You are on page 1of 2

TECHNCIAL DATASHEET

DATE : 17.08.2022
CUSTOMER NAME : RUNGTA MINES LIMITED
PO NO : 4300016427 DT 03.08.2022
SIGNAL CABLE DATASHEET DT 17.08.2022

S.No. DISCRIPTION UNIT 2P x 1.0 sq.mm 5P x 1.0 sq.mm 4T x 1.0 sq.mm 8T x 1.0 sq.mm

1 NAME OF THE MANUFACTURER Tempsens Instruments (I) Pvt Ltd


2 PLACE & COUNTRY OF Udaipur, Rajasthan (INDIA)
3 CABLE TYPE Signal Cable

4 APPLICABLE STANDARDS BS 50288-7, IS 1554-1 , IS 8130 & this Datasheets

5 No. of Pairs/Triads Nos. 2 5 4 8


6 Voltage grade V 650/1100 V
7 CONDUCTOR
a) Material Electrolytic Grade Bare Copper
b) Grade Electrolytic
c) Size Sq.mm 1.0 Sqmm
d) No. of strands/Appx dia of each strand No./mm 32 / 0.20 mm (before stranding)
e) Shape of Conductor Circular

8 INSULATION
a) Material HR PVC Insulation (Type C As per IS 5831)
b) Type Extruded
c) Thickness (nom) mm 0.60 mm (Nom)
Pair/Triad Identification White & Blue with numbering White, Black & Brown with
d)
numbering
e) Appx number of twists of cores in a No. 10

9 INDIVIDUAL PAIR/TRIAD
SHIELDING
a) Material Aluminum mylar tape screening with ATC Drain wire
b) Type Helical
c) Thickness (min.) mm 28 Micron
d) Overlap % > 25 %
e) Coverage % 100%

10 DRAIN WIRE (For individuall


shielding)
a) Material Tinned Copper
b) Size Sq.mm 0.50 Sqmm
c) No. of strands/approx. dia of each No./mm 7 X 0.30 mm (Before stranding), Stranded dia 0.90 mm (Approx)
strand
Mylar tape after all shielded
Shall be provided
pair laid up
12 INNER SHEATH Yes
a) Materials HR FR PVC Sheath (Type ST2)
b) Type Extruded
c) Thickness (min) mm 0.30 mm (As per IS 1554-1)
d) Colour Black Black Black Black
13 Rip cord Shall be provided below inner sheath
14 Braiding for overall shielding
a) Material Tinned Copper
b) Size (nom) mm 0.20 0.20 0.20 0.20
c) Coverage % Min 80 %

14 OUTER SHEATH
a) Material HR FR PVC Sheath (Type ST2)
b) Type Extruded Extruded Extruded Extruded
c) Thickness (nom) mm 1.40 mm 1.40 mm 1.40 mm 1.60 mm
d) Colour of outer sheath Grey Color
e) Overall diameter(Approx) mm 15.0 18.0 20 25.0
f) Tolerance on overall diameter mm +/- 2.0 mm
g) Marking on outer sheath Mfr Name, No of Pair/Traid, Size, Year of Mfr
Drum Length
15 *(a) ( Packing shall be done in non- mtrs 1000 1000 1000 500
returnable wooden drum )
b) Tolerance of individual drum length & %
overall quantity
+ 5%-0%

16 ELECTRICAL PARAMETERS
a) Max.DC resistance of conductor of ohm/Km
19.50
completed cable at 20 Deg. C
b) Min Insulation resistance at 20 deg.C Mohm/K
100
m
c) Max. mutual capacitance of pairs at pF/mtr 250
d) Max. capacitance between any core to pF/mtr 400
e) High voltage test kV rms 2
f) L/R ratio [max] microH/
40
Ohm

17 Approx. weight of cable kg/Km 295.0 530.0 540.0 870.0

18 Min. Bending Radius of Cable shall be mm 12 XOD


specified
19 Short circuit rating of conductor for 1 kA 0.104 KA
sec. duration shall be
20 specified
Total Qty Mtr 3700 5000 3000 3000