Performance
Linear Measurement Range 2 mm (80 mils)
Initial Air Gap 0.5 mm (20 mils) Initial gap Linear measuring range
-1,0 -0,8 -0,6 -0,4 -0,2 0,0 0,2 0,4 0,6 0,8 1,0 Amplitude
[mm]
Incremental Scale Factor (ISF) ISO: 8 V/mm (203.2 mV/mil) ± 5%
0,5 0,7 0,9 1,1 1,3 1,5 1,7 1,9 2,1 2,3 2,5
-2,0
@ temperature range 0 to 45°C -4,0
-6,0
(+32 to +113°F) -8,0
-10,0
-12,0
Deviation from best fit straight line (DSL) ± 0.025 mm (± 1 mil) -14,0
-16,0
(+32 to +113°F)
Uout operatting range -2... -18V
[V] operatting range -4... -20V
www.emerson.com/ams 2
PR6423 November 2020
Dimensions
PR6423/xxx-xxx (Standard)
www.emerson.com/ams 3
PR6423 November 2020
www.emerson.com/ams 4
PR6423 November 2020
Ordering Information
Tip Diameter Case Threads Armored Cable Model No.
No PR6423/00
M10x1 PR6423/01
Yes
PR6423/03*
8mm
No PR6423/10
3/8”-24 UNF PR6423/11
Yes
PR6423/13*
Model No. Case Thread X Adapter Plug X Cable Length X Cable End X
Example: PR6423/000-000
ECS 8mm, M10X1, NO ARMOR, 25MM SLEEVE, 1+3M CABLE, LEMO
www.emerson.com/ams 5
PR6423 November 2020
Product Accessories
Model Number Product Description
PR 6480 Probe Holder