InstalationManual IM-LAG1900-363-211-603
InstalationManual IM-LAG1900-363-211-603
363-211-603
CC109576140
Issue 1
July 2005
Lucent Technologies - Proprietary
This document contains proprietary information of Lucent Technologies and
is not to be disclosed or used except in accordance with applicable agreements.
Copyright © 2005 Lucent Technologies
Unpublished and Not for Publication
All Rights Reserved
See notice on first age
This material is protected by the copyright and trade secret laws of the United States and other countries. It may not be reproduced, distributed,
or altered in any fashion by any entity (either internal or external to Lucent Technologies), except in accordance with applicable agreements,
contracts or licensing, without the express written consent of Lucent Technologies and the business management owner of the material.
Trademarks
All trademarks and service marks specified herein are owned by their respective companies.
Notice
Every effort has been made to ensure that the information in this document was complete and accurate at the time of printing. However,
information is subject to change.
Safety
Always observe the Safety Instructions given in Chapter 1 when operating the system.
Ordering information
Technical support
Please contact your Lucent Technologies Local Customer Support Team (LCS) for technical questions about the information in this document.
To comment on this information product online, go to http://www.lucent-info.com/comments or email your comments to comments@lucent.com.
Purpose
BOOKMARK2::Purpose xxvii
Safety information
BOOKMARK4::Safety information xxvii
Intended audience
BOOKMARK5::Intended audience xxvii
Conventions used
BOOKMARK7::Conventions used xxviii
Related documentation
BOOKMARK8::Related documentation xxix
Technical support
BOOKMARK9::Technical support xxx
How to order
BOOKMARK10::How to order xxxi
How to comment
BOOKMARK11::How to comment xxxi
.....................................................................................................................................................................................................................................
1 Safety
BOOKMARK12::1 Safety
Overview
BOOKMARK13::Overview 1-1
DC power connections
BOOKMARK19::DC power connections 1-14
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary C O N T E N T S
Issue 1, July 2005 See notice on first page i i i
Laser safety guidelines
BOOKMARK20::Laser safety guidelines 1-15
2 General information
BOOKMARK25::2 General information
Overview
BOOKMARK26::Overview 2-1
ETSI V5 Shelf
BOOKMARK28::ETSI V5 Shelf 2-8
Technical data
BOOKMARK31::Technical data 2-12
3 Mechanical installation
BOOKMARK33::3 Mechanical installation
Overview
BOOKMARK34::Overview 3-1
Overview
BOOKMARK36::Overview 3-2
Wall mounting
BOOKMARK40::Wall mounting 3-11
Ceiling mounting
BOOKMARK41::Ceiling mounting 3-14
Grounding
BOOKMARK45::Grounding 3-27
....................................................................................................................................................................................................................................
C O N T E N T S Lucent Technologies - Proprietary 363-211-603
i v See notice on first page Issue 1, July 2005
Shelf installation
BOOKMARK46::Shelf installation
internal cables
Overview
BOOKMARK51::Overview 4-1
J1C293B-1
Overview
BOOKMARK53::Overview 4-3
Power connections
BOOKMARK54::Power connections 4-5
Ringing connections
BOOKMARK55::Ringing connections 4-7
Overview
BOOKMARK59::Overview 4-14
Ringing connections
BOOKMARK61::Ringing connections 4-18
Overview
BOOKMARK65::Overview 4-27
E1 connectors (D1/E1/F1/G1)
BOOKMARK67::E1 connectors (D1/E1/F1/G1) 4-32
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary C O N T E N T S
Issue 1, July 2005 See notice on first page v
Alarm connectors (F2/J3)
BOOKMARK71::Alarm connectors (F2/J3) 4-47
Overview
BOOKMARK75::Overview 4-53
E1 connectors (J101/J102)
BOOKMARK77::E1 connectors (J101/J102) 4-58
Overview
BOOKMARK86::Overview 4-79
CIU pack
BOOKMARK87::CIU pack 4-80
AFME1 pack
BOOKMARK89::AFME1 pack 4-88
AFMO pack
BOOKMARK90::AFMO pack 4-94
....................................................................................................................................................................................................................................
C O N T E N T S Lucent Technologies - Proprietary 363-211-603
v i See notice on first page Issue 1, July 2005
Internal cabling
BOOKMARK97::Internal cabling
Overview
BOOKMARK98::Overview 4-130
5 Cabling procedures
BOOKMARK101::5 Cabling procedures
Overview
BOOKMARK102::Overview 5-1
External Cables
BOOKMARK103::External Cables 5-4
daisy-chaining 5-12
daisy-chaining 5-19
Installing a/b-cables
BOOKMARK113::Installing a/b-cables 5-42
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary C O N T E N T S
Issue 1, July 2005 See notice on first page v i i
Fiber testing procedure
BOOKMARK122::Fiber testing procedure 5-80
Overview 5-109
subsystem. 5-113
6 Maintenance
BOOKMARK138::6 Maintenance
Overview
BOOKMARK139::Overview 6-1
.....................................................................................................................................................................................................................................
A Supplemental Information
BOOKMARK140::A Supplemental Information A-1
Overview
BOOKMARK141::Overview A-1
Connector types
BOOKMARK144::Connector types A-9
Overview
BOOKMARK146::Overview A-13
....................................................................................................................................................................................................................................
C O N T E N T S Lucent Technologies - Proprietary 363-211-603
v i i i See notice on first page Issue 1, July 2005
Cross-connection between AP connector - EC connectors
BOOKMARK147::Cross-connection between AP connector - EC connectors A-15
OAM&P connections
BOOKMARK154::OAM&P connections
Overview
BOOKMARK155::Overview A-34
GL Glossary
BOOKMARK162::Glossary GL-1
.....................................................................................................................................................................................................................................
IN Index
BOOKMARK163::Index IN-1
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary C O N T E N T S
Issue 1, July 2005 See notice on first page i x
List of tables
2 General information
5 Cabling procedures
5-11 CIU jumper setting for 120 Ω and 75 Ω clock cables 5-88
5-22 Interconnecting the test application paths via the MDF 5-105
A Supplemental Information
A-2 Color coding for the 1x32 pair a/b cables A-4
A-3 Color coding for the P1 connector 2×32 pair a/b cable Tip/Ring
1-32 A-6
A-4 Color coding for the P2 connector 2×32 pair a/b cable Tip/Ring
33-64 A-7
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary T A B L E S
Issue 1, July 2005 See notice on first page x v
List of figures
2 General information
3 Mechanical installation
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary F I G U R E S
Issue 1, July 2005 See notice on first page x v i i
3-14 Optical cable duct 3-25
4-15 External timing reference distribution for duplex office clock 4-21
4-30 120 Ω configuration (default - view on the printed circuit board) 4-39
4-42 Cable routing of the LAG 1900 Shelf connector field 4-55
5 Cabling procedures
5-26 Cabling principle for simplex AFM mode with daisy-chaining 5-65
5-27 Cabling principle for duplex AFM mode without daisy-chaining 5-70
5-29 Cabling principle for duplex AFM mode with daisy-chaining 5-75
5-38 Cabling for integrated testing with TAP10x via the MDF
(example ) 5-102
5-39 Direct cabling for integrated testing with TAP10x (example) 5-107
5-40 Cabling for remote testing (example for the ETSI V5 Shelf) 5-112
5-46 Ringing connection points on RFCP (rack type J1C293B-1 L3) 5-130
A Supplemental Information
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary F I G U R E S
Issue 1, July 2005 See notice on first page x x v
About this information product
...............................................................................................................................................................................................................................................................
Reason for reissue This is the first issue of this information product.
Safety information This information product contains hazard statements for your safety.
Hazard statements are given at points where safety consequences to
personnel, equipment, and operation may exist. Failure to follow these
statements may result in serious consequences.
Intended audience This manual is intended for users who wish to install, configure and
cable a DC powered rack and shelves including all accessories.
Working on the complex equipment and systems described in this
manual requires special training of the personnel.
How to use this This manual is divided into the following sections with a brief
information product description of the contents of each major part/chapter/appendix:
About this information product describes the purpose, intended
audience, reason for reissue, and organization of this document. This
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary xxvii
Issue 1, July 2005 See notice on first page
,
About this information product
Conventions used The following conventions are used throughout the manual:
....................................................................................................................................................................................................................................
xxviii Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
,
About this information product
Numbering
The chapters of this document are numbered consecutively. The page
numbering restarts at “1” in each chapter. To facilitate identifying
pages in different chapters, the page numbers are prefixed with the
chapter number. For example, page 2-3 is the third page in chapter 2.
Cross-references
Cross-reference conventions are identical with those used for
numbering, i.e. the first number in a reference to a particular page
refers to the corresponding chapter.
Keyword blocks
This document contains so-called keyword blocks to facilitate the
location of specific text passages. The keyword blocks are placed to
the left of the main text and indicate the contents of a paragraph or
group of paragraphs.
Abbreviations
Abbreviations used in this document can be found in the “Glossary”
unless it can be assumed that the reader is familiar with the
abbreviation.
Related documentation The following table lists the documents included in the AnyMedia ®
Access documentation set.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary xxix
Issue 1, July 2005 See notice on first page
,
About this information product
....................................................................................................................................................................................................................................
xxx Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
,
About this information product
How to order This information product can be ordered with the order number
363-211-603 at the Customer Information Center (CIC), see
http://www.cic.lucent.com/.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary xxxi
Issue 1, July 2005 See notice on first page
,
1 Safety
Overview
....................................................................................................................................................................................................................................
Contents
Structure of hazard statements 1-2
General safety information 1-4
Appearance of the safety instructions 1-8
Electrostatic discharge considerations 1-10
Necessary conditions for an EMC-compliant 1-13
installation
DC power connections 1-14
Laser safety guidelines 1-15
General installation warnings 1-24
General wiring warnings 1-27
Warnings for taking the power supply into operation 1-32
Warnings for transport and storage 1-36
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 1-1
Issue 1, July 2005 See notice on first page
Safety
Overview Hazard statements describe the safety risks relevant while performing
tasks on Lucent Technologies products during deployment and/or use.
Failure to avoid the hazards may have serious consequences.
Signal words The signal words identify the hazard severity levels as follows:
....................................................................................................................................................................................................................................
1-2 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Structure of hazard statements Safety
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 1-3
Issue 1, July 2005 See notice on first page
Safety
Overview This section lists the safety information needed to install and cable the
AnyMedia ® Access System.
Make sure that you read this section carefully and that you understand
all the safety information in this section. The safety information in
this section includes:
• Important general safety instructions
• Appearance and classification of safety instructions
• Understanding electrostatic discharge (ESD) and avoiding
damage from ESD
• Necessary conditions for an electromagnetic-compliant
installation (EMC, electromagnetic compatibility)
• DC power connections
• Lightwave safety
• Important installation and wiring safety instructions
• Important general safety instructions for taking the power supply
into operation
• Important general safety instructions for transporting and storage.
The chapter must be read and understood by the responsible trained
personnel/operator before mounting/commissioning, operation and
maintenance/repair. The valid version of this document must always
be kept close to the equipment/unit.
NOTE: If you do not understand any of the safety information in this
section, please see your manager immediately. You should also talk
with your manager if you feel you do not understand any procedures
in this manual, or if you feel you need additional training before
performing any of these procedures.
Not only the general instructions in this chapter on safety must be
observed, but also the specific safety instructions in the individual
chapters.
Only trained service personnel should perform the procedures in this
document. These procedures allow exposure to high electrical energy
and/or current that may result in electric shock and/or injury to
untrained personnel during servicing, maintenance, and installation of
this system.
All safety instructions have a uniform appearance. This appearance is
described in detail in “Appearance of the safety instructions” (1-8).
NOTE: The AnyMedia ® Access System must be supplied with Safety
Extra-Low Voltage (SELV) of –48 V and the positive terminal of this
....................................................................................................................................................................................................................................
1-4 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
General safety information Safety
General notes on safety This system has been developed in line with the present
state-of-the-art and fulfils the current national and international safety
requirements. It is provided with a high degree of operational safety
resulting from many years of development experience and continuous
stringent quality checks in our company.
The system is safe in normal operation. There are, however, some
potential sources of danger that cannot be completely eliminated. In
particular, these arise during
• opening of housings or equipment covers
• manipulation of any kind within the equipment, even if it has
been disconnected from the power supply
• possible contact with
– live parts
– laser light
– hot surfaces
– sharp edges, or
– devices sensitive to electrostatic discharge.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 1-5
Issue 1, July 2005 See notice on first page
General safety information Safety
....................................................................................................................................................................................................................................
1-6 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
General safety information Safety
• Never push objects of any kind into this product through slots as
they may touch dangerous voltage points or short out parts that
could result in a risk of fire or electrical shock. Never spill liquid
of any kind on the product.
• The AnyMedia ® Access System is fed by more than one power
feeder (multiple power feeding) from the external power source.
Switching off one of the power feeders will not necessarily
remove the power to the equipment. For deenergizing power
completely the circuit breaker to the DC power distribution
network must be switched off.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 1-7
Issue 1, July 2005 See notice on first page
Safety
CAUTION
Destruction of components due to a supply voltage
of incorrect polarity or a supply voltage which is too
high
The AnyMedia ® Access System operates at a nominal voltage of
−48 V DC. The permissible tolerance range is −40.5 V to −57 V
DC.
Ensure that the supply voltage has the correct range and polarity
before connecting the voltage (about –54 V for battery backed
DC distribution network). Ensure that fuses and circuit breakers
will be replaced with the same type and rating of fuse if required.
Never connect the AnyMedia ® Access System to −60 V DC.
....................................................................................................................................................................................................................................
1-8 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Appearance of the safety instructions Safety
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 1-9
Issue 1, July 2005 See notice on first page
Safety
General notes on ESD Electrostatic discharge (ESD), for example caused by touching with
the hand, can destroy semiconductor components. The correct
operation of the complete system is then no longer assured.
All semiconductor components are basically sensitive to electrostatic
discharge (ESD). The electrostatic discharge can also affect the
components indirectly via contacts or conductor tracks.
Circuit packs containing components that are especially sensitive to
electrostatic discharge are identified by warning labels bearing the
barred-hand symbol.
Warning symbol:
CAUTION
ESD hazard
Warning about devices sensitive to electrostatic discharge (ESD).
Electronic components can be destroyed by electrostatic discharge.
To avoid electrostatic discharge conductively connected wrist
straps connect to the rack ESD bonding point should be used.
Each rack has an ESD earth socket and an ESD sticker on the side
rails on both sides of the rack. It is mounted so that it is always
accessible for installation, normal operation and maintenance activity.
An ESD bonding point for an ESD wrist strap is also provided in the
connector field of the shelves.
CAUTION
ESD hazard
Electronic components can be destroyed by electrostatic discharge.
An electrostatic discharge wrist strap, with a resistance between
250 kΩ and 1.5 MΩ, should be worn when handling AnyMedia ®
Access System circuit packs to prevent possible damage to the
circuit packs. Before using the wrist strap, check the wrist strap
for shorts, opens, and proper resistance value. Do not use a wrist
strap that does not pass these checks.
....................................................................................................................................................................................................................................
1-10 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Electrostatic discharge considerations Safety
ESD wrist strap To reduce the possibility of ESD damage, the shelves and the racks
are equipped with a grounding jack to enable personnel to ground
themselves using wrist straps with a minimum resistance of 250 kΩ
while handling circuit packs or working on a shelf/shelves. The jacks
are located on the left and right of the rack and are accessible from
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 1-11
Issue 1, July 2005 See notice on first page
Electrostatic discharge considerations Safety
the front. When grounding jacks are not provided, an alligator clip
adapter enables connection to rack’s frame ground (FRMGND).
To
Ground
Connection
e12:/7W-21610.dia/fig_20.cdr
....................................................................................................................................................................................................................................
1-12 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Safety
Working environment All the equipment of the AnyMedia ® Access System is designed only
to work in meshed bonding network (mesh-BN) or meshed isolated
bonding network (mesh-IBN) environments which comply with
ETS 300 253. The conditions include the following:
• the framework (FRMGND) of the shelves and the rack are
connected to each other and have to be connected to the
protective earth (PE) and to the bonding wire,
• FRMGND and the –48 V return path (–48VRTN) have to be
connected together for mesh-BN environment,
• in mesh-BN environment the return path (tip wire, TRG) of the
ringing voltage has to be connected to the protective earth at the
ringing source side.
The framework must be correctly connected to the protective earth
before the start of work.
The CE-marked racks/shelves need the EMC-proof connecting
material, such as shielded cables and metallic or conductive D-sub
connector hoods, to meet the CE Directives.
The housing of all connectors will be connected with frame ground
(FRMGND). Every shielding is connected to FRMGND.
Cables All cables except the a/b-cables of the application packs (AP), the
power cables and the ringing cables must be shielded and must be
equipped with EMC-tight connectors.
All E1-cables and the cables for station clock cabling must be
shielded. The E1 cables must have an impedance of 120 Ohms
(twisted pair). The station clock may also use 75 Ohms (coaxial)
cable.
All E3/DS3 coaxial cables must have an impedance of 75 Ohms. Only
cables with right-angled connectors should be connected to the AFM
pack, otherwise the doors of the rack cannot be closed.
For connecting a PC-GSI via the CONSOLE connector (RS-232C) to
the AFM pack for ATM xDSL applications, a 9-pin D-sub connector
with angled housing should be connected, otherwise the doors of the
shelves cannot be closed.
All a/b-cables, E1-, E3/DS3, xDSL-cables and the alarming cabling
should not leave the building premises unless connected to
telecommunication devices providing primary protection (for example
protector blocks with gas discharge tubes) as applicable.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 1-13
Issue 1, July 2005 See notice on first page
Safety
DC power connections
....................................................................................................................................................................................................................................
DC power requirements The equipment must be supplied with Safety Extra-Low Voltage
(SELV) of –48 V and the positive terminal of this source must be
correctly earthed according to EN 300 253. For mesh-BN
configurations, –48VRTN is also connected to frame ground in the
rack.
Ringing The ringing return path (tip wire, TRG) of the customer’s ringing
generator must be connected externally to the protective earth (and is
therefore connected to the –48 V return path (–48VRTN) of the
customer’s external –48 V (battery backed ringing only).
For mesh-BN configurations, both the –48 V return path (–48VRTN)
and the return path (TRG) of the ringing generator are internally
connected to the metalwork of the rack (potential FRMGND). These
connections via cables/studs are not visible. For mesh-IBN
configurations, the return path (TRG) is connected to ground at the
source but not at the rack.
WARNING
Electric shock hazard
The AnyMedia ® Access System can be fed by ringing voltages of
57 V DC maximum superimposed by 105 V AC maximum. Touching
live ringing cables will shock or cause serious injury or death. This
applies to the cabling from the external ringing source up to the
shelves.
Take care when servicing in this area. Follow all safety warnings
and local regulation practices.
....................................................................................................................................................................................................................................
1-14 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Safety
General laser information The AnyMedia ® Access System is equipped with a laser source on the
optical application pack (OAP), the optical controller pack in the
Subshelves (OCP) and on the optical AFM (AFMO). Fibers are routed
to these packs.
Lightwave digital transmission system and associated optical test sets
use semiconductor laser transmitters. The lasers emit lightwaves into
lightguide cables, at or near infrared wavelengths that are invisible to
the human eye (wavelengths between 800 nm and 1600 nm).
Light energy emitted by laser and high-radiance LEDs may cause eye
damage if absorbed by the eye’s retina. When a beam of light enters
the eye, the eye magnifies and focuses the energy increasing the
damage and may cause a retinal burn. The damage mechanism at the
wavelengths used in telecommunications is thermal in origin, that is,
damage caused by heating. Therefore, a specific amount of energy is
required for a definite time to heat an area of retinal tissue.
A conventional laser produces a small beam of light, and because the
beam is small the power density is very high. Lasers used in
lightwave systems have a larger beam divergence, typically 10 to 20
degrees. Inadvertently viewing an unterminated fiber or damaged fiber
with the unaided eye at distances greater than 150 mm (6 inches) will
normally not cause eye injury. However, damage may occur if an
optical instrument such as a microscope, magnifying glass or eye
loupe is used to view the energized fiber end.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 1-15
Issue 1, July 2005 See notice on first page
Laser safety guidelines Safety
CAUTION
Laser hazard
Lightwave digital transmission systems and associated optical test sets
operate with invisible laser radiation. Laser radiation can cause
damage to the skin and considerable injuries to the eyes.This applies
particularly to the connections of the optical packs. Although, at
present, the transmitting power levels for Class 1 lasers are below
those known to cause injury to the eye at distances greater than
250 mm (≈ 10 inches) direct exposure should always be avoided.
Don’t look into the end of an exposed fiber or optical connector
of a pack as long as the optical source is switched on. Never
view any unterminated optical connector with optical microscope
or magnifying glasses as long as the laser source is switched on.
Always test with an optical power meter or infrared detectors
that the fiber is deenergized and ensure that the laser source can
not be activated during inspection with the microscope.
Never view any unterminated optical connector with optical
instruments other than special indirect image-converting devices
such as the FIND-R-SCOPE of FJW Optical Systems, Inc., since
viewing optics tend to collimate the energy from an optical
connector and, hence, increase the potential risk of injury.
Always observe the laser warning instructions in “Laser safety”
(1-17).
....................................................................................................................................................................................................................................
1-16 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Laser safety guidelines Safety
WARNING
Laser hazard
The optical packs do not have an Automatic Laser Shutdown (ALS)
feature compliant with ITU-T G.958 and IEC 60825. The internal
laser source is on as soon as the optical packs are powered. This
must be considered especially before checking the fiber with an
optical microscope.
Never view any unterminated optical connector with optical
microscope or magnifying glasses as long as the laser source is
switched on. Always test with an optical power meter or infrared
detectors that the fiber is deenergized and ensure that the laser
source can not be activated during inspection with the
microscope.
Laser safety
CAUTION
Laser hazard
Although, at present, the transmitting power levels for Laser Class 1
are below those known to cause injury to the eye at distances greater
than 250 mm (≈ 10 inches) direct exposure should always be
avoided.
Always observe the laser warning instructions (see instructions
below).
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 1-17
Issue 1, July 2005 See notice on first page
Laser safety guidelines Safety
Classification of lasers The laser classes are defined in standards such as EC 60825 (or
EN 60825) and its supplements. A maximum laser radiation is defined
for each laser class according to the wavelength. The maximum laser
radiation depends on the type of laser diode used. This results in
different laser classes for the various optical circuit packs.
These standards require manufacturers to classify their laser products
as belonging to one of the major classes, classes 1, 2, 3A, and 3B.
Manufacturers of lasers and laser products in the U.S. are regulated by
the Food and Drug Administration’s Center for Devices and
Radiological Health FDA/CDRH) under 21 CFR 1040. Classification
....................................................................................................................................................................................................................................
1-18 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Laser safety guidelines Safety
schemes are similar to the IEC with categories such as class I, II, lla,
IlIa or lllb. In both cases, laser products are classified according to the
accessible emission levels and their potential for causing injury.
Laser classes to IEC 60825 and DIN/EN 60825.
LASER PRODUCT
CLASS 1
CLASS 1
LASER PRODUCT
Appropriate labels are also available for the remaining laser classes
(k x 3A, 3B); each label indicates the laser class, wavelength and
maximum laser radiation. These labels are affixed in a clearly visible
position on the equipment.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 1-19
Issue 1, July 2005 See notice on first page
Laser safety guidelines Safety
Handling fibers Never look into the end of an exposed fiber or optical connector of a
pack as long as the optical source is switched on. Always observe the
laser warning instructions.
Splicing Cutting and splicing fibers must be followed and performed by trained
personnel only. Read and understand all instructions of the manual of
the splicing and cutting equipment.
Before splicing verify the fiber is disconnected from the optical pack
or the laser source.
To protect the fiber connectors and couplers from contamination when
not in use, make sure that their protective covers/cups are in place.
WARNING
Injury to eyes caused by broken-off fiber ends
When splicing optical fibers, fiber ends can easily break off and get in
your eyes. This can cause eye damage.
Make sure that no broken-off fiber ends get in your eyes. If
required use safety goggles for fiber splicing. Place broken-off
fiber ends in a sealed container immediately after you cut them
off.
....................................................................................................................................................................................................................................
1-20 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Laser safety guidelines Safety
Routing and connecting During installation of fibers the optical connectors of fibers and the
connectors on the optical packs must be equipped with a protective
cap until the connectors are coupled.
The fibers should be guided to the optical packs using the special
protective spiral wrap of the pigtail.
For connecting fibers to optical packs/modules with the ALS feature
connect the outgoing fiber at first and then the incoming fiber.
If the fiber is routed from bottom to an optical connector take care if
the fiber has to be disconnected so that the fiber will not hang out of
the shelf and can be bent or broken.
Optical cable break There is a risk to cause microdefects in the fiber or a risk of a cable
break if the bending radius of optical fiber cables is less than about
30 mm. Microdefects can increase the fiber attenuation and reduce
the long term stability. Ensure that the bending radius is not less than
30 mm.
Always use the special protective spiral wrap delivered with the fiber
pigtails to the optical packs. For the office fiber cable the allowed
bending radius depending on the cable used must be obeyed.
Checking fiber connectors Before starting to clean the optical connectors, ensure that the optical
source is switched off. Never look into the end of an exposed fiber or
optical connector of a pack as long as the optical source is switched
on. Always observe the laser warning instructions.
To check for impurities (for example fluff, dust particles, ...), use a
microscope with an enlargement factor of 40, so that the connector
face can be inspected.
Cleaning SC-type On the SC-type connectors the ferrule has to be cleaned with optical
connectors lint-free tissues or with a wipe moistened with isopropyl alcohol and
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 1-21
Issue 1, July 2005 See notice on first page
Laser safety guidelines Safety
blow-dry with canned compressed air. The end and the sides of the
ferrule should be cleaned.
Cleaning LBOs The Base of the LBO can be cleaned by placing a pipe cleaner inside
the Base and gently rotating. If the pipe cleaner is moistened with
isopropyl alcohol the Base must blow-dry with canned compressed air.
The Cap of the LBO can only be cleaned by holding canned
compressed air nozzle about 7 cm (3 inches) from the Cap ends.
Never use a pipe cleaner to clean the Cap.
Checking optical couplers Visually check the coupling for residual impurities by holding it to the
light (the geometry of the coupling does not allow the coupling to be
checked under the microscope). After cleaning with a pipe cleaner do
not connect the optical connectors/couplings without checking them
for impurities.
Handling the optical packs The optical packs do not have an Automatic Laser Shutdown (ALS)
feature compliant with ITU-T G.958 and IEC 60825. The internal
laser source is on as soon as the optical packs are powered. This must
be considered especially before checking the fiber with an optical
microscope.
WARNING
Laser hazard
The optical packs do not have an Automatic Laser Shutdown (ALS)
feature compliant with ITU-T G.958 and IEC 60825. The internal
laser source is on as soon as the optical packs are powered. This
must be considered especially before checking the fiber with an
optical microscope.
Never view any unterminated optical connector with optical
microscope or magnifying glasses as long as the laser source is
switched on. Always test with an optical power meter or infrared
detectors that the fiber is deenergized and ensure that the laser
source can not be activated during inspection with the
microscope.
....................................................................................................................................................................................................................................
1-22 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Laser safety guidelines Safety
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 1-23
Issue 1, July 2005 See notice on first page
Safety
WARNING
Risk of injury due to untrained personnel
Installation and maintenance procedures must be followed and
performed by trained personnel only.
Do not allow non-service personnel to access electrical wiring.
Read and understand all instructions and warning labels. Follow
all warnings and instructions marked on the product and in the
manuals.
WARNING
Risk of injury due to unsecured rack
An unpacked rack, including doors, without shelves weighs up to 50
kg and can cause considerable injuries if it is knocked over or
dropped. This can also cause serious damage to the rack and the
shelves.
Use a sturdy vehicle for transport and secure the rack against
dropping. At least two persons are required for lifting the rack.
WARNING
Risk of injury due to unsecured shelf.
A fully-equipped LAG 1900 shelf weighs 43,6 kg (incl. shelf + fan +
cables) and a fully equipped ETSI V5 shelf weights 48kg (incl shelf +
fan + cables) and can cause considerable injuries if it is knocked over
or dropped. This can also cause serious damage to the shelf.
At least two persons are required for lifting the shelf.
....................................................................................................................................................................................................................................
1-24 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
General installation warnings Safety
WARNING
Ineffectiveness of laser warning labels if removed or
concealed
Warning labels on the optical components warn of the dangers of
invisible laser radiation. Removed, concealed or illegible labels can
lead to incorrect action and thus cause serious injuries to the eyes of
operating staff.
Ensure that the laser warning labels are not removed or
concealed and always clearly legible.
WARNING
Risk of fire or electrical shock
Objects of any kind pushed through openings in the shelves may touch
dangerous voltage points or short out parts that could result in a risk
of fire or electrical shock.
You must therefore ensure that
• objects of any kind are never pushed into the shelves
• liquid of any kind is never spilled on the shelves.
CAUTION
Risk of reduced component reliability due to
overheating
Inadequate removal of heat can cause reduced component reliability
and the system to operate outside its functionality specifications.
You must therefore ensure that
• the included fan units are operating
• the air intake area at the lower front of the rack is not obstructed
• the fan units are maintained properly
• the doors of the rack are closed when in operation.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 1-25
Issue 1, July 2005 See notice on first page
General installation warnings Safety
CAUTION
ESD hazard
Electronic components can be destroyed by electrostatic discharge.
Hold packs only at the edges or on the insertion and removal
facilities. Always observe the ESD instructions (see “Electrostatic
discharge considerations” (1-10)).
CAUTION
Condensation causes malfunctioning
Condensation can occur in the AnyMedia ® Access System, especially
during transport on moving from the outside to closed rooms; this can
cause malfunctioning of the packs.
Ensure that packs and shelves have reached room temperature
and are dry before taking them into operation.
....................................................................................................................................................................................................................................
1-26 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Safety
WARNING
Risk of injury due to untrained personnel
Installation and maintenance procedures must be followed and
performed by trained personnel only.
Do not allow non-service personnel to access electrical wiring.
Read and understand all instructions and warning labels. Follow
all warnings and instructions marked on the product and in the
manuals.
WARNING
Electric shock hazard
The AnyMedia ® Access System can be fed by ringing voltages of
57 V DC maximum superimposed by 105 V AC maximum. Touching
live ringing cables will shock or cause serious injury or death. This
applies to the cabling from the external ringing source up to the
shelves.
Take care when servicing in this area. Follow all safety warnings
and local regulation practices.
WARNING
Risk of injury due to touching uninsulated cables
Never touch uninsulated telecommunication wires or terminals unless
the telecommunication line has been disconnected at the Z, E1,
E3/DS3, xDSL test or alarm interface. Never touch uninsulated wiring
or terminals carrying direct current or ringing current or leave this
wiring exposed.
Protect and tape those wires and terminals to avoid risk of fire,
electrical shock, and injury to service personnel.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 1-27
Issue 1, July 2005 See notice on first page
General wiring warnings Safety
WARNING
Risk of injury due to installation of cables during a
storm or in wet locations
Never install telecommunication wiring during a lightning storm.
Never install telecommunication connections in wet locations.
WARNING
Risk of injury due to disconnected ground
The installation must have an independent rack ground connection to
the building ground/protective earth for indoor applications.
Grounding circuit continuity is vital for safe operation of the
AnyMedia ® Access System. The framework must be correctly
connected to the protective earth before the start of work.
Never operate the AnyMedia ® Access System or a single shelf
with a disconnected ground.
CAUTION
Destruction of components due to installed cables
without protection
All a/b-cables, E1-, E3/DS3, xDSL-cables and the alarming
cabling should not leave the building premises unless connected
to telecommunication devices providing primary protection (for
example protector blocks with gas discharge tubes) as applicable.
CAUTION
Laser hazard
The AnyMedia ® Access System can operate with invisible laser
radiation. Laser radiation can cause considerable injuries to the eyes.
Never look into the end of an exposed fiber or optical connector
of a pack as long as the optical source is switched on. This
applies particularly to the connections of the optical packs.
Always observe the laser warning instructions in “Laser safety”
(1-17).
....................................................................................................................................................................................................................................
1-28 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
General wiring warnings Safety
CAUTION
Destruction of the detector diodes caused by
excessive input power
Connecting the output and input of optical packs with a transmit
power in excess of -3 dBm over short distances can cause the
destruction of the detector diodes, as the input power is then too high.
Use an optical attenuator of approx. 15 dB when establishing
connections over short distances for the AFMO pack.
CAUTION
Destruction of components due to a supply voltage
of incorrect polarity or a supply voltage which is too
high
The AnyMedia ® Access System operates at a nominal voltage of
–48 V DC. The permissible tolerance range is −40.5 V to −57 V
DC.
Ensure that the supply voltage has the correct range and polarity
before connecting the voltage. The AnyMedia ® Access System
should be operated only from the type of power source indicated
on the marking label. Ensure that fuses will be replaced with the
same type and rating of fuse. Never connect the AnyMedia ®
Access System to −60 V DC.
CAUTION
Risk of injury if only one −48 V DC power feeder is
disconnected
The AnyMedia ® Access System may be equipped with two −48 V DC
input power feeders. Switching off one power feeder will not
de-energize the AnyMedia ® Access System.
Switch off both power feeders when removing power from the
AnyMedia ® Access System.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 1-29
Issue 1, July 2005 See notice on first page
General wiring warnings Safety
CAUTION
Destruction of packs in the event of a short circuit
A short circuit in the AnyMedia ® Access System can cause
destruction of electronic components and thus malfunctioning of the
complete system.
You must therefore not use objects such as a screwdriver in the
pack area. Never push objects of any kind into this product
through slots as they may touch dangerous voltage points or
cause a short circuit.
CAUTION
ESD hazard
Electronic components can be destroyed by electrostatic discharge.
Hold packs only at the edges or on the insertion and removal
facilities. Always observe the ESD instructions (see “Electrostatic
discharge considerations” (1-10)).
CAUTION
Fiber micro defects and/or cable break with a bending
radius less than 30 mm
There is a risk of causing micro defects in the single fiber or a risk of
a cable break if the bending radius of optical fiber cables is less than
about 30 mm. Micro defects can increase the fiber attenuation and
reduce the long term stability.
Ensure that the bending radius for the single fiber is not less
than 30 mm. Always use the special protective spiral wrap if the
fiber pigtails to the optical packs is equipped with. For the office
fiber cable the allowed bending radius depending on the cable
used must be observed.
....................................................................................................................................................................................................................................
1-30 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
General wiring warnings Safety
CAUTION
Destruction of components by incorrect handling
Proper function of the AnyMedia ® Access System is only possible by
the use of the correct circuit packs.
Before replacing a circuit pack, check the identification code to
ensure that the proper pack is being used.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 1-31
Issue 1, July 2005 See notice on first page
Safety
WARNING
Electric shock hazard
The AnyMedia ® Access System can be fed by ringing voltages of
57 V DC maximum superimposed by 105 V AC maximum. Touching
live ringing cables will shock or cause serious injury or death. This
applies to the cabling from the external ringing source up to the
shelves.
Take care when servicing in this area. Follow all safety warnings
and local regulation practices.
WARNING
Destruction of components due to long power and
ringing cables without filtering
Overvoltages can appear if long cables are used for external ringing
and powering. Power filter units are used to provide filtering and
power redundancy.
All ringing cables from external ringing sources where the cable
length exceeds 3 m shall be filtered to pass the resistibility test
according ITU-T K.41. For ringing the use of the ringing filter
unit is recommended.
CAUTION
PFUs in service are at an elevated temperature
When adding a PFU be careful not to touch other PFUs being in
service. They may be at an elevated temperature.
....................................................................................................................................................................................................................................
1-32 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Warnings for taking the power supply into Safety
operation
CAUTION
Destruction of components due to a supply voltage
of incorrect polarity or a supply voltage which is too
high
The AnyMedia ® Access System operates at a nominal voltage of
−48 V DC. The permissible tolerance range is −40.5 V to −57 V
DC.
Ensure that the supply voltage has the correct range and polarity
before connecting the voltage (about –54 V for battery backed
DC distribution network). Ensure that fuses and circuit breakers
will be replaced with the same type and rating of fuse if required.
Never connect the AnyMedia ® Access System to −60 V DC.
CAUTION
Risk of injury if not all the −48 V DC power feeders
are disconnected
The AnyMedia ® Access System may be equipped with more than one
−48 V DC input power feeders. Switching off or disconnecting some
of the power feeders will not de-energize all shelves in the
AnyMedia ® Access System.
Switch off all circuit breakers providing connection to DC power
distribution network when removing power from the AnyMedia ®
Access System.
CAUTION
ESD hazard
Electronic components can be destroyed by electrostatic discharge.
Hold packs only at the edges or on the insertion and removal
facilities. Always observe the ESD instructions (see “Electrostatic
discharge considerations” (1-10)).
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 1-33
Issue 1, July 2005 See notice on first page
Warnings for taking the power supply into Safety
operation
CAUTION
Risk of fire in the event of a short circuit
A short circuit can cause a fire in the AnyMedia ® Access System.
Protect all supply lines with line circuit-breakers matched to the
load of the shelf equipment.
CAUTION
Destruction of packs in the event of a short circuit
A short circuit in the AnyMedia ® Access System can cause
destruction of electronic components and malfunctioning.
You must therefore not use objects such as a screwdriver in the
pack area. Never push objects of any kind into this product
through slots as they may touch dangerous voltage points or
cause a short circuit.
CAUTION
Destruction of components by incorrect handling
The power should be turned off before inserting or removing a pack,
unless otherwise specified.
Before replacing a pack, check the identification code to ensure
that the proper pack is being used.
CAUTION
Condensation causes malfunctioning
Condensation can occur in the AnyMedia ® Access System, especially
during transport on moving from outside to closed rooms; this can
cause malfunctioning of the packs.
Ensure that packs and shelves have reached room temperature
and are dry before taking them into operation.
....................................................................................................................................................................................................................................
1-34 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Warnings for taking the power supply into Safety
operation
CAUTION
Damage to packs under extreme environmental conditions
Extreme environmental conditions can damage packs and cause
malfunctioning.
Ensure that the temperature limits shown in the figure below
according to ETS 300 019-1-3, climatic class 3.1E are complied
with during indoor operation in locations as telecommunication
centers. Icing, condensation and influence by animals or mould
growth is not allowed. Always keep the packs in the Lucent
original packaging until the packs have to be installed.
+50
+40
+30 29
-10
-20 1.0
-30
Relative
humidity [%]
0 10 20 30 40 50 60 70 80 90 100
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 1-35
Issue 1, July 2005 See notice on first page
Safety
WARNING
Risk of injury due to unsecured rack
An unpacked rack, including doors, without shelves weighs up to 50
kg and can cause considerable injuries if it is knocked over or
dropped. This can also cause serious damage to the rack and the
shelves.
Use a sturdy vehicle for transport and secure the rack against
dropping. At least two persons are required for lifting the rack.
Do not store packaged rack on top of one another.
CAUTION
ESD hazard
Electronic components can be destroyed by electrostatic discharge.
Packs must therefore always be kept in antistatic covers. Use the
original packaging if possible. Always observe the ESD
instructions (see “Electrostatic discharge considerations” (1-10)).
CAUTION
Adverse effect on operation due to incorrect packaging
Dampness and soiling can cause corrosion or tracking paths. This can
cause malfunctioning of the system components. Shocks can cause
damage.
Protect the system components against dampness, soiling and
shocks. Use the original packaging if possible.
CAUTION
Condensation causes malfunctioning
Condensation can occur in the AnyMedia ® Access System, especially
during transport on moving from outside to closed rooms; this can
cause malfunctioning of the packs.
Ensure that packs and shelves have reached room temperature
and are dry before taking them into operation.
....................................................................................................................................................................................................................................
1-36 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Warnings for transport and storage Safety
CAUTION
Damage to the system or to the packs under extreme
environmental conditions during transport
Extreme environmental conditions can damage packs and cause
malfunctioning.
Ensure that the limits shown in the figure below according to
ETS 300 019-1-2, climatic class 2.3 are complied with during
transport. Always keep the system or the packs in the Lucent
original packaging until the system or the packs have to be
installed.
+70
+60
+50
+40 60
+30
+20 Absolute
Permissible range humidity [g/m3]
+10
0
-10
-20
-30
-40 0.1
-50 Relative
humidity [%]
0 10 20 30 40 50 60 70 80 90 100
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 1-37
Issue 1, July 2005 See notice on first page
Warnings for transport and storage Safety
CAUTION
Damage to the system or to the packs under extreme
environmental conditions during storage
Extreme environmental conditions can damage packs and cause
malfunctioning.
Ensure that the limits shown in the figure below according to
ETS 300 019-1-3, climatic class 1.2 are complied with during
storage. Always keep the system or the packs in the Lucent
original packaging until the system or the packs have to be
installed.
+20 Absolute
Permissible range humidity [g/m3]
+10
0
-10
-20
0.5
-30
-40
-50 Relative
humidity [%]
0 10 20 30 40 50 60 70 80 90 100
....................................................................................................................................................................................................................................
1-38 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
2 General information
Overview
....................................................................................................................................................................................................................................
Purpose The DC-powered rack for the AnyMedia® Access System is available
in two basic variants, that depend on the shelf types to be equipped.
This chapter provides an overview of the DC-powered racks including
the following items:
• Basic information on these racks, including the orderable rack
types, the standard rack delivery and optional kits for special
purposes
• A short description of the AnyMedia® ETSI V5 Shelf and the
AnyMedia® LAG 1900 Shelf and mandatory equipment.
Also discussed is the basic concept realization of the following
functions:
• Grounding
• Powering
• Ringing
• Clock distribution.
Then, some technical data are provided that may be relevant for
installation, and finally a list of tools and measuring instruments is
shown that may be required during installation..
Contents
Standard rack deliveries and optional kits 2-3
ETSI V5 Shelf 2-8
LAG 1900 Shelf 2-9
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 2-1
Issue 1, July 2005 See notice on first page
Overview General information
....................................................................................................................................................................................................................................
2-2 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
General information
These rack types are based on the same mechanical ETSI-based rack
constructionl. They are designed to accomodate top and bottom cable
access and include the internal cabling for three shelves.
Standard rack delivery for The standard rack delivery for the rack J1C293B-1 includes the
J1C293B-1 following components:
• ETSI rack (2200 mm high)
• Subrack for fuse panel and connection panel (RFCP) with
– Fan filter and clock distribution unit (FFCU)
– Rack connection panel for alarming
– Rack fuse panel (RFP)
– T-rail for mounting RFUs
• Internal cabling, including the cabling for 3 AnyMedia® ETSI V5
Shelves
• Kit for standard floor anchoring
• Kit for side and rear panels’ locking.
J1C293B-1 L3 includes three RFUs and the internal ringing cabling
to the shelves.
Note that shelves, baffles and fans are not included in the standard
delivery.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 2-3
Issue 1, July 2005 See notice on first page
Standard rack deliveries and optional kits General information
Rack J1C293B-1 L1 (front The following figure shows the front view of the rack, the sequence
view) of shelf mounting (from bottom to top) in the rack and roughly the
mounting positions of baffles, shelves and fans.
Rack connection
panel for alarming
RFCP
FFCU
....................................................................................................................................................................................................................................
2-4 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Standard rack deliveries and optional kits General information
Legend:
Standard rack delivery for The standard rack delivery for the rack J1C301B-1 includes the
J1C301B-1 following components:
• ETSI rack (2200 mm high)
• Rack connection panel RCP with
– One Passive Clock Distribution panel (PCD520)
– Alarm connection panel (ACP520)
– Power termination blocks
• Internal cabling, including the cabling for 3 AnyMedia® LAG
1900 Shelves
• Kit for standard floor anchoring
• Kit for side and rear panels’ locking.
Note that shelves, baffles and fans are not included in the standard
delivery.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 2-5
Issue 1, July 2005 See notice on first page
Standard rack deliveries and optional kits General information
Rack layout J1C301B-1 The following figure shows the rack layout and the shelf numbering
within the rack.
PCD
RCP
ACP
Fan 3
Shelf 3
Baffle 3
Fan 2
Shelf 2
Baffle 2
Fan 1
Shelf 1
Baffle 1
....................................................................................................................................................................................................................................
2-6 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Standard rack deliveries and optional kits General information
Optional kits Additionally the following kits are available, in order to meet special
purposes. If not specified otherwise, they may be used for all of the
described rack types.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 2-7
Issue 1, July 2005 See notice on first page
General information
ETSI V5 Shelf
....................................................................................................................................................................................................................................
IO_HDLC
IO_HDLC
IO_E1P
RING0
RING1
E1 DOWN
E1 DOWN
- 48A
- 48B
IO_E1
IO_E1
IO_E1
IO_E1
E1 UP
E1 UP
GPC
TAP
PFU
LAN
J2
Application pack
Application pack
Application pack
Application pack
Application pack
Application pack
AFM or NB-AP
COMDAC
COMDAC
OAP
CIU
1 2 1 01 02 03 04 05 06 08 09 10 11 12 13 14 15 16
COM-1 COM-2 CIU AP-1 AP-2 AP-3 AP-4 AP-5 AP-6 AP-7 AP-8 AP-9 AP-10 AP-11 AP-12 AP-13 AP-14 AP-15 AP-16
Mandatory equipment per In certain cases AnyMedia ® ETSI V5 Shelves mandatorily require
shelf some additional equipment per shelf:
• The use of a fan unit per shelf is always required with the
exception of shelves that are equipped with some POTS packs
only with an expected traffic rate of less than 0.25 Erlang.
• The Power Filter Unit (PFU501) is mandatory.
• In the case that resistibility test according ITU-T K.20 has to be
applied, the use of a PFU in the shelf and a RFU per shelf in the
RFCP of the rack is mandatory.
• one baffle per shelf.
For details refer to the Ordering Guide (363-211-144).
....................................................................................................................................................................................................................................
2-8 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
General information
LAG 1900 Shelf schematic For the installation of the LAG 1900 Shelf in the DC-powered rack,
the ETSI-based version of the shelf (J1C301AB-1 L2) is required.
Mandatory equipment per AnyMedia ® LAG 1900 Shelves mandatorily require some additional
shelf equipment :
• Two power filter units (PFU503) in the shelf
• One fan per shelf
• One baffle per shelf.
For details refer to the Ordering Guide (363-211-144).
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 2-9
Issue 1, July 2005 See notice on first page
General information
Overview This section discusses some functions and concepts which may impact
the installation activities. These are:
• Grounding
• Powering
• Ringing
• Clock distribution.
Powering Centralized powering is used for the shelves in the DC-powered racks.
For centralized powering an external - 48 V source is connected to the
two feeders of the AnyMedia® Access System. The external - 48 V
source supplies the shelves, and the fan units.
For centralized powering Power Filter Units (PFUs) are mandatory.
• In the AnyMedia® ETSI V5 Shelf one Power Filter Unit
(PFU501) is required in the upper row.
• In the AnyMedia® LAG 1900 Shelf two PFUs (PFU503) must be
equipped in the upper row.
The - 48 V voltage is primary fused by the AnyMedia® Access
System with tip-free circuit breakers
• with a nominal value of 25 A for the ETSI V5 Shelf
• with a nominal value of 30 A for the LAG 1900 Shelf
Only one power input of the shelf is connected to one circuit breaker.
Ringing (ETSI V5 Shelf) For the ETSI V5 Shelf, the ringing voltage (if required) always comes
from an external ringing source (centralized ringing). The use of
Ringing Filter Units (RFU100) is recommended.
If external ringing voltage is required in the shelves, use rack type
J1C293B-L3 which includes 3 RFUs and the internal cables from the
RFUs to the shelves. The RFUs are mounted at the Subrack for Fuse
Panel and Connection Panel (RFCP) on a T-rail.
....................................................................................................................................................................................................................................
2-10 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Functions and concepts General information
Ringing (LAG 1900 Shelf) For the LAG 1900 Shelf external (centralized) or local ringing can be
used.
For centralized ringing supply the ringing voltage comes from an
external ringing source. If the length of the external unshielded
ringing cable exceeds three meters (shielded 10 m) a ringing filter unit
(RFU503) has to be installed in the LAG 1900 Shelf.
If centralized ringing will be used, the optional kit for external ringing
is required.
For local ringing supply two ringing generator units (RGUs) of the
same type have to be equipped in the upper row of the LAG 1900
Shelf. The RGUs may be battery-backed (RGU500) or earth-backed
(RGU510).
Clock distribution (ETSI V5 Simplex station clock can be connected to the AnyMedia® Access
Shelf) Systems in the rack. The clock can be terminated via a balanced input
(120 Ω) or via an unbalanced coax input (75 Ω). In case of balanced
input (120 Ω) the clock will be connected to a Fan Filter and Clock
distribution Unit (FFCU) and distributed to the ETSI V5 Shelves. If
unbalanced coax input (75 Ω) will be used instead, the clock is
directly fed to the clock connector in the connector field of the
shelves.
Clock distribution (LAG Duplex redundant external office clock sources or simplex station
1900 Shelf) clock can be fed to the rack and distributed to the LAG 1900 Shelves.
The clock can be terminated via a balanced input (120 Ω) or via an
unbalanced coax input (75 Ω).
If simplex station clock will be used, the optional kit for station clock
is required. For duplex office clock, use the optional kit for office
clock (which also includes a second PCD520) instead.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 2-11
Issue 1, July 2005 See notice on first page
General information
Technical data
....................................................................................................................................................................................................................................
Rack weight and The following technical data apply to the DC-powered rack for ETSI
dimensions V5 and LAG 1900 Shelves:
Table 2-3 Technical data
Specification (valid for both rack types) Values
Dimensions (HxWxD) 2200 mm x 600 mm x 300 mm
Weight Minimum (without any shelf) Min 50 kg
Maximum (with three equipped Max. 250 kg
shelves)
Power supply Range -40.5 V to -57 V DC
Nominal value -48 V DC
Operating temperature Range -5°C to +45°C
Recommendation +25°C
Heat dissipation 500 W to 3600 W
(configuration dependent)
....................................................................................................................................................................................................................................
2-12 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
General information
Tools The tools and testing instruments required for the installation and to
perform some measurements and tests on the AnyMedia ® Access
System depend on the particular installation. The following table
provides an overview of the tools that may be required.
Table 2-4 Tools and testing instruments
Use for Tools Remarks
Basic ESD wrist strap
Wire cutters (up to 25 mm2) and strippers, diagonal cutting
pliers, coated-wire stripping tweezer, multi-purpose knife,
extension cable 5 m
Torque wrench (0-70 inch-lbs; 7 Nm)
Hand tool kit: screwdrivers sets for standard slotted, Pozidrive
and Phillips, wrenches sets (open-end, hexagon pin/balend),
universal and pointed pliers, flat and round file with handle, nut
drivers, level (350 mm) and back square, roll tape/folding rule (2
m) etc.
Large tool kit: hammers, claw bar, etc.
8 inch/20 cm long flathead screwdrivers (slotted 4 mm and
Phillips No. 1)
Waterproof fine line marker
Floor drilling equipment: roto-hammer or percussion drill with
sintered carbide/stone drills, 18-mm masonry bits
Wire-wrap tools: gun, bits for 20, 22, 24, and 26 gauges and for
0.8, 0.6, 0.5 and 0.4 mm
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 2-13
Issue 1, July 2005 See notice on first page
Tools and measuring/testing instruments General information
....................................................................................................................................................................................................................................
2-14 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
3 Mechanical installation
Overview
....................................................................................................................................................................................................................................
Contents
Rack installation and grounding 3-2
How to remove rack door and side panel 3-3
Standard floor mounting 3-5
Floor mounting for earthquake group 4 3-8
Wall mounting 3-11
Ceiling mounting 3-14
Mounting racks side-by-side 3-17
Mounting racks back-to-back 3-21
Optical cable duct mounting 3-25
Grounding 3-27
Shelf installation 3-30
Mounting the ETSI V5 Shelves into the rack 3-30
Mounting the LAG 1900 Shelves into the rack 3-33
Connecting the internal cables to the shelves 3-36
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 3-1
Issue 1, July 2005 See notice on first page
Mechanical installation
Overview
....................................................................................................................................................................................................................................
Purpose Use the following procedures for standard floor mounting, or for
special mounting, e.g. for earthquake zones or for wall mounting,
ceiling mounting or side-by-side or back to back mounting and for
grounding (applicable for both rack types).
Contents
How to remove rack door and side panel 3-3
Standard floor mounting 3-5
Floor mounting for earthquake group 4 3-8
Wall mounting 3-11
Ceiling mounting 3-14
Mounting racks side-by-side 3-17
Mounting racks back-to-back 3-21
Optical cable duct mounting 3-25
Grounding 3-27
....................................................................................................................................................................................................................................
3-2 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Rack installation and grounding Mechanical installation
Overview The following procedures may require the removal of the rack door or
a side panel. The next lines describe how to perform these procedures.
Remove a rack door Removing a rack door does not require any tools.
............................................................................................................................................................
............................................................................................................................................................
4 Carry the door to a save place where it does not disturb the
installation actions.
E ND OF STEPS
............................................................................................................................................................
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 3-3
Issue 1, July 2005 See notice on first page
Rack installation and grounding Mechanical installation
How to remove rack door and side panel
Remove a side panel Removing the side panels requires a 3 mm socket wrench.
............................................................................................................................................................
2 Firstly remove the hexagon sockets in the bottom row, than the screws
in the middle row and finally remove the hexagon sockets at the top
of the side panel.
............................................................................................................................................................
3 Carry the side panel to a save place where it does not disturb the
installation actions.
END OF STEPS
..............................................................................................................................................................................
....................................................................................................................................................................................................................................
3-4 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Rack installation and grounding Mechanical installation
Purpose Use this procedure for standard floor mounting with the standard kit
for floor anchoring that is shipped with the rack.
Floor space preparation Installation work for indoor applications can begin before the arrival
of the racks. Check the equipment room according to the drawing and
general recommendations. Check the room for dust before the
equipment arrives. Assure a clean installation area (if necessary in
consultation with the customer).
Schematics The following figure shows the plate layout of the ETSI-based rack.
Rear panel
42,75
Right panel
Left panel
191
300
All dimensions are in millimeters
12
10
Door
600
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 3-5
Issue 1, July 2005 See notice on first page
Rack installation and grounding Mechanical installation
Standard floor mounting
adjustable feet
anchors
....................................................................................................................................................................................................................................
3-6 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Rack installation and grounding Mechanical installation
Standard floor mounting
1 Drill the four necessary holes (10 mm) in the floor by using the
drilling jig.
............................................................................................................................................................
3 Remove the rack door as described in “How to remove rack door and
side panel” (3-3).
It´s recommended to keep the door unmounted until the cabling has
been completed.
............................................................................................................................................................
7 Tighten the screws in the anchor until the plate washer is flat against
the rack frame.
END OF STEPS
..............................................................................................................................................................................
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 3-7
Issue 1, July 2005 See notice on first page
Rack installation and grounding Mechanical installation
Purpose Use this procedure for earthquake zone group 4 floor mounting with
the earthquake anchor kit for floor anchoring as listed in “Optional
kits ” (2-7). This kit is not included in the standard rack delivery. It
must be ordered separately.
Schematics The following figure shows the plate layout of the ETSI-based rack.
Rear panel
42,75
Right panel
Left panel
191
300
All dimensions are in millimeters
12
10
Door
600
....................................................................................................................................................................................................................................
3-8 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Rack installation and grounding Mechanical installation
Floor mounting for earthquake group 4
adjustable feet
with anchor
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 3-9
Issue 1, July 2005 See notice on first page
Rack installation and grounding Mechanical installation
Floor mounting for earthquake group 4
1 Drill the four necessary holes (12 mm) in the floor by using the
drilling jig.
............................................................................................................................................................
7 Tighten the screws in until the plate washer is flat against the rack
frame.
END OF STEPS
..............................................................................................................................................................................
....................................................................................................................................................................................................................................
3-10 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Rack installation and grounding Mechanical installation
Wall mounting
....................................................................................................................................................................................................................................
Purpose Use this procedure for wall mounting with the kit for wall fastening
as listed in“Optional kits ” (2-7). This kit is not included in the
standard rack delivery. It must be ordered separately.
Schematics The following figure shows the mounting layout of the ETSI-based
rack.
39 cm
17 cm
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 3-11
Issue 1, July 2005 See notice on first page
Rack installation and grounding Mechanical installation
Wall mounting
mounting bolt
adjustable feet
....................................................................................................................................................................................................................................
3-12 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Rack installation and grounding Mechanical installation
Wall mounting
............................................................................................................................................................
5 Remove the rack door as described in “How to remove rack door and
side panel” (3-3).
It´s recommended to keep the door unmounted until the cabling has
been completed.
............................................................................................................................................................
8 Screw the mounting bolts in the anchor until the plate washer is flat
on the wall.
END OF STEPS
..............................................................................................................................................................................
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 3-13
Issue 1, July 2005 See notice on first page
Rack installation and grounding Mechanical installation
Ceiling mounting
....................................................................................................................................................................................................................................
Purpose Use this procedure for ceiling mounting with the kit for ceiling
fastening as listed in “Optional kits ” (2-7). This kit is not included in
the standard rack delivery. It must be ordered separately.
Schematics The following figure shows the mounting layout of the ETSI-based
rack.
attachment screws
....................................................................................................................................................................................................................................
3-14 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Rack installation and grounding Mechanical installation
Ceiling mounting
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 3-15
Issue 1, July 2005 See notice on first page
Rack installation and grounding Mechanical installation
Ceiling mounting
1 Fix the angles on the top of the shelf. Leave the attachment screws
loose.
............................................................................................................................................................
5 Remove the rack door as described in “How to remove rack door and
side panel” (3-3).
It´s recommended to keep the door unmounted until the cabling has
been completed.
............................................................................................................................................................
8 Screw the mounting bolts in the anchor until the plate washer is flat
on the ceiling.
............................................................................................................................................................
....................................................................................................................................................................................................................................
3-16 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Rack installation and grounding Mechanical installation
Purpose The assembly side by side kit as listed in “Optional kits ” (2-7) is
used to mount rack frames together side-by-side. This kit is not
included in the standard rack delivery. It must be ordered separately.
The side panels have to be removed first.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 3-17
Issue 1, July 2005 See notice on first page
Rack installation and grounding Mechanical installation
Mounting racks side-by-side
Layout line-up The following figure shows the mounting layout of the ETSI-based
rack.
....................................................................................................................................................................................................................................
3-18 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Rack installation and grounding Mechanical installation
Mounting racks side-by-side
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 3-19
Issue 1, July 2005 See notice on first page
Rack installation and grounding Mechanical installation
Mounting racks side-by-side
2 Remove the side panels on the rack sides (if applicable) that will be
connected to each other and remove the rack door as described in
“How to remove rack door and side panel” (3-3).
It´s recommended to keep the door unmounted until the cabling has
been completed.
............................................................................................................................................................
5 Connect the two racks at the top and bottom via angles as shown in
the figure above in detail B. Do not fix it tightly yet.
............................................................................................................................................................
....................................................................................................................................................................................................................................
3-20 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Rack installation and grounding Mechanical installation
Purpose The assembly back to back kit as listed in “Optional kits ” (2-7) is
used to mount rack frames together back to back. This kit is not
included in the standard rack delivery. It must be ordered separately.
The side panels have to be removed first.
Note: Back-to-back configuration is possible only with back panels
(rear-covers) installed for both racks.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 3-21
Issue 1, July 2005 See notice on first page
Rack installation and grounding Mechanical installation
Mounting racks back-to-back
Layout back-to-back The following figure shows the mounting layout of the ETSI-based
rack.
bracket
hexagon bolt
....................................................................................................................................................................................................................................
3-22 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Rack installation and grounding Mechanical installation
Mounting racks back-to-back
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 3-23
Issue 1, July 2005 See notice on first page
Rack installation and grounding Mechanical installation
Mounting racks back-to-back
6 Fasten the bracket of the mounting kit with the loosen hexagon bolt as
shown in the figure above in detail A.
END OF STEPS
..............................................................................................................................................................................
....................................................................................................................................................................................................................................
3-24 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Rack installation and grounding Mechanical installation
Purpose Use this procedure for mounting the optical cabel duct. The usage of
an optical cable duct is recommended always when fiber cables have
to be installed in the rack.
The optical cable duct is not included in the standard rack delivery. It
must be ordered separately. The right side panel has to be removed
first.
Schematics The cabel duct should be mounted in case of using optical fibers.
Mounting procedure Important! The optical cable duct as listed in “Optional kits ”
(2-7) must be ordered separately.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 3-25
Issue 1, July 2005 See notice on first page
Rack installation and grounding Mechanical installation
Optical cable duct mounting
....................................................................................................................................................................................................................................
3-26 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Rack installation and grounding Mechanical installation
Grounding
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 3-27
Issue 1, July 2005 See notice on first page
Rack installation and grounding Mechanical installation
Grounding
Schematic The rack metalwork must be connected via the grounding lug to the
bonding ring conductor. There are several possible grounding points
all over the rack.
....................................................................................................................................................................................................................................
3-28 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Rack installation and grounding Mechanical installation
Grounding
1 Depending on the grounding method use the best bonding point on the
rack.
............................................................................................................................................................
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 3-29
Issue 1, July 2005 See notice on first page
Mechanical installation
Shelf installation
....................................................................................................................................................................................................................................
3-30 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Shelf installation Mechanical installation
Mounting the ETSI V5 Shelves into the
rack
Schematic
Figure 3-16 Shelf mounting (ETSI V5)
RFP
Rack connection
panel for alarming
RFCP
FFCU
73
71
62
54
52
50
49
47
38
30
28
26
25
23
14
6
4
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 3-31
Issue 1, July 2005 See notice on first page
Shelf installation Mechanical installation
Mounting the ETSI V5 Shelves into the
rack
Legend:
Note that the numbering of the holes starts from the bottom of the rack.
2 Mount the cage nuts in the front rack frame using the numbering as
depicted in the figure above.
............................................................................................................................................................
3 Mount the heat baffles into the rack frame using the numbering as
depicted in the figure above.
............................................................................................................................................................
6 Mount the fans on the front rack frame using the numbering as
depicted in the figure above.
............................................................................................................................................................
7 Insert the PFU in the most right slot in the upper row of each shelf.
END OF STEPS
..............................................................................................................................................................................
....................................................................................................................................................................................................................................
3-32 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Shelf installation Mechanical installation
Purpose This section describes the mounting of the AnyMedia ® LAG 1900
Shelves, which include the fans, into a rack. Independent of whether
you install one, two, or three shelves, always start with shelf 1 which
has to be located in the lowest position.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 3-33
Issue 1, July 2005 See notice on first page
Shelf installation Mechanical installation
Mounting the LAG 1900 Shelves into the
rack
Schematic
Figure 3-17 Shelf mounting (LAG 1900)
Power/Ringing Circuit breaker blocks
termination blocks
PCD
RCP
ACP
Fan 3
13
22
Shelf 3
30
Baffle 3 33
Fan 2 34
38
47
Shelf 2
55
Baffle 2 58
Fan 1 59
63
72
Shelf 1
80
Baffle 1 83
84
....................................................................................................................................................................................................................................
3-34 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Shelf installation Mechanical installation
Mounting the LAG 1900 Shelves into the
rack
Legend:
Note that the numbering of the holes starts from top of the rack.
2 Mount the cage nuts in the front rack frame using the numbering as
depicted in the figure above.
............................................................................................................................................................
3 Mount the heat baffles into the rack frame using the numbering as
depicted in the figure above.
............................................................................................................................................................
6 Insert the two PFUs in the most right slots in the upper row of each
shelf.
............................................................................................................................................................
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 3-35
Issue 1, July 2005 See notice on first page
Shelf installation Mechanical installation
Purpose Internal cables are used to provide connection between the Rack
Connection Panel (RCP) or the Subrack for Fuse and Connection
Panel (RFCP) in the upper part of the rack and the individual shelves
/fans for:
• Powering
• External ringing
• External clock distribution
• Alarms
• Fans.
All internal cables (except the ringing and clock distribution cables for
rack type J1C301B-1) are factory assembled. At delivery they are
connected to the correct connectors at the rack connection panel (or
the rack fuse connection panel), routed through the rack and attached
to the rack near the positions where they have to be connected later.
The cables are labeled with
• The name of the destination connector in the shelf (e.g. J3)
• The cable specification (e.g. ED7C818-35 GR21A)
• The number of the destination shelf (e.g. shelf 3).
A cover plate closes the front of the connector field on the LAG 1900
Shelves. It has to be removed in order to get access to the connectors
below.
Important! Note that the shelf numbering starts with shelf 1 at
the bottom of the rack and ends up with shelf 3 in the highest
position.
Procedure ............................................................................................................................................................
1 For LAG 1900 Shelves remove the two screws from the cover plate
that closes the front of the connector field and then remove the cover
plate.
............................................................................................................................................................
2 Locate all free cable ends in the rack and connect them to the correct
destination connector in the correct shelf as labeled on the cable.
END OF STEPS
..............................................................................................................................................................................
....................................................................................................................................................................................................................................
3-36 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
4 Parts descriptions of connector
fields connectors and internal
cables
Overview
....................................................................................................................................................................................................................................
Purpose The purpose of this chapter is to describe parts that are relevant for
the installation of the rack, e.g. all connector fields and connectors in
the rack and the internal cabling.
The external cables and the requirements for those cables which have
to be manufactured are given during the applicable cabling procedures
in Chapter 5, “Cabling procedures”.
Contents
Subrack for fuse and connection panel (RFCP) - 4-3
Applicable for J1C293B-1
Power connections 4-5
Ringing connections 4-7
Fan Filter and Clock Distribution Unit (FFCU) 4-8
Rack connection panel for alarming 4-10
Rack connection panel (RCP) - Applicable for 4-14
J1C301B-1
Power and grounding connections 4-15
Ringing connections 4-18
Passive Clock Distribution panel (PCD520) 4-20
Alarm Connection Panel (ACP520) 4-24
ETSI V5 Shelf connector field 4-27
Power connectors (A1/B1) 4-30
E1 connectors (D1/E1/F1/G1) 4-32
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-1
Issue 1, July 2005 See notice on first page
Overview Parts descriptions of connector fields connectors and
internal cables
....................................................................................................................................................................................................................................
4-2 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Parts descriptions of connector fields connectors and
internal cables
Overview
....................................................................................................................................................................................................................................
Purpose This section provides information about the cabling of the Subrack for
Fuse and Connection Panel (RFCP) which is mounted in rack type
J1C293B-1, applicable for AnyMedia ® ETSI V5 Shelves.
The following parts are described below in more detail:
• Fan Filter and Clock Distribution Unit (FFCU)
• Rack connection panel for alarming
• Rack Fuse Panel (RFP)
Front view The figure below shows the front view of the Subrack for Fuse and
Connection Panel (RFCP).
Contents
Power connections 4-5
Ringing connections 4-7
Fan Filter and Clock Distribution Unit (FFCU) 4-8
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-3
Issue 1, July 2005 See notice on first page
Subrack for fuse and connection panel Parts descriptions of connector fields connectors and
(RFCP) - Applicable for J1C293B-1 internal cables
Overview
....................................................................................................................................................................................................................................
4-4 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Subrack for fuse and connection panel Parts descriptions of connector fields connectors and
(RFCP) - Applicable for J1C293B-1 internal cables
Power connections
....................................................................................................................................................................................................................................
Power cable connections The figure below shows the external power connections which must
be done for establishing a redundant power supply and the already
pre-installed internal power cables.
Pre-installed
internal cables
to V5 Shelf 1 to V5 Shelf 1
(connector A1) (connector B1)
to V5 Shelf 2 to V5 Shelf 2
(connector A1) (connector B1)
to V5 Shelf 3 to V5 Shelf 3
(connector A1) (connector B1)
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-5
Issue 1, July 2005 See notice on first page
Subrack for fuse and connection panel Parts descriptions of connector fields connectors and
(RFCP) - Applicable for J1C293B-1 internal cables
Power connections
Routing of the power The power cables must be routed as shown in the figure below.
cables
Figure 4-3 Routing of the power cables
Feed A
-
+
Feed B
+
-
Pre-installed
internal cables
Power cable information Information related to the internally pre-installed power cables is
given in section “Power connectors (A1/B1)” (4-30).
Requirements for the external power cables are provided in “Installing
-48 V power feeder cables” (5-116).
Grounding The AnyMedia ® Access System in the DC-powered rack for ETSI V5
Shelves is designed to work in meshed-BN environments according to
ETS 300 253.
....................................................................................................................................................................................................................................
4-6 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Subrack for fuse and connection panel Parts descriptions of connector fields connectors and
(RFCP) - Applicable for J1C293B-1 internal cables
Ringing connections
....................................................................................................................................................................................................................................
Overview Two options of the DC-powered rack for ETSI V5 Shelves are
orderable:
• without Ringing Filter Units (RFUs): J1C293B-1
• equipped with three RFUs: J1C293B-1, L3.
For the AnyMedia ® ETSI V5 Shelves the ringing voltage always
comes from an external ringing source (centralized ringing). The
Ringing Filter Units (RFUs) have to be used if unshielded power
cable length exceeds 3 m or if the shielded power cable length
exceeds 10 m.
If no narrowband services are required, no ringing connections are
necessary.
Cable connections The figure below shows rack type J1C293B-1, L3 with the already
pre-installed grounding wires as well as the internal ringing cables to
the V5 Shelves. The external ringing connections to the customeŕs
ringing source must be done during installation.
RNG
Connected to Terminals for customer's
V5 Shelf 1, J1 Connected to ringing voltage
Connected to V5 Shelf 3, J1
V5 Shelf 2, J1
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-7
Issue 1, July 2005 See notice on first page
Subrack for fuse and connection panel Parts descriptions of connector fields connectors and
(RFCP) - Applicable for J1C293B-1 internal cables
Overview External clock source can be connected to the Fan Filter and Clock
Distribution Unit (FFCU) and distributed to the ETSI V5 Shelves. The
clock is terminated via a termination connector for clock distribution
(balanced, 120 Ω).
Optionally an external clock terminated with 75 Ω may be used. In
this case the FFCU is bypassed and the clock is connected directly to
connector D2 on the shelf connection panel.
The figure below shows the combined Fan Filter and Clock
Distribution Unit (FFCU).
Connectors The FFCU is divided into two logical parts: the Clock Distribution
Field (CDF) and the Fan Filter Field (FFF).
The FFCU provides the following interfaces:
• For clock distribution (via 9-pin male SUB-D connector on the
CDF)
– Connector (1) for input of external clock, twisted pair
Supply clock signal from customers external clock source to
the rack.
– Three connectors (2, 3, 4) for distributing clock signals to
the ETSI V5 Shelves 1 to 3.
– Connector (5) for termination (dummy load).
....................................................................................................................................................................................................................................
4-8 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Subrack for fuse and connection panel Parts descriptions of connector fields connectors and
(RFCP) - Applicable for J1C293B-1 internal cables
Fan Filter and Clock Distribution Unit
(FFCU)
Dummy load connector or clock cable to the next
AnyMedia ® Access System
• For power distribution to the FFF:
– Connector J4
Powering the FFCU.
– Fan unit cable connectors J1 to J3
Powering each of the 3 fan units by a cable assembly
routing from the fan unit connectors J1 to the -48 OUT
connectors J1 to J3 of the FFF.
Cable routing The cables are routed as shown in the figure below.
Cable information Information related to the internally pre-installed station clock cables
is given in section “Station clock connector (D2)” (4-50).
Requirements for the external station clock cables are provided in
“Installing clock cables - J1C293B-1” (5-87).
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-9
Issue 1, July 2005 See notice on first page
Subrack for fuse and connection panel Parts descriptions of connector fields connectors and
(RFCP) - Applicable for J1C293B-1 internal cables
Overview The rack connection panel for alarming provides 161 wire wrap pins
which are divided in seven sections (A to G). Always two sections
contain the alarms of one ETSI V5 Shelf.
Cable connections The table below shows the different sections on the rack connection
panel for alarming and their connections.
....................................................................................................................................................................................................................................
4-10 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Subrack for fuse and connection panel Parts descriptions of connector fields connectors and
(RFCP) - Applicable for J1C293B-1 internal cables
Rack connection panel for alarming
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-11
Issue 1, July 2005 See notice on first page
Subrack for fuse and connection panel Parts descriptions of connector fields connectors and
(RFCP) - Applicable for J1C293B-1 internal cables
Rack connection panel for alarming
....................................................................................................................................................................................................................................
4-12 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Subrack for fuse and connection panel Parts descriptions of connector fields connectors and
(RFCP) - Applicable for J1C293B-1 internal cables
Rack connection panel for alarming
Cable information Information related to the alarm cables is given in section “Alarm
connectors (F2/J3)” (4-47).
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-13
Issue 1, July 2005 See notice on first page
Parts descriptions of connector fields connectors and
internal cables
Overview
....................................................................................................................................................................................................................................
Purpose This section provides information about the cabling of the Rack
Connection Panel (RCP) which is mounted in rack type J1C301B-1,
applicable for AnyMedia ® LAG 1900 Shelves.
The following parts are described below in more detail:
• Power and ringing termination blocks
• Passive Clock Distribution (PCD520) panel
• Alarm Connection Panel (ACP520).
Front view The figure below shows the front view of the RCP.
Contents
Power and grounding connections 4-15
Ringing connections 4-18
Passive Clock Distribution panel (PCD520) 4-20
Alarm Connection Panel (ACP520) 4-24
....................................................................................................................................................................................................................................
4-14 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Rack connection panel (RCP) - Applicable Parts descriptions of connector fields connectors and
for J1C301B-1 internal cables
Power cable connections The figure below shows all power connections which must be done
for establishing a redundant power supply and the already
pre-installed internal power cables.
+ +
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-15
Issue 1, July 2005 See notice on first page
Rack connection panel (RCP) - Applicable Parts descriptions of connector fields connectors and
for J1C301B-1 internal cables
Power and grounding connections
Routing of the power The power cables must be routed as shown in the figure below.
cables
Figure 4-10 Routing of the power cables
Feed A
- +
Pre-installed
internal cabling
Feed B
+
-
Grounding - meshed BN -> The AnyMedia ® Access System in the DC-powered rack for LAG
meshed IBN 1900 Shelves is designed to work in meshed-BN or meshed-IBN
environments according to ETS 300 253.
During mechanical installation the rack must be grounded with the
office ground as described in “Grounding” (3-27). All the other parts
(RCP, shelves, ...) are grounded as a result of the physical mounting
(physical/electrical connection of device and rack frame).
At delivery the AnyMedia ® Access System in the DC-powered rack
for LAG 1900 Shelves is prepared for meshed BN environments. If a
....................................................................................................................................................................................................................................
4-16 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Rack connection panel (RCP) - Applicable Parts descriptions of connector fields connectors and
for J1C301B-1 internal cables
Power and grounding connections
Power cable information Information related to the internally used power cables is given in
sections “Power connectors (J111/J112)” (4-56). Requirements for the
external power cables and on the fuses are provided in “Installing -48
V power feeder cables” (5-116).
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-17
Issue 1, July 2005 See notice on first page
Rack connection panel (RCP) - Applicable Parts descriptions of connector fields connectors and
for J1C301B-1 internal cables
Ringing connections
....................................................................................................................................................................................................................................
Overview For the LAG 1900 Shelves external or local ringing voltage can be
used. For local ringing the shelves have to be equipped with a
Ringing Generator Unit (RGU). If external ringing is used, no RGUs
are required within LAG 1900 Shelves. Instead, the optional ringing
kit is required and the connector termination blocks, jumpers, and
internal and external ringing cables have to be installed.
The external ringing voltage has to be connected to the first ringing
termination block and will be bridged from there to the other
termination blocks. Each termination block serves one LAG 1900
Shelf.
If the LAG 1900 Shelves have to be fed by different external ringing
sources, do not connect the jumpers and feed the ringing source to
each termination block separately.
Cable connections The figure below shows the power/ringing termination blocks with the
ringing blocks installed and all ringing connections which must be
done.
to/from external
ringing source
jumpers jumpers
Tip
Ring
....................................................................................................................................................................................................................................
4-18 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Rack connection panel (RCP) - Applicable Parts descriptions of connector fields connectors and
for J1C301B-1 internal cables
Ringing connections
Cable information Information related to the internal ringing cables is given in sections
“Ringing connector (J113)” (4-76) . Requirements for the external
ringing cables are provided in “Installing ringing cables - J1C301B-1”
(5-124).
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-19
Issue 1, July 2005 See notice on first page
Rack connection panel (RCP) - Applicable Parts descriptions of connector fields connectors and
for J1C301B-1 internal cables
Overview At delivery the RCP is equipped with one Passive Clock Distribution
panel (PCD520). External simplex station clock can be connected to
this PCD and distributed to the LAG 1900 Shelves. The clock can be
terminated via a balanced input (120 Ω) or via an unbalanced coax
input (75 Ω). The kit for station clock (ordering no. 849015904) is
required for internal cabling.
Optionally the shelves may be fed with external duplex office clock.
In this case use the kit for office clock (ordering no. 849015896)
which also includes a second PCD and the internal clock cables.
....................................................................................................................................................................................................................................
4-20 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Rack connection panel (RCP) - Applicable Parts descriptions of connector fields connectors and
for J1C301B-1 internal cables
Passive Clock Distribution panel (PCD520)
External timing reference The J109 connectors of the LAG 1900 Shelves are connected to a
distribution PCD520 output connector each. The clock is fed to both COMDACs.
The active COMDAC selects one of the clock signals.
to LAG shelf 3
(connector J109)
to LAG shelf 2
(connector J109)
to LAG shelf 1
(connector J109)
Twisted pair
(BAL)
from external
clock source 1
Coax (UNB)
(either Twisted pair
or Coax)
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-21
Issue 1, July 2005 See notice on first page
Rack connection panel (RCP) - Applicable Parts descriptions of connector fields connectors and
for J1C301B-1 internal cables
Passive Clock Distribution panel (PCD520)
Coax (UNB)
Coax (UNB)
The J109 connectors and in case of duplex office clock the J110
connectors of the LAG 1900 Shelves are connected to a PCD520
output connector each. The clock is fed to both COMDACs. The
active COMDAC selects one of the clock signals.
Cable routing The clock cables must be routed as shown in the following figure.
....................................................................................................................................................................................................................................
4-22 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Rack connection panel (RCP) - Applicable Parts descriptions of connector fields connectors and
for J1C301B-1 internal cables
Passive Clock Distribution panel (PCD520)
Note that the figure shows the RCP with two PCDs equipped, not the
standard delivery.
Internal
clock cables
Cable information Information related to the clock cables is given in “Installing clock
cables - J1C301B-1” (5-92).
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-23
Issue 1, July 2005 See notice on first page
Rack connection panel (RCP) - Applicable Parts descriptions of connector fields connectors and
for J1C301B-1 internal cables
Overview The Alarm Connection Panel (ACP520) provides 96 wire wrap pins
which are divided in six sections (A to F). Always two sections
contain the alarms of one LAG 1900 Shelf.
Cable connections The table below shows the different ACP sections and their
connections.
....................................................................................................................................................................................................................................
4-24 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Rack connection panel (RCP) - Applicable Parts descriptions of connector fields connectors and
for J1C301B-1 internal cables
Alarm Connection Panel (ACP520)
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-25
Issue 1, July 2005 See notice on first page
Rack connection panel (RCP) - Applicable Parts descriptions of connector fields connectors and
for J1C301B-1 internal cables
Alarm Connection Panel (ACP520)
Cable routing The alarm cables are routed as shown in the figure below.
Cable fixing
Cable information Information related to the alarm cables is given in section “Alarm
connectors (J107/J108)” (4-70) .
....................................................................................................................................................................................................................................
4-26 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Parts descriptions of connector fields connectors and
internal cables
Overview
....................................................................................................................................................................................................................................
Purpose This section provides information about the pin assignment of all
connectors located on the Shelf Connection Panel (SCP) of the ETSI
V5 Shelf and the appendant cabling.
Connector field The figure below shows the connector arrangement on the SCP of the
ETSI V5 Shelf.
A B C D E F G H J
A1 B1 C1 D1 E1 F1 G1 J1
(Ringing)
(-48VA) (-48VB) J2
Connector designations The table below lists all connectors of the SCP and their meaning.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-27
Issue 1, July 2005 See notice on first page
ETSI V5 Shelf connector field Parts descriptions of connector fields connectors and
Overview internal cables
Cable connections The figure below gives an overview about the cabling of the ETSI V5
Shelf.
to power
termination A B C D E F G H J
block A A1 B1 C1 D1 E1 F1 G1 J1
(RFCP, -48VA)
J2
D2 F2 H2 J3
....................................................................................................................................................................................................................................
4-28 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
ETSI V5 Shelf connector field Parts descriptions of connector fields connectors and
Overview internal cables
Cable routing All cables which shall be connected to the SCP of the ETSI V5 Shelf
must be routed through the right cut-out of the shelf as shown in the
figure below.
The following cables must be routed in the vertical cable ducts of the
rack to the SCP:
• Power cables
• Alarm cables
• Clock cable
• Ringing cable
• Fan cable.
Contents
Power connectors (A1/B1) 4-30
E1 connectors (D1/E1/F1/G1) 4-32
TAP connector (C1) 4-41
LAN connector (J2) 4-44
RTU connector (H2) 4-45
Alarm connectors (F2/J3) 4-47
Station clock connector (D2) 4-50
Ringing connector (J1) 4-52
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-29
Issue 1, July 2005 See notice on first page
ETSI V5 Shelf connector field Parts descriptions of connector fields connectors and
internal cables
Overview The internal power cables coming from the fuses on the RFCP must
be connected to these interfaces.
Connector data The power interfaces (A1/B1) are realized as 2-pin connectors (male).
A1 -48V
A2
A3 -48RTNE
(Common)
Internal pre-installed power The following table lists the internal pre-installed shielded power
cables cables to the power connectors A1/B1 in the ETSI V5 Shelves.
....................................................................................................................................................................................................................................
4-30 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
ETSI V5 Shelf connector field Parts descriptions of connector fields connectors and
Power connectors (A1/B1) internal cables
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-31
Issue 1, July 2005 See notice on first page
ETSI V5 Shelf connector field Parts descriptions of connector fields connectors and
internal cables
E1 connectors (D1/E1/F1/G1)
....................................................................................................................................................................................................................................
14 1 1DS1D1T
nc E1_1 port1
2 1DS1D1R
1DS1D2T 15
E1_1 port2 3 nc
1DS1D2R 16
17 4 1DS1D3T
nc E1_1 port3
18 5 1DS1D3R
1DS1D4T
E1_1 port4 6 nc
1DS1D4R 19
20 7 2DS1D1T
nc E1_2 port1
21 8 2DS1D1R
2DS1D2T
E1_2 port2
22 9 nc
2DS1D2R
23 10 2DS1D3T
nc E1_2 port3
24 11 2DS1D3R
2DS1D4T
E1_2 port4 12 nc
25
2DS1D4R
13 GRD
nc = not connected
....................................................................................................................................................................................................................................
4-32 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
ETSI V5 Shelf connector field Parts descriptions of connector fields connectors and
E1 connectors (D1/E1/F1/G1) internal cables
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-33
Issue 1, July 2005 See notice on first page
ETSI V5 Shelf connector field Parts descriptions of connector fields connectors and
E1 connectors (D1/E1/F1/G1) internal cables
14 1 3DS1D1T
nc E1_3 port1
2 3DS1D1R
3DS1D2T 15
E1_3 port2 3 nc
3DS1D2R 16
17 4 3DS1D3T
nc E1_3 port3
18 5 3DS1D3R
3DS1D4T
E1_3 port4 6 nc
3DS1D4R 19
20 7 4DS1D1T
nc E1_4 port1
21 8 4DS1D1R
4DS1D2T
E1_4 port2
22 9 nc
4DS1D2R
23 10 4DS1D3T
nc E1_4 port3
24 11 4DS1D3R
4DS1D4T
E1_4 port4 12 nc
25
4DS1D4R
13 GRD
nc = not connected
....................................................................................................................................................................................................................................
4-34 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
ETSI V5 Shelf connector field Parts descriptions of connector fields connectors and
E1 connectors (D1/E1/F1/G1) internal cables
14 1 1DS1U1T
nc E1_1 port1
2 1DS1U1R
1DS1U2T 15
E1_1 port2 3 nc
1DS1U2R 16
17 4 1DS1U3T
nc E1_1 port3
18 5 1DS1U3R
1DS1U4T
E1_1 port4 6 nc
1DS1U4R 19
20 7 2DS1U1T
nc E1_2 port1
21 8 2DS1U1R
2DS1U2T
E1_2 port2
22 9 nc
2DS1U2R
23 10 2DS1U3T
nc E1_2 port3
24 11 2DS1U3R
2DS1U4T
E1_2 port4 12 nc
25
2DS1U4R
13 GRD
nc = not connected
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-35
Issue 1, July 2005 See notice on first page
ETSI V5 Shelf connector field Parts descriptions of connector fields connectors and
E1 connectors (D1/E1/F1/G1) internal cables
....................................................................................................................................................................................................................................
4-36 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
ETSI V5 Shelf connector field Parts descriptions of connector fields connectors and
E1 connectors (D1/E1/F1/G1) internal cables
14 1 3DS1U1T
nc E1_3 port1
2 3DS1U1R
3DS1U2T 15
E1_3 port2 3 nc
3DS1U2R 16
17 4 3DS1U3T
nc E1_3 port3
18 5 3DS1U3R
3DS1U4T
E1_3 port4 6 nc
3DS1U4R 19
20 7 4DS1U1T
nc E1_4 port1
21 8 4DS1U1R
4DS1U2T
E1_4 port2
22 9 nc
4DS1U2R
23 10 4DS1U3T
nc E1_4 port3
24 11 4DS1U3R
4DS1U4T
E1_4 port4 12 nc
25
4DS1U4R
13 GRD
nc = not connected
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-37
Issue 1, July 2005 See notice on first page
ETSI V5 Shelf connector field Parts descriptions of connector fields connectors and
E1 connectors (D1/E1/F1/G1) internal cables
Cable specification
Figure 4-28 E1 cable (120 Ω)
The E1 feeder cables are listed inTable 5-6, “E1 feeder cables” (5-51).
....................................................................................................................................................................................................................................
4-38 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
ETSI V5 Shelf connector field Parts descriptions of connector fields connectors and
E1 connectors (D1/E1/F1/G1) internal cables
Jumper setting The IO_E1 packs must be configured via jumpers to a line impedance
of 75 Ω (unbalanced) or 120 Ω (balanced). The next two figures show
the two possible configurations.
1 3
1 3
1 3
1 3
1 3
1 3
1 3
1 3
1 3
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-39
Issue 1, July 2005 See notice on first page
ETSI V5 Shelf connector field Parts descriptions of connector fields connectors and
E1 connectors (D1/E1/F1/G1) internal cables
1 3
1 3
1 3
1 3
1 3
1 3
1 3
1 3
1 3
....................................................................................................................................................................................................................................
4-40 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
ETSI V5 Shelf connector field Parts descriptions of connector fields connectors and
internal cables
Overview The TAP connector can be used for different test applications. It
provides internal and external metallic test access to the ports and
drops of the application packs.
Connector data The TAP interface (C1) is realized as a 37-pin SUB-D connector
(male).
1 nc
nc 20
2 nc
nc 21
3 nc
nc 22
4 nc
nc
23
5 nc
nc
24
6 nc
25
nc
7 nc
nc 26
8 nc
27
nc
9 nc
nc 28
10
nc
nc 29
11
nc
nc 30
12
nc
nc 31
13
TAPB_SEIZE
TAPB_EQ_T1 32
14
TAPB_EQ_R1
TAPB_EQ_T2 33
15
TAPB_EQ_R2
TAPB_FAC_T2 34
16
TAPB_FAC_R2
TAPB_FAC_T1
35
17
TAPB_FAC_R1
TAPB_FAC_E 36
18
TAPB_FAC_M
37
TAPB_EQ_E 19
TAPB_EQ_M
nc = not connected
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-41
Issue 1, July 2005 See notice on first page
ETSI V5 Shelf connector field Parts descriptions of connector fields connectors and
TAP connector (C1) internal cables
....................................................................................................................................................................................................................................
4-42 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
ETSI V5 Shelf connector field Parts descriptions of connector fields connectors and
TAP connector (C1) internal cables
Cable specification
Figure 4-33 TAP cable
Cables available for order The following table lists all TAP cables which can be ordered.
Notes:
1. 8-pair cable. Is routed via the MDF and the normal AP cable to the
TAP10X.
2. 2-pair cable. Connects directly to the TAP10X.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-43
Issue 1, July 2005 See notice on first page
ETSI V5 Shelf connector field Parts descriptions of connector fields connectors and
internal cables
Connector data The LAN interface (J2) is realized as a 9-pin SUB-D connector
(female).
Front view
(contact side)
9 5 nc
nc
8 4 nc
nc
3 nc
LAN_TDN
7
6 2 LAN_TDP
LAN_RDN
1 LAN_RDP
nc = not connected
Cable specification This LAN cable has to be manufactured by the installer. The
requirements are provided in “LAN connection for narrowband
applications” (A-37).
....................................................................................................................................................................................................................................
4-44 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
ETSI V5 Shelf connector field Parts descriptions of connector fields connectors and
internal cables
Connector data The RTU interface (H2) is realized as a 9-pin SUB-D connector
(female).
Front view
(contact side)
9 5 GRD
nc
8 4 DTR
nc
3 TxD
nc
7
6 2 RxD
DSR
1 nc
nc = not connected
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-45
Issue 1, July 2005 See notice on first page
ETSI V5 Shelf connector field Parts descriptions of connector fields connectors and
RTU connector (H2) internal cables
Cable specification
Figure 4-36 RTU cable
....................................................................................................................................................................................................................................
4-46 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
ETSI V5 Shelf connector field Parts descriptions of connector fields connectors and
internal cables
Overview All the alarm inputs and outputs of the ETSI V5 shelves can be
connected via these interfaces to the Alarm Connection Panel (ACP)
enabling an individual customer-specific put through of the alarms.
Connector data The alarm output interface (F2) is realized as a 9-pin SUB-D
connector (male).
Front view
(contact side)
6 1 CR0_C
MJ2_NO
7 2 CR1_NC
MN0_C
3 CR2_NO
MN1_NC
8
9 4 MJ0_C
MN2_NO
5 MJ1_NC
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-47
Issue 1, July 2005 See notice on first page
ETSI V5 Shelf connector field Parts descriptions of connector fields connectors and
Alarm connectors (F2/J3) internal cables
Front view
(contact side)
9 5 TLM5
GRD
8 4 TLM4
TLM8
3 TLM3
TLM7
7
6 2 TLM2
TLM6
1 TLM1
Internal pre-installed alarm The following table lists all internal pre-installed alarm cables.
cabels
Table 4-20 Alarm cables (ETSI V5 Shelf)
Destination Equipment code
Alarm output connector F2
Shelf 3, F2 ED7C818-35 Gr7A
Shelf 2, F2 ED7C818-35 Gr7B
....................................................................................................................................................................................................................................
4-48 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
ETSI V5 Shelf connector field Parts descriptions of connector fields connectors and
Alarm connectors (F2/J3) internal cables
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-49
Issue 1, July 2005 See notice on first page
ETSI V5 Shelf connector field Parts descriptions of connector fields connectors and
internal cables
Overview Station clock signals coming from the Clock Distribution Panel (CDP)
which are terminated with 120 Ω can be connected to this interface.
Optionally an external 75 Ω cable may be connected directly to the
D2 connector (bypassing the CDP).
Connector data The station clock interface (D2) is realized as a 9-pin SUB-D
connector (male).
Front view
(contact side)
6 1 nc
nc
7 2 nc
GRD
3 GRD
SC_IN_R
8
9 4 SC_IN_T
nc
5 nc
nc = not connected
....................................................................................................................................................................................................................................
4-50 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
ETSI V5 Shelf connector field Parts descriptions of connector fields connectors and
Station clock connector (D2) internal cables
Internal pre-installed The following table lists the internal pre-installed station clock cables
station clock cables to the station clock connector D2 in the ETSI V5 Shelves.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-51
Issue 1, July 2005 See notice on first page
ETSI V5 Shelf connector field Parts descriptions of connector fields connectors and
internal cables
Overview Ringing signals coming from the RFU can be connected to this
interface. Note that this applies only to rack variant J1C293B-1, L3
with RFUs equipped and pre-installed ringing cables.
Connector data The ringing interface (J1) is realized as a 2-pin connector (male).
A1 RRG0
A2
A3 TRG0
Internal pre-installed The following table lists the internal pre-installed ringing cables (for
ringing cables rack type J1C293B-1, L3) to the ringing connector J1 in the ETSI V5
Shelves.
....................................................................................................................................................................................................................................
4-52 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Parts descriptions of connector fields connectors and
internal cables
Overview
....................................................................................................................................................................................................................................
Purpose This section provides information about the pin assignment of all
connectors located on the LAG 1900 Shelf connector field and the
appendant cabling.
Connector field A cover plate closes the front of the connector field. The figure below
shows the connector arrangement of the LAG 1900 Shelf connector
field which becomes visible when the cover plate has been removed.
P113
Ringing
J103
TAP
Connector designations The table below lists all connectors of the LAG 1900 Shelf connector
field and their meaning.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-53
Issue 1, July 2005 See notice on first page
LAG 1900 Shelf connector field Parts descriptions of connector fields connectors and
Overview internal cables
....................................................................................................................................................................................................................................
4-54 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
LAG 1900 Shelf connector field Parts descriptions of connector fields connectors and
Overview internal cables
Cable routing All cables which shall be connected to the LAG 1900 Shelf connector
field must be routed through the right cut-out of the shelf as shown in
the figure below.
Figure 4-42 Cable routing of the LAG 1900 Shelf connector field
The following cables must be routed in the vertical cable ducts of the
rack to the RCP:
• Power cables
• Alarm cables
• Clock cables
• Ringing cable.
Contents
Power connectors (J111/J112) 4-56
E1 connectors (J101/J102) 4-58
TAP connector (J103) 4-62
LAN connector (J104) 4-66
RTU connector (J106) 4-68
Alarm connectors (J107/J108) 4-70
Clock connectors (J109/J110) 4-73
Ringing connector (J113) 4-76
Fan connector (P114) 4-78
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-55
Issue 1, July 2005 See notice on first page
LAG 1900 Shelf connector field Parts descriptions of connector fields connectors and
internal cables
Overview The internal power cables coming from the RCP (power termination
blocks) must be connected to these interfaces.
Connector data The power interfaces (J111/J112) are realized as 2-pin connectors
(male).
A1 -48V
A2
A3 -48RTNE
(Common)
Cable specification
Figure 4-44 Power cable
....................................................................................................................................................................................................................................
4-56 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
LAG 1900 Shelf connector field Parts descriptions of connector fields connectors and
Power connectors (J111/J112) internal cables
Pre-installed power cables The following table lists the internal pre-installed shielded power
cables to the power connectors J111/J112 in the LAG 1900 Shelves.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-57
Issue 1, July 2005 See notice on first page
LAG 1900 Shelf connector field Parts descriptions of connector fields connectors and
internal cables
E1 connectors (J101/J102)
....................................................................................................................................................................................................................................
13 nc
nc
25
24 12 nc
nc
11 nc
nc 23
22 10 nc
nc
21 9 nc
2DS1D4R
E1_2 port4 8 2DS1D3R
2DS1D4T 20
E1_2 port3
7 2DS1D3T
2DS1D2R 19
E1_2 port2 18 6 2DS1D1R
2DS1D2T E1_2 port1
17 5 2DS1D1T
1DS1D4R
E1_1 port4 4 1DS1D3R
1DS1D4T 16
E1_1 port3
15 3 1DS1D3T
1DS1D2R
E1_1 port2 2 1DS1D1R
14
1DS1D2T E1_1 port1
1 1DS1D1T
nc = not connected
....................................................................................................................................................................................................................................
4-58 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
LAG 1900 Shelf connector field Parts descriptions of connector fields connectors and
E1 connectors (J101/J102) internal cables
13 nc
nc
25
24 12 nc
nc
11 nc
nc 23
22 10 nc
nc
21 9 nc
2DS1U4R
E1_2 port4 8 2DS1U3R
2DS1U4T 20
E1_2 port3
7 2DS1U3T
2DS1U2R 19
E1_2 port2 18 6 2DS1U1R
2DS1U2T E1_2 port1
17 5 2DS1U1T
1DS1U4R
E1_1 port4 4 1DS1U3R
1DS1U4T 16
E1_1 port3
15 3 1DS1U3T
1DS1U2R
E1_1 port2 2 1DS1U1R
14
1DS1U2T E1_1 port1
1 1DS1U1T
nc = not connected
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-59
Issue 1, July 2005 See notice on first page
LAG 1900 Shelf connector field Parts descriptions of connector fields connectors and
E1 connectors (J101/J102) internal cables
Cable specification
Figure 4-47 E1 cable
....................................................................................................................................................................................................................................
4-60 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
LAG 1900 Shelf connector field Parts descriptions of connector fields connectors and
E1 connectors (J101/J102) internal cables
The E1 feeder cables are listed in Table 5-6, “E1 feeder cables” (5-51)
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-61
Issue 1, July 2005 See notice on first page
LAG 1900 Shelf connector field Parts descriptions of connector fields connectors and
internal cables
Overview The TAP connector can be used for different test applications. It
provides internal and external metallic test access to the ports and
drops of the application packs.
Connector data The TAP interface (J103) is realized as a 37-pin SUB-D connector
(female).
1
TAPA_EQ_R1 20
TAPA_EQ_T1
TAPA_EQ_R2
2
21
3 TAPA_EQ_T2
TAPA_FAC_R2 22
4 TAPA_FAC_T2
TAPA_FAC_R1 23
TAPA_FAC_T1
TAPA_FAC_M
5
24
TAPA_FAC_E
6
TAPA_EQ_M 25
TAPA_EQ_E
7
TAPA_SEIZE 26 nc
8
nc 27
nc
9
nc 28
10 nc
nc 29
11 nc
nc
30 nc
12
nc
31
13 nc
TAPB_SEIZE 32
14 TAPB_EQ_T1
TAPB_EQ_R1 33
15 TAPB_EQ_T2
TAPB_EQ_R2 34
16 TAPB_FAC_T2
TAPB_FAC_R2 35
17 TAPB_FAC_T1
TAPB_FAC_R1 36
18 TAPB_FAC_E
TAPB_FAC_M 37
19 TAPB_EQ_E
TAPB_EQ_M
nc = not connected
....................................................................................................................................................................................................................................
4-62 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
LAG 1900 Shelf connector field Parts descriptions of connector fields connectors and
TAP connector (J103) internal cables
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-63
Issue 1, July 2005 See notice on first page
LAG 1900 Shelf connector field Parts descriptions of connector fields connectors and
TAP connector (J103) internal cables
Cable specification
Figure 4-49 TAP cable
Cables available for order The following table lists all TAP cables which can be ordered.
....................................................................................................................................................................................................................................
4-64 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
LAG 1900 Shelf connector field Parts descriptions of connector fields connectors and
TAP connector (J103) internal cables
Notes:
1. 2-pair cables. Connects directly to the TAP10X.
2. 8-pair cables. Routed via the MDF and the normal AP cable to the
TAP10X.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-65
Issue 1, July 2005 See notice on first page
LAG 1900 Shelf connector field Parts descriptions of connector fields connectors and
internal cables
Connector data The LAN interface (J104) is realized as a 9-pin SUB-D connector
(female).
Front view
(contact side)
9 5 nc
nc
8 4 nc
nc
3 nc
LAN_TDN
7
6 2 LAN_TDP
LAN_RDN
1 LAN_RDP
nc = not connected
....................................................................................................................................................................................................................................
4-66 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
LAG 1900 Shelf connector field Parts descriptions of connector fields connectors and
LAN connector (J104) internal cables
Cable specification
Figure 4-51 LAN cable
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-67
Issue 1, July 2005 See notice on first page
LAG 1900 Shelf connector field Parts descriptions of connector fields connectors and
internal cables
Connector data The RTU interface (J106) is realized as a 9-pin SUB-D connector
(female).
Front view
(contact side)
9 5 GRD
nc
8 4 DTR
nc
3 TxD
nc
7
6 2 RxD
DSR
1 nc
nc = not connected
....................................................................................................................................................................................................................................
4-68 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
LAG 1900 Shelf connector field Parts descriptions of connector fields connectors and
RTU connector (J106) internal cables
Cable specification
Figure 4-53 RTU cable
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-69
Issue 1, July 2005 See notice on first page
LAG 1900 Shelf connector field Parts descriptions of connector fields connectors and
internal cables
Overview All the alarm inputs and outputs of the LAG 1900 Shelves can be
connected via these interfaces to the Alarm Connection Panel (ACP)
enabling an individual customer-specific put through of the alarms.
Connector data The alarm interfaces (J107/J108) are realized as 9-pin SUB-D
connectors (female).
Front view
(contact side)
9 5 MJ1_NC
MN2_NO
8 4 MJ0_C
MN1_NC
3 CR2_NO
MN0_C
7
6 2 CR1_NC
MJ2_NO
1 CR0_C
....................................................................................................................................................................................................................................
4-70 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
LAG 1900 Shelf connector field Parts descriptions of connector fields connectors and
Alarm connectors (J107/J108) internal cables
Front view
(contact side)
1
TLM1 6
TLM6
TLM2
2
7
3 TLM7
TLM3 8
4 TLM8
TLM4 9
5 GRD
TLM5
Cable specification
Figure 4-56 Alarm output cable
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-71
Issue 1, July 2005 See notice on first page
LAG 1900 Shelf connector field Parts descriptions of connector fields connectors and
Alarm connectors (J107/J108) internal cables
Internal pre-installed alarm The following table lists all internal pre-installed alarm cables.
cables
Table 4-38 Available alarm cables (LAG 1900 Shelf)
Destination Equipment code
Alarm output connector J107
Shelf 3, J107 ED7C874-31 Gr5
Shelf 2, J107 ED7C874-31 Gr5A
Shelf 1, J107 ED7C874-31 Gr5B
Alarm input connector J108
Shelf 3, J108 ED7C874-31 Gr10
Shelf 2, J108 ED7C874-31 Gr10A
Shelf 1, J108 ED7C874-31 Gr10B
....................................................................................................................................................................................................................................
4-72 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
LAG 1900 Shelf connector field Parts descriptions of connector fields connectors and
internal cables
Overview Office clock signals coming from the Passive Clock Distribution
(PCD520) panels can be connected to these interfaces. Station clock
signals can only be connected to connector J109.
Connector data The clock interfaces (J109/J110) are realized as 9-pin SUB-D
connectors (female).
Front view
(contact side)
9 5 STACLKT
STACLKR
8 4 OFFCLK0T
OFFCLK0R
3 nc
nc
7
6 2 0CLKOUTT
0CLKOUTR
1 nc
nc = not connected
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-73
Issue 1, July 2005 See notice on first page
LAG 1900 Shelf connector field Parts descriptions of connector fields connectors and
Clock connectors (J109/J110) internal cables
Front view
(contact side)
9 5 nc
nc
8 4 OFFCLK1T
OFFCLK1R
3 nc
nc
7
6 2 1CLKOUTT
1CLKOUTR
1 nc
nc = not connected
Cable specification
Figure 4-60 Station clock cable
....................................................................................................................................................................................................................................
4-74 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
LAG 1900 Shelf connector field Parts descriptions of connector fields connectors and
Clock connectors (J109/J110) internal cables
Internal clock cables The clock cables are included in optionally orderable kits as specified
in “Installing clock cables - J1C301B-1” (5-92).
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-75
Issue 1, July 2005 See notice on first page
LAG 1900 Shelf connector field Parts descriptions of connector fields connectors and
internal cables
Overview For the LAG 1900 Shelf external or local ringing can be used.
External ringing signals coming from the RCP (ringing termination
blocks) can be connected to this interface. If external ringing voltage
is used and no RFUs are equipped in the shelf, two ringing jumpers
must be installed instead, in the RGU slots (see Figure 2-4,
“Schematic of an AnyMedia ® LAG 1900 Shelf” (2-9)) in positions
P301 and P302 as shown in the figure below.
Connector data The ringing interface (J113) is realized as a 4-pin molex connector
(tin plated).
RRGA 2 4
TRGA 1 3
....................................................................................................................................................................................................................................
4-76 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
LAG 1900 Shelf connector field Parts descriptions of connector fields connectors and
Ringing connector (J113) internal cables
Cable specification
Figure 4-64 Internal ringing cable
Internal ringing cables The internal ringing cables are included in the optional kit for external
ringing (849015888). For detailed information see “Installing ringing
cables - J1C301B-1” (5-124).
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-77
Issue 1, July 2005 See notice on first page
LAG 1900 Shelf connector field Parts descriptions of connector fields connectors and
internal cables
Connector data The fan interface (P114) is realized as a 10-pin molex connector (gold
plated).
nc nc nc nc nc
10 9 8 7 6
5 4 3 2 1
nc = not connected
nc GRD -48V_0
FANALM -48V_1
....................................................................................................................................................................................................................................
4-78 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Parts descriptions of connector fields connectors and
internal cables
Overview
....................................................................................................................................................................................................................................
Purpose This section provides information about the pin assignment of the
Circuit Pack (CP) and Application Pack (AP) connectors and the
appendant cabling.
Contents
CIU pack 4-80
AFME3 and AFMDS3 packs 4-83
AFME1 pack 4-88
AFMO pack 4-94
IPFM pack (for LAG 1900 Shelf only) 4-99
SHDSL application pack (LPS510) 4-103
Optical application pack (OAP) 4-108
VSIM application pack (for LAG Shelf only) 4-110
LPZ600 application pack (POTS VoIP) 4-112
Other application packs 4-115
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-79
Issue 1, July 2005 See notice on first page
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
CIU pack
....................................................................................................................................................................................................................................
CHAN/MON DROP The CHAN/MON interface is used for metallic test access to the port
connector hardware and for listening to an existing call.
The DROP interface is used for metallic test access to the subscriber
line.
DROP
S1/2
R1/2
R1/2
Note for dual Bantam jack: T1/2
outer: Screen (S1/2)
middle: R1/2 (ring wire FAC/EQ)
inner: T1/2 (tip wire FAC/EQ) T1/2
....................................................................................................................................................................................................................................
4-80 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
CIU pack
CIT connector The CIT connector is used for connecting a PC GSI (PC with
Graphical System Interface (GSI)). It is realized as a 9-pin SUB-D
connector (female).
Front view
(contact side)
1
nc 6
DSR
RxD
2
7
3 RTS
TxD 8
4 CTS
DTR 9
5 nc
GRD
nc = not connected
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-81
Issue 1, July 2005 See notice on first page
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
CIU pack
Cabling The figure below shows the cable connections for the CIU pack.
FAULT
ACTIVE
POW 1
POW 2
TC
MISC
ACO
LED TEST
to/from headphone
or
for metallic test access to the port hardware
for metallic test access to the subscriber line
CHAN/MON
DROP
to PC GSI
CIT
LED
Button
Required cables The following table lists the requirements for the CIU cables to the
CIT connector.
Table 4-44 Available CIU cables
Cable type Cable description Equipment code
PC cable Serial RS-232 cable with 9-pin SUB-D commercially available
(male)
....................................................................................................................................................................................................................................
4-82 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
Overview The AFME3 (LPA911) and AFMDS3 (LPA901) packs contain the
following connectors:
• Serial RS-232C connector
• 10Base-T LAN connector
• Two sets of E3 (AFME3 pack) or DS3 (AFMDS3 pack)
connectors.
Serial RS-232C connector The serial RS-232C connector is used for connecting a PC GSI (PC
with Graphical System Interface (GSI)) running the GSI BB software
for ATM xDSL applications. It is realized as a 9-pin SUB-D connector
(female).
Front view
(contact side)
1
nc 6
DSR
RxD
2
7
3 RTS
TxD 8
4 CTS
DTR 9
5 nc
GRD
nc = not connected
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-83
Issue 1, July 2005 See notice on first page
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
AFME3 and AFMDS3 packs
10Base-T LAN connector The 10Base-T LAN connector is used for connecting a management
system (e.g. PC GSI or NAM) via Ethernet. It is realized as a 8-pin
RJ45 connector (female).
Front view
(contact side)
8 nc
nc 7
6 LAN_RDN/RX-
nc 5
4 nc
LAN_RDP/RX+ 3
2 LAN_TDN/TX-
LAN_TDP/TX+ 1
E3/DS3 connectors The E3/DS3 connectors are used for connecting E3/DS3 signals. The
connectors TX1 and RX1 (upstream) must be connected via coax
cables to the ATM backbone. The connectors TX2 and RX2
(downstream) must be connected via coax cables to the next
daisy-chained AnyMedia ® Shelf.
....................................................................................................................................................................................................................................
4-84 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
AFME3 and AFMDS3 packs
RX-1
RX-2
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-85
Issue 1, July 2005 See notice on first page
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
AFME3 and AFMDS3 packs
Cabling The figure below shows the cable connections for the AFME3 and
AFMDS3 packs.
TX-1
RX-1
TX-2
RX-2
....................................................................................................................................................................................................................................
4-86 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
AFME3 and AFMDS3 packs
Cables The following table lists the cables to the AFME3/AFMDS3 which
can be used for management purposes. The external E3/DS3 cables
are shown in“Installing E3/DS3 cables for AFME3/AFMDS3 packs -
Overview” (5-9).
Table 4-47 Cables for management
Cable type Cable description Length Equipment code
PC cable Serial RS-232 cable with commercially
9-pin SUB-D (male) available
LAN cable LAN inband management 4 ft (≈ 1.2 m) ED7C829-32 Gr6 or
cable to connect NB/BB ED7C829-32 Gr6A1
Ethernet port (10Base-T,
crossover wiring), 9-pin
SUB-D (male)/RJ45 (male)
LAN cable to HUB or PC LAN cable RJ45 to RJ45 commercially
(straight through for HUB, available
crossover for PC)
Notes:
1. Orderable item required if inband management for narrowband is supported.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-87
Issue 1, July 2005 See notice on first page
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
AFME1 pack
....................................................................................................................................................................................................................................
Serial RS-232C connector The serial RS-232C connector is used for connecting a PC GSI (PC
with Graphical System Interface (GSI)) running the GSI BB software
for ATM xDSL applications. It is realized as a 9-pin SUB-D connector
(female).
Front view
(contact side)
1
nc 6
DSR
RxD
2
7
3 RTS
TxD 8
4 CTS
DTR 9
5 nc
GRD
nc = not connected
....................................................................................................................................................................................................................................
4-88 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
AFME1 pack
10Base-T LAN connector The 10Base-T LAN connector is used for connecting a management
system (e.g. PC GSI or NAM) via Ethernet. It is realized as a 8-pin
RJ45 connector (female).
Front view
(contact side)
8 nc
nc 7
6 LAN_RDN/RX-
nc 5
4 nc
LAN_RDP/RX+ 3
2 LAN_TDN/TX-
LAN_TDP/TX+ 1
E1 connector The E1 connector is used for connecting the E1 cable from the Digital
Distribution Frame (DDF) and provides 8 E1 ports
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-89
Issue 1, July 2005 See notice on first page
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
AFME1 pack
19
37
18 nc
nc 36
17 TE1D8R
RE1D8R 35
16 E1 port 8 (Tip)
E1 port 8 (Ring) TE1U8T
RE1U8T
34
15 TE1D7R
RE1D7R
33
E1 port 7 (Tip)
E1 port 7 (Ring)
14 TE1U7T
32
RE1U7T
13 TE1D6R
RE1D6R 31
12 E1 port 6 (Tip)
E1 port 6 (Ring) TE1U6T
30
RE1U6T
11 TE1D5R
RE1D5R 29 E1 port 5 (Tip)
10
E1 port 5 (Ring) TE1U5T
RE1U5T 28
9 TE1D4R
RE1D4R 27 E1 port 4 (Tip)
E1 port 4 (Ring)
8
TE1U4T
RE1U4T 26
7
TE1D3R
RE1D3R 25
E1 port 3 (Tip)
E1 port 3 (Ring) 6 TE1U3T
RE1U3T 24
5 TE1D2R
RE1D2R 23 E1 port 2 (Tip)
E1 port 2 (Ring) 4 TE1U2T
RE1U2T
22
3 TE1D1R
RE1D1R 21 E1 port 1 (Tip)
E1 port 1 (Ring)
2 TE1U1T
20
RE1U1T 1
nc
nc = not connected
....................................................................................................................................................................................................................................
4-90 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
AFME1 pack
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-91
Issue 1, July 2005 See notice on first page
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
AFME1 pack
Cabling The figure below shows the cable connections for the AFME1 pack.
E1 interface to DDF
Cables The following table lists the cable sto the AFME1 which can be used
for management purposes. The external E1 cables are shown in
“Installing the E1 cables to the AFME1 - Overview” (5-32).
Table 4-51 Cables for management
Cable type Cable description Length Equipment code
PC cable Serial RS-232 cable with commercially available
9-pin SUB-D (male)
....................................................................................................................................................................................................................................
4-92 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
AFME1 pack
Notes:
1. Orderable item required if inband management for narrowband is supported.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-93
Issue 1, July 2005 See notice on first page
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
AFMO pack
....................................................................................................................................................................................................................................
Serial RS-232C connector The serial RS-232C connector is used for connecting a PC GSI (PC
with Graphical System Interface (GSI)) running the GSI BB software
for ATM xDSL applications. It is realized as a 9-pin SUB-D connector
(female).
Front view
(contact side)
1
nc 6
DSR
RxD
2
7
3 RTS
TxD 8
4 CTS
DTR 9
5 nc
GRD
nc = not connected
....................................................................................................................................................................................................................................
4-94 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
AFMO pack
10Base-T LAN connector The 10Base-T LAN connector is used for connecting a management
system (e.g. PC GSI or NAM) via Ethernet. It is realized as a 8-pin
RJ45 connector (female).
Front view
(contact side)
8 nc
nc 7
6 LAN_RDN/RX-
nc 5
4 nc
LAN_RDP/RX+ 3
2 LAN_TDN/TX-
LAN_TDP/TX+ 1
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-95
Issue 1, July 2005 See notice on first page
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
AFMO pack
Optical STM-1/OC-3 The optical connectors are used for connecting STM-1/OC-3 signals
connectors from the optical ATM feeder interface. Each optical port supports two
single SC-type connectors or one duplex SC-type connector.
10B A
TX-1
RX-1
TX-2 Optical port 1
Optical port 2
RX-2
CROSS COUPLE
Cross-couple connector
....................................................................................................................................................................................................................................
4-96 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
AFMO pack
Cabling The figure below shows the cable connections for the AFMO pack.
LPA920
n:m
FLT
ACTV
RTH4455AAB
ALM
FAC1
FAC2
CONSOLE
to PC GSI for ATM xDSL applications
Serial port (RS-232C)
(Serial interface)
10BASE-T
LAN (10Base-T) to PC GSI for ATM xDSL applications
(Ethernet interface)
Cables The following table lists the cables to the AFMO which can be used
for management purposes. The external fiber cables are shown in
“Installing fiber cables for AFMO packs - Overview” (5-54).
Table 4-54 Cables for management
Cable type Cable description Length Equipment code
PC cable Serial RS-232 cable with 9-pin commercially available
SUB-D (male)
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-97
Issue 1, July 2005 See notice on first page
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
AFMO pack
....................................................................................................................................................................................................................................
4-98 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
Serial RS-232C connector The serial RS-232C connector is used for connecting a PC GSI (PC
with Graphical System Interface (GSI)) running the GSI BB software
for ATM VoIP applications. It is realized as a 9-pin SUB-D connector
(female).
Front view
(contact side)
1
nc 6
DSR
RxD
2
7
3 RTS
TxD 8
4 CTS
DTR 9
5 nc
GRD
nc = not connected
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-99
Issue 1, July 2005 See notice on first page
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
IPFM pack (for LAG 1900 Shelf only)
10Base-T LAN connector The 10Base-T LAN connector is used for connecting a management
system (e.g. PC GSI or NAM) via Ethernet. It is realized as a 8-pin
RJ45 connector (female).
Front view
(contact side)
8 nc
nc 7
6 LAN_RDN/RX-
nc 5
4 nc
LAN_RDP/RX+ 3
2 LAN_TDN/TX-
LAN_TDP/TX+ 1
....................................................................................................................................................................................................................................
4-100 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
IPFM pack (for LAG 1900 Shelf only)
100Base-T LAN connectors The 100Base-T LAN connectors are used for connecting external
100Base-T LAN equipment. It is realized as a 8-pin RJ45 connector
(female).
Front view
(contact side)
8 nc
nc 7
6 LAN_RDN/RX-
nc 5
4 nc
LAN_RDP/RX+ 3
2 LAN_TDN/TX-
LAN_TDP/TX+ 1
Gigabit Interface Converter The Gigabit Interface Converter (GBIC) slots are used for attaching
slots separate GBICs as interfaces to the GbE uplinks. They are designed as
1000Base-SX/LX uplink interfaces.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-101
Issue 1, July 2005 See notice on first page
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
IPFM pack (for LAG 1900 Shelf only)
Cabling The figure below shows the cable connections for the IPFM pack.
Cables The following table lists the cables to the IPFM which can be used
for management purposes. Details on the uplinks are shown in
“Installing IPFM uplink feeders” (5-82).
Table 4-58 Cables for management
Cable type Cable description Length Equipment code
PC cable Serial RS-232 cable with 9-pin commercially available
SUB-D (male)
LAN cable to LAN cable RJ45 to RJ45 (straight commercially available
HUB or PC through for HUB, crossover for
PC)
....................................................................................................................................................................................................................................
4-102 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-103
Issue 1, July 2005 See notice on first page
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
SHDSL application pack (LPS510)
SHDSL connector for This connector is used for SHDSL cables to SHDSL application packs
8 ports (LPS510) with 8 duplex-mode SHDSL ports. The figure below shows
the pin assignment of this connector.
Short
Orange binder Blue binder
68 34
Ring BL/Y BL/Y Ring
R32 67 33 R16
not used Tip Y/BL Y/BL Tip not used
T32 T16
S/BK S/BK
R31 R15
not used BK/S BK/S not used
T31 T15
BR/BK BR/BK
R30 R14
not used BK/BR BK/BR not used
T30 T14
G/BK G/BK
R29 R13
not used BK/G BK/G not used
T29 T13
O/BK O/BK
R28 R12
not used BK/O BK/O not used
T28 T12
BL/BK BL/BK
R27 R11
not used BK/BL BK/BL not used
T27 T11
S/R S/R
R26 R10
not used R/S R/S not used
T26 T10
BR/R BR/R
R25 R9
not used R/BR R/BR not used
T25 T9
G/R G/R
R24 R8
not used R/G SHDSL8 copper pair
R/G
T24 T8 for SHDSL port 8
O/R O/R
R23 R7 SHDSL7 copper pair
not used R/O R/O
T23 T7 for SHDSL port 7
BL/R BL/R
R22 R6
not used R/BL R/BL SHDSL6 copper pair
T22 T6 for SHDSL port 6
S/W S/W
R21 R5
not used W/S W/S SHDSL5 copper pair
T21 T5 for SHDSL port 5
BR/W BR/W
R20 R4 SHDSL4 copper pair
not used W/BR W/BR
T20 T4 for SHDSL port 4
G/W G/W
R19 R3 SHDSL3 copper pair
not used W/G W/G
T19 T3 for SHDSL port 3
O/W O/W
R18 R2 SHDSL2 copper pair
not used W/O W/O
T18 T2 for SHDSL port 2
Ring BL/W BL/W Ring
R17 R1 SHDSL1 copper pair
not used Tip W/BL W/BL Tip
T17 T1 for SHDSL port 1
36 2
35 1
For the SHDSL AP only 8 SHDSL ports with 1 The top pair (34 & 68)
copper pair each are used. Each of them have a Short and bottom pair (1 & 35)
transmission rate of 192 to 2048 kbit/s (line rate are each shorted to alert the
up to 2064 baud). circuit pack that the connector
By default SHDSL ports 5 to 8 are routed is attached
to the unstructured E1 ports 1 to 4 until
other provisioning. For pinning of
these E1 ports see next figure. Wiring side
....................................................................................................................................................................................................................................
4-104 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
SHDSL application pack (LPS510)
Short
1 11
DSX1D1R BK 2 12 BK DSX1U1R
Downstream side (Rx; receive) E1 port 1_D E1 port 1_U
3 13
DSX1D2R BK 4 14 BK DSX1U2R
E1 port 2_D E1 port 2_U
DSX1D2T WH 5 15 BR DSX1U2T
DSX1D3R BK 6 16 BK DSX1U3R
E1 port 3_D E1 port 3_U
DSX1D3T G 7 17 OR DSX1U3T
DSX1D4R BK 8 18 R DSX1U4R
E1 port 4_D E1 port 4_U
DSX1D4T BL 9 19 WH DSX1U4T
10 20
By default the unstructured E1 ports Short DSX1U4T stands for: DSX1 = E1 signal
are routed to the duplex SHDSL ports 5 to 8 until U = Upstream
until other provisioning. 4 = E1 port 4
T = tip wire
Wiring side
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-105
Issue 1, July 2005 See notice on first page
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
SHDSL application pack (LPS510)
Cabling The figure below shows the cable connections for the LPS510
application pack.
LPS510
n:m
FAULT
Cables available for order For the E1 cables refer to Table 5-3, “Length of E1 cables for the
SHDSL AP LPS510” (5-38).
As SHDSL cable use one of the shielded a/b-cables (1x32 pairs)
ED818-30 GR1x:
....................................................................................................................................................................................................................................
4-106 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
SHDSL application pack (LPS510)
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-107
Issue 1, July 2005 See notice on first page
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
Faceplate This application pack is used for fiber connecting from the shelf to
the Optical Controller Pack (OCP) in the ONU. The fiber of the
optical link is connected to the pack via an optical SC-type connector
located on the OAP faceplate (see figure below).
LPF5
00
FAULT
CLF
Optical parameters The table below shows the transmit/receive parameters for the laser
transmitter/receiver of the OAP which are identical to the parameters
of the OCP inside the ONU.
....................................................................................................................................................................................................................................
4-108 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
Optical application pack (OAP)
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-109
Issue 1, July 2005 See notice on first page
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
VSIM connector On the VSIM AP the same 32 ports a/b connector is used as for most
POTS APs. The pin assignment of this connector is shown in Figure
4-93, “Pin assignment (POTS AP cable connector, 32 ports)” (4-116)
....................................................................................................................................................................................................................................
4-110 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
VSIM application pack (for LAG Shelf
only)
Cabling The figure below shows the cable connections for the VSIM
application pack.
LPV417
Lucent
FAULT
UP2
UP1
EJECT
B34
A1
LIFT
TO
INSERT
CONNECTOR
Cables available for order The orderable cables are listed in Table 4-61, “Available a/b cables”
(4-129).
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-111
Issue 1, July 2005 See notice on first page
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
Overview The LPZ600 application pack (POTS VoIP) contains the following
connectors:
• POTS connector
• 10/100Base-T LAN connector (for stand-alone mode)
• Serial RJ45 connector (for stand-alone mode).
....................................................................................................................................................................................................................................
4-112 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
LPZ600 application pack (POTS VoIP)
POTS connector This connector provides POTS and VoIP service. The figure below
shows the pin assignment of this connector.
Short
Short
Wiring side
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-113
Issue 1, July 2005 See notice on first page
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
LPZ600 application pack (POTS VoIP)
Cabling The figure below shows the cable connections for the LPZ600
application pack.
LPZ600
FAULT
LAN
CONSOLE
Cables available for order The orderable cables are listed in Table 4-61, “Available a/b cables”
(4-129).
....................................................................................................................................................................................................................................
4-114 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
Faceplate The figure below is valid for all application packs except the OAP
(see section “Optical application pack (OAP)” (4-108)) and the
SHDSL application pack (see section “SHDSL application pack
(LPS510)” (4-103)).
AP connector
Use of the AP connectors The 68-pin cable connectors of the application packs and the
a/b-cables are uniformly designed and connected. The lower opposite
pins 1 and 35 and the upper opposite pins 33 and 68 are shorted for
checking if the cable is connected. Only the number of Tip/Ring wires
used differs per application pack.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-115
Issue 1, July 2005 See notice on first page
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
Other application packs
POTS application pack This connector is used for the application packs LPZ100, LPZ110,
connector (for up to 32 LPZ120, LPZ121, LPZ122, LPZ123 and LPP100 (24 Z ports). The
ports) figure below shows the pin assignment of this connector. The
orderable cables are listed in Table 4-61, “Available a/b cables”
(4-129).
Short
Orange binder Blue binder
68 34
Ring BL/Y BL/Y Ring
R32 67 33 R16
Z port 32* Tip Y/BL Y/BL Tip Z port 16
T32 T16
S/BK S/BK
R31 R15
Z port 31* BK/S BK/S Z port 15
T31 T15
BR/BK BR/BK
R30 R14
Z port 30* BK/BR BK/BR Z port 14
T30 T14
G/BK G/BK
R29 R13
Z port 29* BK/G BK/G Z port 13
T29 T13
O/BK O/BK
R28 R12
Z port 28* BK/O BK/O Z port 12
T28 T12
BL/BK BL/BK
R27 R11
Z port 27* BK/BL BK/BL Z port 11
T27 T11
S/R S/R
R26 R10
Z port 26* R/S R/S Z port 10
T26 T10
BR/R BR/R
R25 R9
Z port 25* R/BR R/BR Z port 9
T25 T9
G/R G/R
R24 R8
Z port 24 R/G R/G Z port 8
T24 T8
O/R O/R
R23 R7
Z port 23 R/O R/O Z port 7
T23 T7
BL/R BL/R
R22 R6
Z port 22 R/BL R/BL Z port 6
T22 T6
S/W S/W
R21 R5
Z port 21 W/S W/S Z port 5
T21 T5
BR/W BR/W
R20 R4
Z port 20 W/BR W/BR Z port 4
T20 T4
G/W G/W
R19 R3
Z port 19 W/G W/G Z port 3
T19 T3
O/W O/W
R18 R2
Z port 18 W/O W/O Z port 2
T18 T2
Ring BL/W BL/W Ring
R17 R1
Z port 17 Tip W/BL W/BL Tip Z port 1
T17 36 2 T1
35 1
For the AP Periodic Pulse Metering The top pair (34 & 68)
(LPP100B) only 24 Z ports are used. Short and bottom pair (1 & 35)
are each shorted to alert the
The LPZ110 is equipped with 32 circuit pack that the connector
low-pass filters (G.992 Annex A) for is attached.
Y-connecting to the ADSL32p AP (LPA432)
with 32 high-pass filters (G.992 AnnexA).
Wiring side
POTS application pack This connector is used for the application packs LPZ640 and LPZ641.
connector (for 64 ports) The figures below show the pin assignment of this connector. The
....................................................................................................................................................................................................................................
4-116 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
Other application packs
P1
P2
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-117
Issue 1, July 2005 See notice on first page
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
Other application packs
Short
Short
Wiring side
....................................................................................................................................................................................................................................
4-118 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
Other application packs
Short
Short
Wiring side
Test application pack This connector is used for the application packs TAP100 and TAP
connector 101. The figure below shows the pin assignment of this connector.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-119
Issue 1, July 2005 See notice on first page
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
Other application packs
The orderable cables are listed in Table 4-61, “Available a/b cables”
(4-129).
Short
Orange binder Blue binder
68 34
Ring BL/Y BL/Y Ring
R32 67 33 R16
not used Tip Y/BL Y/BL Tip not used
T32 T16
S/BK S/BK
R31 R15
not used BK/S BK/S not used
T31 T15
BR/BK BR/BK
R30 R14
not used BK/BR BK/BR not used
T30 T14
G/BK G/BK
R29 R13
not used BK/G BK/G not used
T29 T13
O/BK O/BK
R28 R12
not used BK/O BK/O not used
T28 T12
BL/BK BL/BK
R27 R11
not used BK/BL BK/BL not used
T27 T11
S/R S/R
R26 R10
not used R/S R/S not used
T26 T10
BR/R BR/R
R25 R9
not used R/BR R/BR not used
T25 T9
G/R G/R
R24 R8
not used R/G R/G not used
T24 T8
O/R O/R
R23 R7
not used R/O R/O not used
T23 T7
BL/R BL/R
R22 R6
not used R/BL R/BL not used
T22 T6
S/W S/W
R21 R5
not used W/S W/S not used
T21 T5
BR/W BR/W
R20 R4
not used W/BR W/BR not used
T20 T4
G/W G/W
R19 R3
not used W/G W/G not used
T19 T3
O/W O/W
R18 R2
not used W/O W/O TAP Facility (FAC)*
T18 T2
Ring BL/W BL/W Ring
R17 R1
not used Tip W/BL W/BL Tip TAP Equipment (EQ)
T17 36 2 T1
35 1
The top pair (34 & 68) *For the TAP10x the test pathTAP_FAC
and bottom pair (1 & 35) Short is currently not supported.
are each shorted to alert the
circuit pack that the connector
is attached.
For the TAP10x
only 2 a/b ports are used
Wiring side
ISDN application pack This connector is used for the following application packs:
connector
• LPU112 (12 U ports)
• LPU132 (32 U ports)
• LPU430 (16 U ports, ETSI V5 Shelf only)
....................................................................................................................................................................................................................................
4-120 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
Other application packs
Short
Orange binder Blue binder
68 34
Ring BL/Y BL/Y Ring
R32 67 33 R16
ISDN U port 32 Tip Y/BL Y/BL Tip ISDN U port 16
T32 T16
S/BK S/BK
R31 R15
ISDN U port 31 BK/S BK/S ISDN U port 15
T31 T15
BR/BK BR/BK
R30 R14
ISDN U port 30 BK/BR BK/BR ISDN U port 14
T30 T14
G/BK G/BK
R29 R13
ISDN U port 29 BK/G BK/G ISDN U port 13
T29 T13
O/BK O/BK
R28 R12
ISDN U port 28 BK/O BK/O ISDN U port 12
T28 T12
BL/BK BL/BK
R27 R11
ISDN U port 27 BK/BL BK/BL ISDN U port 11
T27 T11
S/R S/R
R26 R10
ISDN U port 26 R/S R/S ISDN U port 10
T26 T10
BR/R BR/R
R25 R9
ISDN U port 25 R/BR R/BR ISDN U port 9
T25 T9
G/R G/R
R24 R8
ISDN U port 24 R/G ISDN U port 8
R/G
T24 T8
O/R O/R
R23 R7
ISDN U port 23 R/O R/O ISDN U port 7
T23 T7
BL/R BL/R
R22 R6
ISDN U port 22 ISDN U port 6
R/BL R/BL
T22 T6
S/W S/W
R21 R5
ISDN U port 21 W/S W/S ISDN U port 5
T21 T5
BR/W BR/W
R20 R4
ISDN U port 20 ISDN U port 4
W/BR W/BR
T20 T4
G/W G/W
R19 R3
ISDN U port 19 W/G W/G ISDN U port 3
T19 T3
O/W O/W
R18 R2
ISDN U port 18 W/O W/O ISDN U port 2
T18 T2
Ring BL/W BL/W Ring
R17 R1
ISDN U port 17 Tip W/BL W/BL Tip ISDN U port 1
T17 36 2 T1
35 1
For the ISDN AP Short The top pair (34 & 68)
- LPU112 only 12 U ports are used and bottom pair (1 & 35)
- LPU430 only 16 U ports are used are each shorted to alert the
- LPU508 only 8 U ports are used. circuit pack that the connector
is attached.
Wiring side
ADSL16p application pack This connector provides POTS service and is used for the application
connector (16 ports) pack LPA416. The figure below shows the pin assignment of this
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-121
Issue 1, July 2005 See notice on first page
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
Other application packs
Shot
Orange binder Blue binder
68 34
Ring BL/Y BL/Y Ring
R32 67 33 R16
Z port 16 Tip Y/BL Y/BL Tip Z port 8
T32 T16
S/BK S/BK
R31 R15
ADSL port 16 BK/S BK/S ADSL port 8
T31 T15
BR/BK BR/BK
R30 R14
Z port 15 BK/BR BK/BR Z port 7
T30 T14
G/BK G/BK
R29 R13
ADSL port 15 BK/G BK/G ADSL port 7
T29 T13
O/BK O/BK
R28 R12
Z port 14 BK/O BK/O Z port 6
T28 T12
BL/BK BL/BK
R27 R11
ADSL port 14 BK/BL BK/BL ADSL port 6
T27 T11
S/R S/R
R26 R10
Z port 13 R/S R/S Z port 5
T26 T10
BR/R BR/R Ring
R25 R9
ADSL port 13 R/BR R/BR Tip ADSL port 5
T25 T9
G/R G/R
R24 R8
Z port 12 R/G R/G Z port 4
T24 T8
O/R O/R
R23 R7
ADSL port 12 R/O R/O ADSL port 4
T23 T7
BL/R BL/R
R22 R6
Z port 11 R/BL R/BL Z port 3
T22 T6
S/W S/W
R21 R5
ADSL port 11 W/S W/S ADSL port 3
T21 T5
BR/W BR/W
R20 R4
Z port 10 W/BR W/BR Z port 2
T20 T4
G/W G/W
R19 R3
ADSL port 10 W/G W/G ADSL port 2
T19 T3
O/W O/W
R18 R2
Z port 9 W/O W/O Z port 1
T18 T2
Ring BL/W BL/W Ring
R17 R1
ADSL port 9 Tip W/BL W/BL Tip ADSL port 1
T17 36 2 T1
35 1
Wiring side
ADSL16i application pack This connector provides ISDN service and is used for the application
connector (16 ports) pack LPA417. The figure below shows the pin assignment of this
....................................................................................................................................................................................................................................
4-122 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
Other application packs
Short
Orange binder Blue binder
68 34
Ring BL/Y BL/Y Ring
R32 67 33 R16
ISDN port 16 Tip Y/BL Y/BL Tip ISDN port 8
T32 T16
S/BK S/BK
R31 R15
ADSL port 16 BK/S BK/S ADSL port 8
T31 T15
BR/BK BR/BK
R30 R14
ISDN port 15 BK/BR BK/BR ISDN port 7
T30 T14
G/BK G/BK
R29 R13
ADSL port 15 BK/G BK/G ADSL port 7
T29 T13
O/BK O/BK
R28 R12
ISDN port 14 BK/O BK/O ISDN port 6
T28 T12
BL/BK BL/BK
R27 R11
ADSL port 14 BK/BL BK/BL ADSL port 6
T27 T11
S/R S/R
R26 R10
ISDN port 13 R/S R/S ISDN port 5
T26 T10
BR/R BR/R Ring
R25 R9
ADSL port 13 R/BR R/BR Tip ADSL port 5
T25 T9
G/R G/R
R24 R8
ISDN port 12 R/G R/G ISDN port 4
T24 T8
O/R O/R
R23 R7
ADSL port 12 R/O R/O ADSL port 4
T23 T7
BL/R BL/R
R22 R6
ISDN port 11 R/BL R/BL ISDN port 3
T22 T6
S/W S/W
R21 R5
ADSL port 11 W/S W/S ADSL port 3
T21 T5
BR/W BR/W
R20 R4
ISDN port 10 W/BR W/BR ISDN port 2
T20 T4
G/W G/W
R19 R3
ADSL port 10 W/G W/G ADSL port 2
T19 T3
O/W O/W
R18 R2
ISDN port 9 W/O W/O ISDN port 1
T18 T2
Ring BL/W BL/W Ring
R17 R1
ADSL port 9 Tip W/BL W/BL Tip ADSL port 1
T17 36 2 T1
35 1
Wiring side
ADSL32p application pack This connector provides POTS service and is used for the application
connector (32 ports) pack LPA432. The figure below shows the pin assignment of this
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-123
Issue 1, July 2005 See notice on first page
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
Other application packs
Shot
Orange binder Blue binder
68 34
Ring BL/Y BL/Y Ring
R32 67 33 R16
ADSL port 32 Tip Y/BL Y/BL Tip ADSL port 16
T32 T16
S/BK S/BK
R31 R15
ADSL port 31 BK/S BK/S ADSL port 15
T31 T15
BR/BK BR/BK
R30 R14
ADSL port 30 BK/BR BK/BR ADSL port 14
T30 T14
G/BK G/BK
R29 R13
ADSL port 29 BK/G BK/G ADSL port 13
T29 T13
O/BK O/BK
R28 R12
ADSL port 28 BK/O BK/O ADSL port 12
T28 T12
BL/BK BL/BK
R27 R11
ADSL port 27 BK/BL BK/BL ADSL port 11
T27 T11
S/R S/R
R26 R10
ADSL port 26 R/S R/S ADSL port 10
T26 T10
BR/R BR/R
R25 R9
ADSL port 25 R/BR R/BR ADSL port 9
T25 T9
G/R G/R
R24 R8
ADSL port 24 R/G R/G ADSL port 8
T24 T8
O/R O/R
R23 R7
ADSL port 23 R/O R/O ADSL port 7
T23 T7
BL/R BL/R
R22 R6
ADSL port 22 R/BL R/BL ADSL port 6
T22 T6
S/W S/W
R21 R5
ADSL port 21 W/S W/S ADSL port 5
T21 T5
BR/W BR/W
R20 R4
ADSL port 20 W/BR W/BR ADSL port 4
T20 T4
G/W G/W
R19 R3
ADSL port 19 W/G W/G ADSL port 3
T19 T3
O/W O/W
R18 R2
ADSL port 18 W/O W/O ADSL port 2
T18 T2
Ring BL/W BL/W Ring
R17 R1
ADSL port 17 Tip W/BL W/BL Tip ADSL port 1
T17 36 2 T1
35 1
Wiring side
ADSL32i application pack This connector provides ISDN service and is used for the application
connector (32 ports) pack LPA434. The figure below shows the pin assignment of this
....................................................................................................................................................................................................................................
4-124 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
Other application packs
Shot
Orange binder Blue binder
68 34
Ring BL/Y BL/Y Ring
R32 67 33 R16
ISDN port 32 Tip Y/BL Y/BL Tip ISDN port 16
T32 T16
S/BK S/BK
R31 R15
ISDN port 31 BK/S BK/S ISDN port 15
T31 T15
BR/BK BR/BK
R30 R14
ISDN port 30 BK/BR BK/BR ISDN port 14
T30 T14
G/BK G/BK
R29 R13
ISDN port 29 BK/G BK/G ISDN port 13
T29 T13
O/BK O/BK
R28 R12
ISDN port 28 BK/O BK/O ISDN port 12
T28 T12
BL/BK BL/BK
R27 R11
ISDN port 27 BK/BL BK/BL ISDN port 11
T27 T11
S/R S/R
R26 R10
ISDN port 26 R/S R/S ISDN port 10
T26 T10
BR/R BR/R
R25 R9
ISDN port 25 R/BR R/BR ISDN port 9
T25 T9
G/R G/R
R24 R8
ISDN port 24 R/G R/G ISDN port 8
T24 T8
O/R O/R
R23 R7
ISDN port 23 R/O R/O ISDN port 7
T23 T7
BL/R BL/R
R22 R6
ISDN port 22 R/BL R/BL ISDN port 6
T22 T6
S/W S/W
R21 R5
ISDN port 21 W/S W/S ISDN port 5
T21 T5
BR/W BR/W
R20 R4
ISDN port 20 W/BR W/BR ISDN port 4
T20 T4
G/W G/W
R19 R3
ISDN port 19 W/G W/G ISDN port 3
T19 T3
O/W O/W
R18 R2
ISDN port 18 W/O W/O ISDN port 2
T18 T2
Ring BL/W BL/W Ring
R17 R1
ISDN port 17 Tip W/BL W/BL Tip ISDN port 1
T17 36 2 T1
35 1
Wiring side
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-125
Issue 1, July 2005 See notice on first page
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
Other application packs
SHDSL16 application pack This connector is used for the application pack LPS702. The figure
connector below shows the pin assignment of this connector. The orderable
cables are listed in Table 4-61, “Available a/b cables” (4-129).
Short
Orange binder Blue binder
68 34
Ring BL/Y BL/Y Ring
R32 67 33 R16
not used Tip Y/BL Y/BL Tip SHDSL8 copper pair
T32 T16 for HDSL port 16
S/BK S/BK
R31 R15 SHDSL7 copper pair
not used BK/S BK/S
T31 T15 for SHDSL port 15
BR/BK BR/BK
R30 R14 SHDSL6 copper pair
not used BK/BR BK/BR
T30 T14 for SHDSL port 14
G/BK G/BK
R29 R13
not used BK/G BK/G SHDSL5 copper pair
T29 T13 for SHDSL port 13
O/BK O/BK
R28 R12 SHDSL4 copper pair
not used BK/O BK/O
T28 T12 for SHDSL port 12
BL/BK BL/BK
R27 R11 SHDSL3 copper pair
not used BK/BL BK/BL
T27 T11 for HDSL port 11
S/R S/R
R26 R10 SHDSL2 copper pair
not used R/S R/S
T26 T10 for SHDSL port 10
BR/R BR/R
R25 R9 SHDSL1 copper pair
not used R/BR R/BR
T25 T9 for SHDSL port 9
G/R G/R
R24 R8
not used R/G SHDSL8 copper pair
R/G
T24 T8 for SHDSL port 8
O/R O/R
R23 R7 SHDSL7 copper pair
not used R/O R/O
T23 T7 for SHDSL port 7
BL/R BL/R
R22 R6
not used R/BL R/BL SHDSL6 copper pair
T22 T6 for SHDSL port 6
S/W S/W
R21 R5
not used W/S W/S SHDSL5 copper pair
T21 T5 for SHDSL port 5
BR/W BR/W
R20 R4 SHDSL4 copper pair
not used W/BR W/BR
T20 T4 for SHDSL port 4
G/W G/W
R19 R3 SHDSL3 copper pair
not used W/G W/G
T19 T3 for SHDSL port 3
O/W O/W
R18 R2 SHDSL2 copper pair
not used W/O W/O
T18 T2 for SHDSL port 2
Ring BL/W BL/W Ring
R17 R1 SHDSL1 copper pair
not used Tip W/BL W/BL Tip
T17 T1 for SHDSL port 1
36 2
35 1
For the SHDSL16 AP only 16 SHDSL ports Short The top pair (34 & 68)
with 1 copper pair each are used supporting and bottom pair (1 & 35)
up to 2.3 Mbit/s brutto with 16 PAM line are each shorted to alert the
coding. circuit pack that the connector
is attached
Wiring side
....................................................................................................................................................................................................................................
4-126 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
Other application packs
HDSL application pack This connector is used for the application pack LPS504. The figure
connector below shows the pin assignment of this connector. The orderable
cables are listed in Table 4-61, “Available a/b cables” (4-129).
Short
Orange binder Blue binder
68 34
Ring BL/Y BL/Y Ring
R32 67 33 R16
not used Tip Y/BL Y/BL Tip not used
T32 T16
S/BK S/BK
R31 R15
not used BK/S BK/S not used
T31 T15
BR/BK BR/BK
R30 R14
not used BK/BR BK/BR not used
T30 T14
G/BK G/BK
R29 R13
not used BK/G BK/G not used
T29 T13
O/BK O/BK
R28 R12
not used BK/O BK/O not used
T28 T12
BL/BK BL/BK
R27 R11
not used BK/BL BK/BL not used
T27 T11
S/R S/R
R26 R10
not used R/S R/S not used
T26 T10
BR/R BR/R
R25 R9
not used R/BR R/BR not used
T25 T9
G/R G/R
R24 R8
not used R/G R/G not used
T24 T8
O/R O/R
R23 R7 HDSL3 copper pair
not used R/O R/O
T23 T7 for HDSL port 4
BL/R BL/R
R22 R6
not used R/BL R/BL not used
T22 T6
S/W S/W
R21 R5 HDSL2 copper pair
not used W/S W/S
T21 for HDSL port 3
T5
BR/W BR/W
R20 R4
not used W/BR W/BR not used
T20 T4
G/W G/W
R19 R3 HDSL1 copper pair
not used W/G W/G
T19 T3 for HDSL port 2
O/W O/W
R18 R2
not used W/O W/O not used
T18 T2
Ring BL/W BL/W Ring
R17 R1 HDSL0 copper pair
not used Tip W/BL W/BL Tip
T17 T1 for HDSL port 1
36 2
35 1
For the HDSL AP only 4 HDSL copper The top pair (34 & 68)
pairs are used. Each of them have a transport Short and bottom pair (1 & 35)
rate of 1168 kbit/s. Two copper pairs can be are each shorted to alert the
used in parallel for a bit rate of 2336 kbit/s circuit pack that the connector
(HDSL0/HDSL1 pair or HDSL2/HDSL3 pair) is attached
Wiring side
P32A32 application pack This connector provides ADSL and POTS service and is used for the
connector application packs LPA832 and LPA833. The figure below shows the
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-127
Issue 1, July 2005 See notice on first page
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
Other application packs
Shot
Orange binder Blue binder
68 34
Ring BL/Y BL/Y Ring
R32 67 33 R16
ADSL/POTS port 32 Tip Y/BL Y/BL Tip ADSL/POTS port 16
T32 T16
S/BK S/BK
R31 R15
ADSL/POTS port 31 BK/S BK/S ADSL/POTS port 15
T31 T15
BR/BK BR/BK
R30 R14
ADSL/POTS port 30 BK/BR BK/BR ADSL/POTS port 14
T30 T14
G/BK G/BK
R29 R13
ADSL/POTS port 29 BK/G BK/G ADSL/POTS port 13
T29 T13
O/BK O/BK
R28 R12
ADSL/POTS port 28 BK/O BK/O ADSL/POTS port 12
T28 T12
BL/BK BL/BK
R27 R11
ADSL/POTS port 27 BK/BL BK/BL ADSL/POTS port 11
T27 T11
S/R S/R
R26 R10
ADSL/POTS port 26 R/S R/S ADSL/POTS port 10
T26 T10
BR/R BR/R
R25 R9
ADSL/POTS port 25 R/BR R/BR ADSL/POTS port 9
T25 T9
G/R G/R
R24 R8
ADSL/POTS port 24 R/G R/G ADSL/POTS port 8
T24 T8
O/R O/R
R23 R7
ADSL/POTS port 23 R/O R/O ADSL/POTS port 7
T23 T7
BL/R BL/R
R22 R6
ADSL/POTS port 22 R/BL R/BL ADSL/POTS port 6
T22 T6
S/W S/W
R21 R5
ADSL/POTS port 21 W/S W/S ADSL/POTS port 5
T21 T5
BR/W BR/W
R20 R4
ADSL/POTS port 20 W/BR W/BR ADSL/POTS port 4
T20 T4
G/W G/W
R19 R3
ADSL/POTS port 19 W/G W/G ADSL/POTS port 3
T19 T3
O/W O/W
R18 R2
ADSL/POTS port 18 W/O W/O ADSL/POTS port 2
T18 T2
Ring BL/W BL/W Ring
R17 R1
ADSL/POTS port 17 Tip W/BL W/BL Tip ADSL/POTS port 1
T17 36 2 T1
35 1
Wiring side
....................................................................................................................................................................................................................................
4-128 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Circuit pack and application pack Parts descriptions of connector fields connectors and
connectors internal cables
Other application packs
Cables available for order The table below shows the a/b cable types. For the different lengths
refer to the Ordering Guide (363-211-144).
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-129
Issue 1, July 2005 See notice on first page
Parts descriptions of connector fields connectors and
internal cables
Internal cabling
Overview
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
4-130 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Internal cabling Parts descriptions of connector fields connectors and
internal cables
Connection points in the This figure shows the RFCP with all internal pre-installed connections
RFCP to the shelves/fans. The number added (e.g. C316) enables the user to
find in the table below both destinations and the cable type used for
this unique connection.
C036
C110
C210
C310
C336
C236
C136
Gr20
C112 C212 C312
C113 C213 C313
Connections within the This table specifies all pre-installed internal connections in the rack,
rack describing both destinations and the cable specification for the cable
type used.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-131
Issue 1, July 2005 See notice on first page
Internal cabling Parts descriptions of connector fields connectors and
Internal connections for J1C293B-1 internal cables
....................................................................................................................................................................................................................................
4-132 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Internal cabling Parts descriptions of connector fields connectors and
internal cables
Connection points in the This figure shows the RCP with all internal connections (pre-installed
RCP and optional connections) to the shelves/fans. The number added (e.g.
C111) enables the user to find in the table below both destinations and
the cable type used for this unique connection.
Connections within the This table specifies all internal connections in the rack (pre-installed
rack and optional), describing both destinations and the cable specification
for the cable type used.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 4-133
Issue 1, July 2005 See notice on first page
Internal cabling Parts descriptions of connector fields connectors and
Internal connections for J1C301B-1 internal cables
Notes:
1. Pre-installed at delivery.
....................................................................................................................................................................................................................................
4-134 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
5 Cabling procedures
Overview
....................................................................................................................................................................................................................................
Contents
External Cables 5-4
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-1
Issue 1, July 2005 See notice on first page
Overview Cabling procedures
....................................................................................................................................................................................................................................
5-2 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Overview Cabling procedures
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-3
Issue 1, July 2005 See notice on first page
Cabling procedures
External Cables
....................................................................................................................................................................................................................................
Overview The external cables may be prefabricated (equipped with at least one
connector) or the cables may have to be assembled completely on site
by the installer/customer. The external prefabricated cables must be
ordered separately. For details refer to the Ordering Guide
(363-211-144).
External cables - Prefabricated cables are used to interconnect the AnyMedia Shelves to
Prefabricated cables ancillary equipment such as the following:
• a/b-cabling (e.g. POTS lines, ADSL lines, ISDN lines) for
connections from the application packs (APs) to the main
distribution frame (MDF)
• TAP test pair connections from the test application pack (TAP) to
the MDF or to the customer’s remote test unit for subscriber
testing facilities
• E1 and E3/DS3 line connections from the shelf connectors to the
digital distribution frame (DDF)
• 10BaseT connections for connecting from the shelves to the LAN
via the customer’s mini- hub or other LAN equipment
• Feeder cabling from the AFM application pack to the digital
distribution frame (DDF) or to/from the next/previous BB
subsystem in the daisy chain, if required
• Fiber cabling from the AFMO application pack to the optical
distribution frame or to/from the next/previous BB subsystem in
the daisy chain, if required
• Cabling for the FE uplink feeders and/or the GbE uplink feeders
from the IPFM(s) to the IP network
• Fiber cabling from the optical application packs (OAPs) to the
ONU Subshelves
• DC power connections from the rack to the external −48 V
power feeders
• Ringing connections from the customer’s ringing supplies via the
ringing filter units (RFUs) if applicable.
The standard wire color coding for the prefabricated cables is shown
in “Color-Coding for cables” (A-3).
Customized cables Customer-made cables are cables that must be engineered and
fabricated in the field. They are used to connect the AnyMedia ®
....................................................................................................................................................................................................................................
5-4 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
External Cables Cabling procedures
Cable routing If not stated otherwise in the cabling procedures, the following routing
order must be observed during CP and AP cable installation:
1. All cables must be routed from the AP faceplate connectors to
the bottom of the AnyMedia ® Shelf vertically. Make sure that the
cables are led through the cut-outs located at the shelf bottom
and fixed with cable ties.
2. All fiber cables should be routed to the right cut-out of the shelf
and then through the optical cable duct.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-5
Issue 1, July 2005 See notice on first page
External Cables Cabling procedures
....................................................................................................................................................................................................................................
5-6 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Cabling procedures
High level overview This section describes the customer cabling that must be performed
on-site once the rack and the shelves have been mounted and
grounded and it provides a recommended order for the cabling.
The cabling procedures depend on the configuration of the
AnyMedia ® Access System.
As described in detail in the following sections the cabling should be
done in the following recommended order.
Procedure Skip procedures that are not applicable because they do not apply
to the current configuration.
............................................................................................................................................................
4 Install the a/b-cables for the application packs of the installed shelves
and attach ferrite kits if applicable. One of the a/b-cables can be used
per Shelf as TAP10x (TAP10x is a placeholder for TAP100B or
TAP101) cable for the TAP10x application pack.
............................................................................................................................................................
8 Install fiber cables for OAP packs for the connection of ONU
Subshelves.
............................................................................................................................................................
9 Install the LAN cables to the connector fields of the shelves and
connect to the customer’s 10BaseT LAN equipment.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-7
Issue 1, July 2005 See notice on first page
Recommended range of order for cabling Cabling procedures
............................................................................................................................................................
13 Connect all a/b-cables to the MDF (used for POTS, ISDN, and xDSL)
and verify the MDF cabling. Note that the MDF and all subscriber
cabling leaving the building should be protected by protector blocks
(primary protection).
............................................................................................................................................................
....................................................................................................................................................................................................................................
5-8 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Cabling procedures
Purpose This section describes the cabling procedures for the AFME3/DS3
packs using coaxial cables. For the duplex mode also
splitters/combiners with three BNC-type connectors have to be used.
The connections can be made:
• In simplex AFM mode without daisy-chaining as described in
“Installing E3/DS3 feeder cables for simplex mode without
daisy-chaining” (5-12)
• In simplex AFM mode with daisy-chaining as described in
“Installing E3/DS3 feeder cables for simplex mode with
daisy-chaining” (5-15)
• In duplex AFM mode without daisy-chaining as described in
“Installing E3/DS3 feeder cables for duplex mode without
daisy-chaining” (5-19)
• In duplex AFM mode with daisy-chaining as described in
“Installing E3/DS3 feeder cables for duplex mode with
daisy-chaining” (5-24).
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-9
Issue 1, July 2005 See notice on first page
Installing E3/DS3 cables for Cabling procedures
AFME3/AFMDS3 packs - Overview
Cables
Table 5-1 Orderable external cables and splitters/combiners
for E3/DS3 cabling
Cable description Equipment Code Used for
E3/DS3 75 735A ED7C829-32 G3x3 For E3/DS3 feeders
cable, 90deg/straight towards the ATM
BNC network
E3/DS3 75 734A ED7C829-32 G4
cable, 90deg/straight
BNC
E3/DS3 75 735A ED7C829-32 G30x 3
cable,
straight/straight BNC
E3/DS3 75 734A ED7C829-32 G40
cable,straight/straight
BNC
E3/DS3 75 735A ED7C829-31 G1x3 Used for E3/DS3
cable, 90deg/90deg daisychaining in
BNC duplex mode for
interconnecting the
splitters (2 per
daisychained row) 1
E3/DS3 75 735A ED7C829-31 G1D Used for E3/DS3
cable, 90deg/90deg daisychaining (2 per
BNC splitter/ combiner) 2
Splitter/Combiner 406333849 For duplex AFM
ZFSC-2-1-75 mode
Notes:
1. The cables are connected to the S-ports of the splitters.
2. The cables are used for connecting the splitters to the AFM ports
3. For the different lengths refer to the Ordering Guide (363-211-144).
....................................................................................................................................................................................................................................
5-10 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing E3/DS3 cables for Cabling procedures
AFME3/AFMDS3 packs - Overview
Shielding The coax cables have to be grounded close to the AFM ports by
attaching grounding clips. The grounding clips create electrical
connection between cable shield and shelf framework.
Cable labelling The cable ends should be labelled during installation with the
designations which the cable ends have to be connected to.
Duplex AFM mode In duplex AFM mode two AFMs are installed per BB subsystem.
Splitters/combiners with three BNC-type connectors have to be used.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-11
Issue 1, July 2005 See notice on first page
Cabling procedures
1 Verify that no a/b cable is installed to the blank faceplate of the slot
position where the AFM will be installed.
Otherwise disconnect this a/b cable from the faceplate, cut the cable
tie on the guiding finger and place the cable in the cable trough above
the already installed a/b-cables. If the work order specifies remove
this a/b cable completely.
............................................................................................................................................................
3 Mark one cable end with TX-1 the other end with E3/DS3_TX. Mark
the other cable with RX-1 and E3/DS3_RX accordingly.
............................................................................................................................................................
4 Install the two cables with the TX-1/RX-1 labeled BNC connectors
from the top of the rack.
Route E3/DS3 feeder cables:
• To the LAG 1900 Shelves in the left cable duct
• To the ETSI V5 Shelves in the right cable duct of the rack.
Pull the BNC ends through the opening of the shelves so that the
BNC ends reach the RX-1/TX-1 connectors of the AFM. If the AFM
is not equipped the cable ends should reach the middle of the AFM
slot position. The free ends on top of the rack will be connected later.
....................................................................................................................................................................................................................................
5-12 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing E3/DS3 feeder cables for simplex Cabling procedures
mode without daisy-chaining
............................................................................................................................................................
5 Attach grounding clips to the cable ends RX-1 and TX-1 close to the
AFM ports. The grounding clips create electrical connection between
cable shield and shelf framework.
............................................................................................................................................................
6 If then
the AFM is not installed already place the two cables in the cable
trough for later installation. Do
not remove the blank faceplate.
the AFM is installed already connect the TX-1 cable end to
the TX-1 faceplate connector of
the AFM, connect the RX-1
cable connector to the RX-1
faceplate connector.
............................................................................................................................................................
7 Fix the cables in the cable duct area with cable ties as required.
............................................................................................................................................................
8 Locate the free cable ends on top of the rack and route the other cable
ends to the E3/DS3 distribution panel:
1. Connect the RX-ends to the TX (Transmit, output) of the E3/DS3
distribution panel.
2. Connect E3/DS3 _TX connector to the TX connector (OUT) and
the E3/DS3_RX to the RX (IN) connector of the E3/DS3
distribution panel.
E ND OF STEPS
............................................................................................................................................................
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-13
Issue 1, July 2005 See notice on first page
Installing E3/DS3 feeder cables for simplex Cabling procedures
mode without daisy-chaining
Comment:
Often the receive and the transmit ports of the E3/DS3 distribution
panel are cross-connected internally. Therefore for example TX-1
cable is connected to TX (out) here.
TX-1 OUT IN RX
TX
Transmit
Receive
RX-1 IN OUT TX
RX
Receive Transmit
....................................................................................................................................................................................................................................
5-14 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Cabling procedures
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-15
Issue 1, July 2005 See notice on first page
Installing E3/DS3 feeder cables for simplex Cabling procedures
mode with daisy-chaining
Principle The figure below shows the cabling principle for simplex
daisy-chaining.
Simplex E3/DS3 cabling Start this procedure with the first AFM in the daisy-chain:
with daisychaining
............................................................................................................................................................
1 If then
the current AFM is the first AFM follow “Installing E3/DS3 feeder
in the daisy-chain cables for simplex mode without
daisy-chaining” (5-12) to make
the connections to the
TX-1/RX-1 connectors.
Then repeat Step 1.
....................................................................................................................................................................................................................................
5-16 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing E3/DS3 feeder cables for simplex Cabling procedures
mode with daisy-chaining
............................................................................................................................................................
2 If then
the AFM has to be daisy-chained two coax cables (ED7C829-31
on ports RX-2/TX-2, G1D) as described in “Cables”
(5-10) are required with the
appropriate length to reach the
next shelf in the daisy-chain.
............................................................................................................................................................
3 Mark for the first cable one BNC connector (the right angled, if
applicable) with RX-2 and the other connector with TX-1. Mark the
second cable with TX-2 and RX-1 accordingly.
............................................................................................................................................................
4 Route the two cables with the RX-2/TX-2 connectors from the cable
duct through the shelf opening where the current AFM is located. The
cable ends should reach about the middle of the relevant slot.
............................................................................................................................................................
5 Attach grounding clips to the cable ends RX-2 and TX-2 close to the
AFM ports. The grounding clips create electrical connection between
cable shield and shelf framework.
............................................................................................................................................................
6 If the AFM is not equipped place the two cables in the cable trough
for later installation. Do not remove the blank faceplate.
............................................................................................................................................................
7 If the AFM is installed already connect the TX-2 cable end to the
TX-2 faceplate connector of the AFM, connect the RX-2 cable
connector to the RX-2 faceplate connector.
............................................................................................................................................................
8 Obtain the other two free cable ends (labeled TX-1 and RX-1) from
the cable duct and route them to the opening of the shelf where the
next AFM in the daisy-chain is located.
............................................................................................................................................................
9 Verify that no a/b cable is installed to the blank faceplate of the AFM
slot. Otherwise disconnect this a/b cable from the faceplate, cut the
cable tie on the guiding finger and place the cable in the cable trough.
If the work order specifies remove this a/b cable completely.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-17
Issue 1, July 2005 See notice on first page
Installing E3/DS3 feeder cables for simplex Cabling procedures
mode with daisy-chaining
............................................................................................................................................................
10 Feed the two cable ends with their RX-1/TX-1 connectors through the
shelf opening so that the connectors reach the RX-1/TX-1 connectors
of the AFM.
............................................................................................................................................................
11 Attach grounding clips to the cable ends RX-1 and TX-1 close to the
AFM ports. The grounding clips create electrical connection between
cable shield and shelf framework.
............................................................................................................................................................
12 If then
the AFM is not installed already, place the two cables in the cable
trough for later installation. Do
not remove the blank faceplate.
the AFM is installed already, connect the TX-1 cable end to
the TX-1 faceplate connector of
the AFM, connect the RX-1
cable connector to the RX-1
faceplate connector.
............................................................................................................................................................
....................................................................................................................................................................................................................................
5-18 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Cabling procedures
TX-1
1
TX-1
TX-1 TX1 S
AFM1 2
TX-1 ATM Network
TX-1
RX-1 RX-1 RX-1
TX-2 TX-2 1
RX-1
RX-2 RX-2 RX-1 RX1 S
2
AFM2
TX-1 ED7C829-31 G1D cables
TX-1
RX-1 RX-1 (90°/90°)
TX-2
TX-2
RX-2 RX-2
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-19
Issue 1, July 2005 See notice on first page
Installing E3/DS3 feeder cables for duplex Cabling procedures
mode without daisy-chaining
1 Mark the 90° BNC connector of one cable ED7C829-32 Gxx with
TX-1, mark the other side with E3/DS3_TX. Mark the other cable
with RX-1 and E3/DS3_RX accordingly.
............................................................................................................................................................
2 Install the two cables with the RX-1/TX-1 BNC connectors from the
top of the rack in the cable duct on the left side for LAG 1900
Shelves, respectively on the right side for ETSI V5 Shelves.
............................................................................................................................................................
3 Pull the BNC ends through the left opening in the shelf to the bottom
of the row where the BB subsystem will be placed. Place the two
cable ends in the cable trough, available for later connection to the
splitters.
............................................................................................................................................................
6 Mark two ED7C829-31 G1D cables with TX-1 on both ends, mark
the other two ED7C829-31 G1D cables with RX-1 accordingly.
RX1
TX1
TX1
S S
RX1 1 2 RX1 TX1 1 2 TX1
Splitter/Combiner Splitter/Combiner
RX1 TX1
............................................................................................................................................................
7 Connect the RX-1 ends to the 1-port and to the 2-port of the RX-1
splitter, connect the TX-1 ends to the 1-port and to the 2-port of the
TX-1 splitter.
............................................................................................................................................................
....................................................................................................................................................................................................................................
5-20 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing E3/DS3 feeder cables for duplex Cabling procedures
mode without daisy-chaining
............................................................................................................................................................
RX
TX
RX1
RX1
TX1
TX1
RX1
TX1
S S
............................................................................................................................................................
............................................................................................................................................................
11 Attach grounding clips to the cable ends RX-1 and TX-1 close to the
AFM ports.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-21
Issue 1, July 2005 See notice on first page
Installing E3/DS3 feeder cables for duplex Cabling procedures
mode without daisy-chaining
............................................................................................................................................................
12 If then
the AFMs are not installed sort the cable ends of the four
already ED7C829-31 G1D cables to the
guiding fingers and fix them
temporarily in order to make
sure that they will not be hidden
during a/b cabling. Do not
remove the blank faceplates.
the AFMs are already installed connect one RX-1 end to the
RX-1 faceplate connector and
one TX-1 end to the TX-1
faceplate connector of the
preferred AFM and sort these
two cables to the guiding finger
below. Connect the other RX-1
and TX-1 end to the appropriate
RX-1 and TX-1 faceplate
connector of the AFM in the
AFM protection slot and sort the
cables to the guiding fingers
below.
............................................................................................................................................................
13 Locate the free cable ends on top of the rack and route them to the
E3/DS3 distribution panel.
............................................................................................................................................................
....................................................................................................................................................................................................................................
5-22 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing E3/DS3 feeder cables for duplex Cabling procedures
mode without daisy-chaining
Comment:
Often the receive and the transmit ports of the E3/DS3 distribution
panel are cross-connected internally. Therefore for example the TX-1
cable is connected to TX (OUT) here:
AFM AFM
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-23
Issue 1, July 2005 See notice on first page
Cabling procedures
Purpose Use this procedure to install E3/DS3 feeder cables for daisy-chained
BB subsystems in duplex AFM mode. Splitters/combiners are
required.
For daisy chaining the TX2/RX2 connectors of the previous
AFME3/DS3 packs in the daisy-chain must be connected via the
splitters/combiners to the RX1/TX1 connectors of the next
AFME3/DS3 packs in the chain.
If the AFMs are already installed, the procedure describes how to
connect them. If the AFMs are not yet installed, the procedure
describes how to install the cables. In this case the connection to the
AFMs will be done during turn-up of the system.
Equipment The following equipment is required in total (for the list of cables
refer to “Cables” (5-10)):
• Two coaxial cables towards the ATM network; select one type of
ED7C829- 32 Gxx
• Twelve coaxial cables ED7C829-31 G1D (90°/90°)
• Two coaxial cables ED7C829-31 G1 (90°/90°)
• Six splitters/combiners ZFSC-2-1-75
• Grounding clips for the cable connections to the AFM ports.
....................................................................................................................................................................................................................................
5-24 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing E3/DS3 feeder cables for duplex Cabling procedures
mode with daisy-chaining
AFM pack*
AFM pack*
ED7C829-32 G3x, 40 cables
(straight/straight)
TX-1 TX-1
To/from ATM TX-1 splitter
network RX-1 RX-1
RX-1 splitter
TX-2 TX-2
TX-2 splitter
RX-2 RX-2
1
Splitter/Combiner
RX-2 splitter
ZFSC-2-1-75
S
2
AFM pack*
AFM pack*
TX-1 TX-1
TX-1 splitter
RX-1 RX-1
RX-1 splitter
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-25
Issue 1, July 2005 See notice on first page
Installing E3/DS3 feeder cables for duplex Cabling procedures
mode with daisy-chaining
TX-1
1
TX-1
TX-1 TX1 S
AFM1 2
TX-1
TX-1 ATM Network
RX-1
RX-1 RX-1
TX-2
TX-2 1
RX-1
RX-2 RX-2
RX-1 RX1 S
2
AFM2
TX-1
TX-1 TX-2
RX-1 1
RX-1 TX-2
TX-2
TX-2
TX-2 TX2 S
RX-2 2
RX-2
RX-2
1
RX-2
RX-2 RX2 S
2
AFM1
TX-1
TX-1 TX-1
1
ED7C829-37 G1 cables
RX-1 TX-1 (90°/90°)
RX-1 TX-1 TX1 S
TX-2 2
RX-2
RX-1
1
AFM2 RX-1
RX-1 RX1 S
TX-1 2
TX-1
RX-1
RX-1
TX-2
RX-2
ED7C829-31 D1D cables
(90°/90°)
Procedure Start this procedure with the first AFM pair in the daisy-chain:
............................................................................................................................................................
1 If the current AFM pair is the first AFM pair in the daisy-chain, then
follow “Installing E3/DS3 feeder cables for duplex mode without
daisy-chaining” (5-19) to make the connections to the TX-1/RX-1
connectors.
Then go to Step 2.
....................................................................................................................................................................................................................................
5-26 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing E3/DS3 feeder cables for duplex Cabling procedures
mode with daisy-chaining
............................................................................................................................................................
4 Mark two ED7C829-31 G1D cables with TX-2 on both ends close to
the connector, mark the other two ED7C829-31 G1D cables with
RX-2 accordingly.
RX2
TX2
TX1
S S
RX2 1 2 RX1 TX2 1 2 TX2
Splitter/Combiner Splitter/Combiner
RX2 TX2
............................................................................................................................................................
5 Connect the RX-2 cable ends to the 1-port and to the 2-port of the
RX-2 splitter, connect the TX-2 ends to the 1-port and to the 2-port of
the TX-2 splitter.
............................................................................................................................................................
7 Attach grounding clips to the cable ends RX-2 and TX-2 close to the
AFM ports.
............................................................................................................................................................
8 If then
the AFMs are not installed sort the cable ends of the two
already ED7C829-31 G1D cables to the
guiding fingers and fix them
temporarily in order to make
sure that they will not be hidden
during a/b cabling. Do not
remove the blank faceplates.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-27
Issue 1, July 2005 See notice on first page
Installing E3/DS3 feeder cables for duplex Cabling procedures
mode with daisy-chaining
If then
the AFMs are already installed connect one RX-2 end and one
TX-2 end to each of both AFMs
in this row. Sort the cables to the
guiding fingers below.
............................................................................................................................................................
10 Mark for the first cable one connector with RX-2 and the other
connector with TX-1. Mark the second cable with TX-2 and RX-1
accordingly.
RX1
TX1
RX2
TX2
TX2
RX2
TX2
S S
............................................................................................................................................................
....................................................................................................................................................................................................................................
5-28 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing E3/DS3 feeder cables for duplex Cabling procedures
mode with daisy-chaining
Splitters / combiners
............................................................................................................................................................
13 Locate the RX-1 and TX-1 ends from the cables and route them
through the left shelf opening towards the row with the next AFM
pair in the daisy-chain.
............................................................................................................................................................
14 Route the two cables with the RX-1/TX-1 connectors in the left cable
duct to this row. Pull the cables through the left shelf opening of this
row. Place the two cables in the cable trough, available for later
connection.
............................................................................................................................................................
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-29
Issue 1, July 2005 See notice on first page
Installing E3/DS3 feeder cables for duplex Cabling procedures
mode with daisy-chaining
............................................................................................................................................................
17 Mark two ED7C829-31 G1D cables with TX-1 on both ends, mark
the other two ED7C829-31 G1D cables with RX-1 accordingly.
RX1
RX1
TX1
TX1
S S
RX1 1 2 RX1 TX1 1 2 TX1
Splitter/Combiner Splitter/Combiner
RX1 TX1
............................................................................................................................................................
18 Connect the RX-1 ends to the 1-port and to the 2-port of the RX-1
splitter, connect the TX-1 ends to the 1-port and to the 2-port of the
TX-2 splitter.
............................................................................................................................................................
19 Locate in the cable trough the two coaxial cables from the previous
row in the daisy chain with the RX-1 and TX-1 ends.
............................................................................................................................................................
RX1
TX1
TX1
RX1
TX1
S S
............................................................................................................................................................
....................................................................................................................................................................................................................................
5-30 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing E3/DS3 feeder cables for duplex Cabling procedures
mode with daisy-chaining
............................................................................................................................................................
22 Attach grounding clips to the cable ends RX-1 and TX-1 close to the
AFM ports. The grounding clips create electrical connection between
cable shield and shelf framework.
............................................................................................................................................................
23 If then
the AFMs are not installed sort the cable ends of the four
already ED7C829-31 G1D cables to the
guiding fingers and fix them
temporarily in order to make
sure that they will not be hidden
during a/b cabling. Do not
remove the blank faceplates.
the AFMs are already installed connect one RX-1 end and one
TX-1 end to each of both AFMs
in this row. Sort the cables to the
guiding fingers below.
............................................................................................................................................................
24 Repeat this procedure for the next AFM pair in the daisy-chain.
END OF STEPS
..............................................................................................................................................................................
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-31
Issue 1, July 2005 See notice on first page
Cabling procedures
Purpose This section describes the cabling procedure for the AFME1 packs
using a special AFME1 Y-cable with 16 pairs to which two 8-pair
cables with open end are connected.
Connectors For connecting the Y-cable to the AFME1 the faceplate is equipped
with a female 37-pin D-sub connector. One end of the Y-cable is
equipped with a male 37-pin D-sub connector, the other ends are
equipped with a female 25-pin D-sub connector each.
The 8-pair cables ED7C849-30 G11x are equipped with a male 25-pin
D-sub connector on the side which connects to the 25-pin female
D-sub connector of the AFME1 Y-cable ED7C849-30 G10. The other
end is of open end for connecting to the E1 cross-connect.
Notes:
1. For the different lenghts refer to the Ordering Guide (363-211-144).
2. The cross-section of the Group 11 to Group 11C cable is 26 AWG (≈
0.4 mm diameter), the cross-section of the Group 11D cable is 22
AWG (≈ 0.6 mm diameter).
....................................................................................................................................................................................................................................
5-32 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing the E1 cables to the AFME1 - Cabling procedures
Overview
Lucent
FAULT
ACTV
CR-MJ
MN
CLF
CONSOLE
10BASE-T
Cable area w.
exposed braided
shield
E1 (Tx)
Tx ED7C849-30-G11x for Transmit pairs
1
J1 P1/Tx
E1
Rx
1 ED7C849-30-G10
Y-cable
J3 E1 (Rx)
ED7C849-30-G11x for Receive pairs
1
J2 P2/Rx
AFME1
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-33
Issue 1, July 2005 See notice on first page
Installing the E1 cables to the AFME1 - Cabling procedures
Overview
The pinning of both cable types and the color coding sequence:
m f J5
35
4K
m f m
to to
3_ 35
44 58 4K
_ NC 3Y
43 NC
G-R 57 to to
R-G Y E1 port 8, Down RxRing8 Y_BL 38
RxTip8 BL-Y 5K 44
37 BK-S TxTip8 _
O-R 4G 56 S-BK TxRing8 43 G-R
R-O 8 E1 port 7, Down RxRing7 BK-BR 3K E1 port 8, Up Y R-G
RxTip7 BR-BK 55
36 BK-G TxTip7
BL-R 3_ 54 G_BK TxRing7 4G O-R
R-BL 7 E1 port 6, Down RxRing6 BK-O 35 E1 port 7, Up 8 R-O
RxTip6 O-BK 53
34 BK-BL TxTip6
S-W 3Y 5G BL-BK TxRing6 3_ BL-R
W-S K E1 port 5, Down RxRing5 R-S 33 E1 port 6, Up 7 R-BL
RxTip5 S-R 4_
3G R-BR TxTip5
BR-W 38 4Y BR-R TxRing5 3Y S-W
W-BR 6 E1 port 4, Down RxRing4 R-G _ E1 port 5, Up K W-S
RxTip4 G-R 48
Y R-O TxTip4
G-W 37 47 O-R TxRing4 38 BR-W
W-G 5 E1 port 3, Down RxRing3 R-BL 8 E1 port 4, Up 6 W-BR
RxTip3 BL-R 4K
7 W-S TxTip3
O-W 3K 46 S-W TxRing3 37 G-W
W-O 4 E1 port 2, Down RxRing2 W-BR 5 E1 port 3, Up 5 W-G
RxTip2 BR-W 23
4 W-G TxTip2
BL-W 36 22 G-W TxRing2 3K O-W
W-BL 3 E1 port 1, Down RxRing1 W-O 3 E1 port 2, Up 4 W-O
RxTip1 O-W 21
2 W-BL TxTip1
20 BL-W TxRing1 36 BL-W
1 E1 port 1, Up 3 W-BL
NC
8-pair E1 cable with 16-pair AFME1 Y-cable with male 37- pin D-sub 8-pair E1 cable with
male 25- pin D- sub and two female 25- pin D-sub connectors male 25- pin D-sub
and open end to DDF (ED7C849-30 G10) and open end to DDF
(ED7C849-30 G11x) (ED7C849-30 G11x)
Note: RxTip1" stands for: Rx = Downstream (from CO to subscriber) Downstream means: Receive, towards the subscriber
Tip = Tip-wire (a-wire) Upstream means: Transmit, towards the service node (SN)
1 = E1 port 1 for Up- and Downstream
....................................................................................................................................................................................................................................
5-34 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Cabling procedures
Equipment The following equipment is required per AFME1 for the connection
towards the ATM network:
• One Y-cable ED7C849-30 G10
• Two 8-pair E1 cables (ED7C849-30 G11x)
• Grounding clips.
1 Verify that no a/b cable is installed to the blank faceplate of the slot
position where the AFM will be installed.
Otherwise disconnect this a/b cable from the faceplate, cut the cable
tie on the guiding finger and place the cable in the cable trough above
the already installed a/b-cables. If the work order specifies remove
this a/b cable completely.
............................................................................................................................................................
3 Install the two 8-pair E1 cables with their male 25-pin D-sub
connectors from top of the rack in the cable duct to the shelf where
the AFME1 is located.
• Use the left cable duct if the AFME1 will be installed in a LAG
1900 Shelf
• Use the right cable duct if the AFME1 will be installed in a ETSI
V5 Shelf.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-35
Issue 1, July 2005 See notice on first page
Installing the E1 cables from the AFME1 to Cabling procedures
the E1 cross-connect
Pull the cable ends with the connectors through the shelf opening. The
free ends on top of the rack will be connected later.
Important! If the free space in the cable duct does not allow the
insertion of the cable with the connectors from top of the rack,
these two cables must be installed reverse with their open end
starting at the shelf opening and must be pulled-up with a pulling
wire to the top of the rack. This means, of course, the entire
cable will have to be pulled up trough the cable duct.
............................................................................................................................................................
4 If then
the AFME1 Y-cable ED7C849-30 place the two 8-pair E1 cables
G10 is not available secured in the cabling area for
later connection. Go to Step 10.
the AFME1 Y-cable ED7C849-30 verify that the UNC 4-40 nuts on
G10 is available connector hoods of the two
25-pin connectors are tight. If
required tighten the four nuts.
Otherwise it could be difficult to
loose the screws if the
connectors have to be
disconnected later.
............................................................................................................................................................
6 If then
the AFME1 is not installed place the AFME1 Y-cable
secured in the cabling trough for
later connection. Do not remove
the blank faceplate. Go to Step
10.
the AFME1 is installed place the AFME1 Y-cable so that
the 37-pin Dsub connector J3
reaches the middle of the
AFME1.
....................................................................................................................................................................................................................................
5-36 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing the E1 cables from the AFME1 to Cabling procedures
the E1 cross-connect
............................................................................................................................................................
9 Fix the cables in the cable duct area with cable ties as required.
............................................................................................................................................................
10 Route the open ends of the Transmit and Receive cables from top of
the rack to the DDF.
............................................................................................................................................................
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-37
Issue 1, July 2005 See notice on first page
Cabling procedures
Purpose This procedure describes the E1 cabling for the SHDSL AP LPS510 if
the E1 feature of the LPS510 is used. The maximum distance to the
E1 cross-connect or to digital distribution frame (DDF) can be about
300 ft (≈ 91.5 m).
Connectors on SHDSL AP The SHDSL AP LPS510 is equipped with the standard 68-pin
faceplate connector for the SHDSL ports and is additionally equipped
with a 20-pin AMP connector for 4 unstructured E1 ports. The E1
connector is located directly above the 68-pin AP faceplate connector.
SHDSL E1 cables One Y-cable ED7C860-30 G1 and two ED7C860-30 G2x cables are
required per SHDSL AP LPS510 if the E1 feature of the LPS510 has
to be used.
Notes:
1. With exposed shield. The cross-section of the Group 1 cable is 28
AWG (≈ 0.3 mm diameter), the length is 3 ft (≈ 0.9 m).
2. The cross-section of the Group 2x cable is 26 AWG (≈ 0.4 mm
diameter).
3. For the different lengths refer to the Ordering Guide (363-211-144).
SHDSL E1 cabling The figure below shows the cabling principle for the E1 cabling for
the LPS510.
During installation the two 4-pair E1 cables ED7C860-30 G2x are
routed with their 9-pin D-sub connectors in the left (or right) cable
duct to the LPS510 position in the same manner as the a/b-cables are
installed.
LPS510
n:m
Cable area w.
exposed braided
shield
4 x E1 (Tx)
FAULT
Tx 1 1
ED7C860-30-G2x for Transmit pairs
1
J1 P1/Tx
1
E1
ED7C860-30-G1
Y-cable Rx
1 1 4 x E1 (Rx)
ED7C860-30-G2x for Receive pairs
20-pin AMP connector J2 P2/Rx
AP connector
68-pin AP connector
for the 8 SHDSL ports
RTH4455AAB
Note: The 20-pin AMP connector does not have a designation marking due to its unique design.
Procedure ............................................................................................................................................................
............................................................................................................................................................
3 Mark the two 4-pair E1 cables ED7C860-30 G2x. For the first cable
mark the 9-pin D-sub connector with P1/Tx and the slot position of
the LPS510 and mark the open end in the same manner. For the
second cable mark the 9-pin D-sub connector and the open end with
P2/Rx and the slot position of the LPS510.
............................................................................................................................................................
4 Install the two 4-pair E1 cables with their 9-pin D-sub connectors
from top of the rack in the cable duct to the shelf where the LPS510
is located. Pull the cable ends with the connectors through the shelf
opening.
Note: If the free space in the left cable duct does not allow the
insertion of the cable with the connectors from top of the rack these
two cables must be installed in reverse order with their open end
starting at shelf opening and must be pulled-up with a pulling wire to
the top of the rack.
............................................................................................................................................................
....................................................................................................................................................................................................................................
5-40 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing the E1 cables for the SHDSL AP Cabling procedures
LPS510
............................................................................................................................................................
8 If the LPS510 is not installed place the E1 Y-cable with the 20-pin
AMP connector secured in the cabling area for later connection.
If the LPS510 is installed place the E1 Y-cable so that the 20-pin
AMP connector reaches the female 20-pin AMP connector of the E1
Y-cable to the E1 faceplate connector of the LPS510.
............................................................................................................................................................
10 Route the open ends of the Transmit and Receive cables ED7C860-30
G2x from top of the rack to the DDF.
............................................................................................................................................................
13 Repeat this procedure for all slot positions where LPS510 have to be
installed.
END OF STEPS
..............................................................................................................................................................................
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-41
Issue 1, July 2005 See notice on first page
Cabling procedures
Installing a/b-cables
....................................................................................................................................................................................................................................
a/b Cables The following cables are used for a/b cabling:
Notes:
1. For the different cable lengths refer to the Ordering Guide
(363-211-144).
AP connector pinning The pinning of all application pack connectors used for the different
APs can be found in “Circuit pack and application pack connectors”
(4-79). Four pins on this 68-pin connector are shorted so that the
system can verify whether an application pack cable is connected or
not. pinning
....................................................................................................................................................................................................................................
5-42 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing a/b-cables Cabling procedures
Assumption The described procedure assumes that the a/b cables are fed to the
rack from the top of the rack.
But if the a/b cables are fed to the rack from the floor, then start the
cabling with the shelf in the highest position.
Important! As shown in the table above, special cable types are
used for some APs. Make sure that the correct cable types are
routed to the individual AP slots.
1 Two people are required to feed the cables through the cable duct.
............................................................................................................................................................
3 Sort the cables in that way that the right and left cable duct is evenly
occupied.
............................................................................................................................................................
4 First take the a/b cables for the shelf in the lowest position. Starting
from the cable trough feed the open cable ends through the opening at
both sides of the shelves into the cable ducts and push them to the
cable grid on top of the rack.
............................................................................................................................................................
7 Repeat this procedure for the a/b cables for shelf 2 and shelf 3 if
applicable.
END OF STEPS
..............................................................................................................................................................................
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-43
Issue 1, July 2005 See notice on first page
Cabling procedures
Overview For subscriber lines carrying data (ADSL) and narrowband services
(POTS/ISDN) splitters are used to ″combine″ the narrowband and the
ADSL ports. The main components of the splitter are a low pass filter
(LPF) for the POTS/ISDN side, a high pass filter (HPF) for the ADSL
side and a DC-blocking capacitor for protecting the ADSL port being
affected by the feeding (or ringing) of the POTS/ISDN port.
Cabling principles Depending on the location of the splitter or the parts of the splitter
three different cabling scenarios are used in principle:
• If the complete splitter is located on the ADSL AP the ports of
the POTS/ISDN AP are connected to the appropriate inputs of the
ADSL AP and the outputs of the ADSL AP carrying data and
narrowband services are routed to the subscriber. For the
connecting pattern see Figure 5-19, “ADSL/POTS cabling and
rerouting principle if the complete splitter is on the ADSL AP”
(5-46).
• If the splitter parts are located on both the POTS/ISDN and the
ADSL APs the POTS/ISDN ports and the ADSL ports belonging
together are connected in parallel directly and then routed to the
subscriber This applies to the 32-port ADSL AP LPA432 and the
32-port POTS AP LPZ110 only. For connecting pattern see
Figure 5-20, “ADSL/POTS cabling principle for separate splitters
shared on the ADSL AP and the POTS AP” (5-47).
• If an external splitter shelf is used the POTS/ISDN ports and the
ADSL ports are routed to the appropriate inputs of the splitter
shelf and the outputs of the splitter shelf carrying data and
narrowband services are routed to the subscriber. For connecting
pattern see Figure 5-21, “ADSL/POTS cabling principle for
external splitter shelf with free routing capability” (5-48).
New installation concept The ADSL32 packs LPA432 (POTS over ADSL) and LPA434 (ADSL
over ISDN) are cabled to service-dependent modules (splitter modules
or connect-through modules) integrated in a module container on the
MDF instead of disconnect terminal blocks, see “New installation
concept” (A-13).
The Table 5-5, “Combinations for POTS/ISDN and ADSL APs”
(5-49) shows the possible combinations of the different APs and
shows also the appropriate connecting scheme.
Binder group restrictions A single binder group in the outside plant (OSP) feeder cable should
for the OSP feeder cable not contain subscriber lines that connect to both an ADSL over ISDN
....................................................................................................................................................................................................................................
5-44 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing ADSL cables - Overview Cabling procedures
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-45
Issue 1, July 2005 See notice on first page
Installing ADSL cables - Overview Cabling procedures
Cabling principle for The figure below shows the cabling if the splitter is completely
splitter completely located located on the ADSL AP.
on the ADSL AP
POTS 2 2
Line
2 Subscriber line carrying
Interface
2 POTS and data services
POTS
32x2
AnyMedia Splitter 2
ADSL AP
Z port
LPF
ADSL AP 2
HPF
Transceiver ADSL
port
Splitter 2
Z port
LPF
ADSL AP 2 2
Transceiver HPF
ADSL Subscriber line carrying
port data services only
MDF
switch side subscriber side
(connection/switching type) (disconnection type)
Note that although only POTS are shown here, also ISDN APs can be
used instead, if the appropriate ADSL AP has been selected, see also
Table 5-5, “Combinations for POTS/ISDN and ADSL APs” (5-49).
....................................................................................................................................................................................................................................
5-46 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing ADSL cables - Overview Cabling procedures
Cabling principle for The figure below shows the cabling if the splitter is shared on the
splitter shared on POTS POTS/ISDN AP (LPF) and the ADSL AP (HPF). This applies to the
and ADSL AP 32-port ADSL AP LPA432 and the 32-port POTS AP LPZ110 only.
POTS 2 2
Line LPF
2 Subscriber line carrying
Interface
2 POTS and data services
POTS
ED7C818-30 Gr1x
AnyMedia
ADSL AP LPA432 32x2
Splitter 2 wires of the same type per IDC
(must have the same diameter)
ADSL AP 2 or
HPF a 2-pole connection cord inserted
Transceiver
into the MDF module is used for
the connection POTS to ADSL
ADSL AP 2 2
HPF
Transceiver
Subscriber line carrying
data services only
ED7C818-30 Gr1x
MDF
switch side subscriber side
(connection/switching type) (disconnection type)
Cabling principle for The figure below shows the cabling if an external splitter shelf is
external splitter shelf used. The figure shows for example a situation where the HPF and the
DC blocking capacitor are located on the ADSL AP and the LPF is
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-47
Issue 1, July 2005 See notice on first page
Installing ADSL cables - Overview Cabling procedures
POTS 2 2 2
Line Z port Subscriber line
Interface
carrying POTS
2 services only
POTS 2 2
Line Z port
Interface
24x2 pair*
POTS 2 2
Line Z port
Interface
24x2 pair*
2
2
PHONE
PHONE
ED7C818-30 Gr1x
ADSL
Splitter
ADSL AP 2 2 2
HPF
Transceiver Subscriber line
carrying data
services only
ED7C818-30 Gr1x
Distribution Distribution
(connection/switching type) (disconnection type)
....................................................................................................................................................................................................................................
5-48 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Cabling procedures
Purpose This procedure is used to install the ADSL cables. The ADSL cabling
depends on the site situation and on the MDF type, on the AP and on
the splitter shelf used. Therefore, the cabling procedure is described in
principle only. The cabling has to be done in the order described
below.
Procedure ............................................................................................................................................................
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-49
Issue 1, July 2005 See notice on first page
Installing ADSL cables Cabling procedures
Notes:
1. Connection principle similar to: Figure 5-19, “ADSL/POTS cabling and rerouting principle if the complete
splitter is on the ADSL AP” (5-46).
2. Connection principle similar to: Figure 5-20, “ADSL/POTS cabling principle for separate splitters shared
on the ADSL AP and the POTS AP” (5-47)
3. Connection principle similar to: Figure 5-21, “ADSL/POTS cabling principle for external splitter shelf with
free routing capability” (5-48) or Figure A-10, “Wiring diagram” (A-28).
....................................................................................................................................................................................................................................
5-50 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Cabling procedures
Cables
Table 5-6 E1 feeder cables
Shelf type Description Destination 1 Destination 2 Code
ETSI V5 Shelf E1 cable, 120 Ω DDF D1, E1, F1, G1 EDC7C818-36
for upstream and GR2x 1
downstream direction
1 cable per 8 ports
E1 cable, 75 Ω DDF D1, E1, F1, G1 EDC7C818-36
for upstream and GR3x 1
downstream direction
1 cable per 8 ports
LAG 1900 Shelf E1 cable, 120 Ω DDF J101, J102 EDC7C874-31
for upstream and GR1x 1
downstream direction
1 cable per 8 ports
Notes:
1. For the different cable lengths refer to the Ordering Guide (363-211-144).
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-51
Issue 1, July 2005 See notice on first page
Installing the E1 feeder cables Cabling procedures
1 Obtain the E1 cables of the correct length for the rack location.
............................................................................................................................................................
3 Put the cable ends with the attached D-sub connectors on the cable
grid on top of the rack.
............................................................................................................................................................
4 Feed all E1 cables down in the right cable duct of the rack.
............................................................................................................................................................
8 Route the cables and dress the cables neatly with cable ties or cord.
....................................................................................................................................................................................................................................
5-52 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing the E1 feeder cables Cabling procedures
END OF STEPS
..............................................................................................................................................................................
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-53
Issue 1, July 2005 See notice on first page
Cabling procedures
Purpose This section describes the cabling procedures for the AFMO packs
using fiber cables. Depending on the fiber length, the installation of
optical attenuators will be required.
The connections can be made:
• In simplex AFM mode without daisy-chaining as described
“Installing fiber cables for simplex mode without daisy-chaining”
(5-59)
• In simplex AFM mode with daisy-chaining as described in
“Installing fiber cables for simplex mode with daisy-chaining”
(5-64)
• In duplex AFM mode without daisy-chaining as described in
“Installing fiber cables for duplex mode without daisy-chaining”
(5-69)
• In duplex AFM mode with daisy-chaining as described in
“Installing fiber cables for duplex mode with daisy-chaining”
(5-74)
Connectors The AFMO LPA920 provides two optical feeder interfaces via two
duplex SC-type fiber connectors on the faceplate.
Each optical port of the AFMO supports two single SC-type
connectors or one duplex SC-type connector. Connectors TX-1, RX-1
on the AFM pack are used for upstream connection via two fiber
cables to/from the ATM Network or previous shelf in the daisy chain.
Connectors TX-2, RX-2 are used for downstream connection via two
fiber cables to/from the next daisy-chained shelf. In general a
recommended limit for daisy-chaining is eight BB subsystems. Each
upstream or downstream connection consists of 2 fiber cables, one for
Transmit (TX) and one for Receive (RX). The connectors are shown
in “AFMO pack” (4-94).
Fiber cables Either a duplex fiber with a duplex SC-type connector or two single
fibers with single SC-type connectors can be used. All fibers are
single-mode fibers.
Note: The usage of an optical cable duct is recommended always
when fiber cables have to be installed in the rack. For the installation
of the optical cable duct see “Optical cable duct mounting” (3-25).
....................................................................................................................................................................................................................................
5-54 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing fiber cables for AFMO packs - Cabling procedures
Overview
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-55
Issue 1, July 2005 See notice on first page
Installing fiber cables for AFMO packs - Cabling procedures
Overview
Optical power attenuation Due to the L1.1 long-haul laser transmitter/receiver characteristics
used for the AFMO pack the optical power must be reduced for the
receiver side if two AFMOs are connected via short fibers. Therefore
the fiber cabling should include optical attenuators depending on the
optical loss of the fibers, splices and connectors. The attenuators must
be ordered separately. Type and quantity of the attenuators are
site-specific and depend on the fiber cabling (length, number and
quality of the fibers, connectors and splices for example).
Typically the attenuation required in a daisy-chain is the same for the
transmit and the receive fiber. In general an attenuation of 15 dB is
sufficient for daisy-chaining of two AFMOs over short distances.
....................................................................................................................................................................................................................................
5-56 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing fiber cables for AFMO packs - Cabling procedures
Overview
The location where the attenuator is placed in the fiber loop has no
impact on the correct operation of the AFMOs. It is recommended
that the attenuator is attached directly to the Receive port of the
AFMOs. In this way the correct attenuator value can be verified using
the Transmit laser source of the far end and, if required the attenuator
can be adapted immediately to meet the optical receive power
requirements of the AFMO.
Duplex AFMO mode In duplex AFMO mode two AFMOs are equipped per BB subsystem.
A cross-couple connector 995A as shown in the next figure is required
to interconnect the two AFMOs per shelf electrically.
For daisychaining duplex AFMOs, four fibers are needed per
daisychained BB subsystem.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-57
Issue 1, July 2005 See notice on first page
Installing fiber cables for AFMO packs - Cabling procedures
Overview
Cross couple connector The 995A cross couple connector (Comcode 108765587) is a small
995A device with two male keyed 40-pin connectors. The 995A cross
couple connects the two female cross couple ports on the faceplate of
both AFMOs in one BB subsystem. The cross couple 995A is installed
together with the AFMOs.
995A TOP
LUCENT
Fiber checking All fiber loops should be checked with an optical power meter after
installation to ensure that the complete fiber routing and all connectors
have no impurities, that the right attenuators are equipped and that the
loop has been properly installed.
General laser and fiber The optical AFM packs (AFMO) are equipped with a laser source.
safety information Fibers are routed to these packs.
Lucent lightwave digital transmission system and associated optical
test sets use semiconductor laser transmitters. The lasers emit
lightwaves into lightguide cables, at or near infrared wavelengths that
is invisible to the human eye (wavelengths between 800 nm and 1600
nm).
For further information see “Laser safety guidelines” (1-15).
....................................................................................................................................................................................................................................
5-58 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Cabling procedures
Purpose Use this procedure to install optical feeder cables for one BB
subsystem. If more than one (not daisy-chained) BB subsystem has to
be installed, repeat this procedure for each BB subsystem.
If the AFMO is already installed, the procedure describes how to
install the fiber cables and how to connect them to the AFMO. If the
AFMO is not yet installed, the procedure describes how to install the
cables. In this case the connection to the AFMO will be done during
turn-up of the system.
Assumptions For this procedure only one AFMO pack has to be installed per BB
subsystem (simplex mode). The AFMO will not be in a daisy-chain.
The fiber attenuation on the receive port of the optical STM1
equipment side is not considered in this procedure. This applies
because the attenuation value and the attenuator type is
equipment-specific and will be provided in most cases by the network
provider.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-59
Issue 1, July 2005 See notice on first page
Installing fiber cables for simplex mode Cabling procedures
without daisy-chaining
Fiber 408794535
TX1 RX1
AnyMedia shelf
AFMO
TX2 RX2
Attenuators
....................................................................................................................................................................................................................................
5-60 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing fiber cables for simplex mode Cabling procedures
without daisy-chaining
Procedure
CAUTION
Fiber micro defects and/or cable break with a bending
radius less than 30 mm
There is a risk of causing micro defects in the single fiber or a risk of
a cable break if the bending radius of optical fiber cables is less than
about 30 mm. Micro defects can increase the fiber attenuation and
reduce the long term stability.
Ensure that the bending radius for the single fiber is not less
than 30 mm. Always use the special protective spiral wrap if the
fiber pigtails to the optical packs is equipped with. For the office
fiber cable the allowed bending radius depending on the cable
used must be observed.
............................................................................................................................................................
1 CAUTION
Laser hazard
Lightwave digital transmission systems and associated optical test sets
operate with invisible laser radiation. Laser radiation can cause
damage to the skin and considerable injuries to the eyes. This applies
particularly to the connections of the optical packs. Although, at
present, the transmitting power levels for Class 1 lasers are below
those known to cause injury to the eye at distances greater than
250 mm (≈ 10 inches) direct exposure should always be avoided.
Don’t look into the end of an exposed fiber or optical connector
of a pack as long as the optical source is switched on. Never
view any unterminated optical connector with optical microscope
or magnifying glasses as long as the laser source is switched on.
Always test with an optical power meter or infrared detectors
that the fiber is de-energized and ensure that the laser source can
not be activated during inspection with the microscope.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-61
Issue 1, July 2005 See notice on first page
Installing fiber cables for simplex mode Cabling procedures
without daisy-chaining
............................................................................................................................................................
2 Obtain the two optical fiber cables from the ATM transport network
(408794535) and verify that the end of the transport transmit cable -
connected to the transmit port of the optical STM-1 equipment - is
labeled RX-1 on the AFMO side. Verify that the end of the transport
receive cable - connected to the receive port of the optical STM-1
equipment - is labeled TX-1 on the AFMO side. The marking on the
STM-1 equipment side is site-specific.
Note: Often the receive and the transmit ports of the optical
distribution panel are cross-connected internally, see next figure.
Therefore for example TX-1 fiber is connected to TX (OUT) here.
AFMO
TX-1 OUT IN RX
TX
Transmit
Receive
RX-1 IN OUT TX
RX
Receive Transmit
............................................................................................................................................................
3 Route the two fibers carefully with their TX-1 and the RX-1 fiber
connectors from the top of the rack through the optical cable duct and
pull the fibers very carefully through the shelf opening.
Note: If required a pull-wire must be used.
............................................................................................................................................................
4 If the AFMO is not installed already place the two fiber assemblies in
front of the already installed a/b-cabling in the cable trough for later
installation. Verify that the open ends of the fibers are equipped with
the protective caps. Do not remove the blank faceplate.
....................................................................................................................................................................................................................................
5-62 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing fiber cables for simplex mode Cabling procedures
without daisy-chaining
............................................................................................................................................................
6 Fix the fibers with a waxed cord or with a small cable tie to the
guiding finger. Do not overtighten the cord or the cable tie. Fibers
should only be fixed loosely.
Important! Fiber pinching.
Fibers can be pinched or damaged by the cable tie if the tie is
overtighten. Make sure that the cables are properly placed and
secured to the guiding finger and the cable tie is not overtighten.
............................................................................................................................................................
7 If the work order specifies the testing of the fibers go to the fiber
testing procedure in “Fiber testing procedure” (5-80)
END OF STEPS
..............................................................................................................................................................................
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-63
Issue 1, July 2005 See notice on first page
Cabling procedures
Purpose Use this procedure to install optical feeder cables for a BB subsystem
with daisy-chaining.
For daisy chaining the TX2/RX2 connectors of the previous AMFO
pack in the chain must be connected to the RX1/TX1 connectors of
the next AFMO pack in the chain. In general a recommended limit for
daisy-chaining is eight BB subsystems.
If the AFMOs are already installed, the procedure describes how to
install the fiber cables and how to connect them to the AFMOs. If the
AFMOs are not yet installed, the procedure describes how to install
the fiber cables. In this case the connection to the AFMOs will be
done during turn-up of the system.
Assumptions For this procedure the use of only one AFMO pack per BB subsystem
is assumed (simplex mode). The AFMO will be in a daisy-chain.
Following equipment is required:
• An optical power meter for measuring the power of an optical
STM-1/OC-3c signal on fibers with SC-type connectors.
• If necessary a pull-wire must be available.
• Equipment to clean optical connectors or couplers should be
available.
• Two protected fibers for the connection towards the ATM
network (408794535)
....................................................................................................................................................................................................................................
5-64 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing fiber cables for simplex mode Cabling procedures
with daisy-chaining
• Two protected fibers for the connection to the next AFMO in the
daisy-chain. The fiber length depends on which BB subsystems
have to be daisychained. Select the appropriate length.
• Two optical attenuators are required for the network connection,
one on the AFMO, one on the ATM transport network side (the
installation of the attenuator on the network side is not included
in this procedure). For the calculation of fiber attenuation, see the
Applications and Planning Guide for Narrowband and ATM
xDSL Services (363–211–586).
Fiber 408794535
TX1 RX1
First BB subsystem
in the daisy-chain AFMO
TX2 RX2
TX1 RX1
Next BB subsystem
in the daisy-chain AFMO
TX2 RX2
Attenuators
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-65
Issue 1, July 2005 See notice on first page
Installing fiber cables for simplex mode Cabling procedures
with daisy-chaining
Procedure
CAUTION
Fiber micro defects and/or cable break with a bending
radius less than 30 mm
There is a risk of causing micro defects in the single fiber or a risk of
a cable break if the bending radius of optical fiber cables is less than
about 30 mm. Micro defects can increase the fiber attenuation and
reduce the long term stability.
Ensure that the bending radius for the single fiber is not less
than 30 mm. Always use the special protective spiral wrap if the
fiber pigtails to the optical packs is equipped with. For the office
fiber cable the allowed bending radius depending on the cable
used must be observed.
............................................................................................................................................................
1 CAUTION
Laser hazard
Lightwave digital transmission systems and associated optical test sets
operate with invisible laser radiation. Laser radiation can cause
damage to the skin and considerable injuries to the eyes. This applies
particularly to the connections of the optical packs. Although, at
present, the transmitting power levels for Class 1 lasers are below
those known to cause injury to the eye at distances greater than
250 mm (≈ 10 inches) direct exposure should always be avoided.
Don’t look into the end of an exposed fiber or optical connector
of a pack as long as the optical source is switched on. Never
view any unterminated optical connector with optical microscope
or magnifying glasses as long as the laser source is switched on.
Always test with an optical power meter or infrared detectors
that the fiber is de-energized and ensure that the laser source can
not be activated during inspection with the microscope.
............................................................................................................................................................
4 Mark for the first fiber cable one SC-type connector with RX-2 and
the other connector with TX-1. Mark the second fiber cable with
TX-2 and RX-1 accordingly.
............................................................................................................................................................
5 Insert the two cables into the optical cable duct and route the
RX-2/TX-2 connectors from the cable duct through the shelf opening
where the current AFMO is located.
Note: If required a pull-wire must be used.
............................................................................................................................................................
7 Route the other two free fiber cable ends (labeled TX-1 and RX-1)
through the optical cable duct, then through the opening of the shelf
row where the next AFMO in the daisy-chain is located, and then
through the cable trough below the row to the next AFMO in the
daisy-chain.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-67
Issue 1, July 2005 See notice on first page
Installing fiber cables for simplex mode Cabling procedures
with daisy-chaining
............................................................................................................................................................
9 Fix the fibers very carefully with a waxed cord or with a small cable
tie to the guiding finger. Do not overtighten the cord or the cable tie.
The fibers should only be fixed loosely. Use only one cable tie per
grounding finger and arrange the cables so that they take up as little
space as possible.
Important! Fiber pinching.
The fibers can be pinched or damaged by the cable tie if the tie
is overtighten. Make sure that the cables are proper placed and
secured to the grounding finger and the cable tie is not
overtighten.
............................................................................................................................................................
10 If the work order specifies the testing of the fibers go to the fiber
testing procedure in “Fiber testing procedure” (5-80)
............................................................................................................................................................
11 Repeat this procedure for the next AFMO in the daisy chain, if
applicable.
END OF STEPS
..............................................................................................................................................................................
....................................................................................................................................................................................................................................
5-68 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Cabling procedures
Purpose Use this procedure to install optical feeder cables for a BB subsystem
in duplex mode. A cross-couple connector has to be installed to the
faceplates of the AFMOs to connect them electrically.
If the AFMOs are already installed, the procedure describes how to
install the fiber cables and how to connect them to the AFMOs. If the
AFMOs are not yet installed, the procedure describes how to install
the cables. In this case the connection to the AFMOs will be done
during turn-up of the system.
Assumptions For this procedure two AFMO pack have to be installed per BB
subsystem (duplex mode). The AFMO will not be in a daisy-chain.
The fiber attenuation on the receive port of the optical STM1
equipment side is not considered in this procedure. This applies
because the attenuation value and the attenuator type is
equipment-specific and will be provided in most cases by the network
provider.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-69
Issue 1, July 2005 See notice on first page
Installing fiber cables for duplex mode Cabling procedures
without daisy-chaining
Fiber 408794535
Attenuators
....................................................................................................................................................................................................................................
5-70 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing fiber cables for duplex mode Cabling procedures
without daisy-chaining
Procedure
CAUTION
Fiber micro defects and/or cable break with a bending
radius less than 30 mm
There is a risk of causing micro defects in the single fiber or a risk of
a cable break if the bending radius of optical fiber cables is less than
about 30 mm. Micro defects can increase the fiber attenuation and
reduce the long term stability.
Ensure that the bending radius for the single fiber is not less
than 30 mm. Always use the special protective spiral wrap if the
fiber pigtails to the optical packs is equipped with. For the office
fiber cable the allowed bending radius depending on the cable
used must be observed.
............................................................................................................................................................
1 CAUTION
Laser hazard
Lightwave digital transmission systems and associated optical test sets
operate with invisible laser radiation. Laser radiation can cause
damage to the skin and considerable injuries to the eyes. This applies
particularly to the connections of the optical packs. Although, at
present, the transmitting power levels for Class 1 lasers are below
those known to cause injury to the eye at distances greater than
250 mm (≈ 10 inches) direct exposure should always be avoided.
Don’t look into the end of an exposed fiber or optical connector
of a pack as long as the optical source is switched on. Never
view any unterminated optical connector with optical microscope
or magnifying glasses as long as the laser source is switched on.
Always test with an optical power meter or infrared detectors
that the fiber is de-energized and ensure that the laser source can
not be activated during inspection with the microscope.
Verify that no a/b cables are installed to the blank faceplate of the
AFMO slot positions. Otherwise disconnect the a/b cables from the
faceplate.
Note: The AFMOs/fibers should not be energized at this time. The
protective covers must be left on the fiber connectors until the
connectors have to be connected.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-71
Issue 1, July 2005 See notice on first page
Installing fiber cables for duplex mode Cabling procedures
without daisy-chaining
............................................................................................................................................................
2 Obtain the four optical fiber cables from the ATM transport network
(408794535) and verify that the ends of the transport transmit cable -
connected to the transmit ports of the optical STM-1 equipment - are
labeled RX-1/slot number on the AFMO side. Verify that the ends of
the transport receive cable - connected to the receive ports of the
optical STM-1 equipment - are labeled TX-1/slot number on the
AFMO side. The marking on the STM-1 equipment side is
site-specific.
Note: Often the receive and the transmit ports of the optical
distribution panel are cross-connected internally, see figure below.
Therefore for example TX-1 fiber is connected to TX (OUT) here.
AFMO
TX-1 OUT IN RX
TX
Transmit
Receive
RX-1 IN OUT TX
RX
Receive Transmit
............................................................................................................................................................
3 Route the four fibers carefully with their TX-1/slot number and the
RX-1/slot number fiber connectors from the top of the rack through
the optical cable duct and pull the fibers very carefully through the
shelf opening.
Note: If required a pull-wire must be used.
............................................................................................................................................................
4 If the AFMOs are not installed already place the four fiber assemblies
in front of the already installed a/b-cabling in the cable trough for
later installation. Verify that the open ends of the fibers are equipped
with the protective caps. Do not remove the blank faceplate.
....................................................................................................................................................................................................................................
5-72 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing fiber cables for duplex mode Cabling procedures
without daisy-chaining
5 Fix the fibers with a waxed cord or with a small cable tie to the
guiding finger. Do not overtighten the cord or the cable tie. The fibers
should only be fixed loosely.
If the AFMOs are not yet installed, the cross-couple connector has to
be installed during system turn-up.
Important! Fiber pinching.
The fibers can be pinched or damaged by the cable tie if the tie
is overtighten. Make sure that the cables are properly placed and
secured to the guiding finger and the cable tie is not overtighten.
............................................................................................................................................................
6 If the work order specifies the testing of the fibers go to the fiber
testing procedure in “Fiber testing procedure” (5-80)
END OF STEPS
..............................................................................................................................................................................
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-73
Issue 1, July 2005 See notice on first page
Cabling procedures
Purpose Use this procedure to install optical feeder cables for BB subsystems
in duplex mode in a daisy-chain. Cross-couple connectors have to be
installed to the faceplates of both AFMOs in one BB subsystem to
connect them electrically.
For daisy chaining the TX2/RX2 connectors of the previous AFMO
packs in the daisy-chain must be connected to the RX1/TX1
connectors of the next AFMO packs in the chain. In general a
recommended limit for daisy-chaining is eight BB subsystems.
If the AFMOs are already installed, the procedure describes how to
install the fiber cables and how to connect them to the AFMOs. If the
AFMOs are not yet installed, the procedure describes how to install
the cables. In this case the connection to the AFMOs will be done
during turn-up of the system.
Assumptions For this procedure two AFMO packs have to be installed per BB
subsystem (duplex mode). The AFMO packs will be in a daisy-chain.
The fiber attenuation on the receive ports of the optical STM1
equipment side is not considered in this procedure. This applies
because the attenuation value and the attenuator type is
equipment-specific and will be provided in most cases by the network
provider.
....................................................................................................................................................................................................................................
5-74 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing fiber cables for duplex mode with Cabling procedures
daisy-chaining
Fiber 408794535
Attenuators
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-75
Issue 1, July 2005 See notice on first page
Installing fiber cables for duplex mode with Cabling procedures
daisy-chaining
Procedure
CAUTION
Fiber micro defects and/or cable break with a bending
radius less than 30 mm
There is a risk of causing micro defects in the single fiber or a risk of
a cable break if the bending radius of optical fiber cables is less than
about 30 mm. Micro defects can increase the fiber attenuation and
reduce the long term stability.
Ensure that the bending radius for the single fiber is not less
than 30 mm. Always use the special protective spiral wrap if the
fiber pigtails to the optical packs is equipped with. For the office
fiber cable the allowed bending radius depending on the cable
used must be observed.
............................................................................................................................................................
1 CAUTION
Laser hazard
Lightwave digital transmission systems and associated optical test sets
operate with invisible laser radiation. Laser radiation can cause
damage to the skin and considerable injuries to the eyes. This applies
particularly to the connections of the optical packs. Although, at
present, the transmitting power levels for Class 1 lasers are below
those known to cause injury to the eye at distances greater than
250 mm (≈ 10 inches) direct exposure should always be avoided.
Don’t look into the end of an exposed fiber or optical connector
of a pack as long as the optical source is switched on. Never
view any unterminated optical connector with optical microscope
or magnifying glasses as long as the laser source is switched on.
Always test with an optical power meter or infrared detectors
that the fiber is de-energized and ensure that the laser source can
not be activated during inspection with the microscope.
Start this procedure with the first AFMO pair in the daisy-chain.
Note: The AFMOs/fibers should not be energized at this time. The
protective covers must be left on the fiber connectors until the
connectors have to be connected.
............................................................................................................................................................
2 If the current AFMO pair is the first AFMO pair in the daisy-chain
follow “Installing fiber cables for duplex mode without
....................................................................................................................................................................................................................................
5-76 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing fiber cables for duplex mode with Cabling procedures
daisy-chaining
5 Route the four fiber cables with the RX-2/TX-2 connectors from the
cable duct through the shelf opening where the current AFMO pair is
located.
Note: If required a pull-wire must be used.
............................................................................................................................................................
6 If the AFMOs are not installed already place the four fiber assemblies
in front of the already installed a/b-cabling in the cable trough for
later installation. Verify that the open ends of the fibers are equipped
with the protective caps. Do not remove the blank faceplate.
Have the other cable ends ready for installation as described in Step 7
.
If the AFMOs are installed already
• Obtain one 995A cross couple connector (Comcode 108765587)
and plug into the cross couple ports of both AFMOs. The top of
the 995A cross couple connector is marked.
• Remove the protective caps of two optical attenuators as shown
in “Optical power attenuation” (5-56) and keep them for later use
if the fiber cabling has to be disconnected.
• Attach the optical attenuators properly to the RX-2 ports of the
AFMOs.
• Remove the protective caps of the fibers and keep them for later
use if the fiber cabling has to be disconnected.
• Regarding their labeled slot numbers connect the TX-2 fiber
cable ends to the TX-2 faceplate connectors of the AFMOs,
connect the RX-2 fiber cable connectors to the optical attenuators
on the RX-2 faceplate connector.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-77
Issue 1, July 2005 See notice on first page
Installing fiber cables for duplex mode with Cabling procedures
daisy-chaining
............................................................................................................................................................
7 Obtain the other four free fiber cable ends (labeled TX-1/slot number
and RX-1/slot number) from the cable duct and route them through
the optical cable duct, then through the opening of the shelf row
where the next AFMOs in the daisy-chain are located, and then
through the cable trough below the row to the next AFMOs in the
daisy-chain.
............................................................................................................................................................
9 Fix the fibers very carefully with a waxed cord or with a small cable
tie to the guiding finger. Do not overtighten the cord or the cable tie.
The fibers should only be fixed loosely. Use only one cable tie per
grounding finger and arrange the cables so that they take up as little
space as possible.
Important! Fiber pinching.
The fibers can be pinched or damaged by the cable tie if the tie
is overtighten. Make sure that the cables are proper placed and
secured to the grounding finger and the cable tie is not
overtighten.
....................................................................................................................................................................................................................................
5-78 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing fiber cables for duplex mode with Cabling procedures
daisy-chaining
............................................................................................................................................................
10 If the work order specifies the testing of the fibers go to the fiber
testing procedure in “Fiber testing procedure” (5-80)
............................................................................................................................................................
11 Repeat this procedure for the next AFMO in the daisy chain, if
applicable.
END OF STEPS
..............................................................................................................................................................................
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-79
Issue 1, July 2005 See notice on first page
Cabling procedures
Purpose Perform these steps in principle to verify that the complete fiber
routing and all connectors have no impurities, that the right LBOs are
equipped and that the fiber loop has been properly installed.
Procedure ............................................................................................................................................................
1 CAUTION
Laser hazard
Lightwave digital transmission systems and associated optical test sets
operate with invisible laser radiation. Laser radiation can cause
damage to the skin and considerable injuries to the eyes. This applies
particularly to the connections of the optical packs. Although, at
present, the transmitting power levels for Class 1 lasers are below
those known to cause injury to the eye at distances greater than
250 mm (≈ 10 inches) direct exposure should always be avoided.
Don’t look into the end of an exposed fiber or optical connector
of a pack as long as the optical source is switched on. Never
view any unterminated optical connector with optical microscope
or magnifying glasses as long as the laser source is switched on.
Always test with an optical power meter or infrared detectors
that the fiber is de-energized and ensure that the laser source can
not be activated during inspection with the microscope.
....................................................................................................................................................................................................................................
5-80 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Fiber testing procedure Cabling procedures
............................................................................................................................................................
4 Disconnect the attenuator with the fiber attached on the Receive port
and connect the attenuator to the optical power meter.
Reference:
Wavelength: 1310 ±50 nm
Laser transmit average power: −5 dBm min., 0 dBm max.
Optical receive sensitivity: −34 dBm min., −10 dBm max.
These values apply to L1.1 lasers only, used on AFMO)
............................................................................................................................................................
5 Verify that the optical power is between the Receive Max and Receive
Min values as stated on the work order. If no value is given −22 dB
±1 dB should be sufficient for the AFMO.
• If the power level is in the range of the work order go to Step 7.
• If the power level is not in this range change the attenuators so
that the optical power is within this range. Go to Step 6.
Note: Reducing an attenuator should normally not happen. This could
also indicate that the fiber is defective (microbending) or a fiber
connector is not clean. Before replacing the attenuator the fiber should
be checked especially if the value difference is significantly.
............................................................................................................................................................
7 Disconnect the attenuator with the fiber attached from the optical
power meter and reconnect it to the Receive port.
............................................................................................................................................................
8 Fix the fibers very carefully with a waxed cord or with a small cable
tie to the grounding finger. Do not overtighten the cord or the cable
tie. The fibers should only be fixed loosely.
Important! Fiber pinching.
The fibers can be pinched or damaged by the cable tie if the tie
is overtighten. Make sure that the cables are properly placed and
secured to the guiding finger and the cable tie is not overtighten.
END OF STEPS
..............................................................................................................................................................................
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-81
Issue 1, July 2005 See notice on first page
Cabling procedures
Purpose Use this procedure to install IPFM uplink feeders from the IPFM(s)
towards the IP subsystem.
The IPFM provides two types of uplinks:
• Up to two Gigabit Ethernet (GbE) uplinks GBIC1 and GBIC2
with GBIC modules inserted (fiber cables will be connected here)
• Up to two Fast Ethernet (FE) uplinks FE1 and FE2 (electrical
cables will be connected here: 100 Base-T LAN connector,
designed as 8-pin RJ-45, female)).
Therefore the procedure is subdivided into two sub-procedures, one
for installing the fiber cables to the GBIC modules and one for
installing the electrical cables to the FE ports.
As the IP subsystem supports simplex operation mode and duplex
protection mode for the IPFM, the procedure may be performed a
second time for the protection IPFM if the IP subsystem will run in
duplex mode.
GBIC modules and cables For installing fibers to the GbE uplinks, the following equipment is
required:
• One GBIC module per GbE uplink
Depending on the reach, the following GBIC modules are
available:
– 1000Base-LX
– 1000Base-SX
• One metal radius clip for each fiber cable
The clip has to be installed to protect the fiber if the shelf doors
will be closed.
• The fiber cables will be provided by the customer. The following
is required:
– All connectors are SC type.
– The LX GBIC module accepts either single-mode fiber or
multi-mode fiber.
– The SX GBIC module requires single-mode fiber.
• If fiber cables have to be installed, it is recommended to use the
optional optical cable duct. For detailed information see “Optical
cable duct mounting” (3-25).
....................................................................................................................................................................................................................................
5-82 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing IPFM uplink feeders Cabling procedures
FE uplink cables For the electrical cables to the FE uplink ports the following cables
are required:
• Commercially available 100BaseTX cable (also known as CAT 5
cable)
• Wired ″straight-through″ as described in the table below
• RJ-45 connectors on both ends
• Length suitable for the distance between the IPFM and the
connection point in the IP network.
1 CAUTION
Laser hazard
Lightwave digital transmission systems and associated optical test sets
operate with invisible laser radiation. Laser radiation can cause
damage to the skin and considerable injuries to the eyes. This applies
particularly to the connections of the optical packs. Although, at
present, the transmitting power levels for Class 1 lasers are below
those known to cause injury to the eye at distances greater than
250 mm (≈ 10 inches) direct exposure should always be avoided.
Don’t look into the end of an exposed fiber or optical connector
of a pack as long as the optical source is switched on. Never
view any unterminated optical connector with optical microscope
or magnifying glasses as long as the laser source is switched on.
Always test with an optical power meter or infrared detectors
that the fiber is de-energized and ensure that the laser source can
not be activated during inspection with the microscope.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-83
Issue 1, July 2005 See notice on first page
Installing IPFM uplink feeders Cabling procedures
............................................................................................................................................................
3 Slip the metal radius clip carefully under the rubber boot of the
customer provided fiber.
....................................................................................................................................................................................................................................
5-84 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing IPFM uplink feeders Cabling procedures
............................................................................................................................................................
4 Insert the fiber into the clamp on the other end of the radius clip so
that the fiber is attached closely to the clip.
............................................................................................................................................................
6 Route the fiber through the optical cable duct on the right side of the
rack.
............................................................................................................................................................
2 Route the cable through the left cable duct of the rack to the top.
............................................................................................................................................................
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-85
Issue 1, July 2005 See notice on first page
Cabling procedures
....................................................................................................................................................................................................................................
5-86 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Cabling procedures
Purpose This procedure is applicable only for rack type J1C293B-1 and only if
external office clock will be used.
The ETSI V5 Shelves support simplex station clock. Both, balanced
input (120 Ω) and unbalanced input (75 Ω) from the external clock
source can be terminated. But while balanced input cables are
connected to the FFCU as described here, 75 Ω cables have to be
connected directly to the D2 connectors in the SCP of the ETSI V5
Shelves.
The procedure describes the requirements for manufacturing the 120
Ω clock cable and the installation of the external clock cable between
the clock distribution panel in the FFCU and the customer’s external
clock source.
Background information The FFCU is located in the left part of the RFCP. For a description
refer to “Fan Filter and Clock Distribution Unit (FFCU) ” (4-8)
Note that jumper MP4 and MP5 on the CIU have to be set according
to the impedance used as shown below.
MI
3
MP4
1
75 Ω
120 Ω
1
Legend:
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-87
Issue 1, July 2005 See notice on first page
Installing clock cables - J1C293B-1 Cabling procedures
HI high impedance
clock through, no termination
MI matched impedance
clock terminated
Table 5-11 CIU jumper setting for 120 Ω and 75 Ω clock cables
CIU Cable
Jumper Jumper Termination Setting valid for Impedance Type of
MP4 MP5 impedance pair
120 (1-2) HI (2-3) high DC-powered rack with 120 Ω symmetrical
1
impedance clock distribution
(CDP/FFCU)
75 (2-3) MI (1-2) 75 Ω other station clock 75 Ω coaxial
configuration
Notes:
1. clock through or external termination
Clock input cable The clock input cables are user supplied. They must be manufactured
requirements by the customer/installer.
....................................................................................................................................................................................................................................
5-88 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing clock cables - J1C293B-1 Cabling procedures
Notes:
1. Twisted pair, impedance 120 Ω.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-89
Issue 1, July 2005 See notice on first page
Installing clock cables - J1C293B-1 Cabling procedures
ms
1 2 3 4 5 6 7 8
Oh
121
9 10 11 12 13 14 15
Dummy load
(view of soldering side)
Notes:
All clock cable connectors internally connected by: pin 12 to pin 13 and pin 5 to pin 6
Dummy load connector: 121 W, 1% or 2%, 0.125 W between pin 5 and
pin 12 (for 120-W-cable-termination)
Correct position of dummy The table below shows the correct position of the dummy load
load connector connector, depending on the number of shelves equipped.
Procedure ............................................................................................................................................................
....................................................................................................................................................................................................................................
5-90 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing clock cables - J1C293B-1 Cabling procedures
4 Verify that the internal clock cables are connected correctly according
to the number of shelves equipped.
The internal clock cables are so connected internally that they form a
clock distribution bus. Disconnecting a clock cable will interrupt this
clock bus. Therefore the clock cables must be connected to the
CDP/FFCU one after the other starting with the second connector. An
unused clock connector on the CPP/FFCU between two connected
cables is not allowed.
............................................................................................................................................................
6 Connect the other end of the cable to the external clock source.
END OF STEPS
..............................................................................................................................................................................
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-91
Issue 1, July 2005 See notice on first page
Cabling procedures
Purpose This procedure is applicable only for rack type J1C301B-1 and only if
external clock will be used.
The LAG 1900 Shelves support either simplex station clock or duplex
office clock. Both, balanced input (120 Ω) and unbalanced input
(75 Ω) from the external clock source can be terminated.
The procedure describes
• mounting the second PCD if applicable
• the requirements for manufacturing the 120 Ω clock cable if
required (the 75 Ω cable is commercially available)
• setting the clock termination module into the correct position
• the installation of the internal and external clock cable(s)
Background information At delivery one PCD is located in the left part of the RCP. For a
description refer to “Passive Clock Distribution panel (PCD520)”
(4-20).
Note that jumper MP4 on the CIU has to be set according to the
impedance used, and that jumper MP5 is in position ″HI″ as described
in the Commands and Procedures for Narrowband Services,
(363-211-119) for turn-up.
Required kits Depending on the clock type, use one of the following kits for
internal clock cabling.
Notes:
1. Includes also a second PCD.
Internal clock cables The following table lists all clock cables that may be required for the
two external clock types. These cables are included in the optionally
orderable kits.
....................................................................................................................................................................................................................................
5-92 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing clock cables - J1C301B-1 Cabling procedures
Notes:
1. Cables are included in the kit for station clock (849015904).
2. Cables are included in the kit for office clock (849015896).
Clock input cable The clock input cables (external cables) are user supplied. While the
requirements 75 Ohms cable is commercially available, the 120 Ω cable must be
manufactured by the customer/installer. The following parts are
required:
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-93
Issue 1, July 2005 See notice on first page
Installing clock cables - J1C301B-1 Cabling procedures
Clock termination module The figure below shows the clock termination module which is
connected to one of the PCD outputs (the correct position is specified
in the table below).
Resistor Inductor
100 1.2 µH
5
female
9
4
8
3
7
2
6
1
Correct position of clock The table below shows the correct position of the clock termination
termination module module, depending on the number of shelves equipped (applies to 120
Ω and 75 Ω).
....................................................................................................................................................................................................................................
5-94 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing clock cables - J1C301B-1 Cabling procedures
The figure below shows the position of the connectors on the PCDs.
Coax (UNB)
Coax (UNB)
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-95
Issue 1, July 2005 See notice on first page
Installing clock cables - J1C301B-1 Cabling procedures
Internal
clock cables
Procedure ............................................................................................................................................................
2 If duplex station clock will be used, mount the second PCD with two
screws to the right side of the pre-installed PCD.
............................................................................................................................................................
....................................................................................................................................................................................................................................
5-96 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing clock cables - J1C301B-1 Cabling procedures
5 IF... THEN...
the required clock cable is 120 make sure that the switch on the
Ω, PCD is in position ″BAL″. Do
the same on the second PCD, if
applicable.
the required clock cable is 75 Ω, set the switch on the PCD to
position ″UNBAL″. Then
connect the coax input cable to
the coax connector on the PCD.
Do the same on the second PCD,
if applicable.
Go to Step 10
............................................................................................................................................................
6 Route the internal cables to the right side of the RCP and then
through the cable duct towards the applicable shelf.
............................................................................................................................................................
7 Feed the cables through the shelf opening and connect them to the
clock connectors J109 (and if applicable to J110).
............................................................................................................................................................
11 Connect the other end of the cable(s) to the external clock source.
END OF STEPS
..............................................................................................................................................................................
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-97
Issue 1, July 2005 See notice on first page
Cabling procedures
Introduction The testing of the APs in the shelves can be done either
• Locally, using a TAP-B cable and a TAP10x (TAP10x is a
placeholder for TAP100B and TAP101.)
There are two ways of installing test application paths for local
testing.
– The TAP-B cables which set up the test application paths
can be routed from the TAP10x to the MDF (see “Installing
TAP-B cabling via the MDF” (5-100)) or
– They can be connected to the TAP connector on the shelf
directly (see “Installing TAP-B cabling directly to TAP10x”
(5-106)).
• Using a remote test head unit (RTU) with a test system controller
(TSC) by an operator in a test center. The procedure for this test
installation is described in “Test installation procedure using the
remote test head (RTU) - Overview” (5-109).
The test application paths have to be set up for each shelf separately.
Assumptions A TAP10x will be available in the shelf. It can be inserted into any
free AP slot.
TAP10x The Test Application Pack (TAP10x) is the internal test head
executing the measurements required for the drop.
Each AP can switch any of its subscribers to the General Purpose Bus
(GPB) on the backplane of the shelf. The subscriber can be switched
by the COMDAC either bridged (connection between port and
subscriber line is kept) or split (connection between port and
subscriber line is opened) to the GPB.
The signals of the GPB can be switched by the CIU either to the
CHAN/MONDROP connector on the CIU or to the TAP connector on
the connector field. This TAP connector is connected to the TAP10x
faceplate connector (via the MDF or directly as it is described in this
section. With this cabling the TAP10x can execute the measurements
of a dedicated port (CHAN/MON) of the AP or of the far end
subscriber (DROP). See also Figure 5-38, “Cabling for integrated
testing with TAP10x via the MDF (example )” (5-102).
Cabling For internal testing using the TAP10x the faceplate connector of the
TAP10x must be connected to the TAP connector on the shelf
connector field. Only four wires are required for this cabling.
....................................................................................................................................................................................................................................
5-98 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing the test application paths for local Cabling procedures
testing - Overview
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-99
Issue 1, July 2005 See notice on first page
Cabling procedures
Cabling The connections which have to be made for the ETSI V5 shelves:
Notes:
1. For the different lengths refer to the Ordering Guide (363-211-144).
....................................................................................................................................................................................................................................
5-100 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing TAP-B cabling via the MDF Cabling procedures
The connections which have to be made for the LAG 1900 Shelves:
Notes:
1. For the different lengths refer to the Ordering Guide (363-211-144).
TAP connectors
Table 5-21 TAP-B connector designation
Shelf TAP-B connector Pinning described
in
ETSI V5 Shelf C1 “TAP connector
(C1)” (4-41)
LAG 1900 Shelf J103 “TAP connector
(J103)” (4-62)
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-101
Issue 1, July 2005 See notice on first page
Installing TAP-B cabling via the MDF Cabling procedures
Figure 5-38 Cabling for integrated testing with TAP10x via the
MDF (example )
MDF
Note: If the MDF is outside of the building
equipment side distribution side
the TAP10x cable and all open wires of the
TAP-B cable should have primary protection TAPB_SEIZE
as applicable.
TAPB_FACR
TAPB_FACT
TAPB_EQR
TAPB_EQT
..
. T1
TAP-B cable R1
T2
R2
..
.
a/b cable T32
R32
14
C Shelf Connection Panel
C1
TAP
64
R
COMDAC
COMDAC
TAP100B
AP or AFM
AP or AFM
CIU
AP
AP
AP
AP
CHAN/
MON
1 2 01 02 03 04 13 15 15
DROP
GPB 12
....................................................................................................................................................................................................................................
5-102 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing TAP-B cabling via the MDF Cabling procedures
1 Install TAP-B cable assembly from the top of the rack to the right
cable duct. Pull the cable from the right cable duct to the opening of
the shelf to be wired.
............................................................................................................................................................
2 Check the correct labeling on the TAP cable connector and mark if
required. Mark the other cable end in the direction of the MDF with a
corresponding label designation.
............................................................................................................................................................
3 Mate the connector of the TAP-B cable with the TAP connector on the
connector field of the shelf (C1 for ETSI V5 Shelves, J103 for LAG
1900 Shelves).
Orient the mating cable connector so that the external TAP-B cable
exits the right cable opening of the shelf directly. Carefully place the
cable in the cable opening so that no cable will be damaged. Add
cable ties as needed.
............................................................................................................................................................
5 Terminate the tip/ring pairs at the MDF and check the labeling. Note
the wire color-coding sequence of the factory-prepared cable
assemblies to facilitate the terminations.
............................................................................................................................................................
6 Attach the TAP-B cable with a cable tie to the factory installed cables.
E ND OF STEPS
............................................................................................................................................................
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-103
Issue 1, July 2005 See notice on first page
Installing TAP-B cabling via the MDF Cabling procedures
1 If the slot for the TAP10x plug-in is known, then mark the appropriate
a/b-cable on the MDF.
............................................................................................................................................................
2 Locate the 4 wires for Z port numbers 1 and 2 (tip and ring wire of
subscribers 1 and 2) and mark them.
Important! Only these 2 ports are used by the TAP10x for the
test application path B. These 4 terminals have to be connected
to the TAP-B cable, which runs from the TAP connector on the
connector field to the MDF. On the TAP-B cable 5 wires are
used for the test application path B where the fifth wire is
reserved for future use (seizing).
............................................................................................................................................................
3 If the MDF is located outside the building the a/b-cable coming from
the TAP10x should have primary protection. Follow local regulations
or regulations specified by the network provider to install protector
blocks.
The cross-connections which the installer has to make are described
below.
Important! The testing should be done according to local
regulations.
E ND OF STEPS
............................................................................................................................................................
....................................................................................................................................................................................................................................
5-104 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing TAP-B cabling via the MDF Cabling procedures
Table 5-22 Interconnecting the test application paths via the MDF
Female AnyMedia signal Wire MDF, TAP-B MDF, Wire Female TAP10x AnyMedia signal
conn. C1 for TAP-B side TAP10x connector (from for TAP10x
(from male (example) side male AP13
C1 on SCP) (example) connector)
Notes:
1. For future use using the TAP10x for multiple NE testing (seizing multi TAP) or for multiple testing with
the remote test unit (via wired OR), currently not used
2. Used for crossconnecting to the test application path for Equipment (corresponds to R1/T1 of TAP10x (1st
port)).
3. Used for crossconnecting to the test application path for Facility (corresponds to R2/T2 of TAP10x (2nd
port)).
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-105
Issue 1, July 2005 See notice on first page
Cabling procedures
TAP connectors
Table 5-23 TAP-B connector designation
Shelf Tap-B connector Pinning described
in
ETSI V5 Shelf C1 “TAP connector
(C1)” (4-41)
LAG 1900 Shelf J103 “TAP connector
(J103)” (4-62)
Cabling The TAP-B cable has to be connected from the TAP connector on the
connection panel to the faceplate connector of the TAP10x located in
the same shelf.
....................................................................................................................................................................................................................................
5-106 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing TAP-B cabling directly to TAP10x Cabling procedures
TAP
ED7C818-36 Group 4
T
TAP100B
COMDAC
COMDAC
AP or AFM
AP or AFM
CIU
AP
AP
AP
AP
CHAN/
MON
1 2 01 02 03 04 13 15 15
DROP
12
GPB
Note: The example shows the wiring of the test access path for aETSI V5 s helf. For a
LAG1900 shelf the wiring is similar, but the TAP-B cable used is ED7C867-31 G36
the upper row and ED7C867-31 G36A for the lower row. The TAP connector is J103.
Installing the TAP-B cable The cables should be installed in the following order:
directly
............................................................................................................................................................
1 Obtain the TAP- cable and identify the slot position for the TAP10x
as stated in the work order.
............................................................................................................................................................
............................................................................................................................................................
6 Route the TAP-B cable with the 68-pin AP connector to the right
cable duct and there to the right opening of the same shelf.
............................................................................................................................................................
7 Pull the cable from the right cable duct through the opening and route
the cable to TAP10x position. If the TAP10x is installed already
connect the AP connector to the faceplate connector of the TAP10x. If
the blank faceplate is installed snap in the AP connector.
............................................................................................................................................................
8 Carefully place the cable in the cable trough so that all a/b-cables will
fit in the trough and allow the application packs to be removed.
............................................................................................................................................................
9 Push the cable to the back of the duct, and attach it via cable tie to
the a/b cables.
END OF STEPS
..............................................................................................................................................................................
....................................................................................................................................................................................................................................
5-108 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Cabling procedures
Purpose This procedure describes the cabling for remote subscriber line testing
via one external test equipment per shelf.
Required equipment For the cabling of this remote line testing the following components
are required:
• Remote test head (RTU)
• Cable for the test path (TAP-B cable from the TAP connector to
the remote test head).
• Serial cable from the RTU connector for controlling the NB
subsystem via the external test head.
• Cables for controlling the external test head from the test system
controller (a/b cables towards the MDF, vendor specific cable
between MDF and remote test head).
Important! The NB subsystem can also be controlled via DCN.
For this case the serial connection from the remote test head to
the shelf is not required.
TAP connectors
Table 5-25 TAP-B connector designation
Shelf Tap-B connector Pinning described
in
ETSI V5 Shelf C1 “TAP connector
(C1)” (4-41)
LAG 1900 Shelf J103 “TAP connector
(J103)” (4-62)
TAP-B cable In all cases the 4-wire metallic test path cabling from the NB
subsystem, the TAP connector to the remote test head must be wired
as shown as an example in Figure 5-40, “Cabling for remote testing
(example for the ETSI V5 Shelf)” (5-112)
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-109
Issue 1, July 2005 See notice on first page
Test installation procedure using the remote Cabling procedures
test head (RTU) - Overview
Notes:
1. For the different lengths refer to the Ordering Guide (363-211-144).
RTU connectors
Table 5-27 TAP-B connector designation
Shelf TAP-B connector Pinning described
in
ETSI V5 Shelf H2 “RTU connector
(H2)” (4-45)
LAG 1900 Shelf J106 “RTU connector
(J106)” (4-68)
Controller cable If the NB subsystem is controlled directly from the RTU a serial
RS-232C control link between the remote test head and the NB
subsystem must be wired to the RTU connector (J106 for the LAG
1900 Shelf, H2 for the ETSI V5 Shelf).
....................................................................................................................................................................................................................................
5-110 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Test installation procedure using the remote Cabling procedures
test head (RTU) - Overview
If the control is not performed directly from the remote test head, any
management interface of the system (via DCN) can be used and the
test system controller (TSC) must have two connections to the system
site:
• One control for the NB subsystem
• One control for the remote test head.
Test system controller The remote test head is connected to the TSC which coordinates and
controls the tests carried out by the test head. The type of this
connection is vendor-specific and depends on the capabilities of the
remote test head and the location of the system. Possible connections
are via a modem dial-up connection, serial link, LAN, and so on.
Talk and monitor channel A talk and monitor channel can be used to talk with or listen to a
subscriber under test. A remote test head which supports a talk and
monitor channel has an additional a/b connection (call back line),
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-111
Issue 1, July 2005 See notice on first page
Test installation procedure using the remote Cabling procedures
test head (RTU) - Overview
Figure 5-40 Cabling for remote testing (example for the ETSI V5
Shelf)
4
ETSI V5 shelf TAP-B cable
C Shelf Connection Panel
C1
TAP
RTU
Serial
Internal test link on shelf backplane
MDF RS-232C link on shelf backplane
Reserved Z ports
COMDAC
COMDAC
CIU
AP
AP
AP
AP
AP
AP
CHAN/
MON
1 2 01 02 03 04 15 16
DROP
* RTU vendor-specific
Note: The example shows the wiring of the test access path for aETSI V5 shelf . For a LAG1900
shelf the wiring is similar, but the TAP connector is J106.
....................................................................................................................................................................................................................................
5-112 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Cabling procedures
Purpose The procedure describes the connections of the TAP path to the
external test equipment.
1 Mate the TAP-B connector of the TAP-B cable with the TAP
connector C1 on the connector field of the shelf (C1 for ETSI V5
Shelf, J103 for LAG 1900 Shelf).
Orient the mating cable connector so that the cable exits the right
cable opening of the shelf directly. Carefully place the cable in the
cable opening so that no cable will be damaged. Add cable ties as
needed.
............................................................................................................................................................
2 Connect the 4-wire TAP-B cable to the test path connector (TEST
ACCESS) of the remote test head.
Important! AnyMedia specifies Equipment (EQ) as the
subscriber side and Facility (FAC) as the switching side (AP port
side). Remote test heads may declare these terms in reverse as
specified in GR202 and GR303. Therefore the test paths can be
cross-wired.
............................................................................................................................................................
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-113
Issue 1, July 2005 See notice on first page
Installing the physical connection between Cabling procedures
the RTU and the NB subsystem.
............................................................................................................................................................
6 If the remote test head supports additional talk and monitor capability
then connect the “Talk + Monitor” channel of the remote test head as
a normal POTS subscriber to a reserved Z port via the MDF as
specified in the engineering work order.
END OF STEPS
..............................................................................................................................................................................
....................................................................................................................................................................................................................................
5-114 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Cabling procedures
Purpose Use this procedure to connect the a/b cables to the MDF and
terminate them.
AnyMedia ® Access System installations require a protected wire
system which consists of gastube arrestors on all outside plant
telecommunications circuits (primary protection). Local regulations or
regulations specified by the network provider have to be considered
for installing protector blocks. But the installation of protector blocks
is not part of the installation. It is the customer’s responsibility to
provide them.
Follow local regulations or regulations specified by the network
provider to install protector blocks.
Lucent Technologies delivers, for example, standard circuit 4C1E-W
(black) or special circuit 4C3E-W (red) protectors for the Lucent
MDF.
CAUTION
Destruction of components due to installed cables
without protection
All a/b-cables, E1-, E3/DS3, xDSL-cables and the alarming
cabling should not leave the building premises unless connected
to telecommunication devices providing primary protection (for
example protector blocks with gas discharge tubes) as applicable.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-115
Issue 1, July 2005 See notice on first page
Cabling procedures
Purpose This procedure is used to install the cables from the external power
sources to the rack. It consists of preparing the power cables and
connecting them from the connecting terminals -48A and -48B on
both sides of the circuit breaker blocks to the customer’s external
power sources. These cables must be manufactured by the
customer/installer.
The external power voltage has to be connected to the clamp block
terminals on the right and left side of the power circuit breaker
blocks. Connect the external power cables first to the rack and then to
the external power source. The location of the block terminals and the
circuit breakers can be found in “Power cable connections” (4-5) for
the rack type J1C293B-1 and in “Power cable connections” (4-15) for
the rack type J1C301B-1. Do not use the flat pin plugs.
PFU(s) In LAG 1900 Shelves two PFUs (PFU503) per shelf are mandatory.
For ETSI V5 Shelves one power filter unit (PFU501) is required.
Prerequisite: The PFU(s) have been inserted into the shelf already.
Requirements for external The two power cables for the DC input of the DC-powered racks
power cables routing from customer’s DC source should be
• 2-wire cables
• with double insulation
• recommended wire cross-section of 16 mm2
• strain relief as per EN60950 as applicable.
Fuses Power circuit breakers F1 to F10 are of the single-pole protected type.
Only the terminal for -48 V-potential (-48 V A/-48 V B) is protected,
the other terminal is permanently connected to the -48 V
RTN-potential (-48 V RTNA/-48 V RTNB). The table below shows
the fusing values for all circuit breakers F1 to F10, equipped or not.
....................................................................................................................................................................................................................................
5-116 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing -48 V power feeder cables Cabling procedures
CAUTION
Destruction of components due to a supply voltage
of incorrect polarity or a supply voltage which is too
high
The AnyMedia ® Access System operates at a nominal voltage of
–48 V DC. The permissible tolerance range is −40.5 V to −57 V
DC.
Ensure that the supply voltage has the correct range and polarity
before connecting the voltage. The AnyMedia ® Access System
should be operated only from the type of power source indicated
on the marking label. Ensure that fuses will be replaced with the
same type and rating of fuse. Never connect the AnyMedia ®
Access System to −60 V DC.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-117
Issue 1, July 2005 See notice on first page
Installing -48 V power feeder cables Cabling procedures
Procedure ............................................................................................................................................................
1 Verify that the customer’s power source delivers the voltage and as
indicated in the engineering work order. If required measure the
voltage on the customer’s power source.
............................................................................................................................................................
2 Verify that the customer’s two power sources are switched to “OFF”
and secure the power sources against cutting or connecting in again.
Mark if required. Follow local regulations especially if the power
source is located in CO.
............................................................................................................................................................
3 Measure the voltage on the customer’s ringing source and verify that
it is de-energized. Follow local regulations.
............................................................................................................................................................
4 Verify that all power circuit breakers on the RFCP (or on the RCP
respectively) are switched to “OFF”.
............................................................................................................................................................
5 Route the two power cables from the customer’s power sources to the
rack. Do not connect.
............................................................................................................................................................
6 Install the power cables from the top of the rack and route them to the
upper fixing fingers of the RFCP (or of the RCP respectively).
............................................................................................................................................................
7 Strip the two power cables to a length of 100 mm. Strip each of the
two wires per cable to a length of 8 mm.
............................................................................................................................................................
10 Attach the cables of the power feeders with cable ties to free fixing
fingers.
............................................................................................................................................................
11 Insert the -48 V return wires of both power feeders into the clamp
terminals ″N+″ of the -48 A-block and screw tight.
............................................................................................................................................................
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-119
Issue 1, July 2005 See notice on first page
Cabling procedures
Purpose This procedure is applicable only if the work order specifies that
external ringing voltage will be used. The ETSI V5 Shelves only
support external ringing voltage.
Skip this procedure for J1C293B1 racks which are not intended to be
connected to external ringing sources.
For using external ringing voltage rack type J1C293B-1, L3 is
required, which is equipped with three Ringing Filter Units (RFUs)
and internal ringing cables.
This procedure consists of preparing the external ringing cable and
connecting it from the ringing clamps in the rack to the customer’s
external central ringing source.
The ringing clamps are factory connected to the Ringing Filter Units
which are located in the RFCP.
The external cable must be manufactured by the customer/installer.
Important! Always connect the external ringing cable first to the
AnyMedia ® Access System and then to the office supplies. The
ring return wire must be connected externally to the ″-48 V
Return″ of the customer’s ringing supply.
Ringing cables for The following table lists the internal cables. These cables are included
J1C293B-1 in the optionally orderable kit.
Requirements for external The ringing cable connected to the two ringing clamps should be a
ringing cable 2-wire cable with double insulation, wire cross-section of 1.5 mm2
and strain relief as per EN 60950.
Note: The terminals of two ringing clamps allow wires to be
connected of cross-sections from 0.75 to 4 mm2 for solid wire. The
wires must have reinforced insulation.
Fusing values The ringing filter units are equipped with front accessible glass-type
fuses (5x20) of a nominal value of 1 A for RFU 501 used for ETSI
....................................................................................................................................................................................................................................
5-120 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing ringing cables - J1C293B-1 Cabling procedures
WARNING
Electric shock hazard
Dangerous Ringing Voltage.
The AnyMedia Access System is fed by ringing voltages of 57 V
DC maximum superimposed by 105 V AC maximum. Touching live
ringing cables will shock or cause serious injury or death. Take
care when servicing in this area. Follow all safety warnings and
local regulation practices.
Before you begin Verify that the customer’s ringing source delivers the voltage and the
ringing frequency as indicated in the engineering work order. If
required measure the voltage on the customer’s ringing source.
Verify that the customer’s ringing source is de-energized. If required
short the deactivated mains to earth. Follow local regulations.
Installing the ringing The external ringing voltage has to be connected to the two ringing
cables clamps only as shown in the figures because the other terminals are
factory cross-wired to metalwork (FRMGND) of the RFUs and to the
line side of the ringing filter units, connector J11, see the following
figure.
RNG
Connected to Terminals for customer's
V5 Shelf 1, J1 Connected to ringing voltage
Connected to V5 Shelf 3, J1
V5 Shelf 2, J1
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-121
Issue 1, July 2005 See notice on first page
Installing ringing cables - J1C293B-1 Cabling procedures
Procedure ............................................................................................................................................................
1 Verify that all ringer output connectors J21 on the RFUs are
disconnected. If not already done disconnect the three connectors J21.
............................................................................................................................................................
2 Route the ringing cable from the customer’s ringing source to the
rack. Do not connect.
............................................................................................................................................................
4 Install the ringing cable from the top of the rack and route it to the
upper fixing fingers of the RFCP directly.
............................................................................................................................................................
5 Attach the cable with cable ties to the cable holder to a free fixing
finger near the ringing clamps. If the cable is of shielded-type remove
the insulation partly so that the screen makes metallic contact with the
grounding finger.
............................................................................................................................................................
6 Strip the ringing cable to a length of 30 mm. Strip each of the two
wires to a length of 8 mm.
............................................................................................................................................................
9 Press down the inner clamp and insert the TRG wire of the ringing
cable from the front in the lower terminal.
............................................................................................................................................................
10 Remove the screwdriver and check that the TRG wire is firmly fixed
in the clamp.
............................................................................................................................................................
12 Press down the inner clamp and insert the RRG wire of the ringing
cable from the front in the lower terminal.
....................................................................................................................................................................................................................................
5-122 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing ringing cables - J1C293B-1 Cabling procedures
............................................................................................................................................................
13 Remove the screwdriver and check that the RRG wire is firmly fixed
in the clamp.
Note: The ring return wire must be connected to the ″−48 V Return″
of the customer’s ringing supply.
............................................................................................................................................................
1
RNG_RTN for J11 and J21
J11 or J21
END OF STEPS
..............................................................................................................................................................................
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-123
Issue 1, July 2005 See notice on first page
Cabling procedures
Purpose This procedure is applicable for shelf type J1C301B-1 and only if the
work order specifies that external ringing voltage will be used. The
LAG 1900 Shelf supports external (centralized) or local ringing
voltage.
For local ringing supply two ringing generator units (RGUs) of the
same type have to be equipped in the upper row of the LAG 1900
Shelf. The RGUs may be battery-backed (RGU500) or earth-backed
(RGU510).
For using external ringing voltage the optional kit for external ringing
(849015888) is required, containing three ringing termination blocks,
jumpers and internal ringing cables.
Skip this procedure for LAG 1900 Shelves that have an RGU installed
and therefore do not use external ringing voltage.
This procedure consists of
• mounting the ringing termination blocks
• installing the jumpers between the ringing termination blocks
• installing internal ringing cables
• installing external cable.
The external cable must be manufactured by the customer/installer.
Important! Always connect the ringing cable first to the
AnyMedia ® Access System and then to the office supplies. The
ring return wire must be connected externally to the ″-48 V
Return″ of the customer’s ringing supply.
Ringing cables for The following table lists the internal cables. These cables are included
J1C301B-1 in the optionally orderable kit.
Notes:
1. Cables are included in the kit for external ringing (849015888).
....................................................................................................................................................................................................................................
5-124 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing ringing cables - J1C301B-1 Cabling procedures
Requirements for external The ringing cable connected to the two ringing clamps should be a
ringing cable 2-wire cable with double insulation, wire cross-section of 1.5 mm2
and strain relief as per EN 60950.
Note: The terminals of two ringing clamps allow wires to be
connected of cross-sections from 0.75 to 4 mm2 for solid wire. The
wires must have reinforced insulation.
If the length of the external unshielded ringing cable exceeds three
meters (shielded 10 m) a ringing filter unit (RFU503) has to be
installed in the LAG 1900 Shelf.
Fusing values The ringing filter units are equipped with front accessible glass-type
fuses (5x20) of a nominal value of 2 A for RFU503 used within LAG
1900 Shelves. Only the output connector terminal for connecting the
ring potential (RRG) is protected.
WARNING
Electric shock hazard
Dangerous Ringing Voltage.
The AnyMedia ® Access System is fed by ringing voltages of 57 V
DC maximum superimposed by 105 V AC maximum. Touching live
ringing cables will shock or cause serious injury or death. Take
care when servicing in this area. Follow all safety warnings and
local regulation practices.
Before you begin Verify that the customer’s ringing source delivers the voltage and the
ringing frequency as indicated in the engineering work order. If
required measure the voltage on the customer’s ringing source.
Verify that the ringing source is de-energized. If required short the
deactivated mains to earth. Follow local regulations.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-125
Issue 1, July 2005 See notice on first page
Installing ringing cables - J1C301B-1 Cabling procedures
The figure below shows the position of the ringing termination blocks
and all necessary cables for ringing. At delivery the three ringing
termination blocks are not equipped.
to/from external
ringing source
jumpers jumpers
Tip
Ring
....................................................................................................................................................................................................................................
5-126 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing ringing cables - J1C301B-1 Cabling procedures
Mounting ringing The following step has to be carried out for each of the three
termination blocks ringing termination blocks.
............................................................................................................................................................
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-127
Issue 1, July 2005 See notice on first page
Installing ringing cables - J1C301B-1 Cabling procedures
Installing jumpers Two jumper pairs have to be installed as shown in Figure 5-43,
“Ringing cables for J1C301B-1” (5-126) to interconnect the
ringing termination blocks.
............................................................................................................................................................
1
Important! Do not mix the polarity of the jumpers.
Lift the clamp of the ringing termination block and insert one end of
the jumper. Press down the clamp.
Check that the jumper is firmly fixed in the clamp.
............................................................................................................................................................
2 Lift the clamp of the next ringing termination block and insert the
other end of the jumper. Press down the clamp.
Check that the jumper is firmly fixed in the clamp.
............................................................................................................................................................
1 Route the external ringing cable from the customer’s ringing source to
the rack. Do not connect.
............................................................................................................................................................
3 Install the ringing cable from the top of the rack and route it to the
left ringing termination block as shown in Figure 5-44, “Routing of
the ringing cables” (5-127).
............................................................................................................................................................
4 Attach the cable with cable ties near the ringing termination block. If
the cable is of shielded-type remove the insulation partly so that the
screen makes metallic contact with the grounding finger.
............................................................................................................................................................
5 Strip the ringing cable to a length of 30 mm. Strip each of the two
wires to a length of 8 mm.
....................................................................................................................................................................................................................................
5-128 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Installing ringing cables - J1C301B-1 Cabling procedures
............................................................................................................................................................
7 Lift the upper clamp and insert the TRG wire of the ringing cable.
Press down the upper clamp.
Check that the TRG wire is firmly fixed in the clamp.
............................................................................................................................................................
8 Lift the lower clamp and insert the RRG wire of the ringing cable.
Press down the lower clamp.
Check that the RRG wire is firmly fixed.
E ND OF STEPS
............................................................................................................................................................
Installing the internal Install the internal ringing cables according to Table 5-31,
cables “Ringing cables (LAG 1900)” (5-124).
............................................................................................................................................................
1 Lift the clamps of the ringing termination block and insert the
appropriate ringing cable. Press down the clamps.
Check that the ringing cable is firmly fixed in the clamps.
............................................................................................................................................................
2 Route the internal ringing cables according to the table below to the
right side of the RCP as shown in Figure 5-44, “Routing of the
ringing cables” (5-127) and then through the cable duct towards the
applicable shelf.
............................................................................................................................................................
3 Feed the cables through the shelf opening and connect them to the
ringing connectors P113.
END OF STEPS
..............................................................................................................................................................................
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-129
Issue 1, July 2005 See notice on first page
Cabling procedures
Pre-installed
internal cables
to V5 Shelf 1 to V5 Shelf 1
(connector A1) (connector B1)
to V5 Shelf 2 to V5 Shelf 2
(connector A1) (connector B1)
to V5 Shelf 3 to V5 Shelf 3
(connector A1) (connector B1)
....................................................................................................................................................................................................................................
5-130 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Testing the power and ringing feeding Cabling procedures
RNG
Connected to Terminals for customer's
V5 Shelf 1, J1 Connected to ringing voltage
Connected to V5 Shelf 3, J1
V5 Shelf 2, J1
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-131
Issue 1, July 2005 See notice on first page
Testing the power and ringing feeding Cabling procedures
+ +
....................................................................................................................................................................................................................................
5-132 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Testing the power and ringing feeding Cabling procedures
to/from external
ringing source
jumpers jumpers
Tip
Ring
WARNING
Electric shock hazard
Dangerous Ringing Voltage.
The AnyMedia Access System is fed by ringing voltages of 57 V
DC maximum superimposed by 105 V AC maximum. Touching live
ringing cables will shock or cause serious injury or death. Take
care when servicing in this area. Follow all safety warnings and
local regulation practices.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-133
Issue 1, July 2005 See notice on first page
Testing the power and ringing feeding Cabling procedures
CAUTION
Destruction of components due to a supply voltage
of incorrect polarity or a supply voltage which is too
high
The AnyMedia ® Access System operates at a nominal voltage of
–48 V DC. The permissible tolerance range is −40.5 V to −57 V
DC.
Ensure that the supply voltage has the correct range and polarity
before connecting the voltage. The AnyMedia ® Access System
should be operated only from the type of power source indicated
on the marking label. Ensure that fuses will be replaced with the
same type and rating of fuse. Never connect the AnyMedia ®
Access System to −60 V DC.
Procedure ............................................................................................................................................................
2 Verify absence of any shorts between the RTN terminals and the -48V
or ringing terminals of the power feeders.
............................................................................................................................................................
6 Measure the -48V and the ringing voltage and check for correct
polarity at first at the customers source and then on the line side of
the two block terminals for the -48 V and on the ringing clamps for
the ringing voltage.
....................................................................................................................................................................................................................................
5-134 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Testing the power and ringing feeding Cabling procedures
............................................................................................................................................................
11 Turn off the circuit breakers and disconnect the customer’s ringing
and power supply sources.
END OF STEPS
..............................................................................................................................................................................
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 5-135
Issue 1, July 2005 See notice on first page
Cabling procedures
Purpose This procedure is used to finalize the installation that means to mount
components that have been removed during installation.
Procedure ............................................................................................................................................................
1 Mount the cover plates that have been removed temporarily on front
of the connector fields of the LAG 1900 Shelves and fasten them with
the two screws..
............................................................................................................................................................
....................................................................................................................................................................................................................................
5-136 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
6 Maintenance
Overview
....................................................................................................................................................................................................................................
Purpose After the installation of the DC-powered rack has been completed, no
actions are required for maintenance purposes.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary 6-1
Issue 1, July 2005 See notice on first page
Appendix A: Supplemental
Information
Overview
....................................................................................................................................................................................................................................
Technical support groups Lucent Technologies service personnel will troubleshoot field
problems 24 h a day over the phone and on site (if necessary) based
on Lucent Technologies service contracts by
• Local/Regional Customer Support (LCS/RCS)
• Remote Technical Support (RTS)
• For Europe call the International Customer Management Center
(ICMC): +353 1692 4579 or call the toll free number: 00 800 00
58 2368
• For Asia Pacific, Caribbean and Latin America Region, Saudi
Arabia, Middle East and Africa call the local Lucent
Technologies Customer Technical Support Team.
Contents
Connectors and cables A-3
Color-Coding for cables A-3
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary A-1
Issue 1, July 2005 See notice on first page
Overview Supplemental Information
....................................................................................................................................................................................................................................
A-2 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Supplemental Information
Overview This section explains the abbreviations used for the color coding of
cables in several tables within this document. Moreover, standard wire
color coding for the factory assembled a/b cables is shown. Use of the
color coding will facilitate both terminating operations at the
customer’s cross-connecting points and troubleshooting routines.
Color coding abbreviations The following color-coding abbreviations are used for identification
on the cables.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary A-3
Issue 1, July 2005 See notice on first page
Connectors and cables Supplemental Information
Color-Coding for cables
Color coding for a/b cables The table below shows the color-coding for the 1×32-pair a/b cables
and the two tables after that show it for the 2×32-pair a/b cables.
Table A-2 Color coding for the 1x32 pair a/b cables
Conductor Connector Binder Identification Color coding
pair no. terminals color colors (Tip/Ring)
1 12, 13 blue white-blue/blue- W-BL/BL-W
white
2 14, 15 blue white-orange/ W-O/O-W
orange-white
3 16, 17 blue white-green/green- W-G/G-W
white
4 18, 19 blue white-brown/brown- W-BR/BR-W
white
5 20, 21 blue white-slate/slate- W-S/S-W
white
6 22, 23 blue red-blue/blue-red R-BL/BL-R
7 24, 25 blue red-orange/orange- R-O/O-R
red
8 26, 27 blue red-green/green-red R-G/G-R
9 28, 29 blue red-brown/brown- R-BR/BR-R
red
10 30, 31 blue red-slate/slate-red R-S/S-R
11 32, 33 blue black-blue/blue- BK-BL/
black BL-BK
12 34, 35 blue black-orange/ BK-O/O-BK
orange-black
13 36, 37 blue black-green/green- BK-G/G-BK
black
14 38, 39 blue black-brown/brown- BK-BR/
black BR-BK
15 40, 41 blue black-slate/slate- BK-S/S-BK
black
16 42, 43 blue yellow-blue/blue- Y-BL/BL-Y
yellow
....................................................................................................................................................................................................................................
A-4 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Connectors and cables Supplemental Information
Color-Coding for cables
Table A-2 Color coding for the 1x32 pair a/b cables
(continued)
Conductor Connector Binder Identification Color coding
pair no. terminals color colors (Tip/Ring)
19 48, 49 orange white-green/green- W-G/G-W
white
20 50, 51 orange white-brown/brown- W-BR/BR-W
white
21 52, 53 orange white-slate/slate- W-S/S-W
white
22 54, 55 orange red-blue/blue-red R-BL/BL-R
23 56, 57 orange red-orange/orange- R-O/O-R
red
24 58, 59 orange red-green/green-red R-G/G-R
25 60, 61 orange red-brown/brown- R-BR/BR-R
red
26 62, 63 orange red-slate/slate-red R-S/S-R
27 64, 65 orange black-blue/blue- BK-BL/
black BL-BK
28 66, 67 orange black-orange/ BK-O/O-BK
orange-black
29 68, 69 orange black-green/green- BK-G/G-BK
black
30 70, 71 orange black-brown/brown- BK-BR/
black BR-BK
31 72, 73 orange black-slate/slate- BK-S/S-BK
black
32 74, 75 orange yellow-blue/blue- Y-BL/BL-Y
yellow
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary A-5
Issue 1, July 2005 See notice on first page
Connectors and cables Supplemental Information
Color-Coding for cables
P1
P2
Table A-3 Color coding for the P1 connector 2×32 pair a/b
cable Tip/Ring 1-32
Connector Binder Color coding Tip/Ring
terminals color
on P1
33, 1 blue W-BL/BL-W Tip1/Ring1
34, 2 blue W-O/O-W Tip2/Ring2
35, 3 blue W-G/G-W Tip3/Ring3
36, 4 blue W-BR/BR-W Tip4/Ring4
37, 5 blue W-S/S-W Tip5/Ring5
38, 6 blue R-BL/BL-R Tip6/Ring6
39, 7 blue R-O/O-R Tip7/Ring7
40, 8 blue R-G/G-R Tip8/Ring8
41, 9 blue R-BR/BR-R Tip9/Ring9
42, 10 blue R-S/S-R Tip10/Ring10
43, 11 blue BK-BL/BL-BK Tip11/Ring11
44, 12 blue BK-O/O-BK Tip12/Ring12
45, 13 blue BK-G/G-BK Tip13/Ring13
46, 14 blue BK-BR/BR-BK Tip14/Ring14
47, 15 blue BK-S/S-BK Tip15/Ring15
48, 16 blue Y-BL/BL-Y Tip16/Ring16
49, 17 orange W-BL/BL-W Tip17/Ring17
50, 18 orange W-O/O-W Tip18/Ring18
51, 19 orange W-G/G-W Tip19/Ring19
52, 20 orange W-BR/BR-W Tip20/Ring20
53, 21 orange W-S/S-W Tip21/Ring21
54, 22 orange R-BL/BL-R Tip22/Ring22
55, 23 orange R-O/O-R Tip23/Ring23
56, 24 orange R-G/G-R Tip24/Ring24
....................................................................................................................................................................................................................................
A-6 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Connectors and cables Supplemental Information
Color-Coding for cables
Table A-3 Color coding for the P1 connector 2×32 pair a/b
cable Tip/Ring 1-32 (continued)
Connector Binder Color coding Tip/Ring
terminals color
on P1
57, 25 orange R-BR/BR-R Tip25/Ring25
58, 26 orange R-S/S-R Tip26/Ring26
59, 27 orange BK-BL/BL-BK Tip27/Ring27
60, 28 orange R-O/O-R Tip28/Ring28
61, 29 orange BK-G/G-BK Tip29/Ring29
62, 30 orange BK-BR/BR-BK Tip30/Ring30
63, 31 orange BK-S/S-BK Tip31/Ring31
64, 32 orange Y-BL/BL-Y Tip32/Ring32
Table A-4 Color coding for the P2 connector 2×32 pair a/b
cable Tip/Ring 33-64
Connector Binder Color coding Tip/Ring
terminals color
on P2
33, 1 green W-BL/BL-W Tip33/Ring33
34, 2 green W-O/O-W Tip34/Ring34
35, 3 green W-G/G-W Tip35/Ring35
36, 4 green W-BR/BR-W Tip36/Ring36
37, 5 green W-S/S-W Tip37/Ring37
38, 6 green R-BL/BL-R Tip38/Ring38
39, 7 green R-O/O-R Tip39/Ring39
40, 8 green R-G/G-R Tip40/Ring40
41, 9 green R-BR/BR-R Tip41/Ring41
42, 10 green R-S/S-R Tip42/Ring42
43, 11 green BK-BL/BL-BK Tip43/Ring43
44, 12 green BK-O/O-BK Tip44/Ring44
45, 13 green BK-G/G-BK Tip45/Ring45
46, 14 green BK-BR/BR-BK Tip46/Ring46
47, 15 green BK-S/S-BK Tip47/Ring47
48, 16 green Y-BL/BL-Y Tip48/Ring48
49, 17 brown W-BL/BL-W Tip49/Ring49
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary A-7
Issue 1, July 2005 See notice on first page
Connectors and cables Supplemental Information
Color-Coding for cables
Table A-4 Color coding for the P2 connector 2×32 pair a/b
cable Tip/Ring 33-64 (continued)
Connector Binder Color coding Tip/Ring
terminals color
on P2
50, 18 brown W-O/O-W Tip50/Ring50
51, 19 brown W-G/G-W Tip51/Ring51
52, 20 brown W-BR/BR-W Tip52/Ring52
53, 21 brown W-S/S-W Tip53/Ring53
54, 22 brown R-BL/BL-R Tip54/Ring54
55, 23 brown R-O/O-R Tip55/Ring55
56, 24 brown R-G/G-R Tip56/Ring56
57, 25 brown R-BR/BR-R Tip57/Ring57
58, 26 brown R-S/S-R Tip58/Ring58
59, 27 brown BK-BL/BL-BK Tip59/Ring59
60, 28 brown R-O/O-R Tip60/Ring60
61, 29 brown BK-G/G-BK Tip61/Ring61
62, 30 brown BK-BR/BR-BK Tip62/Ring62
63, 31 brown BK-S/S-BK Tip63/Ring63
64, 32 brown Y-BL/BL-Y Tip64/Ring64
....................................................................................................................................................................................................................................
A-8 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Connectors and cables Supplemental Information
Connector types
....................................................................................................................................................................................................................................
Overview The connector types employed in the system are the following:
• Application pack 68-pin connectors with ejector, used for
POTS/ADSL/ISDN interface connections
• Application pack 2 x 32 pin connectors with ejector, used for
POTS interface connections
• Application pack connectors with screws (for VoIP APs)
• AMP 8-position power linking terminals used for DC power
connectors and ringing
• Molex connectors with 2-pin and 4-pin and 6-pin arrangement
used for connecting the the external ringing voltage to the
AnyMedia ® Access System
• Molex connectors with 4-pin arrangement used for connecting the
external -48 V power to the PFUs
• AMP connectors with 6-pin arrangement for the internal power
connection to the PFUs
• AMP Faston connectors used to connect the -48 V to the
AnyMedia Shelves (AMP and Faston are registered trademarks of
AMP, Inc.).
• D-subminiature DB pin arrangements used to connect the -48 V
to the Shelves
• D-subminiature DB9, DB15, DB25, DB37 pin arrangements used
for digital signal transmission (E1), clock and alarming
• BNC and mini coaxial connectors for E3/DS3
• RJ45 connectors for LAN
• SC-type connectors for fibers from/to the optical packs
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary A-9
Issue 1, July 2005 See notice on first page
Connectors and cables Supplemental Information
Connector types
1 1
2 2
D-Type connectors D-type connectors are provided in the system with DB9, DB15, DB25
and DB37 pin arrangements. While all D-type connectors on the LAG
Shelf are female, most of the D-type connectors on the ETSI V5 Shelf
are male (exceptions are J2 for LAN interface, H2 for RTU link and
F2 for miscellaneous alarm inputs).
Each D-type plug/jack connector combination has an associated
covering (hood) which must be installed over the connector to
complete the assembly. The figure below depicts the D-type
connectors and the hood/hardware assemblies for mating the
connectors together.
Terminal numbers are embossed on the pin side of the assembly.
....................................................................................................................................................................................................................................
A-10 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Connectors and cables Supplemental Information
Connector types
Molex and AMP connectors Molex connectors are provided in various housings with pins for
crimping requiring only standard crimping tools. Each Molex
connector is keyed to fit with its mating connector
2
1
2 3
SC type fiber connectors, For the fiber cabling of the GbE uplinks on the IPFM and to the
attenuators and optical AFM (AFMO) SC-type connectors are used.
cross-couple connectors
On the AFMO two optical ports with one Receive fiber (RX) and one
Transmit fiber (TX) per port are supported for daisy-chaining (see the
following figure).
Each optical port of the AFMO supports two single SC-type
connectors or one duplex SC-type connector. If optical attenuation is
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary A-11
Issue 1, July 2005 See notice on first page
Connectors and cables Supplemental Information
Connector types
required and the Lucent lightguide buildouts are used two single
SC-type connectors must be used.
10BASE
TX-1
From the optical STM-1/OC-3c
Port 1 ATM feeder interface
RX-1
or from previous shelf
in the optical daisy-chain
TX-2
995A TOP
LUCENT
BNC connectors on the The AFME3/DS3 contains 4 BNC connectors on the faceplate for
AFME3/AFMDS3 packs connecting the E3/DS3-cables. Connectors TX1, RX1 are used for
upstream, connecting via coaxial cables to/from the ATM backbone.
Connectors TX2, RX2 are used for downstream, connecting via
coaxial cables to/from the next daisy-chained shelf.
....................................................................................................................................................................................................................................
A-12 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Supplemental Information
Overview
....................................................................................................................................................................................................................................
Purpose The new installation concept (NIC) makes use of small module
containers (see next Figure) which are mounted on the MDF instead
of disconnect terminal blocks. The height of a module corresponds to
that of conventional disconnect terminal blocks.
Module container
The module containers are equipped with compact application-specific
modules. Four of them are connected via a 32-pair a/b cable to one
AP in the AnyMedia ® Access System. Depending on the service
either connect-through modules or highly advanced splitter modules
can be used without changing the system cabling. Therefore there is
no need to install external splitter shelves in case of BB service. One
module container can be equipped with up to 4 modules and can
support 32 subscribers. The modules are designed to support 8
subscribers each. Each module is connected on the rear side with
eight pairs of the application pack cable of the AnyMedia ® Access
System. The NB service is fed to the left side on the front of each
module. The combined ADSL signal of these eight subscribers is
available on the right side on the front of each module.
Connect-through modules directly connect the system cabling to the
subscriber lines while splitter modules combine ADSL and NB
services on the subscriber line. For NB services, only connect-through
modules are used.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary A-13
Issue 1, July 2005 See notice on first page
New installation concept Supplemental Information
Overview
Contents
Cross-connection between AP connector - EC A-15
connectors
Installation and wiring of the module container A-16
Installation sequence module container with 32-pair A-17
cable
Replacement of the modules A-22
Replacement of the module container A-25
a/b Wiring for module container on subscriber side A-28
Converting a subscriber loop from NB only to ADSL+ A-33
NB
....................................................................................................................................................................................................................................
A-14 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
New installation concept Supplemental Information
Pin assignment of EC The following table shows the connector assignment of the EC
connectors connectors (1 - 4) on the rear side of the module container to a
32-pair AP cable. The AP cable is available in different lengths (see
the Ordering Guide (363-211-144)).
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary A-15
Issue 1, July 2005 See notice on first page
New installation concept Supplemental Information
....................................................................................................................................................................................................................................
A-16 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
New installation concept Supplemental Information
Purpose This procedure is used to install module container with 32-pair cables.
Procedure ............................................................................................................................................................
1 Determine the length of the system cable, cut the cable to the needed
length, strip the insulation (minimum 500 mm), and group the tip/ring
pairs according to the cable coding, see Figure A-8, “Pin assignment
of EC connectors (32-pair) rear side” (A-15).
ca. 500 mm
............................................................................................................................................................
2 Swing out the rear side of the module container vertical to the front
and position and fasten the stripped cable with cable ties to the
module container.
............................................................................................................................................................
3 Position each single wire in the contact guide slot of the upper EC
connector according to the cable coding, see Figure A-8, “Pin
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary A-17
Issue 1, July 2005 See notice on first page
New installation concept Supplemental Information
Installation sequence module container with
32-pair cable
............................................................................................................................................................
4 When the wiring is finished, swing the module container back, place
the excess length of the cables in the cabling area and mount the
module container to the MDF.
............................................................................................................................................................
....................................................................................................................................................................................................................................
A-18 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
New installation concept Supplemental Information
Installation sequence module container with
32-pair cable
............................................................................................................................................................
............................................................................................................................................................
7 Press firmly until the module clicks into the module container. An
audible click confirms that the insertion has been completed
successfully. Position the module downwards for interlocking so that
the front edge is inside of the module container.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary A-19
Issue 1, July 2005 See notice on first page
New installation concept Supplemental Information
Installation sequence module container with
32-pair cable
............................................................................................................................................................
8 Bolt the front brackets on both sides alternately and check the correct
position of the two EC connectors by pushing gently with your hand.
............................................................................................................................................................
............................................................................................................................................................
10 Determine the length of the patch cable, cut the cable and strip the
insulation to the needed length, pass the cable sidewise through the
loop until the cable sheath reaches the EC connector. Position each
single wire in the contact guide slot of the EC connector according to
the relevant module pin assignment, see “a/b Wiring for module
....................................................................................................................................................................................................................................
A-20 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
New installation concept Supplemental Information
Installation sequence module container with
32-pair cable
1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8
a b a b a b a b a b a b a b a b a b a b a b a b a b a b a b a b
w bl w or w s w br w bl w or w s w br w bl w or w s w br w bl w or w s w br
bk bk bk bk bk bk bk bk bk bk bk bk bk bk bk bk
............................................................................................................................................................
END OF STEPS
..............................................................................................................................................................................
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary A-21
Issue 1, July 2005 See notice on first page
New installation concept Supplemental Information
Procedure ............................................................................................................................................................
............................................................................................................................................................
2 Before removing the wired front bracket, mark their positions to avoid
a later mix-up.
....................................................................................................................................................................................................................................
A-22 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
New installation concept Supplemental Information
Replacement of the modules
............................................................................................................................................................
3 Untighten the screws on both sides of the front bracket alternately and
remove the front bracket together with both EC connectors by pulling
forward.
............................................................................................................................................................
5 Check unlocked position (left and right) and pull out the module in
the unlocked position uniformly.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary A-23
Issue 1, July 2005 See notice on first page
New installation concept Supplemental Information
Replacement of the modules
............................................................................................................................................................
6 Remove the module completely from the module container and store
it in a safe place.
............................................................................................................................................................
7 Insert the new module, for example a splitter module, in the reverse
sequence, as described in “Installation sequence module container
with 32-pair cable” (A-17).
END OF STEPS
..............................................................................................................................................................................
....................................................................................................................................................................................................................................
A-24 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
New installation concept Supplemental Information
Procedure ............................................................................................................................................................
1 Remove the label holder. Before removing the wired front bracket,
mark off their position to avoid a later mix-up, see the figure for an
example.
............................................................................................................................................................
2 Untighten the screws on both sides of the front bracket alternately and
remove the front bracket together with both EC connectors by pulling
forward.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary A-25
Issue 1, July 2005 See notice on first page
New installation concept Supplemental Information
Replacement of the module container
............................................................................................................................................................
3 Place the screwdriver in the bore hole, press back and move the
screwdriver sideways as a lever towards the center of the module
container. Release the mechanical interlock and swing the module
container forward sideways. Note: For module container type A the
steps 3 and 4 are not applicable.
............................................................................................................................................................
....................................................................................................................................................................................................................................
A-26 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
New installation concept Supplemental Information
Replacement of the module container
............................................................................................................................................................
END OF STEPS
..............................................................................................................................................................................
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary A-27
Issue 1, July 2005 See notice on first page
New installation concept Supplemental Information
Purpose This procedure describes how the new installation concept (NIC)
applies for example to the ADSL32 packs LPA432 (POTS over
ADSL) and LPA434 (ADSL over ISDN); for further examples refer to
the Applications and Planning Guide Narrowband and ATM xDSL
services (363-211-586).
MDF MDF
Applicable for LPA43 2 combined with any POTS pack Applicable for LPA434
Assumptions The subscriber loops for the ADSL and NB services are fully
identified. If not, contact the originator of the work order.
All ADSL ports of the ADSL32p packs LPA432 or of the ADSL32i
packs LPA434 will be connected via splitter modules.
....................................................................................................................................................................................................................................
A-28 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
New installation concept Supplemental Information
a/b Wiring for module container on
subscriber side
Module pin assignment The module container consists of the module carrier completely
equipped with modules, EC connectors, and front brackets equipped
with two EC connectors each (see figure below).
The figure below shows the Module pin assignment for POTS APs
LPZ1XY: All POTS APs with 32 subscriber ports may be connected
via connect-through modules to the MDF.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary A-29
Issue 1, July 2005 See notice on first page
New installation concept Supplemental Information
a/b Wiring for module container on
subscriber side
The figure below shows the Module pin assignment for ISDN AP
LPU112 (2B1Q): All ISDN APs may be connected via
connect-through modules to the MDF.
The figure below shows the Module pin assignment for SHDSL AP
LPS510: The LPS510 may be connected via connect-through modules
to the MDF.
The figure below shows the Module pin assignment for HDSL AP
LPS503/LPS504 (2B1Q): The LPS503/LPS504 may be connected via
connect-through modules to the MDF.
....................................................................................................................................................................................................................................
A-30 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
New installation concept Supplemental Information
a/b Wiring for module container on
subscriber side
The figure below shows the Module pin assignment for ISDN AP
LPU112 (2B1Q): All ISDN APs may be connected via
connect-through modules to the MDF.
The figure below shows the Module pin assignment for ADSL AP
LPA417: The LPA417 may be connected via connect-through modules
to the MDF. Cport x means the combination of the ports ADSL x and
ISDN x.
Figure A-20 shows the Module pin assignment for LPA432 (ADSL -
lite): For ADSL-lite the LPA432 may be connected via
connect-through modules to the MDF.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary A-31
Issue 1, July 2005 See notice on first page
New installation concept Supplemental Information
a/b Wiring for module container on
subscriber side
LPA432 may be combined with any POTS AP. Cport x means the
combination of the ports ADSL x and POTS x.
The figure below shows the Module pin assignment for LPA434:
Country-dependent splitter modules may be used. Each LPA434 may
be combined with two LPU430 or external ISDN sources.
Cport x means the combination of the ports ADSL x and ISDN x. For
example, Cport 1 is ADSL 1 combined with ISDN 1, Cport 17 is
ADSL 17 combined with ISDN 17, where ISDN 1 to ISDN 16 belong
to one LPU430, ISDN 17 to ISDN 32 belong to the other LPU430.
The figure below shows the Module pin assignment for SHDSL16 AP
LPS702: The LPS702 may be connected via connect-through modules
to the MDF.
....................................................................................................................................................................................................................................
A-32 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
New installation concept Supplemental Information
Procedure ............................................................................................................................................................
3 Connect the ADSL output of the ADSL AP to the rear side (AP
connection area) of the designated module (splitter module) as shown
in the module pin assignment figures Figure A-12, “Module pin
assignment for POTS APs LPZ1XY” (A-29).
............................................................................................................................................................
5 Repeat step 1. through step 4. for all subscriber loops on the pack.
............................................................................................................................................................
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary A-33
Issue 1, July 2005 See notice on first page
Supplemental Information
OAM&P connections
Overview
....................................................................................................................................................................................................................................
Purpose The following solutions are most commonly used for OAM&P
connections:
• Serial local connection from a PC running the narrowband GSI to
the CIT connector on the CIU, refer to “Serial local connection
for narrowband applications” (A-36).
• LAN connection from a PC running the narrowband GSI only to
the LAN connector on the shelf. The installation procedure for
this solution is provided in “LAN connection for narrowband
applications” (A-37).
• Remote operations channel (ROC) within an E1 feeder This
OAM&P connection type has to be provisioned during system
turnup. It does not require any installation activity and therefore
is not considered in this document.
• Serial connection from a PC running the broadband GSI only to
the CONSOLE connector on the AFM, refer to “Serial local
connection for ATM xDSL applications” (A-40).
• LAN connection from a PC running the ATM xDSL GSI only to
the 10BASE-T connector on the AFM, refer to “LAN connection
for ATM xDSL applications” (A-41).
• ATM Operations Channel within an ATM feeder
This OAM&P connection type has to be provisioned during
system turnup. It does not require any installation activity and
therefore is not considered in this document.
• Using the BB ATM Operations Channel to transport narrowband
OAM&P information, refer to “Using the BB ATM Operations
Channel to transport narrowband OAM&P information” (A-43).
• LAN connection from a PC running the IP GSI to the 10BASE-T
connector, refer to “LAN connection for IP applications” (A-46).
• Inband management channel via IPFM uplinks.
This OAM&P connection type has to be provisioned during
system turnup. It does not require any installation activity and
therefore is not considered in this document.
Contents
Serial local connection for narrowband applications A-36
....................................................................................................................................................................................................................................
A-34 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
OAM&P connections Supplemental Information
Overview
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary A-35
Issue 1, July 2005 See notice on first page
OAM&P connections Supplemental Information
Serial connection from GSI The serial local connection from a PC running the narrowband GSI
to the CIU interface may be connected to the CIT connector on the CIU.
AnyMe- GSI-NB
RS-232C
COM1/
CIU/CIT
For the connection a normal 1:1 RS-232C cable as shown in the table
below must be used (single NE mode without PPP).
Internal cable connections The internal cable connections for connecting the PC GSI locally to
the CIU are:
Table A-5 RS-232C cable: AnyMedia, connector CIT on CIU to PC GSI, COM1/COM2
Male conn. CIT (DCE mode), AnyMedia signal for Wire Female conn. COM1/COM2 (DTE mode) 1
(from female CIT on CIU) RS-232C (from male COM1/2 on PC GSI)
2 RxD / RD (out) 2 3
3 TxD / TD (in) 3 2
4 DTR (in) 4 20
5 Signal Ground 5 7
6 DSR (out) 6 6
7 RTS (in) 7 4
8 CTS (out) 8 5
Notes:
1. Before making the cable the type of connector used must be checked (9-/25-pin, male/female). Depending
on the PC used the connector type can differ from the type stated above. When using PPP or ″Multiple NE
mode″ the bridge DCD-DSR may be required depending on the PC used.
....................................................................................................................................................................................................................................
A-36 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
OAM&P connections Supplemental Information
LAN connectors
Table A-6 LAN connector designation
Shelf LAN connector Pinning described
in
ETSI V5 Shelves J2 “LAN connector
(J2)” (4-44)
LAG 1900 Shelves J104 “LAN connector
(J104)” (4-66)
Cables
Table A-7 LAN cables
Code, length Description Destination 1 Destination 2
ED7C874–31 LAN HUB LAG 1900
G3, 8 ft (2.44 shelves P104
m)
Manufacturing ETSI V5
required shelves J2
Requirements for The following parts are required for manufacturing the LAN cable for
manufacturing LAN cables one ETSI V5 Shelf.
for ETSI V5 Shelves
Table A-8 Requirements for manufacturing LAN cables
Part Description
9-pin D-sub, male, soldering
Connector hood with straight
cable outlet
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary A-37
Issue 1, July 2005 See notice on first page
OAM&P connections Supplemental Information
LAN connection for narrowband
applications
Installing LAN cables The LAN cables should be installed in the following order:
............................................................................................................................................................
1 Locate the first LAN cable for the rack and verify that the customer’s
cable side is equipped with the correct connector matching the
customer’s 10BaseT LAN equipment.
............................................................................................................................................................
2 Label the 9-pin connector with ″P104″ or ″J2″ and mark the RJ45
connector as required.
J2 J104
J2 P104
To LAN
To LAN
............................................................................................................................................................
3 First take the LAN cable for shelf 1 and feed the end with the 9-pin
connector on the right side into the cable duct.
............................................................................................................................................................
4 In height of the connector field on top of the shelf push the connector
through the opening at the left side. Carefully place the cable in the
cable opening so that no cable will be damaged.
....................................................................................................................................................................................................................................
A-38 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
OAM&P connections Supplemental Information
LAN connection for narrowband
applications
............................................................................................................................................................
5 Mate the 9-pin connector with connector J104 (or J2 for the ETSI V5
shelf) on the connector field of the shelf and secure. Add cable ties as
needed.
............................................................................................................................................................
6 Attach the LAN cable with cable ties to the recently installed E1
cables.
............................................................................................................................................................
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary A-39
Issue 1, July 2005 See notice on first page
OAM&P connections Supplemental Information
Serial connection from GSI The serial local connection from a PC running the ATM xDSL GSI
to the serial AFM interface may be connected to the CONSOLE connector on the AFM faceplate.
For the connection a 1:1 RS-232C cable as shown in the previous
table must be used. The use of shielded cable is recommended.
Internal cable connections Internal cable connections for connecting the PC GSI directly to the
AFM packs are:
Table A-9 RS-232C cable: Connector CONSOLE on AFM packs to PC GSI, COM1/COM2
Male conn. CONSOLE (DCE AnyMedia signal for Female conn. COM1/COM2 (DTE mode) 1
mode), (from female CONSOLE on RS-232C (from male COM1/2 on PC GSI for ATM xDSL
AFM pack) applications)
3 TxD / TD (in) 3 2
4 DTR (in) 4 20
5 Signal Ground 5 7
6 DSR (out) 6 6
7 RTS (in) 7 4
8 CTS (out) 8 5
9 not used (RI) 22 not used
Notes:
1. Before making the cable the type of connector used must be checked (9-/25-pin, male/female).
....................................................................................................................................................................................................................................
A-40 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
OAM&P connections Supplemental Information
LAN connection from GSI The connector 10BASE-T on the AFM faceplate is used for
to the 10BASE-T connector connecting the Ethernet interface of the PC card to the Ethernet
on AFM interface on the AFM packs. It is assumed that the PC GSI is running
the GSI BB software for ATM xDSL applications.
Crossover wiring for LAN For example, the crossover cable connections for the LAN
point-topoint point-to-point connection with an RJ45 connector are:
Table A-10 External Ethernet cable: 10BASE-T on AFM pack to PC GSI directly (crossover
wiring for LAN point-to-point connection)
Male conn. 8-pin RJ45, AnyMedia signal Wire 1 Male conn. 8-pin RJ45 (from PC GSI signal
(from female 10BASE-T on female RJ45 connector of
AFM pack) LAN card, PC GSI)
5
6 Receive Data - (in) 2 Transmit Data - (out)
Notes:
1. Dependent on cable used.
Straight-through wiring For example, the straight-through cable connections via the customer’s
10BaseT Ethernet equipment (e.g. mini hub) for the LAN
point-to-point connection to an RJ45 connector are:
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary A-41
Issue 1, July 2005 See notice on first page
OAM&P connections Supplemental Information
LAN connection for ATM xDSL
applications
Table A-11 External Ethernet cable: 10BASE-T on AFM pack to customer’s 10BaseT LAN
equipment (straight-through)
Male conn. 8-pin RJ45, AnyMedia signal Wire 1 Male conn. 8-pin RJ45 (from Signal of customer’s
(from female 10BASE-T on female RJ45 connector of LAN 10BaseT equipment
AFM pack) card, PC GSI)
5
6 Receive Data - (in) 6 Receive Data - (in)
Notes:
1. Dependent on cable used.
....................................................................................................................................................................................................................................
A-42 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
OAM&P connections Supplemental Information
LAN
OAM&P information for
narrowband passes
through backplane
COMDAC
10BaseT port
Rx and Tx port
for feeder cable
Cabling The 10BASE-T connector (LAN port) of the AFM pack has to be
connected to the LAN port of the same shelf. The table below shows
the required connections, depending on the shelf type.
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary A-43
Issue 1, July 2005 See notice on first page
OAM&P connections Supplemental Information
Using the BB ATM Operations Channel to
transport narrowband OAM&P information
Notes:
1. When two AFMs are installed, special duplex cabling is required as described below.
Cabling for duplex mode Special duplex cabling is required when two AFMs are installed.
For establishing a connection between the 10BaseT ports on both
AFMs in duplex AFM mode and the LAN port on the shelf construct
a special Y assembly as described below:
• Obtain a commercially available ″straight-through″ wired RJ45
3-fold coupler (e.g. TA315-4 from ARP Datacon).
• Connect 2 commercially available ″straight through″ 10BaseT
cables (Pin 1 to Pin 1, Pin 2 to Pin 2, and so on, male DB-9
connector on one end, female DB-9 connector on the other end)
to two of the split-out jacks of the RJ45 3-fold coupler.
• Connect the orderable LAN cable ED7C829-32 Gr6 or
ED7C829-32 Gr6A with the RJ45 plug to the third split-out jack
of the RJ45 3-fold coupler.
....................................................................................................................................................................................................................................
A-44 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
OAM&P connections Supplemental Information
Using the BB ATM Operations Channel to
transport narrowband OAM&P information
The signals and pins of this Y-assembly with RJ-45 plug connectors
on all three ends and wired “cross over” is shown in table below.
Table A-13 Pin assignment of Y-assembly
End A (AFM 1) End B (AFM 2) End C (Shelf/ CIU/ COMDAC)
RJ-45 Pin Signal RJ-45 Pin Signal LAN Signal
connector
J2 or J107
1 Transmit Data + 1 Transmit Data + 1 Receive Data +
2 Transmit Data - 2 Transmit Data - 6 Receive Data -
3 Receive Data + 3 Receive Data + 2 Transmit Data +
6 Receive Data - 6 Receive Data - 7 Transmit Data -
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary A-45
Issue 1, July 2005 See notice on first page
OAM&P connections Supplemental Information
....................................................................................................................................................................................................................................
A-46 Lucent Technologies - Proprietary 363-211-603
See notice on first page Issue 1, July 2005
Glossary
A ACP
Alarm Connection Panel
ADSL
Asymmetric Digital Subscriber Line
AFM
ATM Feeder Multiplexer
AFMDS3
ATM Feeder Multiplexer (45 Mbit/s)
AFME1
ATM Feeder Multiplexer for E1
AFME3
ATM Feeder Multiplexer (34 Mbit/s)
AFMO
Optical ATM Feeder Multiplexer
ALS
Automatic Laser Shutdown
AP
Application Pack
ATM
Asynchronous Transfer Mode
AWG
American Wire Gauge
....................................................................................................................................................................................................................................
B BER
Bit Error Rate
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary G L O S S A R Y
Issue 1, July 2005 See notice on first page G L - 1
BNC
Bayonet Navy Connector
....................................................................................................................................................................................................................................
C CDF
Clock Distribution Field
CIT
Craft Interface Terminal
CIU
Communication Interface Unit
COMDAC
Common Data and Control
CP
Circuit Pack
....................................................................................................................................................................................................................................
D DDF
Digital Distribution Frame
DOTS
Digital Office Timing Supply
DSL
Digital Subscriber Line
....................................................................................................................................................................................................................................
E EMC
Electro-Magnetic Compatibility
ESD
Electrostatic Discharge
ETSI
European Telecommunications Standards Institute
....................................................................................................................................................................................................................................
F FE
Fast Ethernet
FFCU
Fan Filter and Clock Distribution Unit
....................................................................................................................................................................................................................................
G L O S S A R Y Lucent Technologies - Proprietary 363-211-603
G L - 2 See notice on first page Issue 1, July 2005
....................................................................................................................................................................................................................................
G GBIC
Gigabit Interface Converter
GPB
General Purpose Block
GSI
Graphical System Interface
....................................................................................................................................................................................................................................
H HDSL
High bit rate Digital Subscriber Line
....................................................................................................................................................................................................................................
I IP&T
Information Products and Training
ISDN
Integrated Services Digital Network
ITU
International Telecommunication Union
....................................................................................................................................................................................................................................
L LAN
Local Area Network
....................................................................................................................................................................................................................................
M MDF
Main Distribution Frame
Mesh-BN
Mesh Bonding Network
Mesh-IBN
Mesh Isolated Bonding Network
....................................................................................................................................................................................................................................
N NAM
Navis ® AnyMedia ® Element Management
NE
Network Element
NIC
New Installation Concept
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary G L O S S A R Y
Issue 1, July 2005 See notice on first page G L - 3
....................................................................................................................................................................................................................................
O OAP
Optical Application Pack
OC
Optical Carrier
OCP
Optical Controller Pack
ONU
Optical Network Unit
....................................................................................................................................................................................................................................
P PCD
Passive Clock Distribution
POTS
Plain Old Telephone Service
....................................................................................................................................................................................................................................
R RCP
Rack Connection Panel
RFCP
Subrack for Fuse Panel and Connection panel
RFP
Rack Fuse Panel
RGU
Ringing Generator Unit
ROC
Remote Operations Channel
RTU
Remote Test Unit
....................................................................................................................................................................................................................................
S SCP
Shelf Connection Panel
SDH
Synchronous Digital Hierarchy
SDSL
Symmetric Digital Subscriber Line
....................................................................................................................................................................................................................................
G L O S S A R Y Lucent Technologies - Proprietary 363-211-603
G L - 4 See notice on first page Issue 1, July 2005
STM
Synchronous Transport Module
....................................................................................................................................................................................................................................
T TAP
Test Access Path
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary G L O S S A R Y
Issue 1, July 2005 See notice on first page G L - 5
Index
A a/b- cables LAN cable (ETSI V5), LAG 1900 Shelf, 2-11
4-44
Installing, 5-42 Clock cable
LAN cable (LAG 1900),
ADSL-cables Installing, 5-87, 5-92
4-66
Installing, 5-44, 5-49 Clock connectors (LAG
Power cables (LAG
1900)
Alarm Connection Panel 1900), 4-56
(ACP520), 4-24 Available cables, 5-92
Ringing cables (LAG
Alarm connectors (ETSI 1900), 4-77 Cable specification,
V5) 4-74
RTU cable (ETSI V5),
Available cables, 4-48 4-45 Pin assignment, 4-73
Pin assignment, 4-47 RTU cable (LAG 1900), Conventions, xxviii
4-68 ........................................................
Alarm connectors (LAG
1900) TAP cables (ETSI V5),
D DC power connections,
4-42
Available cables, 4-72 1-14
Cable specification, TAP cables (LAG
Documentation set, xxix
4-71 1900), 4-64
........................................................
Cabling
Pin assignment, 4-70
........................................................ E E1 cables
Alarm cables, 4-10,
4-24 Installing, 5-32, 5-35,
C Cabeling 5-38
Alarm Connection Panel
Internal cables, 3-36 (ACP), 4-24 E1 connectors (ETSI V5)
Cables ETSI V5 Shelf, 4-28 Available cables, 5-51
Alarm cables (ETSI Power cables, 4-15 Cable specification,
V5), 4-48 4-38
Power cables (RFCP),
Alarm cables (LAG 4-5 Pin assignment, 4-32
1900), 4-71
Rack connection panel E1 connectors (LAG 1900)
Clock cables (LAG for alarming, 4-10
Cable specification,
1900), 4-74
Ringing distribution, 4-60
E1 cables (ETSI V5), 4-7, 4-18
Pin assignment, 4-58
4-38
Clock
E1 feeder cables
E1 cables (LAG 1900),
ETSI V5 Shelf, 2-11
4-60 Installing, 5-51
....................................................................................................................................................................................................................................
363-211-603 Lucent Technologies - Proprietary I N D E X
Issue 1, July 2005 See notice on first page I N - 1
E1 jumper setting, 4-38 Floor mounting Jumpers, 5-128
(Standard), 3-5 ........................................................
E3/DS3 cables
Floor mounting
Installing, 5-9 K Kits, 2-3
earthquake 4, 3-8
........................................................
E3/DS3 feeder cables
Grounding, 3-27
Installing, 5-12, 5-15, L LAG 1900 Shelf
Line-up rack adapter
5-19, 5-24
kit, 3-17 Alarm cables, 4-71
Electrostatic discharge
Optical cable duct, 3-25 Alarm connectors, 4-70
considerations, 1-10
Wall mounting, 3-11 Clock, 2-11
EMC, 1-13
........................................................
Clock cables, 4-74
EMC-compliant
installation, 1-13 F Fan connector (LAG 1900) Clock connectors, 4-73
ESD, 1-10 Pin assignment, 4-78 E1 cables, 4-60
ETSI V5 Shelf Fan Filter and Clock E1 connectors, 4-58
Alarm cables, 4-48 Distribution Unit (FFCU),
Fan connector, 4-78
4-8
Alarm connectors, 4-47 LAN cable, 4-66
FFCU
Clock, 2-11 LAN connector, 4-66
Fan Filter and Clock
E1 cables, 4-38 Distribution Unit, 4-8 Layout, 2-9
E1 connectors, 4-32 Fiber cables Mandatory equipment,
LAN cable, 4-44 2-9
Installing, 5-54, 5-59,
LAN connector, 4-44 5-64, 5-69, 5-74 Mounting, 3-33
Testing procedure, 5-80 Power cables, 4-56
Mandatory equipment,
2-8 ........................................................ Power connectors, 4-56
Mounting, 3-30 G General installation Ringing, 2-10
Power connectors, 4-30 warnings, 1-24 Ringing cables, 4-77
Ringing, 2-10 General wiring warnings, Ringing connector, 4-76
1-27
Ringing connector, 4-52 RTU cable, 4-68
Grounding, 2-10, 3-27,
RTU cable, 4-45 4-16 RTU connector, 4-68
RTU connector, 4-45 RFCP, 4-6 TAP cables, 4-64
Station clock connector, ........................................................ TAP connector, 4-62
4-50
I Timing, 2-11
TAP cables, 4-42
LAN cables
Internal connections
TAP connector, 4-41
Installing, A-37
RCP, 4-133
Timing, 2-11
RFCP, 4-131 LAN connector (ETSI V5)
ETSI-based rack
IPFM uplink feeders Cable specification,
Back-to-Back rack 4-44
adapter kit, 3-21 Installing, 5-82
Pin assignment, 4-44
........................................................
Celing mounting, 3-14
J Jumper, 4-38, 4-76
....................................................................................................................................................................................................................................
I N D E X Lucent Technologies - Proprietary 363-211-603
I N - 2 See notice on first page Issue 1, July 2005
LAN connector (LAG Ringing connector Ringing
1900) (LAG 1900), 4-76
ETSI V5 Shelf, 2-10
Available cable, 4-67 RTU connector (ETSI
Jumpers, 5-128
V5), 4-45
Cable specification,
LAG 1900 Shelf, 2-10
4-66 RTU connector (LAG
1900), 4-68 Ringing cables
Pin assignment, 4-66
Station clock connector Installing (J1C293B-1),
Laser safety guidelines,
(ETSI V5), 4-50 5-120
1-15
........................................................ TAP connector (ETSI Installing (J1C301B-1),
V5), 4-41 5-124
M Mandatory equipment
TAP connector (LAG Ringing connector (ETSI
ETSI V5 Shelf, 2-8 1900), 4-62 V5)
LAG 1900 Shelf, 2-9 Power connectors (ETSI Pin assignment, 4-52
V5) Pre-installed cables,
Metal radius clip, 5-83
........................................................ Pin assignment, 4-30 4-52
....................................................................................................................................................................................................................................
I N D E X Lucent Technologies - Proprietary 363-211-603
I N - 4 See notice on first page Issue 1, July 2005