Ground floor Beam -[A-B]

0.4 d = 0.365 m

0.2
Negative Moment -73.14 kn-m
Posetive Moment 51.62 kn-m
Shear 49.51 kn

Calculate Reinforcement

Concrete - Grade C-25 Steel


Fck 20,000 kpa [ESEN 1992 Table 3.1] Fyk 360,000 kpa
Fctk 1,500 kpa [ESEN 1992 Table 3.1] PS 1.15 [ESEN 1992 Table 2.1N]
PS Factor 1.5 [ESEN 1992 Table 2.1N] Fyd 313,043 kpa
Fcd 11333.33 kpa Es 200,000 kpa
Fctd 1,000 kpa r (min) = 0.002
Ecm 29,000 kpa [ESEN 1992 Table 3.1] r (max) = 0.04

[ √ ]
2 mR n f Mu
1 m= yd
Rn =
ρreq = 1− 1− f cd bd 2
m f yd

Negative Reinforcement Posetive Reinforcement


m = 27.62 m = 27.62
Rn = -2745.0441 Rn = 1937.2227
r = -0.0079 r = 0.0068332
As = -0.00058 As = 0.00050
f = 16 f = 16
No = 2 No = 3
f = 16 f = 16
No = 0 No = 3
As prvd = 0.00040212 As prvd = 0.0012
Capacity = 42.45 Capacity = 106.38
Reserve = -158.04% Reserve = 106.10%

Shear Capacity of Concrete Design Shear Reinforcement


A v df yd
V c =0 . 25 f ctd k 1 k 2 b w d s=
Vs Vs = 20.76
k1 = 1.275
k2 = 1.235 Use Dia 8 Av = 0.0001005
s = 0.18 m Use 0.000
Vc = 28.75 KN Max S = 0.000 m S=180mm