References for using the new ID CPR74 Reader instead off the
ID CPR44
Feig has replaced the ID CPR44 reader with the new ID CPR.74. This application note
describes the main technical differences between ID CPR.44 and the successor, with
more features and powerful reader ID CPR74.
In general the ID CPR74 will be interface compatible to FEIG ID CPR-Reader. This
application note will enable you to make an informed assessment for your existing and
new application to be sure that this new reader can achieve your technical requirements
depending on your hard- and software environment.

ID CPR.44 ID CPR.74

Available Reader types

 ID CPR44.02-4SCUSB 3453.001.00  ID CPR74-4SCUSB 4607.000.00

 ID CPR44.01-4SCUSB 3583.001.00  ID CPR74-CUSB 4606.000.00

 ID CPR44.02-CUSB 3708.001.00

 ID CPR44.01-CUSB 3701.001.00

Reader Hardware Type Number

85 114

N61010-0e-ID-C.docx / 2016-10-19
®
OBID classic-pro HF ID CPR.74-x

ID CPR.44 ID CPR.74
Antenna selection (internal / external)

By Hardware (Solder Bridge) By Software


ID CPR44.02: default, internal antenna ID CPR.74-XUSB: Default, internal antenna

Protocol CRC Calculation

Via RS232TTL => necessary Via RS232TTL => necessary


Via USB => not necessary Via USB => necessary

Power Supply

A external 5 V DC power Supply is A external 5 V DC power Supply is


recommended for all reader variants. recommended for all reader variants.
ID CPR74-CUSB without SAM can be
powered via a high powered USB
Interface (500mA) without using a
external power supply.
To power the reader over the USB port
and an external power supply is not
allowed and can destroy the reader.

Dimension

60 x 50 x 7,3 mm (without SAM) 68 x 50 x 7,2 mm (without SAM)


60 x50 x 13,8 mm (with SAM 68 x 50 x 9,6 mm (with SAM)

Protocol Frame

Standard Protocol Frame Recommended:


Advanced Protocol Frame Advanced Protocol Frame

Scan Mode

Available for RS232TTL Interface Available for RS232TTL and USB Interface
(Scan mode and USB works as HID)

Reader-Configuration

- A change of the reader configuration in the


EEPROM requires a “0x63 CPU Reset”

Compatibility Note 2 FEIG Electronic GmbH


®
OBID classic-pro HF ID CPR.74-x

Software Application and SDK requirements


The new RFID-reader ID CPR.74 is compatible to the ID CPR44 reader with his basic
functions in reference to the reader API’s.
Therefore it will be possible to integrate the new reader without any changes on the
existing software application. In the cases of compatibility issues a new compilation with a
current SDK should be sufficient.

Note:
 We recommend to use the “Advanced Protocol Frame” if a application has to
be new compiled.

 For new projects and applications we recommend to use the current SDK
versions.

Feig Software and SDK‘s Available from


CPRStart 2016 V9.09.07 now
OBIDFirmwareUpdateTool V7.07.00 now
SDK.NET V4.07.00 now
SDK WIN C++ V4.07.00 now
SDK JAVA V4.07.00 now
SDK Linux V4.07.00 now