Case study—Solder pallet cleaning: 50% cost reduction

Case study—
4PMEFSQBMMFUDMFBOJOH
50% cost reduction
By changing to a modern maintenance cleaning agent, Lenze Corporation, a specialist in drive and
automation technology, was able to realize enormous cost savings and to increase process reliability.
How? The following case study shows the way.

was intended to remove all contaminants


from the solder pallets in a low-cost, user-
friendly process.

8FBLOFTTFTPGUIFPSJHJOBM
DMFBOJOHQSPDFTT
The solder pallets are cleaned in a one-
chamber spray-in-air system (Figure 2).
The cleaning medium used at first, how-
ever, showed a few disadvantages in the
ongoing process.
In particular, the high operating costs
that the process caused were the main
Figure 1: Cleaning machine being loaded problem. The old cleaning agent had a
by Peter Ringe. short bath life, which meant that the bath
had to be changed after just 100 cleaning
cycles. Because the cleaning medium had
Lenze is a global corporation with over
to be run at a concentration of 20% or
60 years of experience and about 40 sales Figure 2. Process scheme of the current
more in order to achieve acceptable clean-
companies, development locations and one-chamber spray-in-air system with two
ing results, changing the bath was expen- tanks.
production facilities in Europe, Asia and
sive. In addition, the cleaning results were
America. The corporation, headquartered
not satisfactory, especially as the system
in Hameln, Germany, develops, manufac-
did not reliably remove all flux residues 3FRVJSFNFOUTGPSUIFOFX
tures and sells innovative products, exten-
sive solutions and complete systems for
from the solder pallets. QSPDFTT
Besides the cost for the fresh clean- Due primarily to the high operating costs
machine and plant construction. Drive
ing agent, additional costs ocurred for a and the low level of user-friendliness,
and automation technologies from Lenze
defoaming additive that was unavoidably Lenze decided to replace the old clean-
set things in motion—conveyors, robotics
needed due to the severe foaming of the ing process. In addition to cost reduction
and handling systems, as well as packaging
cleaner. and improved technical application fac-
technologies in the sectors of intralogistics,
There were also a number of technical tors, Lenze hoped to improve the clean-
automotive and foodstuffs, for example.
application problems in the process, such ing results as well. Thus, the new cleaning
The electronic assemblies used in these
as a recurring bad odor from the machine agent had to completely remove the baked-
systems are produced by Lenze itself at the
that often disturbed the operators of the on flux residues from the solder pallets.
company’s location in Aerzen, Germany. In
cleaning machine. The odor was caused by But since the existing cleaning equipment
order to ensure a reliable wave-soldering
the rapid buildup of microbes in the rinse had to remain in use, the material compat-
process for the assemblies, the used solder
water. ibility of the new cleaning agent with the
pallets must be cleaned automatically and
Additionally, it was also very difficult machine’s construction materials also had
on a regular basis. Otherwise the flux resi-
to monitor the quality of the cleaning bath to be ensured.
dues on the pallets could cause the assem-
because it could only be controlled super- Additional requirements for the new
blies to tilt. This can lead to bad soldering
ficially by measuring the pH-value of the cleaning process, determined from experi-
results, or even production defects that
cleaner. It was impossible to determine ence and by examining previous process
need to be selectively reworked.
other important parameters, such as the problems, were as follows:
Therefore, as a preventive measure, the
current cleaner concentration in the clean-
corporation installed an automated clean- t Increase the bath life of the
ing bath.
ing process some time ago (Figure 1). It cleaning agent and the number

28 – Global SMT & Packaging – January 2011 www.globalsmt.net


Case study—Solder pallet cleaning: 50% cost reduction

compatibility of different maintenance


cleaning agents was tested in jointly con-
ducted material compatibility tests. The
cleaning agent Atron SP 200 was ultimately
determined to be 100% compatible with
Figure 3. Solder pallet with flux contaminants before cleaning (L) and after cleaning (R). the materials in the interior of the clean-
ing machine, particularly with the plastic
materials predominantly used. Therefore, it
was possible to change the cleaning agent
while continuing to use the existing clean-
ing machine.

*NQSPWFEVTFSGSJFOEMJOFTT
and cost reduction
In the cleaning trials, the new cleaning
agent provided excellent results even at
a concentration of only 10% (Figure 3).
Figure 4. Comparison of the molecular structure and contaminant bonding capacities: con- The complete removal of all flux residues
ventional surfactant cleaner (L) and FAST cleaning medium (R). from the solder pallets was achieved. This
ensures that the assemblies can be properly
of cleaning cycles t Increase user friendliness by secured for the downstream wave-solder-
t Ideally, be able to use a lower reducing odor issues ing process.
application concentration t Completely remove flux resi- Despite the low concentration, the
t Increase the ability to monitor dues from the solder pallets number of cleaning cycles could be
the cleaning bath in order to increased from 100 to over 170 cycles with
With this list of requirements in hand, the new cleaning medium.
achieve a stable process
Lenze contacted Zestron to evaluate a suit- This is due to the FAST® Technology,
t Prevent foaming without the
able cleaning agent. which the new cleaning agent is based on.
use of additional defoaming
Before changing the cleaning bath, the Compared to conventional surfactant sys
additives

30 – Global SMT & Packaging – January 2011 www.globalsmt.net


Case study—Solder pallet cleaning: 50% cost reduction

tems, this type of cleaning agent can bond 1SFWJPVTDMFBOJOHQSPDFTT $VSSFOUDMFBOJOHQSPDFTT


to more contaminant particles, which in
Bath life Change bath after 100 Change bath after 170
turn leads to a significant extension of the
cycles cycles
bath life (Figure 4).
By cutting the concentration in half, Cleaning agent concentration ≥20 % 10 %
from 20% to 10%, and at the same time Rinse water change Daily, 5 times per week About twice per week
nearly doubling the bath life, more than Water consumption 375 liters per week 187.5 liters per week
50% of the operating costs could be saved. Solder pallet cleaning results Some flux residue remaining Flux residue completely
In contrast to the previous cleaner, the removed
new cleaning medium did not cause any
problems with foaming in the cleaning Defoamer Yes No
machine. An additional defoaming additive Odor Strong odor Mild odor
thus became unnecessary, which in turn Bath monitoring Only pH measurement pH measurement and clean-
lowered the operating costs. ing agent concentration
The use of the new cleaner also pro- Total cost savings None 56%
vided the desired technical advantages,
as the rinse water no longer showed any Table 1. The comparison shows significant improvements due to the new cleaning process.
microbe buildup. Thus, the offensive odor
was reduced for the operator of the clean- quick and easy to handle chemical tests nificant overall cost savings due to a longer
ing process, and the previously daily change from Zestron. bath life and a lower application concentra-
of the rinse water was no longer neces- tion, while simultaneously increasing pro-
sary. Altogether, water consumption was cess stability with improved bath monitor-
reduced from 375 liters per week to half of
Summary
Working together with Zestron, Lenze ing.
that amount. Since November 2008, the new cleaning
was able to evaluate a new cleaning agent
Last but not least, the change of the process has been running at Lenze onsite in
that fully met all requirements. Simply by
cleaning agent had a positive effect on pro- Gross Berkel, Germany, to the complete sat-
replacing the cleaning agent in the existing
cess stability. In addition to automatically isfaction of the electronics manufacturing
cleaning machine, the weaknesses of the
measuring the pH-value of the rinse water, team.
old process were fixed.
the cleaning agent concentration can now
The new cleaning process provided sig-
be determined directly at the site using

www.globalsmt.net Global SMT & Packaging – January 2011 – 31