UNCONFINED COMPRESSION TEST


Location Err:540 Site :
Sample type : Undisturbed Code Err:540
Depth Err:540 Sample No. : U1
Sample Data : Area (A0) = 10.70 cm2 Height (L0) = 6.99 cm
w = 26.34 % gd = 1.44 gr/cm3
Machine Data : LRC = 1.42 kgf Diameter = 3.69 cm
deformation load dial DL unit strain area CF corrected total load sample
dial reading (units) col 1 . 10-2 DL / Lo 1 - col 4 area A' on sample unit load
1 2 3 4 5 6 7 8
25.00 0.5 0.25 0.036 0.964 11.095 0.710 0.064
50.00 0.8 0.50 0.072 0.928 11.523 1.136 0.099
75.00 1.0 0.75 0.107 0.893 11.984 1.420 0.118
100.00 1.3 1.00 0.143 0.857 12.484 1.846 0.148
150.00 1.8 1.50 0.215 0.785 13.621 2.556 0.188
200.00 2.4 2.00 0.286 0.714 14.986 3.408 0.227
250.00 2.9 2.50 0.358 0.642 16.655 4.118 0.247
300.00 3.5 3.00 0.429 0.571 18.742 4.970 0.265
350.00 4.0 3.50 0.501 0.499 21.427 5.680 0.265
400.00 4.6 4.00 0.572 0.428 25.011 6.532 0.261
450.00 5.0 4.50 0.644 0.356 30.033 7.100 0.236
500.00 5.3 5.00 0.715 0.285 37.579 7.526 0.200
600.00 6.0 6.00 0.858 0.142 75.537 8.520 0.113
700.00 6.4 7.00 1.001 -0.001 -7478.157 9.088 -0.001
800.00
900.00
1000.00
1100.00
1200.00
1300.00
1400.00
1500.00
1600.00
1700.00
sam ple unit load (kgf/cm 2)

0.300
0.265081369188338
0.250

0.200

0.150

0.100

0.050

0.000
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
unit strain

Dari test didapat qu = 0.265 kgf/cm2


H
NAAN
ANG
6 Malang 65145

0.9 1
LABORATORIUM MEKANIKA TANAH
FAKULTAS TEKNIK SIPIL DAN PERENCANAAN
INSTITUT TEKNOLOGI NASIONAL MALANG
Jl. Bendungan Sigura-gura No. 2 Telp. (0341) 551951 – 551431 Psw. 256 Malang 65145

UNCONFINED COMPRESSION TEST


Location Err:540 Site :
Sample type : Buatan (remolded) Code Err:540
Depth Err:540 Sample No. : U2
Sample Data : Area (A0) = 10.70 cm2 Height (L0) = 6.99 cm
w = 26.31 % gd = 1.37 gr/cm3
Machine Data : LRC = 1.42 kgf Diameter = 3.69 cm
deformation load dial DL unit strain area CF corrected total load sample
dial reading (units) col 1 . 10-2 DL / Lo 1 - col 4 area A' on sample unit load
1 2 3 4 5 6 7 8
25.00 0.2 0.25 0.036 0.964 11.095 0.284 0.026
50.00 0.3 0.50 0.072 0.928 11.523 0.426 0.037
75.00 0.4 0.75 0.107 0.893 11.984 0.497 0.041
100.00 0.4 1.00 0.143 0.857 12.484 0.568 0.045
150.00 0.7 1.50 0.215 0.785 13.621 0.994 0.073
200.00 0.9 2.00 0.286 0.714 14.986 1.207 0.081
250.00 1.0 2.50 0.358 0.642 16.655 1.420 0.085
300.00 1.2 3.00 0.429 0.571 18.742 1.704 0.091
350.00 1.3 3.50 0.501 0.499 21.427 1.846 0.086
400.00 1.4 4.00 0.572 0.428 25.011 1.988 0.079
450.00 1.4 4.50 0.644 0.356 30.033 1.988 0.066
500.00 1.5 5.00 0.715 0.285 37.579 2.130 0.057
600.00 1.8 6.00 0.858 0.142 75.537 2.556 0.034
700.00 1.9 7.00 1.001 -0.001 -7478.157 2.698 0.000
800.00
900.00
1000.00
1100.00
1200.00
1300.00
1400.00
1500.00
1600.00
1700.00
sam ple unit load (kgf/cm 2)

0.100
0.090 0.0909175928133068
0.080
0.070
0.060
0.050
0.040
0.030
0.020
0.010
0.000 27
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
unit strain

Dari test didapat qu = 0.091 kgf/cm2


LABORATORIUM MEKANIKA TANAH
FAKULTAS TEKNIK SIPIL DAN PERENCANAAN
INSTITUT TEKNOLOGI NASIONAL MALANG
Jl. Bendungan Sigura-gura No. 2 Telp. (0341) 551951 – 551431 Psw. 256 Malang 65145

UNCONFINED COMPRESSION TEST


Location : Ds. Argotirto, Sumbermanjing, Malang Site : Lab. Mekanika Tanah ITN
Sample type : Fiberglass Code : FG
Depth : 1,5 m Sample No. : 1%
Sample Data : Area (A0) = 11.29 cm2 Height (L0) = 6.91 cm
w = 19.49 % gd = 1.69 gr/cm3
Machine Data : LRC = 1.42 kgf Diameter = 3.79 cm
deformation load dial DL unit strain area CF corrected total load sample
dial reading (units) col 1 . 10-2 DL / Lo 1 - col 4 area A' on sample unit load
1 2 3 4 5 6 7 8
25.00 0.5 0.25 0.036 0.964 11.710 0.710 0.061
50.00 1.0 0.50 0.072 0.928 12.166 1.420 0.117
75.00 1.4 0.75 0.109 0.891 12.660 1.988 0.157
100.00 1.8 1.00 0.145 0.855 13.196 2.556 0.194
150.00 2.5 1.50 0.217 0.783 14.415 3.550 0.246
200.00 3.6 2.00 0.289 0.711 15.883 5.112 0.322
250.00 5.0 2.50 0.362 0.638 17.684 7.100 0.401
300.00 6.4 3.00 0.434 0.566 19.945 9.088 0.456
350.00 8.1 3.50 0.507 0.493 22.870 11.502 0.503
400.00 10.1 4.00 0.579 0.421 26.800 14.342 0.535
450.00 12.5 4.50 0.651 0.349 32.360 17.750 0.549
500.00 15.5 5.00 0.724 0.276 40.831 22.010 0.539
600.00 20.3 6.00 0.868 0.132 85.700 28.826 0.336
700.00 25.4 7.00 1.013 -0.013 -866.520 36.068 -0.042
800.00
900.00
1000.00
1100.00
1200.00
1300.00
1400.00
1500.00
1600.00
1700.00
sam ple unit load (kgf/cm 2)

2.00
1.80
1.60
1.40
1.20
1.00
0.80
0.60 26
0.40
0.20
0.00
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
unit strain

Dari test didapat qu = 0.5485 kgf/cm2


LABORATORIUM MEKANIKA TANAH
FAKULTAS TEKNIK SIPIL DAN PERENCANAAN
INSTITUT TEKNOLOGI NASIONAL MALANG
Jl. Bendungan Sigura-gura No. 2 Telp. (0341) 551951 – 551431 Psw. 256 Malang 65145

UNCONFINED COMPRESSION TEST


Location : Ds. Argotirto, Sumbermanjing, Malang Site : Lab. Mekanika Tanah ITN
Sample type : Fiberglass Code : FG
Depth : 1,5 m Sample No. : 1,5%
Sample Data : Area (A0) = 11.05 cm2 Height (L0) = 7.31 cm
w = 19.24 % gd = 1.41 gr/cm3
Machine Data : LRC = 1.42 kgf Diameter = 3.75 cm
deformation load dial DL unit strain area CF corrected total load sample
dial reading (units) col 1 . 10-2 DL / Lo 1 - col 4 area A' on sample unit load
1 2 3 4 5 6 7 8
25.00 1.4 0.25 0.034 0.966 11.440 1.988 0.174
50.00 2.3 0.50 0.068 0.932 11.860 3.266 0.275
75.00 3.9 0.75 0.103 0.897 12.312 5.538 0.450
100.00 5.2 1.00 0.137 0.863 12.800 7.384 0.577
150.00 8.0 1.50 0.205 0.795 13.902 11.360 0.817
200.00 11.1 2.00 0.274 0.726 15.211 15.762 1.036
250.00 13.7 2.50 0.342 0.658 16.792 19.454 1.159
300.00 15.8 3.00 0.410 0.590 18.740 22.436 1.197
350.00 17.4 3.50 0.479 0.521 21.199 24.708 1.166
400.00 19.0 4.00 0.547 0.453 24.402 26.980 1.106
450.00 21.0 4.50 0.616 0.384 28.743 29.820 1.037
500.00 22.3 5.00 0.684 0.316 34.965 31.666 0.906
600.00 24.3 6.00 0.821 0.179 61.656 34.506 0.560
700.00 26.5 7.00 0.958 0.042 260.545 37.630 0.144
800.00
900.00
1000.00
1100.00
1200.00
1300.00
1400.00
1500.00
1600.00
1700.00
sam ple unit load (kgf/cm 2)

2.00
1.80
1.60
1.40
1.20 26
1.00
0.80
0.60
0.40
0.20
0.00
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
unit strain

Dari test didapat qu = 1.1972 kgf/cm2


LABORATORIUM MEKANIKA TANAH
FAKULTAS TEKNIK SIPIL DAN PERENCANAAN
INSTITUT TEKNOLOGI NASIONAL MALANG
Jl. Bendungan Sigura-gura No. 2 Telp. (0341) 551951 – 551431 Psw. 256 Malang 65145

UNCONFINED COMPRESSION TEST


Location : Ds. Argotirto, Sumbermanjing, Malang Site : Lab. Mekanika Tanah ITN
Sample type : Fiberglass Code : FG
Depth : 1,5 m Sample No. : 2%
Sample Data : Area (A0) = 10.81 cm2 Height (L0) = 6.91 cm
w = 19.12 % gd = 1.64 gr/cm3
Machine Data : LRC = 1.42 kgf Diameter = 3.71 cm
deformation load dial DL unit strain area CF corrected total load sample
dial reading (units) col 1 . 10-2 DL / Lo 1 - col 4 area A' on sample unit load
1 2 3 4 5 6 7 8
25.00 2.2 0.25 0.036 0.964 11.221 3.124 0.278
50.00 3.6 0.50 0.072 0.928 11.658 5.112 0.438
75.00 6.4 0.75 0.109 0.891 12.131 9.088 0.749
100.00 8.5 1.00 0.145 0.855 12.645 12.070 0.955
150.00 13.5 1.50 0.217 0.783 13.813 19.170 1.388
200.00 18.6 2.00 0.289 0.711 15.220 26.412 1.735
250.00 22.3 2.50 0.362 0.638 16.945 31.666 1.869
300.00 25.1 3.00 0.434 0.566 19.112 35.642 1.865
350.00 26.7 3.50 0.507 0.493 21.915 37.914 1.730
400.00 27.8 4.00 0.579 0.421 25.680 39.476 1.537
450.00 29.4 4.50 0.651 0.349 31.008 41.748 1.346
500.00 29.1 5.00 0.724 0.276 39.125 41.322 1.056
600.00 28.2 6.00 0.868 0.132 82.120 40.044 0.488
700.00 27.5 7.00 1.013 -0.013 -830.325 39.050 -0.047
800.00
900.00
1000.00
1100.00
1200.00
1300.00
1400.00
1500.00
1600.00
1700.00
sam ple unit load (kgf/cm 2)

2.00
26
1.80
1.60
1.40
1.20
1.00
0.80
0.60
0.40
0.20
0.00
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
unit strain

Dari test didapat qu = 1.8687 kgf/cm2


LABORATORIUM MEKANIKA TANAH
FAKULTAS TEKNIK SIPIL DAN PERENCANAAN
INSTITUT TEKNOLOGI NASIONAL MALANG
Jl. Bendungan Sigura-gura No. 2 Telp. (0341) 551951 – 551431 Psw. 256 Malang 65145

UNCONFINED COMPRESSION TEST


Location : Ds. Argotirto, Sumbermanjing, Malang Site : Lab. Mekanika Tanah ITN
Sample type : Fiberglass Code : FG
Depth : 1,5 m Sample No. : 2,5%
Sample Data : Area (A0) = 10.76 cm2 Height (L0) = 7.10 cm
w = 22.01 % gd = 1.66 gr/cm3
Machine Data : LRC = 1.42 kgf Diameter = 3.70 cm
deformation load dial DL unit strain area CF corrected total load sample
dial reading (units) col 1 . 10-2 DL / Lo 1 - col 4 area A' on sample unit load
1 2 3 4 5 6 7 8
25.00 2.1 0.25 0.035 0.965 11.149 2.982 0.267
50.00 3.1 0.50 0.070 0.930 11.571 4.402 0.380
75.00 5.2 0.75 0.106 0.894 12.027 7.384 0.614
100.00 7.2 1.00 0.141 0.859 12.520 10.224 0.817
150.00 10.6 1.50 0.211 0.789 13.638 15.052 1.104
200.00 14.2 2.00 0.282 0.718 14.975 20.164 1.347
250.00 17.1 2.50 0.352 0.648 16.602 24.282 1.463
300.00 19.8 3.00 0.423 0.577 18.627 28.116 1.509
350.00 21.6 3.50 0.493 0.507 21.214 30.672 1.446
400.00 23.0 4.00 0.563 0.437 24.636 32.660 1.326
450.00 25.1 4.50 0.634 0.366 29.373 35.642 1.213
500.00 26.1 5.00 0.704 0.296 36.367 37.062 1.019
600.00 26.3 6.00 0.845 0.155 69.428 37.346 0.538
700.00 26.5 7.00 0.986 0.014 763.706 37.630 0.049
800.00
900.00
1000.00
1100.00
1200.00
1300.00
1400.00
1500.00
1600.00
1700.00
sam ple unit load (kgf/cm 2)

2.00
1.80
1.60
26
1.40
1.20
1.00
0.80
0.60
0.40
0.20
0.00
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
unit strain

Dari test didapat qu = 1.5094 kgf/cm2


LABORATORIUM MEKANIKA TANAH
FAKULTAS TEKNIK SIPIL DAN PERENCANAAN
INSTITUT TEKNOLOGI NASIONAL MALANG
Jl. Bendungan Sigura-gura No. 2 Telp. (0341) 551951 – 551431 Psw. 256 Malang 65145

UNCONFINED COMPRESSION TEST


Location : Ds. Argotirto, Sumbermanjing, Malang Site : Lab. Mekanika Tanah ITN
Sample type : Fiberglass Code : FG
Depth : 1,5 m Sample No. : 3%
Sample Data : Area (A0) = 10.76 cm2 Height (L0) = 7.23 cm
w = 24.78 % gd = 1.65 gr/cm3
Machine Data : LRC = 1.42 kgf Diameter = 3.70 cm
deformation load dial DL unit strain area CF corrected total load sample
dial reading (units) col 1 . 10-2 DL / Lo 1 - col 4 area A' on sample unit load
1 2 3 4 5 6 7 8
25.00 1.9 0.25 0.035 0.965 11.142 2.698 0.242
50.00 2.5 0.50 0.069 0.931 11.556 3.550 0.307
75.00 4.0 0.75 0.104 0.896 12.001 5.680 0.473
100.00 5.9 1.00 0.138 0.862 12.483 8.378 0.671
150.00 7.6 1.50 0.207 0.793 13.572 10.792 0.795
200.00 9.8 2.00 0.277 0.723 14.870 13.916 0.936
250.00 11.9 2.50 0.346 0.654 16.442 16.898 1.028
300.00 14.5 3.00 0.415 0.585 18.385 20.590 1.120
350.00 16.4 3.50 0.484 0.516 20.850 23.288 1.117
400.00 18.1 4.00 0.553 0.447 24.077 25.702 1.067
450.00 20.8 4.50 0.622 0.378 28.487 29.536 1.037
500.00 23.0 5.00 0.692 0.308 34.874 32.660 0.937
600.00 24.3 6.00 0.830 0.170 63.227 34.506 0.546
700.00 25.5 7.00 0.968 0.032 338.126 36.210 0.107
800.00
900.00
1000.00
1100.00
1200.00
1300.00
1400.00
1500.00
1600.00
1700.00
sam ple unit load (kgf/cm 2)

2.00
1.80
1.60
1.40
1.20
26
1.00
0.80
0.60
0.40
0.20
0.00
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
unit strain

Dari test didapat qu = 1.1199 kgf/cm2


Ku at Tek an B eb as (k N/m ²)

Perbandingan Nilai Kuat Tekan Bebas (qu) dengan Penam-


bahan Bahan Campuran
2.0
1.8
1.869
f(x) = − 395170.782601371 x³ + 15346.7017976305 x² − 78.0016888264351 x
1.6 + 0.252229474162606
1.4 R² = 0.947865265318547
1.509
1.2
1.0 1.197
1.120
0.8
0.6
0.4 0.549
0.2
0.265
0.0
0.0% 0.5% 1.0% 1.5% 2.0% 2.5% 3.0% 3.5%
Prosentase Penambahan Bahan Campuran

You might also like