Masterflow 524 Technical Datasheet (Brisk)
1 day 32 N/mm²
3 day 43 N/mm²
PREPARATION:
28 days 60 N/mm² The surface onto which the grout is to be applied should
be scraped to remove laitance and expose aggregate.
Flexural Strength BS 6319 part 3 Do not use bush hammers or similar preparation
28 day >6 N/mm² equipment that can crush the aggregate but leave it in
place. The surface must be free of oil, dust, dirt, paint,
Tensile strength BS 6319 part 7 curing compounds or other contaminants that could
impair adhesion. Soak area to be grouted to minimize
28 day >4 N/mm² absorption. Surfaces should be damp but free of
Water Penetration (mm) DIN 1048 part 5 Nil standing water. Particular attention should be paid to
bolt holes to ensure that these are water-free. Use oil
The technical information and application advice given in this Master Builders Solutions publication are based on the present state of
our best scientific and practical knowledge. As the information herein is of a general nature, no assumption can be made as to a
STATEMENT OF
product's suitability for a particular use or application and no warranty as to its accuracy, reliability or completeness either expressed
RESPONSIBILITY
or implied is given other than those required by law. The user is responsible for checking the suitability of products for their intended
use.
Disclaimer:
In view of widely varying site conditions and fields of application of our All descriptions, drawings, photographs, data, ratios, weights i.e. stated
products, this technical data sheet is meant to provide general herein can be changed without advance notice and do not represent the
application guidelines only. This information is based on our present condition of the product as stipulated by contract. It is the sole
knowledge and experience. The customer is not released from the responsibility of the recipient of our products to observe possible
obligation to conduct careful testing of suitability and possible proprietary rights as well as existing laws and provisions. The reference
application for the intended use. The customer is obliged to contact the of trade names of other companies is no recommendation and does not
technical help-line for fields of application not expressly stated in the exclude the use of products of similar type. Our information only
technical data sheet under "Fields of Application". Use of the product describes the quality of our products and services and is no warranty.
beyond the fields of application as stated in the technical data sheet Liability is accepted for incomplete or incorrect particulars in our data
without previous consultation with Master Builders Solutions and sheets only in the event of intent or gross negligence, without prejudice
possible resulting damages are in the sole responsibility of the to claims under product liability laws.
customer.