DG PED

Clean water
AUTOMATIC PRESSURISATION SYSTEM WITH INVERTER
Domestic use

Civil use

DESCRIPTION
ALL IN ONE
DG PED is an automatic pressurisation system with inverter whi-
˜
ch integrates: a high efficiency self-priming pump; an expansion Main components:
vessel; pressure and flow rate sensors; a non-return valve. Multistage self-priming pump
DG PED is a compact, autonomous, quiet and high perfor-
˜ Expansion vessel
mance pumping system. Non-return valve
Intuitive control panel
A sophisticated electronically controlled inverter, at the
˜
heart of the system, in an intuitive way: LOW-NOISE
– maintains the pressure of the installation constant by regulat-
ing the speed of the pump in accordance with the required flow
rate; CONSTANT PRESSURE
– controls the hydraulic and electric operating parameters and
protects the pump from anomalies;
– can be equipped with an expansion card that makes it possible EASY TO USE
to work in parallel with other inverters in the pumping groups
by managing input and output signals;
– it adapts to every type of pressurisation system, including existing INSTALLABLE
ones; ANYWHERE
– it limits the starting and operating currents in order to provide a
greater saving of energy.
Thanks to its compactness and
low noise level the DG PED can be
TECHNICAL DATA installed anywhere
• Supply voltage ~ 230 V ± 10% COMPACT
• Frequency 50/60 Hz
• Insulation: class F DIMENSIONS
• Max absorbed current: 7.5 A DG PED 3 - 10 A DG PED 5
• P1 Maximum absorbed power: 1.0 kW DG PED 3 - 1.5 kW DG PED 5 DOMESTIC USE
• Protection IP X4
• Factory set point 3 bar A single DG PED meets
the requirements of single
APPLICATION LIMITS apartments or small houses.
• Manometric suction lift up to 8 m
• Liquid temperature between 0 °C and +40 °C RESIDENTIAL USE
• Ambient temperature between 0 °C and +40 °C
• Max. working pressure 10 bar Two DG PED assembled as a set meet
• Continuous service S1 the requirements of more than one
• Operates in a vertical position apartment.

50
498Hz  |  DG PED 
CHARACTERISTIC CURVES
60 60

max 5.5 bar


DG PED 3 DG PED 5
max 5.5 bar
50 50

40 40

Set point 3 bar Set point 3 bar


30 30

H (m)
H (m)

20 20

min 1 bar min 1 bar


10 10

00 00 10 20 30 40 50 60 70 80 90 100 110 120 130


10 20 30 40 50 60 70 80 90
Q (l/min) Q (l/min)

MODEL POWER MAX PERFORMANCES PERFORMANCES (ADJUSTABLE SET POINT)


P2 Q H Min. Set Point Set Point Stand. Setting Max. Set Point
Single-phase kW HP  l/min metres bar l/min bar l/min bar l/min
DG PED 3 0.75 1 5 – 80 55 – 10 1 35 – 80 3 5 – 58 5.5 5 – 30
IE3
DG PED 5 1.1 1.5 5 – 120 55 – 10 1 50 – 120 3 5 – 92 5.5 5 – 50
Q = Flow rate H = Total manometric head Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.  Three-phase motor efficiency class (IEC 60034-30-1)

CHARACTERISTIC CURVES FOR GROUPS OF TWO DG PED 3 OR 5


60

max 5.5 bar


50

40

Set point 3 bar


H (m)

30 DG
PE DG DG
D3 PE PE
D3 D5
20 + +D +D
DG GP GP OPTIONAL ACCESSORIES
PE ED ED
min 1 bar D3 5 5
10

0
0 20 40 60 80 100 120 140 160 180 200 220 240 260
Q (l/min)

Connection kit for two DG PED units


23 137 78 228 84
G 1”

Electronic expansion circuit board


G 1”

360°
360°
344
278

184

Kit for wall-mounting a single


DG PED
200
160 66 180 144
274 390

Kit for wall-mounting a group of


two units

DG PED  |  50499
Hz