WaterTectonics worked with project partners to pilot an innova-
tive long-term cleanup approach for this closed mine operation QUICK FACTS Location: Montana, USA in Montana. The remote site produced year-round tailings that Client: Confidential discharged to a sensitive creek in pristine Montana wilderness. Year: 2012
WaterTectonics deployed a treatment train utilizing WaveIonics Industry: Mining
Application: Surface Water electrocoagulation followed by reverse osmosis and exceeded all Contaminants: TSS, TDS, Arsenic project effluent goals at an overall lower cost.
PARAMETER UNITS INFLUENT EC EFFLUENT RO EFFLUENT
Total Suspended Solids mg/L 32 11 0.1 Total Dissolved Solids mg/L 11,700 11,800 714 Sulfate mg/L 4,770 4,480 34 Iron, Total mg/L 266 0.22 0.01 Manganese, Total mg/L 11.4 0.768 0.005 Arsenic, Total mg/L 3.21 0.01 0.003