UGANDA NATIONAL BUREAU OF STANDARDS ELECTRICAL LABORATORY TEST REPORT “Test Report No: €1/2022100073 ‘Sample No: /0088/2022T Fleld No: WA ‘of Client: CABLE CORPORATION LIMITED ‘Address: Plot No, 1, Namenge Ward, Central Division, Lua ‘Municipal ~ Buikwe District Monutacure/ Exporter: CABLE CORPORATION LIMITED Sample Quenly : 9 metres Sample Desrpon: 2.5 mn# muli-core ordinary poly choideshasthed axa. Lot Size: NA cable 60227 IEC 53 Siete of Sample(ey Bare ro Sarmling Report No: NA Date o Testing :2022.62-28 Leb Receipt Dat: 2022-02-28 Test Method) US 606; 1995 & US IEC 60227-52011 ‘Nar ‘Test Results it Parameters Results Specification Status 1 Marking requirements 1) Indication of Indication of origin is__Cables shall be provided with an indication of the Pass. origin provided by a repetitive manufacturer, which shall be either an identification thread ‘marking of manufacturer or a repetitive marking of the manufacturer's name or tracle- name mark. ii), Continuity of |The distance between Each specified mark shall be regarded as continuous Ifthe Pass marks the identical marks does distance between the end of the mark and the beginning of fiot exceed 550mm on” the next identical mark does not exceed 550 mm ifthe the outer sheath of the marking is on the outer sheath of the cable and 275 mm if cable the marking is on the insulation of an unsheathed cable; on the Ingulation of a sheathed cable; on a tape within a sheathed cable. ii), Durability The printed markings are. Printed markings shall be durable. Compliance with this Pass durable requirement shall be checked by the test given In 1.8 of IEC. 60227-2 Analysed By: Nicholas Kimanywenda Date: 2022-03-01 Mukwaya Bernard 2022-03-01 “Technical Signatory: This ost report i only valid if it boars a an authorised signature. The test report has been issue without any alterations and may not be reproduced except with written approval from the Excutive Director, Uganda National Bureau of Standards ‘weyopeer usta Pak, Pa 2-12 ypass Link, Kawa Road, P-O.BOX 6320, Kampala, Te: 0417393250, Page: 1 of 4 UGANDA NATIONAL BUREAU OF STANDARDS: ELECTRICAL LABORATORY TEST REPORT 4 Parameters Results Specification Status 1), Material of wires The wire is plain “The conductors shall consist of annealed copper. excepl for Pass annealed copper the wires of tinsel cords, for which a copper alloy may be conductor used. The wires may be plain or tinned. Wi), Class of “The conductor is of class The conductors shall comply with the requirements of IEC Pass conductor Siflexible conductors 60228 for class 5 figxible conductors ii), Sheath The sheath does not -_The sheath may fil he spaces between the cores, thus Pass. application adhere to the cores and forming a filing, but it shall not adhere to the cores. The does fillthe spaces. assembly of cores may be surrounded by a separator, between the cores which shall not adhere fo the cores, 5 Dimensional requirements 1), Number of wires 30 30 (Minimum) Pass 1), Overall 86 68-86 (Range) Pass diameter (mm) ii), Core 4 0.25 0.24 - 0.26 (Range) Pass: conductor diameter (mm) iv), Core 2 0.25 0.24 -0.26 (Range) Pass: conductor diameter (mm) vp. Core 1 09 0.7 (Minimum) Pass, insulation thickness (oom) vi). Core 2 09 0.7 (Minimum) Pass Insulation thickness (mm) ‘Altachmont(s) to the test report : NONE Remarks ‘Analysed By: Nicholas Kimanywenda Date: 2022-03-01 Mukwaya Berard 2022-03-01 “Technical Signatory i For Executive Director UNBS: ae Date: ‘Tho test roportis only valid It bears a an authorised signature, The test report has been issue without any alterations and may not be reproduced except with written approval from the Excutive Director, Uganda National Bureau of Standards. ‘eweyogear ndusbal Pork, Po 2-12, Bypass Link, Kyalwaala Road, P.0.8OX 6920, Kempe, Te: 0417935250 Page: 3 of 4 UGANDA NATIONAL BUREAU OF STANDARDS ELECTRICAL LABORATORY TEST REPORT 4. Tha above sample was analyzed as perth insrutions on UNBS Request for Analysis Form seral numer ‘RFA/202211653, 2. The Analysis was cortied out at UNBS Electrical Laboratory located at the adrass below using the tes! elnods Ihalcated above and the status of results as per the Uganda Standard US 605:1995, Standard Spocifeaion for aoorcuetor in culated cables and cords and US IEC 60227-:2011, Polyvinyl chloride Insulated cables of rated voltages up to and including 450/750 V - Part 6: Flexble cables (cords). 4. The sample tested above moos he requirements lested as specified nthe above Uganda Standards US 605:1095 and Us EC 60227-5:2011 {4 This tect report number EL/2022/00073 Is valid for sample number-/0088/2022T only and tne results apply 10 the sample as received, ‘Analysed By: Nicholas Kimanywenda Date: Mukwaya Bemard Date: 2022-03-01 2022-03-01 “Technical Signatory Tie test eportis only vat fitbeors a an authorised sknature, The lest report has been ise without any ateraions nd may not te produced axcopt wih wien approval rom the Exculve Dacia, Uganda National Bureau of Standards, weyoguere adult! Park, Po 2-12, Bypass Unk, Kalla Road .0.BOX 6920, Kampala, Te: 0417999260 Page: 4 of 4

You might also like