General Notes

A GENERAL E5 JOIST AND RAFTER CONSTRUCTION SPANNING OVER 8'-0" MUST HAVE CROSS-BRIDGING OR SOLID BLOCKING AT THE CENTER OF THE G STRUCTURAL DESIGN LOADS
A1 STRUCTURAL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE MASSACHUSETTS BUILDING CODE, NINTH EDITION AND THE INTERNATIONAL SPAN. 100 G1 DEAD
BUILDING CODE, 2015. LOADS
E6 JOIST SUPPORT BY NAILING IS FORBIDDEN UNLESS USED WITH AN APPROVED HANGER.
A2 VERIFY AND COORDINATE ALL NEW AND EXISTING DIMENSIONS RELATED TO THIS PROJECT. 101 (A) WEIGHT OF BUILDING COMPONENTS AS REQUIRED
E7 MINIMUM BEARING FOR ALL JOISTS AND RAFTERS SHALL BE 4".
A3 TYPICAL DETAILS AND NOTES SHOWN ON STRUCTURAL DRAWINGS SHALL BE APPLICABLE TO ALL PARTS OF THE STRUCTURAL WORK EXCEPT WHERE 103 (B) ROOFING ALLOWANCE 30 PSF
SPECIFICALLY REQUIRED OTHERWISE BY CONTRACT DOCUMENTS. E8 PARTITION AND OUTSIDE STUD WALLS SHALL BE BRIDGED ONCE IN THEIR STORY HEIGHT OR AT LEAST EVERY 4'-6". 104 (C) HUNG ALLOWANCE 10 PSF
A4 DETAILS NOT SPECIFICALLY SHOWN SHALL BE SIMILAR TO THOSE SHOWN FOR THE MOST NEARLY SIMILAR CONDITION AS DETERMINED BY THE ARCHITECT. E9 ANCHOR BOLTS AND BOLTS FOR STRUCTURAL TIMBER SHALL BE ASTM A 307. STANDARD CUT WASHERS SHALL BE PROVIDED BETWEEN 200 G2 LIVE
A5 IF IN THE COURSE OF EXECUTION OF THE STRUCTURAL WORK, ANY PORTION OF THE COMPLETED STRUCTURE DOES NOT MEET THE REQUIREMENTS OF THE WOOD AND BOLT HEAD AND BETWEEN WOOD AND BOLT NUT UNLESS STEEL PLATES OR PLATE WASHERS ARE USED. LOADS
CONTRACT DOCUMENTS AS DETERMINED BY THE ARCHITECT, THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE DESIGN AND IMPLEMENTATION OF E10 INTERIOR PARTITIONS SHALL BE FRAMED WITH 2X4's AT 16" C/C (UNLESS NOTED ON THE PLANS). 201 (A) OCCUPANCY CATEGORY II
REMEDIAL ACTION TO ENSURE THAT THE COMPLETED WORK IS IN CONFORMANCE WITH THE CONTRACT DOCUMENTS. A DESCRIPTION OF THE 202 (B) STORAGE (LIGHT) 125 PSF
NON-CONFORMING WORK SHALL BE SUBMITTED ALONG WITH THE PROPOSED REMEDIAL ACTION TO THE ARCHITECT FOR REVIEW AND APPROVAL PRIOR TO
E11 ALL DOOR AND WINDOW LINTELS SHALL BE A MINIMUM OF 2X6's (UNLESS NOTED OTHERWISE ON THE PLANS).
203 (C) TYPICAL OFFICE FLOOR CORRIDORS 80 PSF
IMPLEMENTATION. E12 NO JOIST SHALL BE NOTED OR DRILLED WITH HOLES WITHOUT THE SPECIFIC APPROVAL OF THE ENGINEER.
204 (D) PARTITION ALLOWANCE 20 PSF
A6 THE BASE BUILDING STRUCTURE WAS DESIGNED TO RESIST THE LOADS DESCRIBED IN GENERAL NOTES SECTION ******DESIGN LOAD SECTION****** IN THE E13 NO JOIST SHALL BE REPAIRED OR REINFORCED IN ANY WAY WITHOUT THE SPECIFIC APPROVAL OF THE ENGINEER.
COMPLETED CONDITION OF THE PROJECT. DURING CONSTRUCTION THE CONTRACTOR IS RESPONSIBLE TO VERIFY THE CAPACITY OF THE PARTIALLY 205 (E) MECHANICAL EQUIPMENT ROOM 150 PSF OR EQUIP WT
E14 BEAMS BUILT UP OF TIMBERS SHALL BE FIRMLY NAILED OR BOLTED TOGETHER. 206 G2 (F) CATWALKS 40 PSF OR 300 LB CONC
COMPLETED STRUCTURE TO RESIST LOADS DUE TO TEMPORARY CONDITIONS, CONSTRUCTION EQUIPMENT, STORED MATERIALS, SHORING, ETC.
A7 THE CONTRACTOR SHALL SUBMIT COMPLETE SHOP DRAWINGS FOR ALL PARTS OF THE WORK, INCLUDING DESCRIPTION OF DEMOLITION, AND
E15 PLYWOOD SHALL BE LAID WITH FACE GRAIN PARALLEL TO SPAN; STAGGER ALL JOINTS. 300 G3 SNOW
CONSTRUCTION METHODS AND SEQUENCING WHERE APPLICABLE. NO PERFORMANCE OF THE WORK INCLUDING, BUT NOT LIMITED TO, DEMOLITION OF E16 SILLS SHALL BE 2-2X6 (PRESSURE-TREATED) AND SHALL BE ANCHORED WITH 5/8" DIAMETER BY 1'-6" LONG ANCHOR BOLTS NOT MORE LOADS
EXISTING STRUCTURE, OR FABRICATION OR ERECTION OF NEW STRUCTURAL ELEMENTS, SHALL COMMENCE WITHOUT REVIEW OF THE SHOP DRAWINGS BY THAN 4'-0" OC AND AT EACH CORNER UNO. 301 (A) GROUND SNOW LOAD 30 PSF
THE ARCHITECT. E17 TEMPORARY ERECTION BRACING SHALL BE PROVIDED TO HOLD STRUCTURAL TIMBER SECURELY IN POSITION AS DESCRIBED ON THE 302 (B) IMPORTANCE FACTOR (Is) 1.0
A8 INFORMATION REGARDING EXISTING CONSTRUCTION IS BASED UPON AVAILABLE CONSTRUCTION DOCUMENTS PREPARED BY THE ARCHITECT, WHICH MAY DRAWINGS. IT SHALL NOT BE REMOVED UNTIL PERMANENT BRACING HAS BEEN INSTALLED. 303 (C) EXPOSURE FACTOR (Ce) 1.1
OR MAY NOT REFLECT ALL AS BUILT CONDITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES DISCOVERED DURING THE COURSE OF CONSTRUCTION BEFORE 304 (D) THERMAL FACTOR (Ct) 1.0
PROCEEDING WITH WORK IN THE AREA. E18 TIMBER SHALL BE GENERALLY KNOT-FREE, WITH ONLY SMALL TIGHT KNOTS PERMITTED AND GENERALLY STRAIGHT-GRAINED.
305 (E) ROOF SNOW LOAD 35 PSF + DRIFT
A9 UNLESS OTHERWISE SPECIFICALLY STATED IN WRITING, MARK-UPS ON REVIEWED OR APPROVED SHOP DRAWINGS OR SIMILAR SUBMISSIONS ARE TO E19 STRUCTURAL TIMBER SHALL BE INDENTIFIED BY THE GRADE MARK OF OR CERTIFICATE OF INSPECTION ISSUED BY A GRADING OR
400 G4 WIND
COMMUNICATE AND CONFIRM THE INTENT OF CONTRACT DOCUMENTS AND SHALL NOT BE CONSTRUED AS AUTHORIZING OR REQUESTING A CHANGE TO INSPECTION BUREAU OR AGENCY RECOGNIZED AS BEING COMPETENT.
LOADS
ANY CONTRACT PRICE. IF A FABRICATOR OR CONTRACTOR BELIEVES THAT A CHANGE TO ANY CONTRACT PRICE SHOULD BE MADE, A WRITTEN REQUEST E20 STRUCTURAL TIMBER SHALL BE VISUALLY STRESS-GRADED LUMBER IN ACCORDANCE WITH THE PROVISIONS OF ASTM DESIGNATION 401 (A) BASIC WIND SPEED 140 MPH
SHALL BE SUBMITTED FOR A RECOMMENDATION BY THE ARCHITECT AND ACTION BY THE OWNER ALONG WITH A COST PROPOSAL FOR ANY PROPOSED D245-74, "METHODS FOR ESTABLISHING STRUCTURAL GRADES AND RELATED ALLOWABLE PROPERTIES FOR VISUALLY GRADED LUMBER."
CHANGE PRIOR TO FABRICATION OR INSTALLATION OF ANY ITEM FOR WHICH A CHANGE IN CONTRACT PRICE IS REQUESTED. ANY CLAIM FOR ADDITIONAL 402 (B) IMPORTANCE FACTOR (Iw) 1.0
COMPENSATION FOR AN ITEM FABRICATED OR INSTALLED WITHOUT PRIOR WRITTEN APPROVAL OF A CHANGE IN CONTRACT PRICE FOR SUCH FABRICATION E21 TIMBER SHALL BE SO HANDLED AND COVERED AS TO PREVENT MARRING AND MOISTURE ABSORPTION FROM SNOW OR RAIN. 403 (C) EXPOSURE CATEGORY B
AND/OR INSTALLATION WILL NOT BE ALLOWED. 404 (D) VELOCITY PRESSURE COEFFICIENT (Kh) ROOF XX
405 (E) DIRECTIONALITY FACTOR (Kd) XX
406 (F) TOPOGRAPHIC FACTOR (Kzt) XX
B FOUNDATIONS
407 (G) GUST FACTOR (G) – SHORT DIRECTION XX
B1 FOUNDATIONS FOR THIS PROJECT CONSIST OF ISOLATED COLUMN FOOTINGS AND EXISTING WALL FOUNDATIONS.
408 (H) GUST FACTOR (G) – LONG DIRECTION XX
B2 FOUNDATION UNITS SHALL BE CENTERED UNDER SUPPORTED STRUCTURAL MEMBERS, UNLESS NOTED OTHERWISE ON THE DRAWINGS.
409 (I) EXTERNAL PRESSURE COEFFICIENT (Cp) (WINDWARD) XX
B3 PROVIDE TEMPORARY OR PERMANENT SUPPORTS, WEATHER SHORING, SHEETING, OR BRACING, SO THAT NO HORIZONTAL MOVEMENT OR VERTICAL
410 (J) EXTERNAL PRESSURE COEFFICIENT (Cp) (LEEWARD) – SHORT DIRECTION XX
SETTLEMENT OCCURS TO EXISTING STRUCTURES, STREETS, SOIL OR UTILITIES ADJACENT TO THE PROJECT SITE.
411 (K) EXTERNAL PRESSURE COEFFICIENT (Cp) (LEEWARD) – LONG DIRECTION XX
B4 BOTTOM 3 INCHES OF EXCAVATIONS SHALL BE FINISHED BY HAND SHOVEL OR SMOOTH-EDGED EXCAVATOR BUCKET. FINAL SUBGRADES SHALL BE FIRM
AND FREE OF LOOSE AND/OR DISTURBED MATERIALS. 412 (L) AVERAGE DESIGN WIND PRESSURE XX PSF
B5 CARRY OUT CONTINUOUS CONTROL OF SURFACE AND SUBSURFACE WATER DURING CONSTRUCTION SUCH THAT FOUNDATION WORK IS DONE IN DRY AND 413 (M) BASE SHEAR DUE TO WIND LOADS XX KIPS (SHORT) / XX KIPS (LONG)
ON UNDISTURBED SUBGRADE MATERIAL. 414 (N) MAIN WIND FORCE RESISTING SYSTEM – SHORT DIRECTION ******USER INPUT******
B6 CARRY OUT CONTINUOUS CONTROL OF SURFACE AND SUBSURFACE WATER UNTIL SUFFICIENT DEAD LOAD HAS ACCUMULATED TO PREVENT FLOTATION OF 415 (O) MAIN WIND FORCE RESISTING SYSTEM – LONG DIRECTION ******USER INPUT******
ANY PART OF THE STRUCTURE. 500 G5 SEISMIC
B7 BACKFILL UNDER ANY PORTION OF THE STRUCTURE SHALL BE COMPACTED IN 6" LIFTS PER SPECIFICATION REQUIREMENTS. LOADS
B8 NO FOUNDATION CONCRETE SHALL BE PLACED IN WATER OR ON FROZEN SUBGRADE MATERIAL. 501 (A) Ss .23
B9 PROTECT IN-PLACE FOUNDATIONS AND SLABS FROM FROST PENETRATION UNTIL THE PROJECT IS COMPLETED. REMOVE FROZEN SUBGRADE MATERIALS 502 (B) S1 .065
AND REPLACE WITH GRANULAR FILL AS NECESSARY PRIOR TO PLACING NEW FILL MATERIALS AND/OR PLACING FOUNDATION UNITS. 503 (C) SITE CLASS D (ESTIMATED)
B10 SHEETING, SHORING AND BRACING FOR THE LATERAL SUPPORT OF EXCAVATION SHALL REMAIN IN PLACE UNTIL ALL PERMANENT STRUCTURAL SYSTEMS 504 (D) Sds .245
BELOW GROUND LEVEL ARE COMPLETE. FOR FURTHER INFORMATION ON LATERAL SUPPORT OF EXCAVATION, SEE SPECIFICATIONS. 505 (E) Sd1 .104
B11 NO UTILITIES, PIPES, OR OTHER ELEMENTS SHALL PENETRATE A FOUNDATION ELEMENT EXCEPT AS SPECIFICALLY SHOWN ON THE DRAWINGS. 506 (F) IMPORTANCE FACTOR (Ie) 1.0
B12 WHERE SUITABLE BEARING MATERIAL IS NOT ENCOUNTERED AT THE SPECIFICIED BOTTOM OF FOUNDATION ELEVATION, OVEREXCAVATE TO SUITABLE 507 (G) SEISMIC DESIGN CATEGORY B
MATERIAL AND PLACE LEAN CONCRETE TO THE SPECIFIED BOTTOM OF FOUNDATION ELEVATION. IN ALL INSTANCES, THE SUITABILITY OF THE BEARING 508 (H) BASIC LATERAL FORCE RESISTING SYSTEM – SHORT DIRECTION ******USER INPUT******
MATERIAL SHALL BE DETERMINED BY THE GEOTECHNICAL ENGINEER.
509 (I) BASIC LATERAL FORCE RESISTING SYSTEM – LONG DIRECTION ******USER INPUT******
510 (J) RESPONSE MODIFICATION FACTOR (R) 3.5
C CONCRETE
511 (K) OVERSTRENGTH FACTOR (Ωo) 2.5
C1 CONCRETE WORK SHALL CONFORM TO "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE" (ACI 318-14), AND "SPECIFICATIONS FOR
512 (L) DEFLECTION AMPLIFICATION FACTOR (Cd) 2.25
STRUCTURAL CONCRETE" (ACI 301-05).
513 (M) ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE
C2 CONCRETE SHALL BE CONTROLLED CONCRETE, PROPORTIONED, MIXED, AND PLACED IN THE PRESENCE OF A REPRESENTATIVE OF AN APPROVED TESTING
AGENCY. 514 (N) BUILDNG FUNDAMENTAL PERIOD (T) XX SEC (SHORT) / XX SEC (LONG)
C3 UNLESS NOTED OTHERWISE, CONCRETE SHALL HAVE A MINIMUM 28-DAY COMPRESSIVE STRENGTH AND BE OF A TYPE AS FOLLOWS: 515 (O) BUILDING SEISMIC WEIGHT XX KIPS
516 (P) BASE SHEAR DUE TO SEISMIC LOADS XX KIPS (SHORT) / XX KIPS (LONG)
(A) GENERAL CONCRETE, U.N.O. 4000 PSI (NORMALWEIGHT)
(B) FOOTINGS, PIERS, SLAB ON GRADE 5000 PSI (NORMALWEIGHT)
C4 CONCRETE SHALL BE PLACED WITHOUT HORIZONTAL CONSTRUCTION JOINTS EXCEPT WHERE SHOWN OR NOTED. VERTICAL CONSTRUCTION JOINTS AND
STOPS IN CONCRETE WORK SHALL BE MADE AT MIDSPAN OR AT POINTS OF MINIMUM SHEAR AS DETERMINED BY THE ARCHITECT.
C5 ALLOW ADEQUATE TIME FOR CONCRETE TO CURE AND DRY TO PROPERLY APPLY ALL FINISHES DIRECTLY ADHERED TO FINISHED CONRETE SURFACES.
C6 SIZE OF CONCRETE PLACEMENTS, UNLESS NOTED OTHERWISE, SHALL BE AS FOLLOWS:
C7 MINIMUM OF 72 HOURS SHALL ELAPSE BETWEEN ADJACENT CONCRETE PLACEMENTS. Seal
C8 STRUCTURAL STEEL BELOW GRADE SHALL BE ENCASED IN CONCRETE WITH A MINIMUM COVER OF 2".

D REINFORCEMENT
D1 REINFORCEMENT WORK OF DETAILING, FABRICATION, AND ERECTION SHALL CONFORM TO "BUILDING CODE REQUIREMENTS FOR REINFORCED
CONCRETE" (ACI 318-08), "ACI DETAILING MANUAL - 2004" (SP-66); "CRSI MANUAL OF STANDARD PRACTICE, 28TH EDITION" (2009), AND "STRUCTURAL
WELDING CODE - REINFORCING STEEL" (AWS D1.4-98).
D2 STEEL REINFORCEMENT, UNLESS NOTED OTHERWISE, SHALL CONFORM TO THE FOLLOWING:
Revisions
No. Description Date
(A) STEEL REINFORCEMENT ASTM A615 GRADE 60 (YIELD STRESS 60,000 PSI)
(B) WELDABLE STEEL REINFORCEMENT ASTM A706 GRADE 60 (YIELD STRESS 60,000 PSI)
(C) WELDED WIRE FABRIC (WWF) ASTM A185
(D) EPOXY-COATED STEEL REINFORCEMENT ASTM A775

D3 WHERE REINFORCEMENT IS REQUIRED IN SECTION, REINFORCEMENT IS CONSIDERED TYPICAL WHEREVER THE SECTION APPLIES.
D4 DOWELS SHALL MATCH BAR SIZE AND NUMBER, UNLESS NOTED OTHERWISE.
D5 WHERE CONTINUOUS REINFORCEMENT IS CALLED FOR, IT SHALL BE EXTENDED CONTINUOUSLY AROUND CORNERS AND LAPPED AT NECESSARY SPLICES
OR HOOKED AT DISCONTINUOUS ENDS.
D6 LAPS SHALL BE CLASS B TENSION LAP SPLICES, UNLESS NOTED OTHERWISE.
D7 MINIMUM CONCRETE PROTECTIVE COVERING FOR REINFORCEMENT, UNLESS NOTED OTHERWISE, SHALL BE AS FOLLOWS:

(A) UNFORMED SURFACES CAST AGAINST AND PERMANENTLY IN CONTACT WITH EARTH 3.0"
(B) FORMED SURFACES IN CONTACT WITH EARTH OR EXPOSED TO WEATHER
. #6 THROUGH #18 BARS 2.0"
. #5 BARS, 5/8" DIAMETER WIRES, AND SMALLER 1.5"

D8 REINFORCEMENT SHALL BE CONTINUOUS THROUGH CONSTRUCTION JOINTS.


D9 DOWELS AND OTHER BARS PASSING THROUGH COLD JOINTS OR CONSTRUCTION JOINTS SHALL BE SET PRIOR TO THE INITIAL CONCRETE PLACEMENT.
BARS SHALL NOT BE WET-STUCK IN PLACE AFTER INITIAL CONCRETE PLACEMENT. © 2011 Bohlin Cywinski Jackson
D10 WELDED WIRE FABRIC SHALL LAP 8" OR 1-1/2 SPACES, WHICHEVER IS LARGER, AND SHALL BE WIRED TOGETHER.
D11 INSTALLATION OF REINFORCEMENT SHALL BE COMPLETED AT LEAST 24 HOURS PRIOR TO THE SCHEDULED CONCRETE PLACEMENT. NOTIFY ARCHITECT Owner
OF COMPLETION AT LEAST 24 HOURS PRIOR TO THE SCHEDULED COMPLETION OF THE INSTALLATION OF REINFORCEMENT.

Project Name
E WOOD
E1 TIMBER CONSTRUCTION SHALL CONFORM TO PART II "DESIGN" AS PUBLISHED IN THE "TIMBER CONSTRUCTRION MANUAL" (AITC 6TH Enter address here
EDITION) AND TO "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION" (NF.PA, 2018 EDITION).
E2 NEW TIMBER FOR STRUCTURAL USE SHALL HAVE A MOISTURE CONTENT AS SPECIFIED IN THE "NATIONAL DESIGN SPECIFICATION FOR
WOOD CONSTRUCTION" (NF.PA, 2018 EDITION). Project Status
E3 MATERIAL PROPERTIES FOR TIMBER SHALL CONFORM TO THE FOLLOWING:
E4 "PT" INDICATES PRESSURE-TREATED LUMBER (TO BE USED WHEN IN CONTACT WITH CONCRETE, MASONRY, OR WEATHER).
GENERAL NOTES
(A) FOR MEMBERS WITH NOMINAL 2" THICKNESS. SPRUCE PINE FIR #1/#2 OR BETTER (15% MAX MC)
ALLOWABLE BENDING STRESS:
Fb = 875 PSI (SINGLE MEMBER USE).
ALLOWABLE SHEAR STRESS Fv = 135 PSI
COMPRESSION PARALLEL TO GRAIN = 1150 PSI Scale
COMPRESSION PERPENDICULAR TO GRAIN = 425 PSI
Date Issue Date
MODULUS OF ELASTICITY = 1,400,000 PSI
(B) FOR MEMBERS USED AS BLOCKING. BCJ Project Number Project Number
DOUGLAS-FIR-LARCH #2 OR BETTER (15% MAX MC)
(C) FOR MEMBERS MARKED LVL (MANUFACTURED BY GEORGIA-PACIFIC OR EQUAL)
ALLOWABLE BENDING STRESS Fb = 2900 PSI
ALLOWABLE SHEAR STRESS Fv = 285 PSI
COMPRESSION PARALLEL TO GRAIN = 2600 PSI
COMPRESSION PERPENDICULAR TO GRAIN = 845 PSI

S0.01
12/3/2021 1:19:33 PM

MODULUS OF ELASTICITY = 2,000,000 PSI


General Notes

FACE MOUNT HANGER 14" MAX. NOTES:


TOP MOUNT
1. NO OPENINGS OVER ONE STUD WIDTH TO OCCUR IN WOODSTRUCTURAL PANELS UNLESS DETAILED ON
HANGER HANGER SCHEDULE, UNO ON DRAWINGS STRUCTURAL ELEVATIONS. OPENINGS IN WOOD STRUCTURAL PANEL SHALL BE CUT WITH SABER SAW.
JOIST SIZE HANGER 2. GENERAL CONTRACTOR TO COORDINATE, TYP. U.N.O. ON PLAN

2x6/2x8 SIMPSON U26/ LB28 OR EQUAL


2x10 SIMPSON U210/ LB210 OR EQUAL

14" MAX.
2x12 SIMPSON U210/ LB212 OR EQUAL
1 3/4x5 1/2 LVL HU1.81/5 W/ (16) 0.162x3 1/2 FACE NAILS

DRILL 1"Ø AT
A EDGE NAIL AROUND
OPENING
CORNERS BEFORE 2x OR 3x BLK TYP.
CUTTING OPENINGS
MINOR OPENING
FLOOR GIRDER
16 GA.x 1 1/2"x 2'- 0" 2x OR 3x
2X FLOOR JOISTS STEEL STRAP AT ALL
CORNERS AS SHOWN
NOTE:
1. TOP-OR FACE-MOUNTED HANGER INSTALLEDPER MANUFACTURER'S RECOMMENDATIONS FOR NAILING SCHEDULES FOR MULTIPLE PIECE LVL BEAMS, SEE THE
MANUFACTURER'S RECOMMENDATIONS.
2. GREEN LUMBER FRAMING (WHEN ALLOWED) SHOULD BE INSTALLED WITH THE JOIST SLIGHTLY ABOVE FLOOR BEAM TO ACCOMODATE SHRINKAGE. NOT NECESSARY FOR
ENGINEERED WOOD JOISTS
MECHANICAL DUCT OPENINGS B

1
JOIST MOUNTED FLUSH DETAIL 2
OPENING IN PLYWOOD SHEATHING
N.T.S. N.T.S.

NOTE: NOTE:
DO NOT CUT OR DAMAGE ANY EXISTING JOIST UNLESS SPECIFICALLY SHOWN ON DRAWINGS DETAIL APPLICABLE TO BOTH DIAPHRAGM & SHEARWALL SHEATHINGS
APA PERFORMANCE RATED JOIST - CEILING FLANGE HANGER
SISTER JOIST INTERRUPTED TYPICAL SISTER 2x OR 3x STUD, TYP.
BY MECH DUCT JOIST 3/8" 3/8" AT EDGE OF WSP
EXIST. JOIST
CEILING FLANGE FASTENER
MINIMUM 2 SCREWS "X" NOTE:
CENTERLINE
MECH "X" INDICATES EDGE NAIL SPACING

3/8" 3/8"
FROM FACE 1/2"
DUCT MAXIMUM

REMOVE BRIDGING AS
FLAT BLOCKING
NEEDED TO ACCOMODATE

"X"
AT EDGE OF WSP
UTILITY RUNS. PROVIDE SOLID
BRIDGING ON EITHER SIDE OF
THE BAY FROM WHICH
BRIDGING IS REMOVED. DO
INSTALL PER NFPA 12 WOOD STRUCTURAL PANEL NAILING AT SPLICE A Seal
AND MANUFACTURER'S
NO REMOVE BRIDGING FROM INSTRUCTIONS. STEEL INSTALL PER NFPA 13
WSP JOINT
ADJACENT BAYS IN ANY SPRINKLER SYSTEM AND MANUFACTURER'S
LOCATION. PIPE 4" MAXIMUM DIA. INSTRUCTIONS EDGE NAIL
OF 150 POUNDS MAX.
POINT LOAD
ADDITIONAL SISTER JOISTS 2x OR 3x
TO COMPENSATE FOR TYP.
Revisions
DISPLACED JOIST No. Description Date
PLAN : WOOD STRUCTURAL PANEL ONE SIDE B

3
MECHANICAL DUCT TO WOOD FRAMING COORD 4
WOOD JOIST PIPE HANGER DETAIL 5
WSP/SHEATHING JOINT DETAIL
N.T.S. N.T.S. N.T.S.

1 3/4"
1 3/4"

BEAM HOLE DETAILS

2" MIN
© 2011 Bohlin Cywinski Jackson

NOTES:
Owner
16d (0.162"X3-1/2") NAILS
MINIMUM 2x DIAMETER OF LARGER HOLE 1' - 0" 1. THESE GUIDELINES APPLY TO UNIFORMLY LOADED BEAMS. FOR ALL OTHER APPLICATIONS, SUCH AS 2 ROWS @ 12" OC EACH SIDE
ENGINEERED WOOD PRODUCT BEAMS WITH CONCENTRATED LOADS, PLEASE CONTACT YOUR

3" MIN
TYP ENGINEERED WOOD PRODUCTS DISTRIBUTOR FOR ASSISTANCE. Project Name
2. ROUND HOLES CAN BE DRILLED ANYWHERE IN "AREA A" PROVIDED THAT: NO MORE THAN FOUR
1/3 BEAM DEPTH

HOLES ARE CUT, WITH THE MINIMUM SPACING DESCRIBED IN THE DIAGRAM. THE MAXIMUM HOLE
SIZE IS 1-1/2" FOR DEPTHS UP TO 9-1/4" AND 2" FOR DEPTHS GREATER THAN 9-1/4." Enter address here
AREA B AREA A AREA B 3. RECTANGULAR HOLES ARE NOT ALLOWED.
4. DO NOT DRILL HOLES IN CANTILEVERS WITHOUT PRIOR APPROVAL FROM THE PROJECT DESIGNER.
5. OTHER HOLE SIZES AND CONFIGURATIONS MAY BE POSSIBLE WITH FURTHER ENGINEERING Project Status

3" MIN
16d (0.162"x3-1/2") NAILS
ANALYSIS. FOR MORE INFORMATION, CONTACT YOUR ENGINEERED WOOD PRODUCTS 3 ROWS @ 12" OC
DISTRIBUTOR. 16d (0.162"X3-1/2") NAILS
1/3 SPAN LENGTH 1/3 SPAN LENGTH 1/3 SPAN LENGTH 6. UP TO THREE 3/4" HOLES MAY BE DRILLED IN "AREA B" TO ACCOMMODATE WIRING AND/OR 2 ROWS @ 12" OC EACH SIDE
WATER LINES. THESE HOLES SHALL BE AT LEAST 12" APART. THE HOLES SHALL BE LOCATED IN THE TYPICAL DETAILS
MIDDLE THIRD OF THE DEPTH, OR MINIMUM OF 3" FROM THE BOTTOM AND TOP OF THE BEAM.
FOR BEAMS SHALLOWER THAN 9-1/4", LOCATE HOLES AT MID-DEPTH. 2" MIN
CLEAR SPAN 7. PROTECT PLUMBING HOLES FROM MOISTURE.
8. DETAIL APPLIES TO SIMILAR CONDITIONS WITH STUDS.
Scale As indicated

Date Issue Date


ASSEMBLY A ASSEMBLY B
BCJ Project Number Project Number

S0.02
12/3/2021 1:21:05 PM

6
ALLOWABLE HORIZ. HOLES IN WOOD AND LVL JOIST 7
SISTER JOIST DETAILS
N.T.S. N.T.S.
General Notes

NOTE:
PROVIDE UNDERSLAB DRAINAGE AS SHOWN BELOW SLABS ON GRADE.

#4 x 2'-0" @ 18" OC
DRILL & EPOXY
EXIST SLAB ON GRADE. 6" EMBED
FLOOR
SEE PLANS FOR SUPPORT WWF ON DENSE CONC FLOOR SHEATHING
THICKNESS AND TOP OF BLOCK AT 4'-0" OC EA DIRECTION JOIST/TRUSS
SLAB ELEVATION. NEW CONC SLAB TO MATCH
EXIST THICKNESS CONT CONTRACTION JOINT WWF TO BE CONT
1/8"x1-1/2" GALV STEEL THROUGH CONST JOINT KING STUD TYPICAL STUDS
PARTING PL OR SAW CUT CRIPPLE
STUD

D/3
2" TYP
CONSTRUCTION JOINT (CJ)
HEADER

D
1 STUD SEE
1 PLAN

2" RIGID INSULATION VAPOR RETARDER


BACKFILL & AT ALL INTERIOR
COMPACT SLABS ON GRADE
MIN 8" THK CRUSHED STONE JACK STUDS
95% COMPACTION

1
SLAB ON GRADE INFILL 2
SLAB ON GRADE 3
TYP JACK STUD
N.T.S. N.T.S. N.T.S.

DOUBLE WALL PLATE

(2)-2x ON FLAT TO MATCH 6 x 3 WALL PL W/


WALL THICKNESS SIMPSON ABU66Z BASE
W/ 5/8 ANCHOR W/ 5"
EMBEDMENT @ 6'-0"

HEADER SEE PLAN

CL
COL

WINDOW
OPENING

6 x 6 POST W/ SIMPSON
ABA66Z BASE W/ 5/8 Seal
ANCHOR.
LRU26Z
APLH26 W/ FULL
MIN (2) STUDS
CONTACT SHIM
ON EACH SIDE

5"
OF OPENING &
SEE PLAN
MIN. (2)-2x ON FLAT TO MATCH
WALL THICKNESS EXISTING SLAB ON Revisions
No. Description Date
GRADE

WALL PLATE

4
TYP FRAMING AROUND WALL OPENING 5
TYPICAL COLUMN/WALL PL BASE DETAIL 6
RIDGE/BEAM TO RAFTER CONNECTION
N.T.S. N.T.S. N.T.S.

© 2011 Bohlin Cywinski Jackson

Owner

Project Name
APHH46

Enter address here


CCQ3-6SDS2.5 W/
FULL CONTACT SHIM A35 CLIP TYPE 4
Project Status
HUS48

TYPICAL DETAILS

OCC46
Scale As indicated

Date Issue Date

BCJ Project Number Project Number

S0.03
12/3/2021 1:22:17 PM

7
TYP VALLEY BEAM TO POST CONNECTION 8
TYP BEAM TO COLUMN/ STUD CONNECTION
N.T.S. N.T.S.
General Notes

1 2 3 4 5 6 7

11' - 9 3/4" 3' - 8 1/2" 8' - 1 3/8" 5' - 10 7/8" 9' - 1 1/4" 8' - 6 3/4"

6' - 5 5/8"
B

1' - 11 7/8"
C

8' - 5 3/8"
D

7' - 1 3/4"
E

4' - 9 5/8"
F

4' - 3 3/8"
G
Seal

6' - 5 1/8"
H
Revisions
No. Description Date

© 2011 Bohlin Cywinski Jackson

Owner

Project Name

Enter address here

Project Status

FOUNDATION FRAMING
PLAN
Scale 1/4" = 1'-0"

Date Issue Date

BCJ Project Number Project Number

S1.01
12/3/2021 1:23:33 PM

Foundation and Basement Plan


1 1/4" = 1'-0"
General Notes

1 2 3 4 5 6 7
NOTES:
1. SEE SHEETS S001 TO S003 FOR GENERAL NOTES AND TYPICAL DETAILS. 11' - 9 3/4" 3' - 8 1/2" 8' - 1 3/8" 5' - 10 7/8" 9' - 1 1/4" 8' - 6 3/4"
2. THE FOLLOWING NOTATIONS AND LINEWORK REPRESENT:

BOTTOM OF COLUMN A
TOP OF COLUMN

6' - 5 5/8"
EXISTING STRUCTURE

NEW STRUCTURE 2*8 @ 24in OC 2*8 @ 24in OC

1' - 11 7/8"
C

8' - 5 3/8"
2*10 @ 24in OC
2*8 @ 24in OC 2*8 @ 24in OC

D
2*6 @ 24in OC 2*6 @ 24in OC

7' - 1 3/4"
2*6 @
24in OC
2*6 @ 24in OC
2*6 @ 24in OC

4' - 9 5/8"
2*6 @ 24in OC

2*6 @ F
2*6 @ 24in OC

4' - 3 3/8"
2*6 @ 24in OC
24in OC
Seal

2*6 @ G
24in OC
2*6 @ 24in OC

6' - 5 1/8"
2*10 @ 24in OC
2*6 @
24in OC

H Revisions
No. Description Date

© 2011 Bohlin Cywinski Jackson

Owner

Project Name

Enter address here

Project Status

FIRST FLOOR FRAMING


PLAN
Scale 1/4" = 1'-0"

Date Issue Date

BCJ Project Number Project Number

S1.02
12/3/2021 1:23:59 PM

First Floor Framing Plan


1 1/4" = 1'-0"
General Notes

NOTES:
1. SEE SHEETS S-001 FOR GENERAL NOTES TYPICAL DETAILS. 1 2 3 4 5 6 7
2. DIMENSIONS SHOWN FOR REFERENCE ONLY. VERIFY IN FIELD.
3. CONTRACTOR TO PROVIDE ADEQUATE TEMPORARY SHORING AND SUPPORT.
4. THE FOLLOWING NOTATIONS AND LINEWORK REPRESENT: 11' - 9 3/4" 3' - 8 1/2" 8' - 1 3/8" 15' - 0" 8' - 6 3/4"

BOTTOM OF COLUMN/ SISTER STUDS


A
TOP OF COLUMN/ SISTER STUDS

6' - 5 5/8"
EXISTING STRUCTURE

NEW STRUCTURE

INDICATES LOAD BEARING/SHEAR WALLS


B

1' - 11 7/8"
USE PLYWOOD SHEATHING 15/32" THK W/8d COMMON NAIL AT
6" EDGE AND 12" FIELD SPACING W/MIN 1-1/4" PENETRATION INTO
FRAMING AND BLOCKING
INDICATES MSTA 18 STRAP/TIE LOCATION C
2*6 @

8' - 5 3/8"
2*10 @ 24in OC
24in OC

D
2*6 @ 24in OC

7' - 1 3/4"
2*6 @ 24in OC

2*6 @ 24in OC

4' - 9 5/8"
2*6 @ 24in OC

4' - 3 3/8"
2*6 @ 2*6 @ 2*6 @ 24in OC
2*10 @ 24in OC 24in OC 24in OC

2*6 @ G Seal
24in OC
2*10 @

6' - 5 1/8"
2*6 @ 24in OC 2*6 @ 24in OC
24in OC

2*6 @ 24in OC 2*6 @ 24in OC


H
Revisions
No. Description Date

© 2011 Bohlin Cywinski Jackson

Owner

Project Name

Enter address here

Project Status

SECOND FLOOR
FRAMING PLAN
Scale 1/4" = 1'-0"

Date Issue Date

BCJ Project Number Project Number

S1.03
12/3/2021 1:24:39 PM

Second Floor Framing Plan


1 1/4" = 1'-0"
General Notes

NOTES: 1 2 3 4 5 6 7
1. SEE SHEETS S-001 FOR GENERAL NOTES AND TYPICAL DETAILS.
2. DIMENSIONS SHOWN FOR REFERENCE ONLY. VERIFY IN FIELD.
3. CONTRACTOR TO PROVIDE ADEQUATE TEMPORARY SHORING AND SUPPORT.
4. PROVIDE MIN 3/4" PLYWOOD DECKING WITH 3/8" GRADE SHEATHING.
11' - 9 3/4" 3' - 8 1/2" 8' - 1 3/8" 5' - 10 7/8" 9' - 1 1/4" 8' - 6 3/4"
PROVIDE 6d COMMON NAILS, AT 6" AT DIAPHRAGM BOUNDARIES AND 12"OC
FIELD MIN 1-1/4" PENETRATION INTO FRAMING AND BLOCKING
4. THE FOLLOWING NOTATIONS AND LINEWORK REPRESENT:

BOTTOM OF COLUMN/ SISTER STUDS


A
TOP OF COLUMN/ SISTER STUDS

6' - 5 5/8"
EXISTING STRUCTURE

NEW STRUCTURE

1' - 11 7/8"
INDICATES DECKING/DIAPHRAGM SPAN DIRECTION

D INDICATES LOAD BEARING/SHEAR WALLS


USE PLYWOOD SHEATHING 15/32" THK W/8d COMMON NAIL AT C
6" EDGE AND 12" FIELD SPACING W/MIN 1-1/4" PENETRATION INTO
FRAMING AND BLOCKING

8' - 5 3/8"
D

7' - 1 3/4"
E

4' - 9 5/8"
F

4' - 3 3/8"
Seal

6' - 5 1/8"
Revisions

H No. Description Date

© 2011 Bohlin Cywinski Jackson

Owner

Project Name

Enter address here

Project Status

ROOF FRAMING PLAN

Scale 1/4" = 1'-0"

Date Issue Date

BCJ Project Number Project Number

S1.04
12/3/2021 1:25:07 PM

Roof Framing Plan


1 1/4" = 1'-0"