You are on page 1of 2

บริษทั เอดีดี เฟอร์ เนส จำกัด

ADD FURNACE CO.,LTD.


44 ซอยบรมราชชนนี 70 ถนนบรมรำชชนนี แขวงศำลำธรรมสพน์ เขตทวีวฒ
ั นำ กรุ งเทพฯ 10170
โทร: 02-888-3472 โทร (.ออกแบบ):08-08-170-170 แฟกซ์: 02-888-3258
https://www.add-furnace.com E-mail: sales@add-furnace.com

BK-G4

Compact diaphragm meters for


residential installations

Applications The meter is supplied as a top-in-top-out, Main features


two pipe version. The housing can be
• Media made of steel (folded model) or • Meets the requirement of OIML R6
Natural gas, town gas, propane, and R31
aluminum (screw-connection model).
butane, air, inert gas • NOM 014 and EC approved
In the measuring unit, the diaphragms 3
• Flow rates from 0.04 to 6 m /h
• Industries Gas are moving stress free without
distribution mechanical stops. This ensures both low • Maximum operating pressure
0.5, 1,1.5 bar (depend on body
bearing loads and material)
• Tasks
a quite operation. The dimensionally
Measurement of gas volume • Water tight index
stable synthetic diaphragm has the
proven stadium-shaped form.
• Pulse magnet for 0.1 unit/pulse
incorporated for remote reading
Measuring principle purpose

• Low noise level


The internal, separated measuring unit High-grade materials and components as
contains four measuring chambers which are well as the patented slide control (K- • Low susceptibility to
contamination
separated by synthetic diaphragms. The system) ensures a high quality standard.
chambers are filled and emptied periodically The K-system synchronizes the • Operating gas temperature from -20
o o
C to +50 C
and the movement of the diaphragm is operation of the slides with the current
transferred via a gear to the crankshaft. In flow through the measuring chamber • Stable synthetic, stadium-
shaped diaphragm
turn, this shaft moves the valves which control thus achieving minimum flow channels
the gas flow. The revolutions of the crank and an extremely high accuracy of • Anti-reverse operation

shaft are transferred via a drive gear to the measurement. • Enlarge index numerals
index.
Due to the small slides, BK-G4 is not
• Cyclic Volume 1.2 Liters

Brief information susceptible to contamination. The


measuring unit is adjusted by a patented
BK-G4 is a compact residential diaphragm gas meter needle and scale system.
which has been designed to meet the highest
demand with regard to accuracy of measurement Although the design is very robust, the
and safety. It incorporates both
meters are still measuring instrument and
Optional features
innovative features and Elster Kromschroder’s
as such should be handled with care.
gas measurement know-how of many • Anti-reverse flow valve
decades.
• Retro-fit low frequency pulser
บริษทั เอดีดี เฟอร์ เนส จำกัด
ADD FURNACE CO.,LTD.
44 ซอยบรมราชชนนี 70 ถนนบรมรำชชนนี แขวงศำลำธรรมสพน์ เขตทวีวฒ
ั นำ กรุ งเทพฯ 10170
โทร: 02-888-3472 โทร (.ออกแบบ):08-08-170-170 แฟกซ์: 02-888-3258
https://www.add-furnace.com E-mail: sales@add-furnace.com

BK-G4 Compact gas meter for residential installations

Dimensions

Dimension (mm) Body Weight


Meter Configuration
A B C D E M Material (kg)

110 193 M30x2


221 67 157 Steel 1.9
130 205 M34x1.5
Top-in Top-out
M34x1.5
130 215 72 202 165 Aluminum 2.15
G1”

Typical error curve Order information


Diaphragm Meter G4
Configuration Type
Connection Size
Flow Direction

Pressure loss curve

-BK-G4 DS Rev.0