You are on page 1of 1

SOIL SCREW RETENTION WALL SYSTEM

TM

-NOTES-
1. HOT DIP GALVANIZED PER ASTM A153-(LATEST REV.)
2. LEAD AND EXTENSION SECTION LENGTHS AND HELIX SPACINGS ARE NOMINAL,
ALLOWABLE TORQUE CAPACITY - 5,500 FT-LBS. EXPECT SOME VARIANCE.
3. MANUFACTURER TO HAVE IN EFFECT INDUSTRY RECOGNIZED WRITTEN QUALITY

ULTIMATE TENSION STRENGTH OF ANCHORS - 70,000 LBS. CONTROL FOR ALL MATERIALS AND MANUFACTURING PROCESSES.
4. ALL WELDING TO BE DONE BY WELDERS CERTIFIED UNDER SECTION 5 OF THE
AWS CODE D1.1.

3" PITCH

HELIX MUST BE FORMED BY MATCHING METAL DIE


(SIDE VIEW OF TRUE HELICAL FORM)

SOLID STEEL
SQUARE BAR

17
20
23
24

53 SOLID STEEL
78 1 SQUARE BAR 80 57

37

6 5

COUPLING BOLT
C110-0692 C110-0691 C12655 C110-0689 AND NUT C110-0690
TWIN HELIX TRIPLE HELIX PLAIN TRIPLE HELIX TWIN HELIX
LEAD LEAD EXTENSION EXTENSION EXTENSION
SECTION SECTION

CONFIDENTIAL: THIS DRAWING AND ITS CONTENTS ARE CONFIDENTIAL AND THE EXCLUSIVE

COPIES MAY BE MADE WITHOUT WRITTEN CONSENT BY HUBBELL / A.B. CHANCE COMPANY.
C 2000 HUBBELL/A.B. CHANCE. UNPUBLISHED - ALL RIGHTS RESERVED UNDER THE COPYRIGHT LAWS
HELICAL LEAD

PROPERTY OF HUBBELL / A.B. CHANCE COMPANY. NO PUBLICATION, DISTRIBUTION OR


EXTENSION SECTION

ANCHOR
SHAFT
8
21 TYPICAL ANCHOR ASSEMBLY
8

13

5" X 3/4" PIN LATEST EC NO: REV. DATE CHANGED BY RESP ENGINEER

97081208 - -------- ------ HOYT

PLATE PLATE
PE150-0088 CT110-0671
TM
QUALLS 08-13-97 SOIL SCREW RETENTION WALL SYSTEM
R DWG NO:
CAE
POWER SYSTEMS, INC. CAD
CAM SA110-10031
SH 01
OF 03