A8500 Anesthesia Machine A8500 Anesthesia Machine Technical Specification ‘Physical & Environment Speciiations, Venter Spectications + Dimensions(WxHxD}: __800mm*1300mm*6a0mm + Driven Mode: Pnoumatically driven and electronically (without YOKE) ‘controlled + Weight 4100kg (basic unit) + Patient Types: Adult and Pediatric populations weighing © Operation Temperature: +10-+40°C above 2k9 + Operation Humidity. 80% (noncondensing) + Ventilation Modes: IPPY, POV, SIMV+PS, PS and Manual = Storage Temperature: __-20-+60°C + Setting Modes: Touch key & navigator wheel knob + Storage Humidity: 95% (noncondensing) Tidal Volume: 2 600m! “lecricalSpecticatons * Ventilation Frequency: 41006m + Mains: 100~240V AC, S0/6OH2 + KE Ratio 41-08 + Battery 24V_4An, minimum 120 rin + Pressure (inspired) Range: 6-700mH.0 + Outlets ‘on back, 1.6A individual + Pressure (support) Range: 3-S0emH:0 Pneumatic Specifications + PEEP: Off, 8-80 erntO + Gas Supply: Ar, Os, NO; 260KPa ~ 600kPa + Tslope 0-25, + Flowmeters: O2 Range: 0~1Lmin; 1~10L/min + Inspiratory Plateau: Off, %~60%T1 N:O Range: 0~1L/min; 1~10L/min + Thgger Sensitimty: 1~16Umin ‘Air Range: O- 1L/min; 1~12L/min + Compensation: Compliance and leakage compensation, ‘Auxiliary ©. Range: 0 ~12Umin Flowmeter backlight + Gas System: Oxygen supply failure alarm fresh gas compensation, allitude compensation ‘Ventilator Specification + Display: 10.4" TFT color screen ‘Oxygen supply failure protection + Pressure! Par Pont, Post, Pran, PEEP. (© flush: 26-76LImin + Volumes: MV, Vt Freq ~ AGGO include auxiliary common gas outlet _ + Gas: FiO, eptional: CO, AG, MAC > AGS: include anesthetic gas scavenging system _+ Graph Display: Pt, Ft, P-, F-V and optional GOs t ‘Breathing System Specifications + Alarm: High Arway Pressure/Low Arway Pressure + Operational Modes: Closed, Semi-closed, Sem-open Sustaned arway pressure + 00; Canister, 2 Loose fil GL) or 2 prepacks High Minute Volume/Low Minute Volume ‘optional single canister ‘APL Range: Spontaneous breathing (SP) -70 omHO + Matenal: pressure gauge] + Heating system: include Autoclavable (except O: cell and mechanical High FiOw/Low FiO. High Breath Rate 2 Supply failure Power failure ‘Apnea Alarm + OO; bypass: Optional Diproduksi oleh: PT.Enesers Mitra Berkah Taman Tekno Blok K2 No.12 Sektor XI BSD City Kel. Setu Kota Tangerang Selatan 15314 Banten - Indonesia Tip: +6221 7566360 Fax: +6221 7566361 email: info@enesers.com ‘Alarm Silence: 110 seconds: Vaporizer + Support two vaponizers + Agent: Halothane, Enflurane, Isoflurane, Sevoflurane installation Mode: Selectateo® with interlock, optional ‘standby vaporizer parking holder * Filing Type: Pour Fil, Key Fil, Quik-Fil ~ Vaporizers Include one vaporizes. (Halothane, Enflurance,

You might also like