You are on page 1of 8
Pw ST ADVANCED SOLUTIONS FOR SCIENTIFIC DISCOVERY Product Catalogue Fourth Version LAMINAR FLOW CLEAN BENCHES Labwitaminar flow clean benches offers 2 series of igh effiency products designed to protect equioment and ther contents of the work zane from particulates, for applications sensitive to such contamination. Its ideally sulted for use with non-hazardous contaminants and when fexible access o the equipment in the work zone is desired ‘These laminar flow clean benches are availabe in premium and economic ranges, each range with airflow pattern ‘options (vertical and herizontal, working surface width options (ram 300-1800mm) and working sides options {single and double sided working surface), [ae — | a a Premium VS Economic while the economic range features all basic functions of classic type o* laminar flaw clean bench, the premium range has renowned forts patented HEPA iter monitoring system, which monitors the status of the HEPA fiker every time before each operation, and alarms tre user in case its broken, expiring or overloaded. Therefore, the integrity of the key component ofthe clean bench is well under control and the security of experiment and samples involved are assured Refer tothe table for more information ofthe Premium and Economic ranges {abwit Laminar Flow Cabinet _ Premium Range (2HH-C3€) Economic Range (H-Cmr) Yes i staat ig Fer Mang rte | erste |" Control panel type | @ eld adjustment | Sis 755 elcty dpay | Yes We Velcty sensor | Yes sindard Me Time dock [15 1 Constant velocity control [Ys We Fier pressure diferent Display |= te Wight type | Qomitiatioeng gen Vertical Flow VS Horizontal Flow + In all madls, iris taken in through a presiker and then passed through @ HEPA iter + In horizontal low model, tered airis passed through the main chamber, and finaly exhausted through the back ofthe working chamiver with Forizontal ar low , In vertical flow models, tered airs craw out from the celing of ‘the working chamber, and creates the vertical ar down flow across the chamber area » Onthe horizansa low made, aie flow creates less turbulence at the work surface compared te vertical Tow ‘models as the airflow smoothly pass across the cham: ber area rather than directly impinge upon the working > Airflow in a horizental low clean bench is blown directly towards the user, whereas the airflow in a vertical flow dean bench strikes the working surface fist and exits towards the user indirectly, Herein, it should be noted, neither laminar flow type of clean benches offers any operator protection » Large or tll equipment in a horizontal flow clean bench wil interrupt the alow more than in a vertical fow ‘model This may create more turbulence and “dead” spots where airflow is lover than elsewhere, While verticalfow lean benches are not so impacted oy large equip Ream Dawn Fa, ugh PAF utlow Boe + | a 5 tin |Roem Ai Drawn oy an Trough shania A Otto ‘eePaFier Vertical Models Horizontal Models 6 Fluorescent Lamp uvtamp ‘Window Sash Time Cock Timer Pressure Differential Display Velocity evel Display ‘Constant Velocity Control Velocity Display Velocity Stopes Sting HEPA Breakage Alarm HEPA Fier Invaldation Alarm LED Display Leo display Double sided Clean Bench Mede! Summary Single Sided Horizontal Flow Vertical Flow 1800 1500 ‘400 120 300 Work Surface Width (mm) Model & Features acr068 aa-c1098 yc acr58 cr yHc098 yc TH-c1098 yeas aapecrt03¢ aypecrrnec Pend aapecrttac aapcr208¢ aapeeretae aapecat03¢ aypvearnac Y any" 09¢ bee PREMIUM LAMINAR FLOW "i ACT Clean Benches i LABWIT premium vertical Now clean bench isa series of high air puniying equipment with an intellectualized control system to ensure a clean working environment. These units ae designed for a particlefree, bacter aree clear-air erwi- ronment whicn is used for laboratory work testing manufacturing, inspection or pharmaceutical procedures under ISO Class 5 conditions ta prevent airborne contaminations. They are economical lightweight and are available in a variety of sizes, The patented HEPA fter monitoring system features an automatic fier integrity test, called “Self Validation Test, making sure the HEPA fiter is integral and vali, hence the working room is properly protected every ime before opera tion is started During operation, room air fs dravn throug” a pre fiter inthe top ofthe cabinet to trap large particles. Air flows through a HEPA ker and is blown vertically over the work area. The postive pressure laminar airflow provides procuct protection within the work area. The HEPA-jtered air prevents contaminants from entering the work area and provides a part cu late-fee work environment that minimizes cross contamination, » Automatic HEPA iter integrity test monitors and alarms» Standard with high efficiency quartz UVVlight. against HCPA iter oreakage and overloading, » Stainless steel work surface + LCD screen displays the actual speed, diferential pressure, flow volume and HEPA status. » Combined base stand with castors. > A presfiter trans large particles to extend the fe of the» Front sash window easy for random postioning, HEA tke. » Glass windows on leftright side » A quiet and with stepless adjustable speed internal blower provides ar velocity. » An extra power point is included as standara, » Glare free fluorescent lamp, Time clock cisplay » Operation mode choices of automatic and manuel 67 a a a a a Medel cat0s¢ cane crs etn. c1209¢ cre 2109 ane Fin Mode [ etal ew il Worksie men [Sede [Stk Svak [Sede _[0ome [Oni [one [bale Work Are | 5 ia "so 1800. « « 00 Rents oom 0 mo [xe 2 Tier nite ae Ten gE Fier ing [eS OTTE Work RT| sac ac eat | ese6ra ie) Weleay recon | “iba ‘urination [enh 300H ight | Sania TAD re tie won [ames [amae [nn | ncn 7 eierions we foe fae fae [im fis Tr Beso Taare [Ra — oma Pa temewsond |r [area [ne [one [ie [aime [aos Taig Dies | TGR] [TTD | cars omen [co [isa [ve” [wo (non [awe [atmo a amen us a0 a8 2 2a a6 28 ee | === Powe [30 [eps [ae To eat | TAT Approval | ci 50 ore norton TacrHC rari awernc racic yncran8¢ TMH | ten, Menu Dave sce, eal Fw sn Bench THC zyyecaiae io Sle 53, arora a ean Beh je, renin Sg de, ra Flaw ean Ber aH 1098 . ECONOMIC LAMINAR FLOW Clean Benches | THH-C2108B THHA21128 LABWIT economic laminar flow clean bench is the basic models of the premium unis, which are designed for a parti- cle-free, bacteria-fee clear-air environment which is used for laboratory work testing, manufacturing inspection or phar- maceutical procedures under ISO Class § conditions to prevent aifborne contaminations. They are economical lightweight, and are avellable in a variety of sizes. During operation, room air is drawn through a disposable pre fer in the top of the cabinet to trap large particles. Air flows through @ HEPA Mker and is projected vericalyorizontally ove the work area, The positive pressure laminar air- flow provides procuct protection within the work area. The HEPAfikered air prevents contaminants from entering the work area and provides a part culate-ree wark erwironment that minimizes cross contamination, > LED algial indicator with touch pad controler » Glare free fuorescent lamp, > HEPA fer tested to typical efficiency of 99.97% for» Standard with Wight contaminants at 0.3 microns in size » Stainless steel work surface » Class 100 150 5 ar cleanliness within the work zone as per Fed Std 209. » Combined base stand with castors. » A disposable pre-iter traps large particles to extend the» Glass windows on lefvright side, eof the HEPA Ste » Fron: sash window easy for random postioning » Aquiet and with 7 steps adjustable speed internal {unavailable on horizontal models ZHIH-C21098, blower provides ar velacty contro. ZHH-C21128), 6 Model zy ma 24 24 mH cre cine carseat czas ay crue 2 ai088 24 ear ‘low Mode estonia Work sde (rm) Sra ink Sige Sige Dae Dae ora Work Area Width (rm) Py 00 so we oo 00 Fier Moitring system We Fier fleney eo Cas 00505 Workroom Air Velcty 03.06 ites adutate) Velocity Precision ination Wight HEPADiferentil Pressure Work Ace Dim. (eu (W204) a sosasss | vanes | sows ‘as sons20670 reangasro ‘xterir Dim. (en (x04) ansT0 | rzecanT0 | tezoaerTe | saozenren | somasoaD ‘songre0 sooo eaten ate Packing Dim. (ex (x08) woe) ‘ratoaso | roountoo | rronsantan ‘sanssa60 wostost9 ‘este ‘Shipping Volume (m3) 5 m a 3 281 Net Weight (i) Ey a 1m Bs Power (0) et @ ED fo ‘etiety ‘aproval TAHTAO8B | Sen eric Sa Se Via ZAHA [ len Coo Sg ie, el TA-11HB | Tim Frome Se, era Tow Cen Order information zh 2 Emi Sng Ses Vet TaH-r2096 | Ser Ecc Daud Vera Hew Chan enh 7 F tr Eero sed Val chan zaph-21098 | Sen Eo Ses Henna ow Chan enh ayia nan [ tc Gosnell ow dean Banh 7

You might also like