400
Submersible pumps for sewage and surface water within municipal
and commercial building applications. Non-clog impellers are
designed to maintain reliable performance at sustained efficiency.
Technical specification
Curves according to: Water, pure [100%],4 °C,999.9 kg/m³,1.569 mm²/s
[m] Head
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17 78.1%
16
15
14
13
12
11
10
9
8
7 S22 298mm
6
5
4
3
2
1
0
0 500 1000 1500 2000 2500 3000 [US g.p.m.]
Curve: ISO 9906
Configuration
Motor number Installation type
K1335.181 30-29-4ZA-W 30KW Wet well kit
Inlet diameter
200 mm
Maximum operating
speed
1485 rpm
Number of blades
2
Motor - Technical
Power factor - 1/1 Load Motor efficiency - 1/1 Load Total moment of inertia Starts per hour max.
0.85 93.2 % 0.468 kg m² 15
Power factor - 3/4 Load Motor efficiency - 3/4 Load Starting current, direct starting
0.78 93.1 % 540 A
Power factor - 1/2 Load Motor efficiency - 1/2 Load Starting current, star-delta
0.67 92.1 % 180 A
[m] Head
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17 78.1%
16
15 14.7 m
14
13
12
11
10
9
8
7 S22 298mm
6
5
4
3
2
1 2333 US g.p.m.
0
0 400 800 1200 1600 2000 2400 2800 3200 [US g.p.m.]
Operating characteristics
Pumps / Flow Head Shaft power Flow Head Shaft power Hydr.eff. Specific NPSHre
Systems Energy
1 2330 US g.p.m. 14.7 m 27.8 kW 2330 US g.p.m. 14.7 m 27.8 kW 76.2 % 0.0564 kWh/m³ 5.95 m
136 616
1092
309 116
DN200
995
450
380
19
Z Z
92
182
56
23
1400
88
133
255
280
Outlet center line
Z-Z