Test Report

ULR No. TC870622000005425F Date of Report Issue :-31/10/2022


Letter Ref.No. SSCDL/2021/ABD/51/Q Date:-22/10/2022
Name of Client Executive Engineer,
Satna Smart City Development,Limited
Distt.-Satna (M.P.)
Name of Contractor M/S ABC Associate,Satna
Material Discription one bag fine aggregate
Date of Sample Received 10/22/2022
Date of Test Start 10/26/2022
Date of test Completion 10/29/2022
Name of work Construction of Visual improvement under Satna Smart City. Work Order No. SSCDL/2021/ABD
/51/791,Date:-23/08/2021

Test method as per IS: 2386:1963 RA-2016


GRADATION OF FINE AGGREGATE ARE REPORTED AS BELOW
Norms % As Par IS 383:1970 RA-
S.No. Sieve Size % Passing Weight Test method
2016
1 10 mm 100 100
2 4.75 mm 91.85 90-100
3 2.36 mm 77.65 75-100
4 1.18 mm 59.35 55-90 IS:2386(Part I) 1963 R.A.2014
5 600 Micron 42.51 35-59
6 300 Micron 19.25 18-30
7 150 Micron 5.32 0-10
TEST RESULTS OF FINE AGGREGATE ARE REPORTED AS BELOW
Units of
S.No. Test Parameter Results Norms % As Par IS:383:2016 Test method
Measurement
1 Silt Content % 1.68 - IS:2386(Part-3) 1963 R.A.2016
1 Fineness Modulus - 3.04 - IS:2386(Part-1) 1963 R.A.2016
2 Water absorption % 1.82 11-105 IS:2386(Part-3) 1963 R.A.2016
3 Specific Gravity - 2.59 22-33 CPWD Special Val.1

Test Performed By Result Checked and Verified By Authorized Signatory

Neelambar Awadhiya
Testing Engineer Quality Manager
Note:-
1.The results relate only to the items tested.
2. This test report Shall not be reproduced except in full, without approval of the AC&TL laboratory can provide assurance that parts of a report are not taken out
of context.
3. The results apply to the sample as received.
****End Report****
Test Report
Report No. TC870622000005426F Date of Report Issue :-31/10/2022
Letter Ref.No. SSCDL/2021/ABD/51/Q Date:-22/10/2022
Name of Client Executive Engineer,
Satna Smart City Development,Limited
Distt.-Satna (M.P.)
Name of Contractor M/S ABC Associate,Satna
Material Discription One Bag Coarse Aggregate 10 MM 20 KG.
Date of Sample Received 10/22/2022
Date of Test Start 10/26/2022
Date of test Completion 10/29/2022
Name of work Construction of Visual improvement under Satna Smart City. Work Order No.
SSCDL/2021/ABD /51/791,Date:-23/08/2021

Laboratory Test - RESULT OF Coarse Aggregate


as per IS: 2386:1963 RA-2016
GRADATION OF COARSE AGGREGATE ARE REPORTED AS BELOW

S.No. Sieve Size % Passing Weight Norms % As Par IS 383:1970 RA-2016 Test methad

1 12.5 mm 100 100


2 10 mm 87.65 85-100
IS:2386(Part I) 1963 R.A.2016
3 4.75 mm 16.35 0-20
4 2.36 mm 2.35 0-5
TEST RESULTS OF COARSE AGGREGATE ARE REPORTED AS BELOW

S.No. Test Parameter Units of Measurement Results Norms % As Par Test methad

Aggregate Impact
1 % 17.23 30 % Max. IS:2386(Part-4)-1963 R.A.2016
Value
Aggregate
2 % 15.62 10%-30% IS:2386(Part-1)-1963 R.A.2016
Flakiness Index

Aggregate
3 % 14.85 10%-30% IS:2386(Part-1)-1963 R.A.2016
Elongation Index
Test Performed By Result Checked and Verified By Authorized Signatory

Neelambar Awadhiya
Testing Engineer Quality Manager
Note
1.The results relate only to the items tested.

2. This test report Shall not be reproduced except in full, without approval of the AC&TL laboratory can provide assurance that parts of a report are not taken
out of context.
3. The results apply to the sample as received.
*****End Test *****
Test Report
Report No. TC870622000005427F Date of Report Issue :-31/10/2022
Letter Ref.No. SSCDL/2021/ABD/51/Q Date:-22/10/2022
Name of Client Executive Engineer,
Satna Smart City Development,Limited
Distt.-Satna (M.P.)
Name of Contractor M/S ABC Associate,Satna
Material Discription One Bag Coarse Aggregate 20 MM 20 KG.
Date of Sample Received 10/22/2022
Date of Test Start 10/26/2022
Date of test Completion 10/29/2022
Name of work Construction of Visual improvement under Satna Smart City. Work Order No.
SSCDL/2021/ABD /51/791,Date:-23/08/2021

Laboratory Test - RESULT OF Coarse Aggregate


as per IS: 2386:1963 RA-2016
GRADATION OF COARSE AGGREGATE ARE REPORTED AS BELOW

S.No. Sieve Size % Passing Weight Norms % As Par IS 383:1970 RA-2016 Test methad

1 40 mm 100 100
2 20 mm 88.59 85-100
IS:2386(Part I) 1963 R.A.2016
3 10 mm 17.21 0-20
4 4.75 mm 3.62 0-5
TEST RESULTS OF COARSE AGGREGATE ARE REPORTED AS BELOW

S.No. Test Parameter Units of Measurement Results Norms % As Par Test methad

Aggregate Impact
1 % 17.45 30 % Max. IS:2386(Part-4)-1963 R.A.2016
Value
Aggregate
2 % 15.62 10%-30% IS:2386(Part-1)-1963 R.A.2016
Flakiness Index

Aggregate
3 % 16.35 10%-30% IS:2386(Part-1)-1963 R.A.2016
Elongation Index
Test Performed By Result Checked and Verified By Authorized Signatory

Neelambar Awadhiya
Testing Engineer Quality Manager
Note
1.The results relate only to the items tested.

2. This test report Shall not be reproduced except in full, without approval of the AC&TL laboratory can provide assurance that parts of a report are not taken
out of context.
3. The results apply to the sample as received.
*****End Test *****
Test Report
ULR No. TC870622000005428F Date of Report Issue :-31/10/2022
Letter Ref.No. SSCDL/2021/ABD/51/Q Date:-22/10/2022
Name of Client Executive Engineer,
Satna Smart City Development,Limited
Distt.-Satna (M.P.)
Name of Contractor M/S ABC Associate,Satna

Material Discription PPC (Ultratech)


Date of Sample Receive 10/22/2022
Date of Test Start 10/22/2022
Date of test Completion 10/31/2022
Name of work Construction of Visual improvement under Satna Smart City. Work Order No. SSCDL/2021/ABD
/51/791,Date:-23/08/2021

Laboratory Test - RESULT OF PPC CEMENT IS 1489-1(1991)


Unit of NORMS as per IS: 1489-
Sr.
Test Parameters Results 1(1991) Test Method
No.
IS:4031 (Part -IV)-
1 Consistency % 29.5 NA
1988,RA-2014
IS:4031 (Part -V)-
2 Initial Setting Time Minutes 162 -
1988,RA-2014
IS:4031 (Part -V)-
3 Final Setting Time Minutes 315 -
1988,RA-2014
IS:4031 (Part -VI)-
4 Compressive Strength after 72±1 hr MPa 23.65 -
1988,RA-2014
IS:4031 (Part -VI)-
5 Compressive Strength after 168±2 hr MPa 34.58 -
1988,RA-2014
IS:4031 (Part -III)-
6 Soundness MM 2.15 < 10 mm
1988,RA-2014
IS:4031 (Part -VI)-
7 Specific Gravity .- 2.96 3.15
1988,RA-2014
Test Performed By Result Checked and Verified By Authorized Signatory

Neelambar Awadhiya
Testing Engineer Quality Manager

Note:-
1.The results relate only to the items tested.

2. This test report Shall not be reproduced except in full, without approval of the AC&TL laboratory can provide assurance that parts of a report are
not taken out of context.
3. The results apply to the sample as received.
***** End Report ******
Test Report
ULR No. TC870622000005429F Date of Report Issue :-31/10/2022
Letter Ref.No. SSCDL/2021/ABD/51/Q Dated:-22/10/2022
Name of Client Executive Engineer,
Smart City Satna Development Ltd.,
Distt.-Satna (M.P.)
Name of Contractor M/S ABC Associate,Satna

Material Discription Sample of GSB (Grading -II)


Date of Sample Received 10/22/2022
Date of Test Start 10/25/2022
Date of test Completion 10/31/2022
Name of work Construction of Visual improvement under Satna Smart City. Work Order No. SSCDL/2021/ABD /51/791,Date:-
23/08/2021

GRADATION (G-II)
S. No. Sieve Size Percent by Weight Passing Norms Test Method
1 53.0 mm 100 100
2 26.5 mm 85.36 70-100
3 9.50 mm 61.25 50-80
As Per MORTH Table No. 400-
4 4.75 mm 48.56 40-65
1
5 2.36 mm 41.52 30-50
6 0.425 mm 13.06 .10-15
7 0.075 mm 3.52 .<5

Test Method IS:2720 and IS:2386,1963 RA:2016


S. No. Name Of Test Units of Measurements Result Test Method
Aggregate Impact
1 % 18.56 IS:2386 (Part 4)
Value (Dry)
OMC % 5.26
2 IS:2720 (Part 08):2015
MDD g/cc 2.21
CBR Test at 5.0mm
3 % 31.85 IS:2720 (Part 16):2016
parameters

Test Performed By Result Checked and Verified By Authorized Signatory

Neelambar Awadhiya
Testing Engineer Quality Manager

Note:-
1.The results relate only to the items tested.

2. This test report Shall not be reproduced except in full, without approval of the AC&TL laboratory can provide assurance that parts of a report are not taken out of
context.
3. The results apply to the sample as received.
****END REPORT****
Cube Test Report

ULR No.-. TC870622000004784F Date of Report Issue :-19/09/2022


Letter Ref.No. SSCDL/2021/ABD/51/Q Date:-17/09/2022
Name of Client Executive Engineer,
Smart City Satna Development Ltd.,
Distt.-Satna (M.P.)
Name of Contractor M/S ABC Associate,Satna
Material Discription C.C. Cube (M-30) 07 Days
Date of Sample Received 9/17/2022
Name of work Construction of Visual improvement under Satna Smart City. Work Order No. SSCDL/2021/ABD
/51/791,Date:-23/08/2021

Laboratory Test - Compressive Strength after 07 days Cube Test


as per IS: 516:2018
Ultimate
S.No. Size Of Cubes Mix weight Date Of Casting Date of testing Compressive strength N/mm2
load (P)
Location:-
1 8.305 618.00 27.47

2 150x150x150mm M-30 8.315 9/10/2022 9/17/2022 631.00 28.04

3 8.319 645.00 28.67

Avg. Compressive strength N/mm2 28.06

Test Performed By Result Checked and Verified By Authorized Signatory

Neelambar Awadhiya
Testing Engineer Quality Manager
Note:-
1.The results relate only to the items tested.

2. This test report Shall not be reproduced except in full, without approval of the AC&TL laboratory can provide assurance that parts of a report are not taken out of
context.

3. The results apply to the sample as received.

***** End Report ******


of Report Issue :-19/09/2022
Date:-17/09/2022

SSCDL/2021/ABD

ompressive strength N/mm2

N/mm2
N/mm2
N/mm2

N/mm2

horized Signatory

iya
Quality Manager

parts of a report are not taken out of