O P E R AT I N G M O D E S O F D U P L E X M U LT I E C O U N I T S
Unit ventilators, heat recovery – issue 03/2018
i1 e1 i1 i1 e1
Ventilation with heat recovery Circulation heating Ventilation without heat recovery
with re-heating (with cooling) or cooling (via bypass)
e1 ... Fresh outdoor air suction i1 ... Exhaust air suction T/E ... Central heating / electrical heater connection
e2 ... Fresh filtered air outlet i2 ... Exhaust air outlet CH ... Cooling connection
SELECTION SOFTWARE
we recommend using our dedicated design ATREA s.r.o., Čs. armády 32 Phone: +420 483 368 111
software. You can find it on our website 466 05 Jablonec n. Nisou Fax: +420 483 368 112
s a v e y o u r e n e r g y
800
700
600
500
400
2500
1100 M
1500 M
3500
500 MultiEc
4500
800 Mu
550
650
900
750
300
0 Mu
0M
0M
0M
MultiE
Mult
Mult
ult
ultiEco
ltiEco M10
ultiE
ulti
ultiE
200
ltiEc
iEco M10
iEco M
iEco
Eco
co M10
o M106
co M
co M
o M11
100
M119
M110
M11
110
116
116
7
3
6
0
0 1 000 2 000 3 000 4 000 5 000 6 000 7 000 8 000 9 000 10 000 11 000 12 000
Note: For detailed information we recommend to use ATREA selection software. Air volume (m3/h)
100
Heat recovery efficiency φ (%)
FLOOR-STANDING (front view) UNDERCEILING (top view) FLOOR-STANDING FLAT (top view)
MultiEco 500 to 6500 MultiEco 500 to 6500 MultiEco 1500 to 5500
L B alternative spigot position alternative spigot position
(configuration 30/5) (configuration 41/5)
405 x 305 X3 ( D)
100
door door
door
Y2
Y2
Y2
Y2
Y3
H X2 X2 X2 X2
C B L B L B
Y1
405 x 305 X1 ( D) 405 x 305 X1 ( D)
100
100
door door
K K K
200
X1 ( D)
Y3
Y3
H2
H
H
Y4
Y4
C B C B
Y1
Y1
door
X4 ( D) X4 ( D) X1 ( D)
L2
alternative spigot position X1 ( D)
150
(configuration 11/10)
Y4
Y4
Y4
Y4
MultiEco 7 500 to 9 000
2100* L
door door
B 671 1 403 1 296
X4 ( D) X4 ( D) X4 ( D) X4 ( D)
X1
alternative spigot position alternative spigot position
(configuration 30/10) (configuration 41/10)
Y1
H
Y1
X1
200
Y4
Y4
X4 X4
* For DUPLEX 6500 MultiEco in configuration 30/x. For detailed information please use our ATREA selection software.
Basic port Port with flexible Port with damper Port with damper
CIRCULAR
80 215 80 215
X + 20
RECTANGULAR
X
door
150 150
Y+20
Y
INSTALLATION AND VERSIONS
INSTALLATION VERSIONS AND CONNECTING PORTS
DUPLEX 500 to 9000 MultiEco units are available in a range DUPLEX MultiEco units are characterised by a wide range
of versions to facilitate their installation in the machine room. This of accessories – the ports may be optionally fitted with flexible
significantly increases options to install DUPLEX MultiEco units in flanges and inlet ports may have shut-off dampers if required.
cramped spaces.
For structural reasons and to ensure condensate drain it is not
possible to have all units available in all mounting positions. Detailed
drawings are shown in the summary table “Mounting positions”.
MOUNTING POSITIONS
i2 e2 e2 i2
10 11
e1 i1 i1 e1
e2 i2 i2 e2
30 31
i1 e1 e1 i1
i2 e2 e2 i2
40 41
e1 i1 i1 e1
500, 800 and 1100 MultiEco units are available in following configurations:
– horizontal: 10/0, 11/0
– ceiling-suspended: 30/0, 30/1, 30/4, 30/5, 31/0, 31/1, 31/4, 31/5
For more detailed technical information check out ATREA selection software.
UPRIGHT POSITION R O O F T O P U N I T S – F L AT
DUPLEX Multi-Eco-V 1500 to 6500 DUPLEX MultiEco-N 1500 to 9000
DUPLEX units must be installed with the prescribed handling Each drawing shows the minimum handling space.
space around the unit in mind. In addition, each unit must have the minimum handling space
Below the unit at least 150 mm must be left to install the DN 32 of 600 mm from the side of the control system electric
condensate drain line. This line must run through a U-bend at least switchboard according to CSN.
150 mm high into a sewer. This space is easily provided when the Units with a heating or cooling control manifold must have free
steel supporting feet supplied as standard are used. Handling space from the side of the manifold, too.
space in front of the unit must be maintained for opening the front
door, replacing filters and providing servicing and installation
access to each unit part.
Handling space in front of the door Handling space for accessories
Floor-standing horizontal Floor-standing horizontal Control modules
500–6500 MultiEco 7500–9000 MultiEco
min. 600
hinges
hinges
KM RD5
120
200
200
K K K K K K
floor
Control manifolds
wall wall
min. 30
min. 30
600
min.
RE-TPO4 / RE-TPO3
R-CHW
200
ÚT
min. T
min. T
K K K
Me.xxx; Mi.xxx
Fans
All units are equipped with high-efficiency fans (ebm-papst and Ziehl Abegg) with free-running impellers and backward curved blades.
Ventilators of DUPLEX 500 to 9000 MultiEco units meets the requirements of the ErP 2015.
Sx
Heat recovery exchanger
The only heat recovery core type S7 or S3 made of plastic in counterflow arrangement with high
efficiency – up to 93 %.
By-pass (”B”)
B.x
By-pass of the plate heat recovery core on supply air side. By-pass consists of an opposed-blade damper and an actuator.
It is fitted next to the recovery core inside the unit; it does not increase size of the unit.
The standard actuator is BELIMO 24 V; other types are available upon request.
RE-TPO.x R-CHW.x
Heating coil Cooling coil
hydraulic kit hydraulic kit
Its function is to control heating capacity Its function is to control cooling capacity of
of a heating coil. It consists of a three-speed a chilled-water cooling coil. It always consists
pump, two globe shutoff valves and connection of two globe shutoff valves and connection pipes.
pipes. Further equipment depends on the type: Further equipment depends on the type:
–RE-TPO4 – four-way mixing valve with –R-CHW3 – three-way mixing valve with
an actuator for digital control system an actuator
–RE-TPO3 – three-way mixing valve with –R-CHW2 – throttling valve with an actuator for
an actuator for digital control system digital control system
MFF FK.x
Tu b e m a n o m e t e r s Spare cartride
Accessory for filters for simple view of current filters
pressure drop. The tube manometers are Replacement filter cartridges in different sizes
obligatory for hygienic unit design in accordance based on the unit type. Available in G4, M5 and
with the VDI 6022. F7 filtration class.
H.P
Delivery of diassembled unit Flexible
All units can be delivered dismantled on request. connections
The unit is to be assembled by rivets and bolts Round and rectangular ports can be equipped
directly on site, therefore the unit can be with flexible connections upon request.
installed in inaccessible location.
Casing insulation class T3, thermal bridging
class TB2.
TPO
Electric heating coil (EPO-V)
Hot water heating coil (TPO) Separately supplied heating coil to be fitted
Separately supplied coil for installation into into round or rectangular duct. Capacities and
round duct. diameters can be found in respective
It is suitable for cramped locations, where catalogue sheets.
it is impossible to put the coil inside the unit,
as well as for rooftop units.
The coil is standardly equipment with the steam-
gas capillary thermostat.
Capacities and diameters can be found
in respective catalogue sheets.
CF.XXX EPO-V
Constant air flow Electric preheaters
and pressure EPO-V
Manometers reading fan pressure together EPO-V electric heating coils to provide the
with controls, enables intelligent fan control of antifreeze protection of the heat recovery
preselected airflow. This accessory assumes exchanger when equal-pressure ventilation is
the unit is equipped with ATREA digital control continuously required. It is installed inside a duct
system. Using a second manometer (optional on the outdoor supply air side of the unit (e1).
accessory) in the supply air duct enables the This accessory assumes the unit is equipped
user to control constant pressure in the with ATREA digital control system.
supply duct.
DUPLEX MultiEco units are delivered with basic control Features of the control systems
components or with complete control systems. • selection of the most suitable and efficient control
There are three types of control systems available (Basic, system at the lowest cost, depending on the particular
CPM and RD5) according to customer needs and an application
application. The systems also include variety of sensors • control system is integrated with the unit, most
(temperature, humidity, air quality, CO2) for effective components are already wired and checked in factory,
operation control. thus reducing the risk of incorect wiring
• no control system project documentation is necessary
for standard cases, standardized solutions can be used
• simple wiring, system simplicity, error indication
• qualified technical support and consulting
SUMMARY OF DUPLEX MULTIECO CONTROL SYSTEMS
Type Use Controller
Basic – all electrical components are wired to a junction box terminal strip inside or
outside the unit
– standard components are fans, damper actuators, capillary freeze basic version
protection thermostat of hot water heating coil (fans, actuators, thermostats,
– more components is included upon customer's request (exact actuator pressure switches
type, sensors, thermostats, pressure switches etc.) and others on request)
– suitable for applications with separate delivery of control system; e.g. large
buildings with central control system etc.
Supervisory control system