PANEL DETAILS & SPECIFICATIONS SPECIFICATIONS 1199 ‘The BEAR CUB 750rsv Infant Ventilator Performance Characteristics and Specifications Inspiratory Pressure Ventilator Rate. Inspiratory Time. Base FLOW ssn Inspiratory Flow... Assist Sensitivity. Volume Limit’ Audible Off (Volume Limit. az LED On/Off Manual Breath... at so Over Pressure Relief... 2 15 to 75 cmH20 % 02. ee 21 to 100% Apnea Alarm. 5, 10, 20,30 sec Alarm Loudness. soln. to Max, 60 to 75 db(A) Alarms Low PEEP/CPAP. a : swn5 to 30 cmH20 High Breath Rate. 1-3 t0 255 BPM Low Minute Volume Off to 99 LPM High Pressure Limit. 110 £0 75 emH20 Failed to Cycle. LED On/Off Low Gas Supply . LED On/Off Patient Circuit Prolonged Inspiratory Presswe Apnea, Pressure Settings Incompatible Flow Sensor.. Alarm Silence. Visual Reset. Line Power... Low Battery. Monitors Breath Rate. Breath Type (Patient initiated), Inspiratory Time.. : Expiratory Time... LE Ratio . Peak Inspiratory Pressure. Mean Airway Pressure. PEEP. Air Pressure . 02 Pressure Minute Volume ‘Tidal Volume (Exhaled), Tidal Volume (Inspired). YoLeak LED On/Off selaeaeeu Green/Red LED - seenennnnanens LED On/Off sa 0 255 BPM Proximal Airway Pressure... vn=10 to 100 cmF120 Hourmeter. " von €0 99,999 hours. Test - Push Button, Battery nn [LED On/Off “US, Patent No.5, 540,220 53 SPECIFICATIONS PANEL DETAILS & SPECIFICATIONS eee ees The BEAR CUB 750rsv Infant Ventilator Performance Characteristics and Specifications Preset Values Minimum Expiratory Time wn 150 milliseconds Minimum Inspiratory Time.wnnnovuesnn ‘0. seconds| Maximum Inspiratory Time. : ‘nnB.10 seconds Maximum settable EE Ratio eee Tolerances Monitors: Breath Rate.... : vtec 1 BPM of #20 msec, whichever is greater Inspiratory Time. “002 sec Expitatory Time <= 0.02 see EE Ratio £0.1 or + 20 msec (on the calculation based on the monitored, inspiratory and expiratory times), whichever is greater Airway Pressure (continuous) . 2 LemFEO (-10 to 20 em:0) 2 emH.O (20 to 65 cmF:O) + 3.cmH.O (65 to 100 cmH.) Peak Inspiratory Pressure.. : suc 2 EMELO or # 5%, whichever is greater Mean Airway Pressure... +2emH.O or = 3%, whichever is greater PEEP... = 2emELO or = 5%, whichever is greater Air/O: Pressure. natant 5 PSI Minute Volume . : "Accuracy is based on the Tidal Volume and Breath Rate monitors Inspiratory Tidal Volume. “ont TmnL oF = 10%, whichever is greater Expizatory Tidal Volume. % Leak “i UmL or = 10%, whichever is greater £ LmL or = 2%, whichever is greater (when compared to the Inspired and Expired Tidal Volume monitors) += 2% of reading Hour Meter -n Alarms!Limits: Low PEEP/CPAP. 2 2emH.0 High Breath Rate. +1BPM Low Minute Volume : 210 mL/min (0 to 99 mL/min) £0. L/min (0.1 to 9.9 L/min) High Pressure Limit + 4cmH.O Prolonged Inspiratory Pressure. a 2cmH.O ‘Volume Limit. sn £ 2mL or + 10% of setting, whichever is greater Apnea... = 1sec Maximum (Pop-off) Pressure =4cmH.O Controls: Ventilator Rate “#1 BPM or = 20 msec (applied to the breath interval), whicheveris greater Inspiratory Time eno 0.020 see (0.10 to 0.50 sec) 0.025 sec (0.50 to 3.00 sec) Assist Sensitivity smn Not a calibrated scale PEEP/CPAP and Ipiratory Pressure Repeatabil LomH.O or # 5%, whichever is greater (breath to breath) Base/Inspiratory Flow. 0.5 LPM or + 10% of setting, whichever is greater (0 to 60 cmH:O) LLPM or +10/-15% of setting, whichever is greater (60 to 72 cmH:O} Oxygen %. 23% Emissions/Susceptibility ‘The ventilator has been tested to conform to the following specifications: MIL-STD-461D:1983, MIL-STD-462D:1993, ENSSOLL:1991, IEC 1000-4-2:1994, IEC 1000-4-3:1994, IEC 1000-4-8:1994, IEC 1000-4-5:1994, QUAS-STATIC:1993, ‘This ventilator is designed and manufactured to comply with the safety requirements of IEC 601-1, IEC 601-2 CAN/CSA-C22.2 No. 601:1-M90, and UL 2601-1. 5a nis PANEL DETAILS & SPECIFICATIONS SPECIFICATIONS The BEAR CUB 750:sv Infant Ventilator Performance Characteristics and Specifications RS-232 Bi-Directional ‘Analog: (see page 5-29) Proximal Pressure... : 10 to 100 em#20, 1 emH20/25 mv Proximal Inspiratory Expiry Flow. 40 (expiratory) to 40 (inspiratory) LPM, 1 LPM/S0 mw Machine Delivered Flow. “0 to 30 LPM, 1 LPM/50-mv Breath Phase 0 sn “Logic” signal; 0,5V Remote Nurse Callnennuonimnaninnaninnseaninnnainn(S ADS MAX at 24-vde Preumatic: ‘Auxiliary Blended Gas Outlet 2 7 t017 psig, 0 to8 LPM KPa (48 to 117) Inputs Electrical: Supply Ratings Voltage: 100V 80 to 110 VAC i20V 95 to 135 VAC 2300 176 to 264 VAC 240v 192 to 264 VAC Current: 100V 1.0.4 maximum s20v 1.0 A maximurn 2300 05.A maximum 2400 05 Amaximum Frequency: 100V 47 065 Hz soy 55 to 65H 230 47 to 65 Hz 240V 47 10 65 Hz Fuses: 100/120V T05A,5x20 mm 230/240 70.25 A,5x 20 mm * For 220V operation, set the power entry module selector switch to 230V setting. Pneumai (Oxygen and Air. eee -nninnn80 to 80 psig, 50 LPM Supply Ratings KPa (206 to 551) 11/99 55 SPECIFICATIONS PANEL DETAILS & SPECIFICATIONS The BEAR CUB 750rsv Infant Ventilator Performance Characteristics and Specifications Physical Dimension and Shipping Information Ventilator Weight... 30 lbs, 13.6 kg Graphics Display Weight. 5.5 Ibs, Pedestal Stand Weight 9 Ibs, Compressor Weight... 110 Ibs. Ventilator Dimensions eae Graphics Display Dimensions ... Pedestal Stand Dimensions ‘Compressor Dimensions... Veto Wx10"D x11" 3" Wx2.5" Dx9.5" x 40.5" H Wx215'Dx36"H wwAO Ibs., 18.2 kg Graphics Display. “a1 Ibs. Pedestal Stand acm 2 Ths. Compressor “122 Ibs. Ventilator 8° Wx 18" Dx 19"H __ Graphics Display. eee “16 Wx 13" Dx 1" | Pedestal Stand... z 25° Wx 5" Dx45"H Compressor. Wx22"Dx0"H Environmental Specifications ‘Temperature: Storage and Shipping eno 31 to 158° F (-40 1070" C) Checkout and Operating sr “30 to 104° F (10 to 40°C) Altitude ‘Checkout, Operating, sna t0 9,000 feet (14.7 to 10.5 PSLA/760 to 543 mim Hg) kPa (101 to 73) Humidity: Storage and Shipping... i : sweat) t0 99% Relative Humidity — Non-condensing Checkout and Operating... nnnn

You might also like