Scale Factor = 1: 1.
428571429
Floor Tributary scaled Area surrounded by column in the selected frame
Length (scaled) of beam within the scaled Tributary area of the columns in the selected frame
Length (scaled) of infill walls within the scaled Tributary area of the columns in the selected frame
Thickness of slab = 6"
Concrete density
Size of Beam = 250 x 350 mm
Size of Column = 250 x 250 mm
Height of story
Live load on Roof As per Pakistan Building Code (PBC) 2007
Live load on Floor As per Pakistan Building Code (PBC) 2007
Floor Finishing load As per Pakistan Building Code (PBC) 2007
1- Load of Roof Slab
Live load on Roof as per Pakistan Building Code (PBC) 2007 (Live Load)
Self weight of Slab = Concrete density x Slab thickness (Dead Load)
Floor Finishing load as per Pakistan Building Code (PBC) 2007 (Dead Load)
water proofing as per Pakistan Building Code (PBC) 2007 (Dead Load)
Total Dead load on Roof slab
Factored load on Roof Slab i.e. Pakistan Building Code (PBC) 2007 = 1.2D+1.6L
2- Load of Floor Slab
Live load on Floor (Live Load)
Self weight of Slab = Concrete density x Slab thickness (Dead Load)
Floor Finishing load = Concrete density x Slab thickness (Dead Load)
Total load on Floor slab
Factored load on Floor Slab i.e. factor used as per ACI318-14 = 1.2D+1.6L
3-Self Load of Walls
Height (scaled) of infill walls= total height minus depth of beam
Density of bricks masonry used in Pakistan
Thickness of wall
Self weight of wall = density x thickness x height (Dead Load)
Factored load of infill walls [Link] per Pakistan Building Code (PBC) 2007 = 1.2D
4- Self Load of Beam
Self Load of Beam
factored load of beam i.e. as per Pakistan Building Code (PBC) 2007 = 1.2D
5- Self Load of Column
Self Load of Column
Factored load of Colum i.e. as per Pakistan Building Code (PBC) 2007 = 1.2D
Load on the selected column
Load from Roof to 2nd floor
Roof load = Tributary floor area (m^2) x Roof load in kN/m^2
Beam load = Beam length in (m) x Self load of beam in kN/m
Infill walls load = Infill walls length in (m) x Self load of infill walls in kN/m
Total
Load from 2nd floor to First floor
Floor load = Tributary floor area (m^2) x Floor load in kN/m^2
Beam load = Beam length in (m) x Self load of beam in kN/m
infill walls load = Infill walls length in (m) x Self load of infill walls in kN/m
Total
Cumulative load from top floor to first floor = 92.847+97.55
Load from First to Ground floor
Floor load = Tributary floor area (m^2) x Floor load in kN/m^2
Beam load = Beam length in (m) x Self load of beam in kN/m
infill walls load = Infill walls length in (m) x Self load of infill walls in kN/m
Column load with complete height i.e. 3 stories building height =
self load of colum x total height (scaled height)
Total
Cumulative load from top to ground floor = 109.36+190.399 = 299.7 kN
PS: Due to its symmetry 300 kN load acts on each column of selected portal frame
0.7
4.9 m^2
3.85 m
3.85 m
0.15 m
25 kN/m^3
3m
1.2 kN/m^2 As per UBC/PBC2007
2.4 kN/m^2 As per UBC/PBC2007
1.72 kN/m^2 As per UBC/PBC2007
1.2 kN/m^2
3.75 kN/m^2
1.72 kN/m^2
0.8 kN/m^2
6.27 kN/m^2
9.444 kN/m^2 Same load factors used as per ACI318-14 normal design practice in Pakistan
2.4 kN/m^2
3.75 kN/m^2
1.72 kN/m^2
5.47 kN/m^2
10.404 kN/m^2
1.855 m
18.5 kN/m^3
0.23 m
7.893025 kN/m
9.47163 kN/m Same load factors used as per ACI318-14 normal design practice in Pakistan
2.1875 kN/m
2.625 kN/m Same load factors used as per ACI318-14 normal design practice in Pakistan
1.5625 kN/m
1.875 kN/m Same load factors used as per ACI318-14 normal design practice in Pakistan
46.2756 kN
10.10625 kN
36.4657755 kN
92.8476255 kN
50.9796 kN
10.10625 kN
36.4657755 kN
97.5516255 kN
190.399251 kN
50.9796 kN
10.10625 kN
36.4657755 kN
11.8125 kN
109.3641255 kN
299.7633765 kN
e in Pakistan
e in Pakistan
e in Pakistan
e in Pakistan