You are on page 1of 2
ELECTRONIC ENTERPRISES (INDIA) PVT. LTD. PARA ELECTRONICS ~ MANUFACTURING DIVISION Unit 306, Nimesh Industrial Estate, 90 Feet Cross Road, Mulund (East) , Mumbai, - 400 081. India Phone : 91-022-2563 5600) 91-022-2563 2741 Fax : 91-022-2563 7835 Email; pe.servicing@ecipLin Website: www ceipl.in Certificate No. SER/14-15/055, Date: 29.11.2014 CALIBRATION CERTIFICATE This is to certify that, Plating Thickness Tester, Model SIDET Sr. No. 2004317 including Pump Unit and with Rubber Gasket with etching hole Average diameter 2.40 is calibrated against Kocour USA make Plating Thickness Standard, Nickel on Steel; Sr. No. Ni-52695. This Nickel Plating Standard is manufactured by Kocour Company Inc. Chicago, USA and is traceable to National Institute of Standard and Technology, USA. Following are the calibration results: Standard Thickness Measured Thickness 13.3 Microns + 5% 13.23 Mierons Calibration Results are well within specifications of SIDET and are sat ‘Next Calibration is due on 29.11.2015 For ELECTRONIC ENTERPRISES (1) PVT. LTD. PARA ELECTRONICS ~ MANUFACTURING DIVN. Authorized Signatory Registered Office Electronic Enterprises (I) Prt. Lid, 215-216, Regal Indusrial Estate, Acharya Donde Marg, Sewri, Mumbai, 400 015 Phone : 91-22-241370%6 /91-022-24147970 Fax : 91-022-24133341 / 91-022-24153894 Email : spihale@eeipl.in COMPANY: Electronic Enterprises (I) Pvt 14 August 2014 KOCOUR ORDER #: 101774 CERTIFICATION Serial #: Ni-52695 COATING # 1: Nickel ‘THICKNESS: 0.52 MIL: 13,3 um OVER COATING # 2: ‘THICKNESS: OVER COATING #3:_ THICKNESS: OVER SUBSTRATE: Stee! ‘This certifies that the above Kocour thickness standard was prepared at ambient temperature by the weight/area method and was weighed on a Mettler Semi-Micro Analytical Balance, Model AE-163, Serial Number E-13040, having weights within Class "E2" tolerances ‘of the National Institute of Standards and Technology (NIST). It is further certified that this balance was calibrated on 08 January 2014, and is due for re-calibration in January, 2015 by the Mettler Instrument Corporation. This service includes accuracy test with Mettler test weights # 43 calibrated on 13 March 2013 traceable to the National Institute of Standards and Technology (NIST) # MTSO61 and if required, adjustments made to original specifications. This standard isa consumable item and cannot be re-calibrated or re-certified. The calibration and re-calibration dates listed above reference the certifying balance only. Kocour Company Brrer 8 PRA, Bruce L. Polak Labertory Mesagic KOCOUR COMPAKY INC, 4800 SOUTH ST. LOUIS AVENUE - CHICAGO, E0532 USA TEL (79) 7-111 AX (73) 847080

You might also like