You are on page 1of 1

An IMI Company

TITLE Spec No.: SI573.08r1en


Service Instructions for Revision: 1
VLBn Effective Date: 2012-05-31
Page: 43 of 55

11.2 Disassembly of OP spray nozzles


1. Unscrew all nuts and washers and remove flange.
2. Loosen and remove nozzle holder, spacer ring and packing by mounting a threaded bar in the
center hole of the nozzle holder and pull it out.
3. Spray atomizing nozzle is locked in position by means of lock washer which is bent upwards
against one of the flat sides of the nozzle. Release the locking by bending back the lock washer
and unscrew the nozzle.
4. Check the nozzle for obstruction caused by dirt particles. Clean if required. Make sure the water
channels in the nozzle are open. Check the condition of the spring as well. If the seat surface is
damaged or the spring is worn ± replace the complete nozzle.

NOTE! The nozzles might have been marked and must in that case be remounted in the same
position.

NOTE! Cleanliness is very important when working with nozzles.

Threaded bar

Lock washer

Figure 30 ± Cross section of spray nozzle

This document contains proprietary information with all rights and titles reserved and may not be reproduced, disclosed or used in whole or part without