SP FLOW ® 380 is a polycarboxylate ether-based LCI recommends to add SP FLOW ® 380 in the concrete after superplasticizer and high range water reducer designed for batching water, by means of an automatic dosing device. use in concrete : For more information on safe handling, see the safety datasheet ▪Increased initial and long-time workability, high flowability, provided by LCI upon request. easier placement, ▪Improved concrete quality by high water reduction.
Benefits Technical information
▪Compressive strengths Appearance Transparent to slightly yellow liquid SP FLOW ® 380 allows to reduce batching water dosage by Specific gravity 1.075 +/- 0.015 at least 25% without loss of workability. With SP FLOW ® pH 6.0 +/- 1.0 380, the higher water reduction improves concrete density Chloride content < 0.10 % and reduced permeability while the early strength Alkali content < 1.0 % development results in shorter stripping times. Entrained air < 2% above control concrete
▪Concrete workability Compatibility
SP FLOW ® 380 significantly improves workability and SP FLOW ® 380 is compatible with other LCI admixtures, when flowability of the concrete at constant water/binder ratio. added separately. Trial tests are recommended. Highly fluid concrete can be expected after two hours, and ▪SP FLOW ® 380 can be used with all Ordinary Portland even more depending on the jobsite conditions. cements and supplementary cementitious materials.
SP FLOW ® 380 extends the transport/placement period of ▪1000 L IBC/Bulk the concrete and has a valuable plasticizing effect on concrete which makes the placement easier on jobsite. Store at a temperature between 0 and 35°C, out of direct sunlight. If SP FLOW ® 380 freezes, thaw slowly and homogenize. Store Dosage as stated up to 12 months in the original packaging. ▪Recommended range of dosage : 0.6 to 1.2 % by weight of binder, equal to 0.57 up to 1.13 L/100 kg Technical assistance of binder). When assistance is required please contact LCI’s technical service. Trial tests should be carried out with the materials to be used on site to find the dosage necessary to achieve the Legal notes required result. Data and recommendations relative to the final applications provided by means of this document are based on LCI’s current Overdosing effects knowledge and experience of the products. Above the upper limit of dosage, SP FLOW ® 380 may In case of modification of the application parameters or for the cause excessive air entrainment, concrete segregation and purpose of a different end-use, please contact LCI prior to use. set retardation. Users must refer to the most recent version of the technical and ▪Therefore LCI advises to avoid working at a dosage higher safety datasheet, both available upon request. than 1.2% by weight of binder without prior testing.
SP FLOW ® 380
LUXOR CHEMISTRY & INDUSTRY | Lot 27 Zone Industrielle Bouficha 4010 Sousse | T/F : 73252122 | lci@luxor.com.tn