You are on page 1of 4
Follow at DESIGN OF STEEL STRUCTURE 2018 23 Sep 2019 (Evening Session) 1, Cast iron is manufactured by re-melting — with coke and limestone. (a) Iron () Pigiron (c) Wrought iron (@) Cast iron Solution: (b) 2. Wind load analysis can be done by using: (a) IS 875 - part 1 (b) 1S 875 - part 3 (c) 1S 875 -part2 (4) 1 875 - part S Solution: (b) 875 Design loads (other than earieqaedyd® building & structures Part I : Dead load. Part Il: Live load Part III: Wind load, Part IV : Snow load Part V : Special loads & load combinations 3. A load value obtained by multiplying the characteristic load with load facto known as (a) Design spectrum (b) Fatigue load (©) Dead load (4) Designed load Solution: (a) 2018 23 Sep 2019 (Morning Session) 4. Which of the following is a fillet weld? (a) Single bevel (b) Miltre S.Sorout CIVIL Ki GOLI Facebook/Telegram (©) Square (@) Single J Solution: (b) 5. Surface in surtace is Mice Concave conven Types offi welds 2018 23 ep 2019 (Evening Session) ‘The minimum edge distance and end dis- tance from the centre of any hole to the net edge of plate for sheared or hand flame edge is (a) 1.5 times the diameter (b) 1.7 times the diameter (c) 1.9 times the diameter IL.Ki GOLA) 1.8 times the diameter Solution: (b) 1.5 times the diameter in case of machine cut end, 6. For inspection of welded joint, the method which iron fillings are spread over the weld and it is then subjected to an clec- tric current is known as: (a) Dye penetration method (b) Magnetic particle method (©) Ultrasonic method (d) Radiography method Solution: (b) 1, 2018 25 Sep 2019 (Morning Session) In a double riveted double covered butt joint the strength of the joint per piteh length shearing the rivets P, and strength of one rich in single shear P, are related (a) P,=2P, 9255624029 1 Follow at CIVIL Ki GOLI Facebook/Telegram maximum permissible length of the mem- (b) P= 25 P, ber? (© Py 3P, (Assume slenderness ratio = 350) @ Pa 4P, (a) 3000 mm Solution: (a) (b) 1750 mm (©) 2000 mm (@) 2500 mm Solution: (b) Maximum slenderness ratio for members acting as the in a roof truss on bracing system but subjected to possible reversal of load (2...) = 350, 8.As per IS 800 : 2007, what should be the m: i mum slenderness ratio for the tension ae members in which reversal stress due to load rather than wind or seismic forces (fr occurs? Fain = (a) 350 (b) 400 (©) 100 CIVIL Ki (a) 180 Solution: (a) Maximum slenderness ratio ‘Max slendemess ratio Types of men ‘tension member perman rently in tension except pretes~ 400 sioned member ich of the following is NOT a mode of failure in a tension member? ‘A member normally acting asa tien a oof truss oF bea ing system, But subjected to (a) Block shear failure possible reversal of stress resuti~ ba ng from the action of wind or (©) Gross section yielding carthquake forses (c) Net section rupture 7 tension member iv which reversal of direcet stress due to (@) Local buckling loads other than wind or earth i Solution: (a) 2018 2018 23 Sep 2019 (Morning Session) 25 Sep 2019 (Morning Session) 11. A steel built up column is subjected to an axial force of 1000 KN. The lacing system has to be designed for resisting a trans- verse shear of: 9. A steel rod of 20 mm diameter is used as a tie member in a roof br: and may be subjected to possible rever- sal of stress due to wind load. What is the (a) 30kN S.Sorout 9255624029 2 Follow at (b) 20kN (c) 25KN (a) ISKN Solution: (e) ‘Transverse shear is taken as 2.5% of axial loading 1000’ 2.5 100 *. Transverse shear = = 25KN 2018 23 Sep 2019 (Evening Session) 12. The lacing are subjected to resist a trans- verse shear of (a) 2.5% of axial force in the member (b) 2.75% of axial force in the member (c) 2.8% of axial force in the member (4) 2.25% of axial force in the member Solution: (a) Design of lacing 1. It is designed to resist a total trans beads equal to 2.5% the axial force in the column, (2.5% of P= V) IENo. of parallel is N (generally 2) then foree in : v lacing bar= ying v2 forsingle lacing 2018 25 Sep 2019 (Morning Session) 13. As per IS 800 : 2007 Maximum Effective Slenderness ratio for a member carrying compressive loads resulting from dead loads and imposed loads will be: (a) 250 (b) 350 (c) 400 (a) 180 S.Sorout CIVIL Ki GOLI Facebook/Telegram Solution: (d) Member “A member carrying compressive load resulting from dead load and imposed load | '8° Tha ‘A tension member in which reversal of direct stress due to load other than 180 wind and seismic force “A member subjected to compressive forces resulting from wind EQ force provide deformation of such member | 75° does not affect stress ‘Compression Mlange of Beam against Jaterial torsional buckling bad ‘A member normally act asa fie in Roof Truss itd {\ [Tension member other than Pre-tension | 400 2018 25 Sep 2019 (Morning Session) 14, The effective length of lateral buckling for a simply supported beam under normal loading conditions, provided torsional re- Ki GOL Nt filly restrained and warping re- Straint as both flanges fully restrained should be ————. (D - overall depth of beam L-length of span) (a) 0SL+D (b) 1.2L+2D (©) 0.7L (@) 0.95L Solution: (e) 2018 25 Sep 2019 (Morning Session) 15. The permissible maximum deflection of a purlin of 4.5 m which is subjected to live load supporting GI metal sheet and sup- ported by elastic cladding is: (a) 37.5 mm (b) 15mm. (c) 18.75 mm (@) 30mm. Solution: (4) As per IS 800 : 2007 table 6 9255624029 3 Follow at CIVIL Ki GOLI Facebook/Telegram Deflection of purlin and grit subjected to live load! wind 1 bed and supporting elastic cladding is 755 \. Maximum deftection= 25 10 - 39 mm 150 CIVIL Ki GOLI S.Sorout 9255624029

You might also like