You are on page 1of 2
Synergy” H1 Hybrid Multi-Mode Microplate Reader Synergy” H1 is one of BioTek’s 2 uL assays, its the perfect Gas Controller for Live Hybrid readers; equipped with instrument forlfe-science research Cell Assays both mono-chromator and filter laboratories. optical systems. Synergy H1 provides the same combination _ Patented Hybrid Optical System of flexibility and performance An available Gas Controller for Synergy H1 allows control and monitoring of CO, and O, Ang the optional fier Ievelin the syste The Gos asthe Synergy HA at avery oculeursthe Seay H1__Contal long wth vanced prective, bitce, An optiona into an advanced Hybrid reader. temperature control to 65 °C and reagent injection system is This patented optical design orbital shaking, create the ideal available. is only available from BioTek. physiological environment needed Monocvoratre provide case. forage sing ve cle Flxdbity ata Great Price Monoshomstrs provide synergy He avatale Bere provide increased optical Upgradable to Advanced ina menochromatcronly eficency and sens Reed Modes ‘configuration. Supporting top and bottom fluorescence, UV-visible absorbance and luminescence, itis the most cost-effective solution ofits type on the market. Combined with the Take3™ Micro Volume Plate for low volume When equipped with the optional filter module, Synergy H1 may be used for fluorescence polarization assays as well as Time-Resolved Fluorescence (TRF) and TR-FRET assays ‘ppical Applications: Nucleic acid quantification Protein quantification Enzyme kinetics Biomarker quantification ELISAs Yeast kinetic analysis Genetic analysis Drug discovery Synergy H1 shown with optional Cell proliferation Gas Controller module Cytotonicity Drug absorption and metabolism Biologics drug discovery and development Food safety vvrvvyvyyvyvyvy¥yyy Environmental monitoring 16 | BioTek Readers # Syne specifications General ee Monechvomator sytem: Fluorscene,Luminescencs, Detection mode Wable Absorbance rer set: Eluorescone, Time Resohed Fluorescence, Foredcance Plsraason, Lamnossonce ead method End pit, tne special searing, waltarea seaming Microplate ype 1-10 3040 late P95 Sepatia wth Take3 Mico-Volume Pte Temperature To ASC; 205°C at 37°C Shaking Yee Sofre Gen5 Data Analysis Software ‘Avtomaton Compatible with SloStack” and 3d party avtaton 0,and 0, _—_—Range: 0-208 (CO, 1 - 19% (0,) ‘rte Contol Resoiaon: 20% (CO, and) Stabiiy: #02% at 5% CO, =0.2% at 1% O, Modes fr both CO, and O, or CO, only are evalabe Absorbance Light source | Xenon flash lamp Wiovelensth ——- Monechromator tee Wavelength range 230-999 nm, 1 nm inerement Bandposs “4 (230-285 rm, @ nm (2285) Dynamicrange 0 4000 Resoition 0.0001 0D Patlength Yes ee [am tony” Monechromator +020 wavelength Tepeetsly OD accuracy 1% at 20 OD typical 8 330 OD Seal ODiinearty 1% from 019 30 OD typical OD repeatabiltly _<0.5% 82000 Hpi Stray ght (0.03% at 230 em ypc Reading speed $6 welts 11 seconde Speciation are bjt to change, Fluorescence Intensity Light source Xenon lash lamp Seasitv Monachnemsters 2 Top Raprsen 25 pM tye (025 faa 38k sel gn) Bonn: Fverescsn 5 pM typical (0 fol well ‘8sel plane). Flgceescein 1 pM types! (01 fnl/vell 384-well plate) Wavelength Double grating monochromator tonboton) sd, telecon Baap biacang Sanda froreldicraie mare (3) Werden moe | Moroes: 2070 oe cpt Dynamic range 5S ecdes Dnecon sytem Te ST dato ofr menos stem one Reading speed 96 wal 11 seconde ‘Sbe wale 22 Seconds Luminescence sensit Monochromatr sytem: 29 arol ATP typical fash Ey PiSSPSyteme 90 cro! Are pea as Wavelength range 300-700 0m Dyramic range [56 decades Fluorescence Polarization Senstty iP at 1 nM fuareacein spi Wavelength range | 320-700 nm (850 nen option) Time-Resolved Fluorescence Light source Kenon fish lame Senstvty ropiun 100 M tyes with iter (10 amoVweln 58¢cel late) Wavelength range | 200-700 nm (850 nm option Reagent Dispensers Number 2oyinge pune Dispense volume 51000 pin 1 pl increments Dead volume 1 ml, 10D pL wth back hush Pte geometry 6:1 384ml microplates Dispense preciion <2 ot 50-200 pL Diepense accuracy 21 pLor 2 Physical Characteristics Power 00-240 Vole AC S0/60 He Dimensions 154°W186°D 129°H 99.1 x47.2x326 em) Weight lbs (225 ko) Regulatory CE and TUV marked. n Viro Diagnose ure modle fe nalibe. wwrmbiotek.com 17

You might also like