & max. 3 M. Functional sealed touch control for all parameters. Visual indication of selected parameter. Slew Key UP / DOWN for function value change. 9 sets. All parameters can be stored in memory. Range dependant 10mm 1 KHz/Channel 50mm 500Hz/Channel 250mm 250Hz/Channel 1mtr 125Hz/Channel Setting for all parameters can be locked. 4 digit programmable password. Pulse Reflection or Pulse Transmission Factory set for T+R or T/R mode for individual channel. External 12 V DC, 2A, required. By flash LED indicator. Output suitable to record A-Scan pattern and instrument parameters. Sweep Less than 0.7 mm / 10 C. Up to 55 C 5 Kg. 400 mm (L) X 280 mm (W) X 120 mm (H)

Monitor

CRT Digital display

Pulse delay Keyboard Calibration memory PRF

Lock Test method Operating modes Power supply Power check Output Drift Temperature range Weight Size

You might also like