Fuji Rep News (Appendix) No. 07135A


Machine type: NXT June 15, 2007

Subject: Procedures to correct a calibration error that occurred during


assembly of the close motor for VE type shuttle conveyors
(replaces Fuji Rep News No. 07127).

The following pages are the document “Machines Requiring Calibration”, which is a supplement to Fuji
Rep News 07135.

http://www.fuji.co.jp/ J Ref.: 07177A


Copyright © 2007 by Fuji Machine Manufacturing Co., Ltd. All Rights Reserved.
Fuji Rep News (Appendix) No. 07135A 2/4

1. Machines Requiring Calibration


Serial numbers for machines requiring calibration are listed below.

STC-5060A-F(Dependent Type)
X Serial number X Serial number
1 SC6SF000269 21 SC6SF000299
2 SC6SF000270 22 SC6SF000300
3 SC6SF000271 24 SC6SF000302
4 SC6SF000272 25 SC6SF000303
5 SC6SF000273 26 SC6SF000304
6 SC6SF000274 28 SC6SF000306
7 SC6SF000275 29 SC6SF000307
8 SC6SF000276 30 SC6SF000308
9 SC6SF000277 31 SC6SF000309
10 SC6SF000278 35 SC6SF000313
11 SC6SF000279 37 SC6SF000315
12 SC6SF000280 38 SC6SF000316
13 SC6SF000281 41 SC6SF000321
14 SC6SF000282 42 SC6SF000322
15 SC6SF000283 49 SC6SF000329
16 SC6SF000284 50 SC6SF000330
17 SC6SF000285 55 SC6SF000335
18 SC6SF000286 57 SC6SF000337
19 SC6SF000287 58 SC6SF000338
20 SC6SF000288 59 SC6SF000339

STC-5060B-F (Independent type)


X Serial number
4 SC6SD000290
5 SC6SD000291

http://www.fuji.co.jp/ J Ref.: 07177A


Copyright © 2007 by Fuji Machine Manufacturing Co., Ltd. All Rights Reserved.
Fuji Rep News (Appendix) No. 07135A 3/4

Location of S/N

Location of
serial number

The location of the S/N is the same for both the STC-5060A-F (Dependant type) and STC-5060B-F
(Independent type).

http://www.fuji.co.jp/ J Ref.: 07177A


Copyright © 2007 by Fuji Machine Manufacturing Co., Ltd. All Rights Reserved.
Fuji Rep News (Appendix) No. 07135A 4/4

2. Specifications for the Communication Cable

The communication cable used to connect the conveyor controller and computer must satisfy the
specifications listed below.

Interlink Serial Cross Cable

2 D-Sub9 (female) 2 D-Sub9 (female)

Wiring for the interlink serial cross cable

frame frame
shield

Wiring for the cross cable


Caution: Do not use a cable with wiring like the one shown to the right.
When using a commercially available cable that has wiring like the
one shown to the right (a short circuit exists between pins 7 and 8), frame frame
shield
the motor may run out of control.

Caution: Commercially available cross cables that are compatible with conveyor controller firmware earlier
than V1.36 may not be compatible with firmware V1.36 or later. To ensure the compatibility of cables,
ensure that the wiring is correct before use.