You are on page 1of 7
TEST CERTIFICATE CENTRAL POWER RESEARCH INSTITUTE (A Govt. of India Society) Regional Testing Laboratory 3A, Institutional Area, Sector - 62 Noida - 201 309 Certificate No. CPRIRTLHV2016C063, Laboratory Ref: CPRI/RTL-NOIDA TYPE TEST CERTIFICATE FOR VERIFICATION OF TEMPERATURE RISE LIMITS TEST OBJECT —_ : 690V, 2500 A Non Segregated Phase Bus-Duct DESIGNATION __ : (180x8mm, 1No, /Phase Copper Bus-bar Bus-duct) € Rated Voltage: 690 V. Rated Current: 2500 A. Rated Frequency: SOHz MANUFACTURER: M's C&S Electric Lid.. BI, Site- IV,Surajpur Industrial Area. a Kasna Road. Greater Noids-201306 (U.P.) India. TESTED FOR 1 Mis C&S Electric Ltd, BI. Site- IV,Surajpur Industial Area. Kasi Road, Greater Noida-201306 (U.P.) India, DATE OF TESTS: 17.06.2016 VESTED BY Central Power Research Institute Regional Testing Laboratory Plot No. 3-A, Institutional Area ‘Sector-62, Noida(U.P.), Distt: Gautam-Buddhanagar( India) Tis test object. constructed in accordance with the description, drawings incorporated inthis certificate has been subjected to the © “tof Proving tess in accordance with ) CLNo.10.10 of IEC 61439-1/2011 & IEC 61439-6/2012 The test results are shown in record of Proving Tests. The values obtained and the general performance are considered to comply’ with the above standard(s) and to justify the ratings assigned by the manufacturer as listed on page no. ‘The certificate applies only to the test object. The responsibility for conformity of any equipment having the same designations with the tested rests with the manufacturer. comprises 5 sheets in total including front sheet nigral redaction of this enc, oF reproductions ofthis page acommpaied by any’ page(s on shied are sad the eds ‘ol the feat object. are penmitedsuthout sition pennssan fom Centr Power Rescroh Inte. Pm Sir C'S Raman Real 0 N06, Sadie (PO Bangle 0080 Authorized Signatory 08 AUG 2016 nawornae CENTRAL POWER RESEARCH INSTITUTE te No.CPRIRTLHW2016C063 Date: 17.06.2016 Ratings assigned by the manufacturer Vest Sample 690 V, 2500A Non Segregated Phase Bus-Duct ‘pe ‘Non Searegnted Phase Bus-Duct ignation 180x8mm, INo./Phase Copper Bus-bar Bus-duct Serial No. Nil Rated Voltages: Rated Operational Voltage (Ue): 690V Rated Insulation Voltage (Ui): 690V cated Curent Rated Operational Curtent (In): 25008, Rated Frequency (Hz) 50 No.of phases Thice + Neutral Ponta teronal material Copper ts on BusbarsTerminals: 50°C above ambient Temperature. its on Enclosure: 25°C above ambient Temperature. Note: 1) Maximum Temperature rise lit 2) Maximum Temperature ist ‘Tes Engibeer Sheet fof 4 rare fags agar Sea Fa BORER RESEARCH INTUTE CE Oe eh et nego ou, Fee $3 Inline Sa 190) CENTRAL POWER RESEARCH INSTITUTE Certificate No.CPRIRTLHV2016C063 Date: 17.06.2016 SUMMARY OF TEST est conducted on 690 V, 2500 Non Segregated Phase Bus-Duct having CPRI sample cade no. CPRIRTLHW201 6S074 Rating for which tested cation of Temperature Rise 2500 A Limits TOTO oFIEC 61439-72011 | &IEC 61439-62012 Document constituting this report Oscillogram Numbers: Nil Photograph numbers Nil Test circuit diagram number : Nil O Drawing numbers 2 €-19600815-21534 ROD ‘Test Eitziaber Sheet 2 oF + CENTRAL POWER RESEARCH INSTITUTE Certificate No.CPRIRTLHV2016C063 Date: 17.06.2016 Verification of Temperature Rise Limits (as per cl.no.10.10 of IEC 61439 part-1/201 1 & IEC 61439-6/2012) it conducted : Verification of Temperature Rise Limits Condition of the sample New Date of test 7.06.2016 Starting time (Hrs) Shut down time (Hrs) Test current (A) Size of the conductor used for : Bare Cu Bus-bars, 100x5 mm, 2.0 meter long feeding feeding and star end temporary connections end 4 Nos. per phase Frequency (Hz) 250 Phase 03 Avg. ambient temperature at shut down 35.0°C Arrangement of thermocouple locations: As per drawing no. C-1960-0815-21534 ROO a Thermocouples. Maximum Temperature Rise | Locations | Numbers | Temperature ec) Ce | corded(?C) | TL 715. a T2 79.8 44.8 B-Phase Bus-bar 3 75.9 40.9 Bus-bar Rigid Joint v4 779 42.9 ote hase Bus-bar Rigid Joint TS, 79.2. 44.2 ise Bus-bar Expansion Joint T6 79.0 44.0 | R-Phase Bus-bar 90° Bend 77 70.0 Bs One| ‘Y-Phase Bus-bar 90° Bend TS 69.2 __ 34.2 ia B-Phase Bus-bar 90° Bend To 93.500 | 7s Enclosure | Enclosure 8 a} Observation: The maximum temperature rise obtained was within the limits as per the requirements of the standard and customer. After test, sample subjected to the HV test. The sample withstood 3.5 kVrms for one minute, Conclusion: The test result indicate that the sample tested complies with the requirements of el. 10.10 of IEC: 61439-1/2011 & IEC 61439-6/2012. Test Engitteer Sheet 3 of 4 ARCH INSTITUTE saya Net STING! ABUNATORY al, 2t-C2, -AESI-20 1909 234 Instulional Area, Se2-62, Noda-201909 (UP) a) 6) 2 CENTRAL POWER RESEARCH INSTITUTE Certificate No.CPRIRTLHV2016C063 Date: 17.06.2016 NOTE ‘The test results relate only to the item(s) tested. Publication or reproduction of this reporticertficate in any form other than by complete set of whole teport and in the language written Any coreetion ‘ erasure invalidate this test report certificate, 1005 standard wide centificate no, T-2753 for the tests carried NABL has accredited this laboratory as per ISOEC 1702: out ‘The verification of the sample drawings by CPRI is limited to dimensional checks only wherever possible. Any anomaly /discrepaney in the test report / certificate should be brought to our notice within the 45 days from the date of CPRI issues to kinds of documents: Test Report: ‘The test report will contain the record of the values of test parameters as obtained during testing, the physical condition ofthe apparatus during testing, the physical condition of the apparatus duringafter the tes(s), copy(ies) ofthe oscillogramts). record of supplementary tests if any conducted but no certification on the performance ofthe apparatus tested. Type teat Centficate The test certificate is issued, on request and payment ofthe prescribed charges only when the apparatus of particular type and tating has satisfactorily passed all the specified tests in compliance with condition stipulated in a published National‘International Standards Test Engineer Sheet 4 off 18 fage siqeiert Vike RAL POWER RESEARCH INSTITUTE jyire aQeror searTeTeT REGIONAL TESTING LAGORATORY ‘eechegerra EY, Ett, TST-201909 3A. insttulenal Area, S222, Koxds-201909 (UP) | TEMPERATURE RISE TEST LAYOUT FOR 630V 25004 NSPED > TERRORS = {0 MEAGURE AUBIN TEUPERATURE TT) @ TEST ENGINEE’ Canes Pome NOIDA Petrofac) nD

You might also like