You are on page 1of 2
Carrier ~ Installation Instructions er eet Accessory Side Filter Rack 58GA900011 ASSEMBLED VIEW (LEFFHAND SIDE APPLICATION) SMEET METAL SCREWS BOW EACH SIDE 3. 0N TP sacToRY- SUPPLIED FILTERS (2) ~ FILTER RACK Fig, 1 — Filter Rack, Expanded View INTRODUCTION claim with transportation agency To check that : an package contents are complete, compare package ne S8GA9I Sid Rack can be used withthe $80 Seren uplow envied furnaces to COMeN aaa! Table Yand Fi 1 provide high-capacity filtration up to 2000 cfm. The accessory is shipped from the factory assembled and includes two expanded aluminum filters Table 1 — Package Contents It can be easily installed on either side of the ———_—_——_—_—— furnace to provide a return air duct connection of 24 1/8-in, high x 22.7/8-in. wide. Each filter in- v Fiver Rack with Removable Access Doo cluded is 16 in, x 25 in. x Linch 2 | Expanded Abminom Fitter Parts necessary for field installation are in- cluded in the package When unpacking filter rack, should any in-transit damage be observed, file © Carrier Comporation 1973 Form 886-581 INSTALLATION 1. Determine where accessory side filter rack will be installed on furnace (left- or right-hand side). Punch out knockouts on side of furnace and field cut return air opening in furnace per dimensions indicated in Table 2 and Fig. 2. Using a Phillipstype screwdriver, remove the filter rack access door. Retain securing screws. Remove the two filters from the rack thru the access opening. 3. Position filter rack against furnace side opening so that bottom surface of filter rack is flush with the bottom edge of the furnace return ait opening. Insert blocks (or equivalent) under rack to keep it elevated in position, 4, Using holes in top flange of filter rack as pilots to mark position of corresponding holes on furnace casing, drill with @ no 31 drill thru furnace casing. Secure top flange of filter rack to furnace using three sheet metal screws provided ‘Table 2 — Furnace Side Return Air Opening Dimensions* “FURNACE cuToUT oWENSiONS Gnd Wedel | 7 ~ky iscaioo Seeatzs | 200 Seats | nccoso | 100,200 wm | om 75 | s he secazoo |” 200 seccis0 \ec175 +See Fig 2 for location of return ae opening in furnace se Access the inner vertical flanges of filter rack thru filter rack return air opening. Drill three holes thru each vertical flange and thru furnace casing, Secure sides of filter rack to furnace using six sheet metal screws provided. Seal bottom of filter rack to Furnace side panel with duct tape. Replace filters in filter rack, attach access door, and remove positioning blocks inserted in step 3. Connect return air ductwork to filter rack return air opening flanges. i r i i | (FIELO cur EITHER toe ' 1 1 1 1 i & SIDE RETURN APPLICATION 2 — Locating Side Return Air Opening Manufacturer reserves the right to change any product specifieations without notes. CARRIER AIR CONDITIONING COMPANY + SYRACUSE, NEW YORK Tab 10 Form 68C-5S1 Supersedes 596-281 Printed in USA 1272 Codes Eand MS talon No 825-890,

You might also like