You are on page 1of 2

(Casting Systems)

Resin HCLR 1329/Hardener HCLH 5100


Product Description A Two Component Heat Cured Epoxy product passes accelerated
In-house ultra violet testing Without chalking. Product pass In-
House UL 94-HB flammability testing.

Applications & Key Casting system cured product is suitable for outdoor application.
Properties
Product Specifications
Reference Value
Properties Units
Standard HSC 1329 HSC 5100
Appearance Visual HTP-1 Grey Paste Amber Liquid
Specific Gravity gm/cm³ ASTM D891 1.85 ± 0.03 1.10 ± 0.02
10000-20000 @
Viscosity mPas ASTM D2196 100-300 @ 22˚C
65˚C

Product Performance Data


Reference
Properties Units Value
Standard
Mixing Ratio (R:H) Pbw NA 100:23
Mix Viscosity @ 60ºC mPas ASTM D2196 500
Gel time 200 gm @ Minutes HTP-17 24
100ºC
Recommended Cure NA NA 4h @125ºC
Schedule
Optional Post Cure NA NA 2h @150ºC

Cured Properties
Tensile Strength MPa ASTM D638 64.81
Linear Shrinkage in/in ASTM D2566 0.0094
Tensile Elongation % ASTM D638 3.4
Shore Hardness Shore D HTP-22 90D
Density gm/cm³ ASTM D792 1.70
HDT °C ASTM D648 100

HTP: HSCL Testing


Procedure

Processing and Storage


HSCL/TDS/06 Version 00 Sep 2019 Page 1 of 2
Packaging HCLR 1329 available 30 kg in metal container and HCLH 5100 are available
7 kg in metal container.

Mixing Mix ratio must be within ±2% of the stated amount and thorough mixing is
required to avoid degraded final properties.
Curing Other cure schedules may give satisfactory results; however, these should be
determined by the customer for their given circumstances
Storage These products may trigger allergic responses in some individuals. Prevent
Conditions contact with skin, wash with plenty of soap and water immediately if contact
occurs. Do not breathe vapours, provide good ventilation and exercise good
housekeeping at work area. Read the Material Safety Data Sheet.
If a filled resin, setting may occur during transportation or storage. Fillers
must be remixed before use.
If filled resin, settling may occur during transportation or storage. Filler must
be remixed before use.
Products has 12- month of shelf life.

Disclaimer All recommendations for use of our products, whether given by us in


writing, verbally or to be implied from results of tests carried out by us are
based on the current state of our knowledge. Notwithstanding any such
recommendations the Buyer shall remain responsible for satisfying himself
that the products as supplied by us are suitable for his intended process or
purpose. Since we cannot control the application, use or processing of the
products, we cannot accept responsibility. Therefore, the Buyer shall ensure
that the intended use of the products will not infringe any third party's
intellectual property rights. We warrant that our products are free from
defects in accordance with and subject to our general conditions of supply.

Marketing & Sales Office Works

Hindusthan Speciality Chemicals Limited Hindusthan Speciality Chemicals


65, Free Press House, Limited
Free Press Journal Road, Plot No.:830, GIDC,
Nariman Point, Mumbai – 400021 Jhagadia Industrial Estate,
Tel: +91 22 61510960 Jhagadia, Bharuch District,
Email- sales.hscl@hindusthan.co.in Gujarat – 393110, India
Website: www.hindusthanspeciality.com

HSCL/TDS/06 Version 00 Sep 2019 Page 2 of 2