ScanLog
Universal 4/8 Channel Composite DataLogger
with PC / Pen-Drive / Printer Interface
41/8 Channel Recorder + PC Interface
160 X 80 Monochrome Graphic Display & 6 Tactile Keys
418 Universal Analog Channels
Each Channel Independently Configurable (Jumper-ess) for
‘Thermocouples, RTD PU100, mV, V, mA
Fast Channel Update Rate : 250 m$ per Channel
Each Channel with Up to 4 Programmable Soft Alarms
Optional, 4 Common Relay Outputs for Alarms vith Front Panel
Acknowledgment Key
Optional 1 or 2 Exckation Voltage Outputs : SV or 24V (Isolated)
User Assigned Channel Names for Easy PV Wentiication
Huge Data Storage Capacity: Appx. 38,58,000 Records
Date /Time Stamped Process Value (PV) & Alarm Status
Recording for Each Channel
Continuous or Batch Recording with Programmable Recording
Interval
Event Generated Records : Pawer-up, Alarm Toggle, RTC |
Recording Interval Changed
Fre
21 GFR Part 11 Compliant Software with PC Interface
Version
PC Configurable HeaderiFaoter for Printer Interface Version
Easy Data Transfer to PC in Excel Format for Pen-Drive Version
‘Supply Voltage : 85 to 264 VAC, 50/60 HzSpecifications
| Operator Interface oe -
| Disolay | 160x 80 STN Monochrome Graphic LCD
Keys 6 Tactile Switches -
L |_PAGE, DOWN, UP, ENTER, Alarm ACKIVIEW, Scroll
Sensor Input
| | Thermocouples : J, K,T,R,$,B,N
RTD Pt100, 3-Wire
| Input Types Demy oto 80 mv
DC Volts O to 1.25V, 0 to 5V, 1 to SV, Oto 10V
| Doma 2 0-20.mA, 4-20 mA
“Recwacy | «#025% of madng S150
eee | + Cold-Junction Compensation for Thermocouples (Accuracy Better than + 0. 5°)
|_ Lead Resistance Compensation for RTD (Upto 22 Ohms in each lead)
Range | Thermocouple & RTD PtH100 : Refer Table-1
DC Volts / Current 30000 Counts
a | = __ See —_____}
Zero Offset | _User Adjustable over Full Range for Each Channel
ADC 16 Bit (+ 32,768 Counts), Si
| Sampling Time
| Input Resistance >10MQ
Common Mode
| > 1004B at 50/60 Hz
[ ESD:8KVEFT:2KV Surge: 1KV
[i First Order Analog R-C Low-Pass Fier —
| Alarms
Numbers, 4 Independent for Each Channel
| "type Process Low, Process High
| Programmable | Logic : Normal, Reverse
Parameters Hysteresis : 1 to 3000 Unit Counts
[Inhibit No, Yes
| Relay Change-over Contacts
Outputs (Optional) | Reelay-t to Relay-# Common for Alarm-t to Alarm-4 of All Channels
| Outputs
— 7 | Contact Type: Potential-tree Change-over Contacts
Relay | Contact Rating : 5A Resistive @ 120/240 VAC
Contact Life: > 5,00,000 Operations at Rated Voltage / Current
| Recordint
| Recording Capacity | 2 GB Flash Memory (Approx. 38,56,000 Records)
Recording Mode Continuous, Batch
[_ Recording Interval | Programmable from 1 Sec to 2 Hr 30 Min : 00 Sec| Mounting ~ ]
| 80 (H) X 160 ()X 144 (0), mm
| Terminals
Power Supply
eee
Line Voltage
‘Consumption
Physical _
Overall Dimensions
‘Switch Mode (SMPS)
Plug-in with Panel Mounting Clamps
Panel Cutout
Environmental
Operating Ambient
Storage Temperature
Atmospheres:
Pluggable Terminal Blocks
78 (H) X 154 (W), mm
“100 70°C
Not Suitable for use in Corrosive or Explosive Atmospheres. The
Panel in which the Instrument is Mounted must be free of Electrically
Conductive Pollution.
Systems (OS)
PC Interface
| Port S485, 2-wire, Half Duplex, Start-Stop Synchronized
Serial | Slave ID 210127
‘Communication Max. Units per Loop : 31
Supported Operating
‘Max. Distance 1200 Meters
+ Windows Vista + Windows 7
+ 32 bit /64 bit Windows 8 + 32 bit / 64 bit Pentium Dual Core
oan + 2.8GH2 Clock Speed + 2GB RAM
ae | + 40 G8 Hard Disk
e ‘Supports Multiple ScanLog on Single Installation
| + Auto Start-up on PC Power-up
+ Online Display of Process Values & Stored Records in Graphical & Tabular
Forms with Alarm Indications
| + SMS and/or Email Alerts on Alarm Conditions
PC Software + Mean Kinetic Temperature (MKT) Computation:
ipaenent | + Automatic Periodic Downloading of Records Stored in ScanLog
(USFDA, | + Access Control According to Authority Level
21 CFR Part 11 | + User Actions with Signing & Authorization
Compliant) | + Automatic Password Expiry
+ Manual & Auto Back-up Facility with Archiving
*+ Data Log Reports with User Configurable Title, Footer & Header
+ Data Log Report, Alarm Log Report, History Graph & Audit Trail Report in
POF & EXCEL formats
Audit Trail History of Critical Events & User Actions| Pen-Drive Interface
Pen-Drive ‘Support 7
| Read Set.te file
|_ File Operation White .csv les (Data Records)
Printer Interface
Printer interface Port | USB 20, Socket: Type A —_ _
i | Isolation Group | tla, , Material Group (DIN VDE otto, 1189)
Printer Support [| eonse Column Dot-Matrix (EPSON LX-300+Il or pr Equivalent)
aoe ‘T WellFormated, Date-Time Stamped Process Value & Event Records
nt Data “pe Tool for user Programmable Header & Footer)
Cua Cm uur eee a ur)
| Input Type Range (Min. to Max.) | Resolution
|__Type J Thermocouple (Fe-K) | Oto +960°C |
| Type K Thermocouple (Creal) L -200 to +1376°C
‘Type T Thermocouple (Cu-Con) 2001043856
bia E | ca
Type R Thermocouple (PLPLRH13%) Oto +1770°C
—————— —_—— 1°C or 0.1°C
Type S Thermocouple (PUPLRN10%) 0 to +1765°C (Programmable)
Type B Thermocouple Oto +1825°C
ae tO 82
‘Type N Thermocouple | Oto +1300°C
+
l
S.wire, RTD Pt100 | -200 to +600°C
Back Panel Terminations
4 Channel Without Alarm Relay Outputs4 Channel With Alarm Relay Outputs
'0¢ Excnaon Alarm Outputs -_
al 1 vo | [B]8s-265 vac
fad
Te Te ag tape ta tess ee ces
ottn
Eo
la cre ens cra crs ons.
IT) [Se] get] SS
aw
8 Channel With Alarm Relay Outputs
acre tse aa crs oe ais cnet