You are on page 1of 5
ScanLog Universal 4/8 Channel Composite DataLogger with PC / Pen-Drive / Printer Interface 41/8 Channel Recorder + PC Interface 160 X 80 Monochrome Graphic Display & 6 Tactile Keys 418 Universal Analog Channels Each Channel Independently Configurable (Jumper-ess) for ‘Thermocouples, RTD PU100, mV, V, mA Fast Channel Update Rate : 250 m$ per Channel Each Channel with Up to 4 Programmable Soft Alarms Optional, 4 Common Relay Outputs for Alarms vith Front Panel Acknowledgment Key Optional 1 or 2 Exckation Voltage Outputs : SV or 24V (Isolated) User Assigned Channel Names for Easy PV Wentiication Huge Data Storage Capacity: Appx. 38,58,000 Records Date /Time Stamped Process Value (PV) & Alarm Status Recording for Each Channel Continuous or Batch Recording with Programmable Recording Interval Event Generated Records : Pawer-up, Alarm Toggle, RTC | Recording Interval Changed Fre 21 GFR Part 11 Compliant Software with PC Interface Version PC Configurable HeaderiFaoter for Printer Interface Version Easy Data Transfer to PC in Excel Format for Pen-Drive Version ‘Supply Voltage : 85 to 264 VAC, 50/60 Hz Specifications | Operator Interface oe - | Disolay | 160x 80 STN Monochrome Graphic LCD Keys 6 Tactile Switches - L |_PAGE, DOWN, UP, ENTER, Alarm ACKIVIEW, Scroll Sensor Input | | Thermocouples : J, K,T,R,$,B,N RTD Pt100, 3-Wire | Input Types Demy oto 80 mv DC Volts O to 1.25V, 0 to 5V, 1 to SV, Oto 10V | Doma 2 0-20.mA, 4-20 mA “Recwacy | «#025% of madng S150 eee | + Cold-Junction Compensation for Thermocouples (Accuracy Better than + 0. 5°) |_ Lead Resistance Compensation for RTD (Upto 22 Ohms in each lead) Range | Thermocouple & RTD PtH100 : Refer Table-1 DC Volts / Current 30000 Counts a | = __ See —_____} Zero Offset | _User Adjustable over Full Range for Each Channel ADC 16 Bit (+ 32,768 Counts), Si | Sampling Time | Input Resistance >10MQ Common Mode | > 1004B at 50/60 Hz [ ESD:8KVEFT:2KV Surge: 1KV [i First Order Analog R-C Low-Pass Fier — | Alarms Numbers, 4 Independent for Each Channel | "type Process Low, Process High | Programmable | Logic : Normal, Reverse Parameters Hysteresis : 1 to 3000 Unit Counts [Inhibit No, Yes | Relay Change-over Contacts Outputs (Optional) | Reelay-t to Relay-# Common for Alarm-t to Alarm-4 of All Channels | Outputs — 7 | Contact Type: Potential-tree Change-over Contacts Relay | Contact Rating : 5A Resistive @ 120/240 VAC Contact Life: > 5,00,000 Operations at Rated Voltage / Current | Recordint | Recording Capacity | 2 GB Flash Memory (Approx. 38,56,000 Records) Recording Mode Continuous, Batch [_ Recording Interval | Programmable from 1 Sec to 2 Hr 30 Min : 00 Sec | Mounting ~ ] | 80 (H) X 160 ()X 144 (0), mm | Terminals Power Supply eee Line Voltage ‘Consumption Physical _ Overall Dimensions ‘Switch Mode (SMPS) Plug-in with Panel Mounting Clamps Panel Cutout Environmental Operating Ambient Storage Temperature Atmospheres: Pluggable Terminal Blocks 78 (H) X 154 (W), mm “100 70°C Not Suitable for use in Corrosive or Explosive Atmospheres. The Panel in which the Instrument is Mounted must be free of Electrically Conductive Pollution. Systems (OS) PC Interface | Port S485, 2-wire, Half Duplex, Start-Stop Synchronized Serial | Slave ID 210127 ‘Communication Max. Units per Loop : 31 Supported Operating ‘Max. Distance 1200 Meters + Windows Vista + Windows 7 + 32 bit /64 bit Windows 8 + 32 bit / 64 bit Pentium Dual Core oan + 2.8GH2 Clock Speed + 2GB RAM ae | + 40 G8 Hard Disk e ‘Supports Multiple ScanLog on Single Installation | + Auto Start-up on PC Power-up + Online Display of Process Values & Stored Records in Graphical & Tabular Forms with Alarm Indications | + SMS and/or Email Alerts on Alarm Conditions PC Software + Mean Kinetic Temperature (MKT) Computation: ipaenent | + Automatic Periodic Downloading of Records Stored in ScanLog (USFDA, | + Access Control According to Authority Level 21 CFR Part 11 | + User Actions with Signing & Authorization Compliant) | + Automatic Password Expiry + Manual & Auto Back-up Facility with Archiving *+ Data Log Reports with User Configurable Title, Footer & Header + Data Log Report, Alarm Log Report, History Graph & Audit Trail Report in POF & EXCEL formats Audit Trail History of Critical Events & User Actions | Pen-Drive Interface Pen-Drive ‘Support 7 | Read Set.te file |_ File Operation White .csv les (Data Records) Printer Interface Printer interface Port | USB 20, Socket: Type A —_ _ i | Isolation Group | tla, , Material Group (DIN VDE otto, 1189) Printer Support [| eonse Column Dot-Matrix (EPSON LX-300+Il or pr Equivalent) aoe ‘T WellFormated, Date-Time Stamped Process Value & Event Records nt Data “pe Tool for user Programmable Header & Footer) Cua Cm uur eee a ur) | Input Type Range (Min. to Max.) | Resolution |__Type J Thermocouple (Fe-K) | Oto +960°C | | Type K Thermocouple (Creal) L -200 to +1376°C ‘Type T Thermocouple (Cu-Con) 2001043856 bia E | ca Type R Thermocouple (PLPLRH13%) Oto +1770°C —————— —_—— 1°C or 0.1°C Type S Thermocouple (PUPLRN10%) 0 to +1765°C (Programmable) Type B Thermocouple Oto +1825°C ae tO 82 ‘Type N Thermocouple | Oto +1300°C + l S.wire, RTD Pt100 | -200 to +600°C Back Panel Terminations 4 Channel Without Alarm Relay Outputs 4 Channel With Alarm Relay Outputs '0¢ Excnaon Alarm Outputs -_ al 1 vo | [B]8s-265 vac fad Te Te ag tape ta tess ee ces ottn Eo la cre ens cra crs ons. IT) [Se] get] SS aw 8 Channel With Alarm Relay Outputs acre tse aa crs oe ais cnet [Rnatog inputs)

You might also like