You are on page 1of 2
A8500 Anesthesia Machine 8500 Anesthesia Machine Physical & Environment Specifications + Dimensions(WxHXD): __800mm*1200mm*6GOmm Technical Specification Ventilator Specifications + Driven Mode: Pnoumatically driven and electronically (without YOKE) ‘controlled + Weight: 100kg (basic unit) + Patient Types: Adult and Pediatric populations weighing + Operation Temperature: +10-+40°C ‘above 2kg + Operation Humidity: "<80% (noncondensing) + Ventilation Modes: IPPV, PCV, SIMV+PS, PS and Manual + Storage Temperature: -20-+60°C + Setting Modes: Touch key & navigator wheel knob * Storage Humidity: <95% (noncondensing) Tidal Volume: 2 '500mI Electrical Specifications + Ventilation Frequency: 4~1005pm + Mains: 100~240V AC, 50/60Hz + FE Ratio 4-18 + Battory: 24V_4An, minimum 120 min + Pressure (inspired) Range: 6-700mH.O + Outlets: 3 on back, 1.6A individual . (support) Range: ¢-50emH:0 Peumatic Specifications : Off, 3-30 omH:0. + Gas Supply: Air, Ox, N:O; 280kPa ~ 600kPa + Tslope: 0-28 + Flowmeters: Oz Range: 0-1Uimin; 1~10L/min + Inspiratory Plateau: Of, 5%~60%T! N.O Range: 0-1L/min; 1~10L/min + Trigger Sensitivity: 1~15L/min ‘Air Range: O- 1L/min; 1=12L/min + Compensation: Compliance and leakage compensation, ‘Auxiliary O: Range: 0 ~12U/min fresh gas compensation, altitude compensation Flowmeter backlight Ventilator Specifications + Gas System: Oxygen supply failure alarm + Display: 10.4" TFT color screen ‘Oxygen supply failure protection + Preseure: Par, Pons, Po, Pres, PEEP (O: flush: 25-76L/min + Volumes: MV. Vt. Freq + AGGO: include auxiliary common gas outlet + Gas: FiO,, optional: CO., AG, MAC + AGSS: include anesthetic gas scavenging system + Graph Display: _P-t, Ft, P-V, F-V and optional 00s -t Breathing System Specifications + Alarm: High Airway Pressure/Low Airway Pressure + Operational Modes: Closed, Semi-closed, Semi-open Sustained airway pressure + 00: Canister: 2 Loose fil GL) or 2 prepacks, High Minute Volume/Low Minute Volume ‘optional single canister High FiO./Low FiOs ‘APL Range: Spontaneous breathing (SP) -70 omH.O High Breath Rate + Matenal Autoclavable (except O: cell and mechanical (©: Supply failure pressure gauge) + Heating system: include Power failure ‘Apnea Alarm + CO: bypass: Optional PT.Enesers Mitra Berkah Taman Tekno Blok K2 No.12 Sektor XI BSD City Kel. Setu Kota Tangerang Selatan 15314 Banten - Indonesia Tip: +6221 7566360 Fax: +6221 7566361 email: info@enesers.com enesers ‘Alarm Silence: 110 seconds Vaporizer + Support two vaponizers + Agent: Halothane, Enflurane, Isoflurane, Sevoflurane installation Mode: Selectatec® with interlock, optional standby vaporizer parking holder + Filing Type: Pour Fill, Key Fil, Quik-Fil «Vaporizers: Include one vaporizes. (Halothane, Enflurance, KEMENKES RI AKD 204037110668

You might also like