HYCU User Acceptance Test

You might also like

You are on page 1of 16

v1.

0 - UAT

HYCU (with Exagrid) User Acceptance Test –


Intended Audience

This document includes test cases to verify HYCU and Exagrid backup solution functionality. The test
cases are developed in accordance to design specification. In summary the test cases are to ensure that
all the related components working in normal working condition before running in the production.

This document specifies the test cases to evaluate HYCU and Exagrid products installation and 2
configuration. These tests need to be performed to verify that the device is installed and configured
properly.

Nutanix Cluster Details

Cluster Name: Edaran-NTNX

AOS: 5.1.1.2

Hypervisor: AHV

HYCU Details

HYCU Version: 4.0.3

License:

Hostname: HYCU

IP address & Netmask: 10.1.1.217/24

Gateway: 10.1.1.240

DNS: 10.1.1.5

HYCU Web Console UI login:

https://10.1.1.217:8443/console

Username: admin

Password: admin

HYCU cli:

Login as: admin

Password: admin

Cloud Vision Technology: HYCU (with Exagrid) User Acceptan


Exagrid Details

Exagrid Model: EX13000E

Site Name: HQ
3
ExaGrid Server Name: EX01

Installed Version: 5.2.2 P36

IP configurations:
Port IP Address Username Password Remarks
IPMI 10.1.1.216 ADMIN ADMIN
NIC1 10.1.1.217 admin EdaranITServices
NIC5 10.1.1.218 Admin EdaranITServices
NIC6 10.1.1.219 admin EdaranITServices

Subnet Mask 255.255.255.0


Gateway 10.1.1.240
DNS 10.1.1.5

Exagrid Web Console UI login:

Accessible via web browser with the address of: http://NIC5_IP or http://NIC6_IP

Username: admin Username: support

Password: EdaranITServices Password:

Cloud Vision Technology: HYCU (with Exagrid) User Acceptance Test | 3 


Test Plan

The test scenarios for the UAT are described as follows

1. Functionality Testing : Verify the ease of use and usability of HYCU Dashboard
4
a. From home dashboard show monitoring status of HYCU widget; Backup policies, Virtual

Machine protection status, Applications protection status, and Backups, Jobs, and Event

status.

b. Able to auto-discover VM once Nutanix cluster is declared in HYCU UI

c. Able to auto-detect running application on VMs

d. Rolling Upgrade of HYCU software

2. Functionality Testing: Verify HYCU and Exagrid ease of configuration

a. HYCU: Able to configure Backup Policy (CRUD)

i. Backup Schedule (RPO and RTO)

ii. Backup Retention

iii. Archiving

iv. Fast Restore

v. Backup Window

b. Exagrid: Able to configure Exagrid share as backup target (CRUD)

c. HYCU: Able to configure Backup Target (CRUD)

d. HYCU: Able to configure Credential Group (CRUD)

e. HYCU: Able to perform VM manual backup

Cloud Vision Technology: HYCU (with Exagrid) User Acceptance Test | 4 


3. Functionality Testing: Verify HYCU ability to Backup and Restore

a. Able to backup VM

b. Able to restore
5
i. VM’s file restoration / application restoration (if applicable for application)

ii. VM restoration

- Restore existing VM (Original VM will be deleted)

- Restore as a clone VM

- Restore VM Disk Files

4. Availability Testing: Exagrid Power Supply Failure

i. Remove power cord for top Power Supply

ii. Verify that alert has been generated and received

iii. Reinstall power cord

iv. Repeat for bottom Power Supply (optional)

Cloud Vision Technology: HYCU (with Exagrid) User Acceptance Test | 5 


Test Case 1 Acceptance Criteria

Verify the ease of use and usability of HYCU Pass ( ) Fail ( ) Partial ( ) N/A ( )
Dashboard
6
Test Duration: 20 minutes

Test Description: To verify the ease of use and usability of HYCU Dashboard

Test Procedures: Access and verify all HYCU UI dashboard functionality and configurations setting.

Expected Result: HYCU UI dashboard is accessible, functional, and configurable. Able to auto-discover VM
once Nutanix cluster is declared in HYCU UI. Able to auto-detect running application on VMs.

Comments:

Customer Note:

Cloud Vision Technology: HYCU (with Exagrid) User Acceptance Test | 6 


Test Case 2a Acceptance Criteria

HYCU Backup Policy configuration Pass ( ) Fail ( ) Partial ( ) N/A ( )

Test Duration: 5 minutes


7

Test Description: To configure Backup Policy (CRUD)

Test Procedures: Use HYCU UI to configure Backup Policy (CRUD)

Expected Result: Able to configure Backup Policy (CRUD) with functions below:-

i. Backup Schedule (RPO and RTO)

ii. Backup Retention

iii. Archiving

iv. Fast Restore

v. Backup Window

Comments:

Customer Note:

Cloud Vision Technology: HYCU (with Exagrid) User Acceptance Test | 7 


Test Case 2b Acceptance Criteria

HYCU Backup Target configuration Pass ( ) Fail ( ) Partial ( ) N/A ( )

Test Duration: 5 minutes


8

Test Description: To configure Exagrid share as backup target (CRUD)

Test Procedures: Use Exagrid UI to configure Exagrid share as backup target (CRUD)

Expected Result: Able to configure Exagrid share as backup target (CRUD)

Comments:

Customer Note:

Cloud Vision Technology: HYCU (with Exagrid) User Acceptance Test | 8 


Test Case 2c Acceptance Criteria

HYCU Backup Target configuration Pass ( ) Fail ( ) Partial ( ) N/A ( )

9
Test Duration: 2 minutes

Test Description: To configure Backup Target (CRUD) for HYCU protected VM(s)

Test Procedures: Use HYCU UI to configure Backup Target (CRUD)

Expected Result: Able to configure Backup Target (CRUD)

Comments:

Customer Note:

Cloud Vision Technology: HYCU (with Exagrid) User Acceptance Test | 9 


Test Case 2d Acceptance Criteria

HYCU Credential Group configuration Pass ( ) Fail ( ) Partial ( ) N/A ( )

1
Test Duration: 2 minutes 0

Test Description: to configure Credential Group (CRUD)

Test Procedures: Use HYCU UI to configure Credential Group (CRUD)

Expected Result: Able to configure Credential Group (CRUD)

Comments:

Customer Note:

Cloud Vision Technology: HYCU (with Exagrid) User Acceptance Test | 10 
Test Case 2e Acceptance Criteria

Performing manual VM backup via HYCU UI Pass ( ) Fail ( ) Partial ( ) N/A ( )

1
Test Duration: 5 minutes 1

Test Description: To perform manual VM backup via HYCU UI

Test Procedures: Use HYCU UI to perform manual VM backup

Expected Result: Manual VM backup is performed. Able to find the restore point for the manual backed up
VM

Comments:

Customer Note:

Cloud Vision Technology: HYCU (with Exagrid) User Acceptance Test | 11 
Test Case 3a Acceptance Criteria

HYCU VM Backup Pass ( ) Fail ( ) Partial ( ) N/A ( )

Test Duration: 15 minutes


1
2
Test Description: To verify HYCU ability to backup Nutanix VM(s)

Test Procedures: Verify if VMs are backed up according to the assigned backup policy and restore point(s)
availability

Expected Result: VM(s) are backed up according to the assigned backup policy and restore point(s)
availability

Comments:

Customer Note:

Cloud Vision Technology: HYCU (with Exagrid) User Acceptance Test | 12 
Test Case 3b-i Acceptance Criteria

HYCU VM’s File Level Restoration Pass ( ) Fail ( ) Partial ( ) N/A ( )

Test Duration: 15 minutes


1
3
Test Description: To verify HYCU ability to restore Nutanix VM’s file and application

Test Procedures: Verify if VM able to be restored according to the below criteria:-

i. VM’s file restoration

ii. VM’s application restoration (if applicable)

Expected Result: Able to restore VM’s file and application

Comments:

Customer Note:

Cloud Vision Technology: HYCU (with Exagrid) User Acceptance Test | 13 
Test Case 3b-ii Acceptance Criteria

HYCU VM Restoration (Whole VM) Pass ( ) Fail ( ) Partial ( ) N/A ( )

Test Duration: 30 minutes


1
4
Test Description: To verify HYCU ability to restore Nutanix VM

Test Procedures: Verify if VMs able to be restored according to the below criteria:-

- Restore existing VM (Original VM will be deleted)

- Restore as a clone VM

- Restore VM Disk Files

Expected Result: VM(s) able to be restored with all of the above criteria

Comments:

Customer Note:

Cloud Vision Technology: HYCU (with Exagrid) User Acceptance Test | 14 
Test Case 4 Acceptance Criteria

Power Supply Failure Test. Running on 1 Pass ( ) Fail ( ) Partial ( ) N/A ( )


power supply.
1
Test Duration: 2 minutes
5

Test Description: To verify Exagrid appliance is still running even when 1 unit power supply failed

Test Procedures: Disconnect power cord from one of the power supply, verify alert and reconnect power
cord.

Expected Result: Exagrid appliance runs fine without power disruption

Comments:

Customer Note:

Cloud Vision Technology: HYCU (with Exagrid) User Acceptance Test | 15 
Document Sign Off

Comments, if any:
1
____________________________________________________________________________________
6
____________________________________________________________________________________

This is to certify that the above installation and acceptance test has been completed successfully.

Tested by Verified by

Signature: Signature:

Name: Name:

Designation: System Engineer, Cloud Vision Designation:

Date: Date:

Cloud Vision Representative Customer Representative

Cloud Vision Technology: HYCU (with Exagrid) User Acceptance Test | 16 

You might also like