3. Do not connect, repair, or inspect the unit while connected to a power source. Model Time range Time unit Time setting range Model Time range Time unit Time setting range Output indicator (red)
Failure to follow this instruction may result in electric shock or fire. 1 0.1 to 1 sec 6 0.6 to 6 sec
4. Check 'Connections' before wiring. s s ※In case of ATE8-4 , ATE8-4 E, after operating instantaneous contact, time-limit contact operates within 30ms.
10 1 to 10 sec 60 6 to 60 sec
Failure to follow this instruction may result in fire.
5. Do not disassemble or modify the unit. ATE8-41 1 0.1 to 1 min ATE8-46 6 0.6 to 6 min
m m
Failure to follow this instruction may result in electric shock or fire. 10 1 to 10 min 60 6 to 60 min Cautions during Use
1 h 0.1 to 1 hour 6 h 0.6 to 6 hour
Caution 3 0.3 to 3 sec 12 s 1.2 to 12 sec
1. Follow instructions in 'Cautions during Use'. Otherwise, It may cause unexpected accidents.
s 2. When supplying or turning off the power, use a switch or etc. to avoid chattering.
1. Use the unit within the rated specifications. 30 3 to 30 sec 12 1.2 to 12 min 3. Install a power switch or circuit breaker in the easily accessible place for supplying or disconnecting the power.
Failure to follow this instruction may result in fire or product damage. m
ATE8-43 3 0.3 to 3 min ATE8-4C 24 2.4 to 24 min 4. In order to avoid leakage current flowing, connect resistance and condenser as (Figure 2).
2. Use dry cloth to clean the unit, and do not use water or organic solvent. m If connect as (Figure 1), it may cause malfunction due to leakage current.
Failure to follow this instruction may result in electric shock or fire. 30 3 to 30 min 12 1.2 to 12 hour
h
3. Do not use the unit in the place where flammable/explosive/corrosive gas, humidity, direct sunlight, 3 h 0.3 to 3 hour 24 2.4 to 24 hour (Figure 2)
(Figure 1)
radiant heat, vibration, impact, or salinity may be present.
Failure to follow this instruction may result in fire or explosion.
4. Keep metal chip, dust, and wire residue from flowing into the unit.
Dimensions (unit: mm) Connections Leakage current R
11.8 73.5
Power
Power
ATE8-4
Timer
Timer
Failure to follow this instruction may result in fire or product damage. T
48 59 T
4 5 R C C
Ordering Information 3 6
※Sockets (PG-08, PS-08 (N)) are sold separately. (Instantaneous 1a) (Time limit 1c)
ATE 8 4 3 D 2 7 5. Keep away from high voltage lines or power lines to prevent inductive noise.
No mark Time limit 1c+Instantaneous 1a
44.3
Control output 1 8 In case installing power line and input signal line closely, use line filter or varistor at power line and shielded
D Time limit 2c CONTACT: wire at input signal line.
E Time limit 1c+Instantaneous 1c 250VAC 3A Do not use near the equipment which generates strong magnetic force or high frequency noise.
SOURCE:
1 1 sec/10 sec/1 min/10 min/1 hour RESISTIVE 6. Connect output contacts of different pole to be electrokinetic potential.
100-240VAC 50/60Hz 3.5VA
LOAD 7. Change setting time(T1), Y-Δ switching time or etc. after turning off the power of the timer.
Time range 3 3 sec/30 sec/3 min/30 min/3 hour Panel cut-out 24-240VDC 1.5W
min.65 8. This unit may be used in the following environments.
6 6 sec/60 sec/6 min/60 min/6 hour ①Indoors (in the environment condition rated in 'Specifications')
ATE8-4 D
C 12 sec/12 min/24 min/12 hour/24 hour 4 5 ②Altitude max. 2,000m
45+0.6
Number of plug pins (Time limit 1c) (Time limit 1c) ④Installation category II
8 8-pin plug type 45+0.6
0
2 7
Item
ATE Analog timer
1 8
CONTACT:
Major Products
Photoelectric Sensors Temperature Controllers
250VAC 3A Fiber Optic Sensors Temperature/Humidity Transducers
Unit Description Bracket (sold separately(BK-S))
SOURCE:
100-240VAC 50/60Hz 3.5VA
RESISTIVE Door Sensors
Door Side Sensors
SSRs/Power Controllers
Counters
LOAD
24-240VDC 1.5W Area Sensors Timers
Time range selector Proximity Sensors Panel Meters
Output indicator (red) ATE8-4 E Pressure Sensors Tachometers/Pulse (Rate) Meters
4 5 Rotary Encoders Display Units
※1 3 6 Connectors/Sockets Sensor Controllers
Power indicator (white) 60.27 30.5 Switching Mode Power Supplies http://www.autonics.com
(Instantaneous 1c) (Time limit 1c)
2 7 Control Switches/Lamps/Buzzers HEADQUARTERS:
Time setting dial I/O Terminal Blocks & Cables
※1: As time progress indicator, 1 8 18, Bansong-ro 513beon-gil, Haeundae-gu, Busan,
Stepper Motors/Drivers/Motion Controllers South Korea, 48002
it flashes once for 1 sec CONTACT:
49.5