You are on page 1of 4

Q1: State the definitions and give the relation between DOD and

SOC?
DOD: Depth of discharge is the indication of the quantity of
electricity already extracted from an accumulator related to its
maximum capacity.

SOC: State of charge is an indication of the remaining quantity of


electricity available from an accumulator, related to its maximum
available capacity.

The relation between DOD and SOC


Soc=1-DOD.

Q2:

In the following example state the round-trip efficiencies?


Solution:
Q3: Compute the service times when charging and discharging
batteries of
1Ah (1,000mAh) for the given C-rates as shown below:

Solution:
5C: service time= 12 minutes
2C: 30 min
1C: 1h
0.5C: 2h
0.2C: 5h
0.1C: 10h
0.05C: 20h.
Q4:plot and discuss Ragone plot of an ideal battery assuming L=0
of the battery.