aa COOPER POWER Chi ris piealen bagi SERIES 200 A 15 kV class loadbreak elbow connector with optional integral jacket seal General Eston’s Cooper Power™ series loadbreak elbow ig a fullshialded and insulated plugen t n for connecting underground eable transformers, switching cabinets and junctions with loadbreak bushings. The elbow ‘and bushing insert comprise the essential components of allloadbreak connections ‘Tho loacbreak olvaw connector is fully rated 200 A switching device, designed in accordance t IEEE Std 286™-2006 stancara, Eaton's loadbraak elbows are molded using high qualty peroxide-cured insulating a —_— conducting EPDM rubber, Stancard fos include « coppertap connector, tn-lated copper loacbreak prove with an ablative are-follower tip and starless steel reinforced puling-eve. An optional capacitive test point, made of corrosion resistant plastic, availabe for use with fault indicators (see Catalog Sections CASZ0002EN anc Casz0003=N) Cable ranges are designed to accent a wide range of cable conductor and insulation sizas with just three elbows and accommodate cable Tranufectured to either AEIC or ICEA standards The coppertop compression connector isa — standard iter to transition from the cable to the loadbreak probe. An aluminum ermp barrel is inoiaewelded to @ copper lug. The aluminum barrel matas the connector easy copper lug ensures # relable, ight {Phot on let's shown with the integral jacket seal without test point, Photo on ight 's shown without jacket seal with test point) Optional integral jacket se The optional integral jacket seal provides a quick and easy means to sealing the cable jacket to rovent moisture ingress. ur jacket soalis molded to the loadbreak elbow eliminating the need for separate cable sealing products. I's available with braided ground strap/oleeder wi for terminating Tape shielded cable, (See Figure 4 E.T-N Powering Business Worldwide Catalog Data CA650062EN 200 A 15 kV class loadbreak elbow connector with Effective February 2019 optional integral jacket seal INSULATION Highualty peroxd riled n-neuse for ‘outed EPDM rubber formulate, naistent and relate {eld Der‘ormance, SEMI-CONDUCTIVE SHIELD Fighqualty peroxde-cured EPOM rubber provides protective SEMI-CONDUCTIVE INSERT: ighavalty peroxde.cured EPDM rubber (raates a smooth surfaoe around the current interchange” te evenly dstibute clocical stress thin tre Insult on, eadifont shield that meets requirements of IE=E Sta 582"™2007 Stancord __ LOADBREAK PROBE Tirsloted copper arabe with are-abative ta ) Ieee proves ‘ependable loadbreak simtzhing character ‘switching operations. ‘TEST POINT (OPTIONAL) Corosiones'stant conductive onsistent capacitive mot fault naietors ‘snd-cetermining tte court's energized {cap not shown CCOPPERTOP COMPRESSION CONNECTOR Inerisnalded akinarn bate andsneaded copper lig mates onmaing easy and ensures a tgnt. rl sble tlactreal eannoet on wth losooreae probe, "~___crounoine Tass Iolded into semicanductive shioks forthe attachment ofa ground wie romantan desattont sary. LonpeR Uvresstan phase rated and i itd veplaceetie, , @ DNDUCTIVE INSERT =NDS Encapsulated with ingubting rubber. Reduces table extrusion and cistorson that can be caused by thermocyelng. Miigates the effects ofthe slecvicalstresaas along the cable to ebow nter'ace, greatly redueng the possiblity of mterface Wacking, + TIONAL INTEGRAL JackET SEAL The optional ntegral jacket seal prowiias a cuick and easy means to sealing ‘he cable jacket to prevent moisture Ingress Also avaleble with bradee ground stapibleeder ite fot terminating tape shelded cable. Figure 1. Cutaway drawing shows design detail 2 woaeton comicooperpowerseries 200 A 15 kV class loadbreak elbow connector with Catalog Data CA650062Er optional integral jacket seal Effective February 201 om [em Se $3 | abn 83 een sa {106 mm) +l -s6 oem | ——+ se 168 mm) sm le | etn j— ss UL Figure 2. Elbow profile and stacking dimensions as referenced in IEEE Std 386™-2006 standard. Installation Table 1. Voltage ratings and characteristics Cablo stripping and scoring tools, available from various tool Description wy manufacturers, are recommended for use when installing loadereak "Sanda wllage char ‘elbows. After preparing the cable, tne elbow housing is pushed Mair rating prasoteprase aa Conta the cable. The loadbveak probe 's threaded into the coppertop “Maxima tng pave tg Ba ‘connector using the supplied installation tool or an approved sina pss s ‘equivalent. Use a hotstick to perform loadmake and loadoreak A | Also witht au ‘operations. Refer to Installation Sheet VINGSOOOBEN for detals, de 1S Minute withstand sa BIL an allwave cet S Production tests Minivan eorra vohage vel i Tests conducted in accordance with IEEE Std 386™%2006 standard: _Votoge ratings on choractratie aren aecordonce with IEEE Std 9862006 + ac 60 He 1 Minute withstand Serer 2ak + Minimum corona voltage leve Table 2. Current ratings and ch 1k Description + Test point voltage test Tests conducted in accordance with Eaton requirements: Swiching Fault cba 0.000 A ns syrnat “10 + Physical inspection ssutchng operas Periadic dissection Traine 000 As se Periodic fluoroscopic analysis 500 As serial for 808 Sand Catalog Data CA650062EN 200 A 15 kV class loadbreak elbow connector with Effective February 2018 optional integral jacket seal Ordering information METAL NEUTAAL a OR SHIELD « The elbow kis are packaged in a heavy duty DIAMETER over OIAMETER OVER polyethylene bag. There are 20 bagged kts to OUTER GAGRET suation INSULATION 8 carton, Individual boxed Kits are also avalable by special part number. To order a 15 kV Class loadbreak elbow kit follow tne easy steps Below. P conoycTor Each kit contains + Starr ow ody rE Boy wi ZZ = + Copperton Compression Connector + Losdoreak Probe Probe Installation Too! Figure 3. Illustration showing typical construction of high voltage underground cable. + Silicone Lubricant + Mastic Strips (Jacket Seal Elbow Only} + Installation Instvuction Sheet STEP 1: Determine the cable's diameter over the electrical insulation as shown in Figure 3 including tolerance from cable manufacturer. Then identify @ cable range from Table? «able 3. Cable Range Code (Insulation Diameter) for tat brackets te mnirmurm and maximum insulation lameters. sdbreak Elbow Select the CABLE RANGE CODE ‘tom the far ignt column Inchon atimecere cable Ran STEP 2: Icersity the conductor size and type in Table 4 and select _0a88 126-148 ota" the CONDUCTOR CODE from the far right colurtn, 166-7 coe STEP 3: For an elbow kt with a capacitive test point order 155.248 1 Taha oo [caste nance | | conoucror ‘CODE ‘cove D0" 1.2207 728-200 DD i SW cab ade, Toran ntagraljackel seal elbow fit wits capacitive test point order: jpryryan LEJ215 |casue nance] | conouctor | T ‘cope "cove, For an elbow kit witho capacitive test point order: LE215 | caste nance] | conouctor ‘cope ‘CODE For an in al jacket seal elbow kit wit out a capacitive test point LEJ215 caste rance| | conpucton ‘CODE. ‘cove For an elbow kit without a compression connector, use “00” for the conductor code, For an elbow kit with a hold down bail assembly included, insert a "BY after the test point option code. ‘Step 4: For optional braided ground strap/bleeder wire for terminating tape shielded cable, nsert “GS” after test point ancior ball option code. (Integral Jacket Seal Elbow Only) ‘Step 5: (Optional For an elbow kit individually packaged in a cortugated cardooard box, insert an "X” as the last character in the 200 A 15 kV class loadbreak elbow connector with optional integral jacket seal Table 4. Conductor Size and Type Eegetor No comer 00 & z ot e = a @ 2 z ® oe a = cI a @ # ry © 5 mo 7 = oF 12 9 0 40 7a" 120 camponed endo EXAMPLE: Selact an integral jacket seal elbow kit with a capacitive test point for use on 2 #1 compact cable with @ minimum insulation clameter of 0.770" and a maximum diameter of 0.830 STEP 1: From Table 3, identity the cable range 0.750"—1.080" and Select the "eG" CABLE RANGE CODE, STEP 2: The conductor size is @ #1 and the type is compact, tify #1 and Tale 4, under the column "Compact or Solid select the “04” conductor code. STEP 3: Order catalog number, Lesa1sccoat Catalog Data CA650062Er Effective February 201 Catalog Data CA650062EN 200 A 15 kV class loadbreak elbow connector Effective February 2019 optional integral jacket seal Table 5. Replacement 2.88" Long coppertop connectors Table 6. Replacement parts Conductor size Deserption Catalog number ‘Concentric er Compressed Compact or Solid Hold dona assent 2eRRIEICOTS Awe. a Cable Aapier Vor use with "O> Ebaw ze ol, = 7 = 5 — S85 cans, 15" — as cna “ 6 2 aoreak band package of 25) Zeer & 25 e 8 Probe «it nduges Poe, Itlaton ool Skane PTE @ B a = [avert ntastion eration Ses a = 10 © 02005 Teatrak probe stallion ol FRAT 1 © 0 CLRo06T ‘STzgne Grease 1780 be gras) 20 7 = ce2c0rr Eeetbe 180 gens) 30 = oaR008T Telos wounded, Conatant oc ing ad ware GRDBRAIDAT m7 = ccao08H % i Tamed tea oh Not: Coperpcoszsin cnet mayb sh uit ad cope cate Er Accessories Figure 4. Braided ground strap accessories (see Table 6), Figure 5.5 KV cable adapter (see Table 6). assembly (see Table 6) 200 A 15 kV class loadbreak elbow connector with Catalog Data CA650062Er optional integral jacket seal Effective February 201 This page intentionally left blank Catalog Data CA650062EN 200 A 15 kV class loadbreak elbow connector with Effective February 2019 optional integral jacket seal

You might also like