You are on page 1of 1

V9

FOUNDATION LOADS GOLD COIN DRYING


Silo: 16,8/19 (Unfactored Loads) PRE--SYM21-01452B

16,800 m

4,785 m

21,710 m

Notice: Loads according our Standard


Please, check with local Code

Code: ANSI/ASAE EP433


Density: 0,834 Tn/m3
Date: 24/03/2021

Hypothesi Seismic Cs Snow Wind Total Load


Load Type

Surface Load at the Bottom of the Silo


due to grain.
- - - 11,66 Tn/m²

Vertical Load per Stiffener due to own


weight(silo and conveying system).
- - - 0,89 Tn

Vertical Load per Stiffener due to grain. - - - 38,49 Tn


Vertical Load per Stiffener due to snow
weight.
- 80 kg/m2 - 0,35 Tn

Vertical Load per Stiffener due to wind. - - 105 kg/m2 2,23 Tn


Vertical Load per Stiffener due to
seismic.
0,140 - - 37,81 Tn
Horizontal Load per Stiffener only due
- - 105 kg/m2 0,77 Tn
to wind.
Horizontal Load per Stiffener only due
0,140 - - 13,72 Tn
to seismic.

Bending Moment due to wind load - - 105 kg/m2 412,39 Tn.m

Bending Moment due to seismic load 0,140 - - 7139,31 Tn.m

Number of Stiffeners evenly distributed around Silo circunference 44