ARI ENGINE ROOM SIMULATOR

TRAINEE ASSESSMENT
Date : 09-11-2022
Instructor Name : Trainee Station : ERS 1
Student Name : Course Name : DEAD SHIP

Start Time : Allotted Time : N/A


Finish Time : Time Taken :

SN Task Task value Time Marks


1 The Emergency Generator is Started Not Started 4
1 The Emergency Generator is on Stand by Not Standby
2 The Emergency Generator is Onload Off Load 4
3 The preparation start up and operation of main air compressor no.2 Not Started 7
3 The filling main air bottle no.2 Empty
4 In filling emergency air bottle Empty 2
5 The preparation start up and operation of a diesel engine generator No.1 Not Started 10
5 The preparation start up and operation of a diesel engine generator No.2 Not Started
6 Connecting DG1 to the Main Switchboard Off Load 10
6 Connecting DG2 to the Main Switchboard Off Load
7 The preparation start up and operation of fresh water hydrophore system NOT OK 6
8 The preparation start up and operation of main air compressor no.1 Not Started 6
8 The filling main air bottle no.1 Empty
9 Line up the sewage system Not Started 6
10 Domestic refrigeration - Meat Room Temp. OK NOT OK 8
10 Domestic refrigeration - Fish Room Temp. OK NOT OK
10 The preparation of PORT accommodation air conditioner NOT OK
10 The preparation of STBD accommodation air conditioner NOT OK
10 The preparation of engine control room air conditioner NOT OK
11 The start up of Port Vent Fan no.1 Stop 4
12 The start up of Port Vent Fan no.2 Stop 4
13 The start up of Starboard Vent Fan no.1 Stop 4
14 The start up of Starboard Vent Fan no.2 Stop 4
15 The preparation start up and operation of Diesel oil purifier Feed Off 8
16 Start the MGPS Stop 4
17 Start the ICCP - Forward Stop 2
18 Start the ICCP - Aft Stop 2
19 Prepare Hyper mist water fire extinguishing system for engine room for Auto operation Stop 5

Marks Obtain : 0 / 100 , 0 %