Model CUB5 ‐ Miniature Electronic 8‐Digit Dual Counter and Rate Indicator 
Installation Guide

C ULR US LISTED
IND. CONT. EQ.
E137808

See the Red Lion website at www.redlion.net for full user SPECIFICATIONS
manual. POWER: Input voltage range is +9 to +28 VDC with short circuit and
input polarity protection. Must use an RLC model MLPS or an NEC
SAFETY SUMMARY Class 2 or Limited Power Source (LPS) rated power supply.
All safety related regulations, local codes and instructions that appear INPUT CURRENT INPUT CURRENT
in the manual or on equipment must be observed to ensure personal MODEL NO. DISPLAY COLOR @ 9 VDC WITHOUT @ 9 VDC WITH
safety and to prevent damage to either the instrument or equipment CUB5RLY0 CUB5RLY0
connected to it. If equipment is used in a manner not specified by the CUB5R000 --- 10 mA 30 mA
manufacturer, the protection provided by the equipment may be
CUB5B000 Red (max intensity) 85 mA 115 mA
impaired.
Do not use this meter to directly command motors, valves, or other CUB5B000 Green (max intensity 95 mA 125 mA
actuators not equipped with safeguards. To do so can be potentially
harmful to persons or equipment in the event of a fault to the meter. DISPLAY: 8 digit LCD 0.46" (11.7 mm) high digits
Counter A Display Range: -9999999 to 99999999
Counter B Display Range: 0 to 9999999 (postive count only)
Rate Display Range: 0 to 999999
ENVIRONMENTAL CONDITIONS:
CAUTION: Risk Of Danger. CAUTION: Risk of electric shock. Operating Temperature Range for CUB5R000: -35 to 75 °C
Read complete instructions prior to
installation and operation of the unit. Operating Temperature Range for CUB5B000 depends on display
color and intensity level as per below:
INTENSITY
ORDERING INFORMATION LEVEL
TEMPERATURE
1&2 -35 to 75°C
DESCRIPTION PART NUMBER
3 -35 to 70°C
Dual Counter & Rate Indicator with Reflective Display CUB5R000 Red Display
4 -35 to 60°C
Dual Counter & Rate Indicator with Backlight Display CUB5B000 5 -35 to 50°C
1&2 -35 to 75°C
3 -35 to 65°C
Green Display
4 -35 to 50°C
5 -35 to 35°C
Storage Temperature Range: -35 to 85 °C

DIMENSIONS In inches (mm) Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 2.15" (54.6) H x 3.00" (76.2) W.

0.13 (3.3)

9876543.2
ON ECE

1.29 1 2 3 4 1.30 +.024


-.000
1.54 (39.1)
(32.8) (33 +6
-0 )
SEL RST

2.95 (74.9) 0.15 1.71 2.68 +.025


-.000
(3.8) (43.4) (68 +8
-0 )

-1-
 Bulletin No. CUB5 INST-A Effective 2018-05-29
Drawing No. LP1063

Operating and Storage Humidity: 0 to 85% max. relative humidity (non- IP65 Enclosure rating (Face only)
condensing) IP20 Enclosure rating (Rear of unit)
Vibration to IEC 68-2-6: Operational 5-500 Hz, 5 g CONNECTIONS: Wire clamping screw terminals
Shock to IEC 68-2-27: Operational 40 g Wire Strip Length: 0.3" (7.5 mm)
CERTIFICATIONS AND COMPLIANCES: Wire Gage: 30-14 AWG copper wire
CE Approved Torque: 3.5 inch-lbs (0.395 N-m) max.
EN 61326-1 Immunity to Industrial Locations CONSTRUCTION: This unit rated for Type 4X/IP65 requirements for
Emission CISPR 11 Class A indoor/outdoor use. Installation Category I, Pollution Degree 2. High
EN 61010-1: General Requirements impact plastic case with clear viewing window. Panel gasket and
EN 61010-2-030: Particular Requirements for Testing and mounting clip included.
Measuring Circuits WEIGHT: 3.2 oz (100 g)
RoHS Compliant
UL Recognized: File #E179259
UL Listed: File #E137808
Type 4X Indoor/Outdoor Enclosure rating (Face only)

1.0 INSTALLING THE METER
INSTALLATION INSTALLATION ENVIRONMENT
The meter meets NEMA Type 4X/IP65 requirements when properly The unit should be installed in a location that does not exceed the
installed. The unit is intended to be mounted into an enclosed panel. operating temperature and provides good air circulation. Placing the unit
Prepare the panel cutout to the dimensions shown. Remove the panel near devices that generate excessive heat should be avoided.
latch from the unit. Slide the panel gasket over the rear of the unit to the The bezel should only be cleaned with a soft cloth and neutral soap
back of the bezel. The unit should be installed fully assembled. Insert the product. Do NOT use solvents. Continuous exposure to direct sunlight
unit into the panel cutout. may accelerate the aging process of the bezel.
While holding the unit in place, push the panel latch over the rear of Do not use tools of any kind (screwdrivers, pens, pencils, etc.) to
the unit so that the tabs of the panel latch operate the keypad of the unit.
engage in the slots on the case. The panel
latch should be engaged in the farthest PANEL CUT-OUT
forward slot possible. To achieve a proper
seal, tighten the latch screws evenly until
the unit is snug in the panel (Torque to
approx. 28 to 36 in-oz [0.202 to 0.26 N-m]). 2.68 +.025
-.000
Do not over-tighten the screws. +.024
(68 +.8
-.0
) 1.30 -.000
+.6
BEZEL PANEL
NUT FASTENER (33 -.0 )
MOUNTING SCREW

MOUNTING CLIP

PANEL GASKET

2.0 SETTING THE DIP SWITCHES
To access the switches, remove the rear cover of the meter as SETTING THE INPUT DIP SWITCHES
described below. A bank of 4 switches is located in the upper right hand
The meter has four DIP switches for Input A and Input B that must be
corner. After setting the switches, install any optional plug-in cards before
set before applying power.
replacing the rear cover (see next section).
SWITCH 1
Input A MAG.
Input A SRC.

Input B LO Freq.
Input A LO Freq.

Warning: Exposed line voltage exists on the circuit boards. LOGIC: Input A trigger levels VIL = 1.25 V max.;
Remove all power to the meter and load circuits before VIH = 2.75 V min.; VMAX = 28 VDC
accessing inside of the meter. MAG: 200 mV peak input sensitivity; 100 mV
hysteresis; maximum input voltage: 40 V peak
ON
(28 Vrms); Must also have SRC switch ON.
REMOVE/REPLACE THE REAR COVER (Not recommended with counting applications.)
To remove the rear cover, locate the cover locking tab below the 2nd 1 2 3 4
and 3rd input terminals. To release the tab, insert a small, flat blade SWITCH 2
Logic
SNK.

HI Freq.
HI Freq.

screwdriver between the tab and the plastic wall below the terminals. SNK.: Adds internal 7.8 K pull-up resistor to +9 to
Inserting the screwdriver will provide enough pressure to release the tab 28 VDC, IMAX = 3.8 mA.
locks. To replace the cover, align the cover with the input terminals and SRC.: Adds internal 3.9 K pull-down resistor, Factory Setting
press down until the cover snaps into place. 7.2 mA max. @ 28 VDC max.
SWITCHES 3 and 4
HI Frequency: Removes damping capacitor and allows max.
frequency.
LO Frequency: Adds a damping capacitor for switch contact bounce.
Limits input frequency to 50 Hz and input pulse widths to 10 msec.

-2-
 Effective 2018-05-29 Bulletin No. CUB5 INST-A
Drawing No. LP1063

3.0 WIRING THE METER
WIRING OVERVIEW
Electrical connections are made via screw-clamp terminals located on standards of good installation, local codes and regulations. It is
the back of the meter. All conductors should conform to the meter’s recommended that the power supplied to the meter (DC or AC) be
voltage and current ratings. All cabling should conform to appropriate protected by a fuse or circuit breaker.

3.1 POWER WIRING 3.2 USER INPUT WIRING


DC Power Sinking Logic

}
INP COMM
+9 to +28 VDC: +VDC INP COMM Connect external switching device between the
Power Common: -VDC USR User Input terminal and Input Common.

INP B

INP A
USR

INP COMM
The user input of the meter is

INP B

INP A
internally pulled up to +9 to +28 V

USR
with 10 K resistance. The input is
active when it is pulled low (<1 .0 V).

- +
PWR COMMON +9-28 VDC

PWR COMMON +9-28 VDC

3.3 INPUT WIRING
CAUTION: Power common (PWR COMMON) is NOT isolated from input common (INP COMM). In order to preserve the safety of the meter
application, the power common must be suitably isolated from hazardous live earth referenced voltage; or input common must be at protective
earth ground potential. If not, hazardous voltage may be present at the Signal or User Inputs and input common terminals. Appropriate
considerations must then be given to the potential of the input common with respect to earth ground; and the common of the plug-in cards with
respect to input common.

Magnetic Pickup AC Inputs From Tach Generators, Etc. Two Wire Proximity, Current Source
INP COMM

INP COMM
INP COMM

Input A Input A Input A


INP B

INP A

INP B

INP A
INP B

INP A

USR

USR
USR

ON ON ON

* MAGNETIC PICKUP
* * AC
* *
1 2 3 4 1 2 3 4 1 2 3 4 2.2 k Ÿ
Resistor to Limit Current
to 2.5 mA MAX.

PWR COMMON +9-28 VDC PWR COMMON +9-28 VDC PWR COMMON +9-28 VDC

Current Sinking Output Current Sourcing Output Interfacing With TTL


INP COMM

Input A Input A Input A


INP COMM

INP COMM
INP B

INP A
INP B

INP A

USR
USR

INP B

INP A
USR

ON ON ON

* * NPN
O.C.
* * PNP * +5 V
O.C.
1 2 3 4 1 2 3 4 1 2 3 4
COMMON

PWR COMMON +9-28 VDC PWR COMMON +9-28 VDC PWR COMMON +9-28 VDC

Switch or Isolated Transistor; Current Sink Switch or Isolated Transistor; Current Source Current Sink Output; Quad/Direction
INP COMM

Input A
INP COMM

Input A
INP COMM

INP B

INP A

INP B

INP A
USR
INP B

INP A

USR
USR

ON ON
ON

* * * *
1 2 3 4 1 2 3 4
1 2 3 4

PWR COMMON +9-28 VDC


PWR COMMON +9-28 VDC PWR COMMON +9-28 VDC

Switch position is application dependent. Shaded areas not recommended for counting applications.

-3-
 Bulletin No. CUB5 INST-A Effective 2018-05-29
Drawing No. LP1063

3.4 SETPOINT (OUTPUT) WIRING


SINGLE SETPOINT RELAY PLUG-IN CARD ELECTRICAL CONNECTIONS
COM

N.O.

N.C.

COM N.O. N.C.

DUAL SETPOINT N-FET OPEN DRAIN PLUG-IN CARD ELECTRICAL CONNECTIONS


COM OSNK 1(2)
OSNK1
(30 V MAX.)

OSNK2
COM
Note: Output Common is not isolated from DC Power Common. Load must
be wired between OSNK terminal and V+ of the load supply.

3.5 SERIAL COMMUNICATION WIRING 3.6 USB PROGRAMMING


SERIAL COMMUNICATIONS PLUG-IN CARD USB PROGRAMING PLUG-IN CARD
COMM

COMM
COMM
N/C

N/C
N/C

N/C

N/C
RX
TX
A+
B-

6 5 4 3 2 1 6 5 4 3 2 1

RS485 RS232

RJ11 CONNECTOR PIN OUTS

LIMITED WARRANTY
(a) Red Lion Controls Inc. (the “Company”) warrants that all Products shall be free from defects in material and
workmanship under normal use for the period of time provided in “Statement of Warranty Periods” (available at
www.redlion.net) current at the time of shipment of the Products (the “Warranty Period”). EXCEPT FOR THE ABOVE-
STATED WARRANTY, COMPANY MAKES NO WARRANTY WHATSOEVER WITH RESPECT TO THE
PRODUCTS, INCLUDING ANY (A) WARRANTY OF MERCHANTABILITY; (B) WARRANTY OF FITNESS FOR A
PARTICULAR PURPOSE; OR (C) WARRANTY AGAINST INFRINGEMENT OF INTELLECTUAL PROPERTY
RIGHTS OF A THIRD PARTY; WHETHER EXPRESS OR IMPLIED BY LAW, COURSE OF DEALING, COURSE OF
PERFORMANCE, USAGE OF TRADE OR OTHERWISE. Customer shall be responsible for determining that a
Product is suitable for Customer’s use and that such use complies with any applicable local, state or federal law.
(b) The Company shall not be liable for a breach of the warranty set forth in paragraph (a) if (i) the defect is a result
of Customer’s failure to store, install, commission or maintain the Product according to specifications; (ii) Customer
alters or repairs such Product without the prior written consent of Company.
(c) Subject to paragraph (b), with respect to any such Product during the Warranty Period, Company shall, in its
sole discretion, either (i) repair or replace the Product; or (ii) credit or refund the price of Product provided that, if
Company so requests, Customer shall, at Company’s expense, return such Product to Company.
(d) THE REMEDIES SET FORTH IN PARAGRAPH (c) SHALL BE THE CUSTOMER’S SOLE AND EXCLUSIVE
REMEDY AND COMPANY’S ENTIRE LIABILITY FOR ANY BREACH OF THE LIMITED WARRANTY SET FORTH
IN PARAGRAPH (a).