Professional Documents
Culture Documents
Watermarked LR22350646TA MergedAppendix
Watermarked LR22350646TA MergedAppendix
This is to certify that the undernoted product(s) has/have been tested with satisfactory results in accordance with
the relevant requirements of the Lloyd's Register Type Approval System.
Manufacturer Taixing Haixing Marine Machinery Co.,Ltd
Address Pioneering Park for, Economical and Trade, Industry Zone, Taixing Town,
Taixing, 225401, China
Place of Production Taixing Haixing Marine Machinery Co.,Ltd
Pioneering Park for, Economical and Trade, Industry Zone, Taixing Town,
Taixing, 225401, China
Application Automatic closing appliances for air and overflow pipes which terminate above
the open deck for use in marine industry.
2021), Part 3, Chapter 12, Section 3 and Part 5, Chapter 13, Section 12
IACS UR P3 “Air Pipe Closing Devices” (Rev. 4 January 2016)
Ru Zhang Shi
12th Floor, Chong Hing Finance Centre, No. 288 Lead Specialist and Section Leader for
Nanjing West Road, Shanghai, Huangpu District, Engineering Section to Lloyd's Register
200003, China Classification Society (China) Co Ltd
Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively,
referred to in this clause as 'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or
expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the
relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms
and conditions set out in that contract.
TA01 1.0.0
Page 2 of 2
Certificate No: LR22350646TA
Issue Date: 04/08/2022
Expiry Date: 03/08/2027
Other Conditions Where the air pipe head is intended to be installed on a ship classed or
intended to be classed with LR, the following conditions are applicable: -
1) The air pipe head is not to be used for venting of cargo oil tanks storing
flammable liquids having a flash point not exceeding 60°C (closed cup test).
2) Its position is to be indicated on the airpipe arrangement plan which is
submitted for approval.
3) The installation and maintenance are to bein accordance with the
manufacturer’s instructions.
4) Flow characteristic curves are to be available to the users.
5) To prevent blocking of the air pipe head openings by their own ball floats
during tank discharges, the user is to consult the manufacturer in determining
the size and number of the air pipe heads for individual applications.
6) Air pipe heads should not be fitted with a shut-off device, and acceptance
of use of the headHJQE450-DN450 having a shut-off device is to be separately
considered upon proposal for individual applications.
This certificate is not valid for equipment, the design, ratings or operating parameters of which have been varied
from the specimen tested. The manufacturer should notify Lloyd's Register Classification Society (China) Co Ltd of
any modification or changes to the equipment in order to obtain a valid Certificate.
Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively,
referred to in this clause as 'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or
expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the
relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms
and conditions set out in that contract.
TA01 1.0.0
Page 1 of 1
Certificate No: LR22350646TA
Issue Date: 04/08/2022
Expiry Date: 03/08/2027
Appendix
HJQE
Nominal Pipe Diameters (mm): DN50 - 600
DN50: 32.75
DN65: 17.89
DN80: 17.58
DN100: 13.83
DN125: 11.59
DN150: 23.69
DN200: 14.81
DN250: 14.52
DN300: 27.04
7.04
DN350:
50: 25.82
DN400: 23.13
DN450: 21.61
DN500: 14.77
DN600: 15.82
Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred
to in this clause as ‘Lloyd's Register’. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense
caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant
Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and
conditions set out in that contract.