12 Maintenance
12.1 Inspection

12.1.1 General
The valve body inside and the internal parts of the valve must be inspected periodically according to a
Plant Inspection and Preventive Maintenance Plan.
A first inspection is indicated at the end of the commissioning period. Inspection of all internal parts of
the valve should be carried out.
For service and maintenance of Grafoil stem seal ± see SI500.11.
Cleaning methods for steam pipe systems ± see SI500.10.

Check frequently
x the pressure control system
x the temperature control system
x that the cooling water cuts off when the steam valves closes

Check periodically
x that the preheating/draining functions and that the insulation is undamaged
x the condition of actuator, positioner and other actuator components
x that the area around the valve is kept clean and free from foreign particles